Synopsis A24-007 Water Colled Xray System.pdf
PDF 42 KB Posted
- Attached to
- A24-007 Water Cooled Xray System
- Solicitation number
- FA812525Q0027
About this file
This is a technical specification document for a Pre-Solicitation (FA812525Q0027) issued by the Department of the Air Force Materiel Command Air Force Sustainment Center for four Water Cooled X-ray Systems.
The required system must automatically adapt to input line voltage of 100-130Vac or 200-250Vac at 50/60Hz, with operating capability of 10-160kV and 0.5-5.0mA. Key specifications include a Beryllium 0.8mm window with 40° directional radiation output of 14R/min at 50cm, radiation leakage less than 2.0 Roentgens per hour at 1 meter, and 100% duty cycle at 120°F. The system includes a liquid cooling unit (54 lbs), tube head (7.25" diameter, 30" length, 29 lbs), and control unit (26 lbs). Safety features include pressure relief valve, thermal cut-out, pressure gauge, low pressure cut-out, coolant flow sensor, and keyswitch. Standard accessories include operation manual, carrying case, 100' tubehead cable, 25' power cable, 50' coolant hose, and GUI control software for system operation and diagnostics.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A24-007 Water Cooled Xray System 76 AMXG Request for the purchase of 4 ea.
Water Cooled Xray System to include the following:
Input Line Requirements:
Automatically adapts to input line voltage100-130Vac, 50/60Hz, 20 Amperes maximum.
200-250Vac, 50/60Hz, 10 Amperes maximum.
10 to 160kV, 0.5mA to 5.0mA (800 watts max.)
Constant potential, end-grounded anode, liquid cooled version.
X-Ray Tube Window: Beryllium 0.8mm (directional) 40° directional.
Radiation Output: 14R/min at 50cm filtered with 0.5 inches (12.7mm).
aluminum at 160kV, 5mA.
Radiation Leakage: Less than 2.0 Roentgens per hour at 1 meter from the X-Ray tube target.
Effective Focal Spot: Standard: 0.7mm x 1.0mm (0.03in x 0.04in) EN125430.5mm x 0.5mm (0.02in x 0.02in) nominal IEC60336.
Ambient Temp: 100% duty cycle @ 120°F (49°C).
Duty Cycle: 100%.
Storage Temp: -30°F to 160°F (-35°C to 71°C).
Anode Cooling: Liquid coolant solution closed loop between X-Ray tube anode and cooling unit.
Liquid Cooling Unit Weight: 54lbs. (15.4kg) approx.
Tube Head Dimensions: No greater than 7.25" Diameter, 30" Length.
Liquid Cooled: 29lbs. (13.15kg) X-Ray Control Unit: X-Ray Control Unit Weight: 26lbs. (11.8kg) approx.
Safety Devices:
Tubehead Pressure Relief Valve
Tubehead Thermal Cut-Out
Tubehead Pressure Gauge
Tubehead Low Pressure Cut-Out @ 25psi (1.72 Bar)
Coolant Flow Sensor (liquid cooled only)
Control Unit Safety Keyswitch
Microcomputer-based Self Diagnostics
Continuous Exposure Parameter Display
Standard Accessories:
Operation manual
Tubehead carrying case
Tubehead Cable- 100’ with strain relief
Extra key (1) for Control Unit Safety Lock
Power cable - 25’ with strain relief
Coolant hose - twin, 50’ with self-sealing terminations
(liquid cooled only)
Cooler power cable
GUI Control Software for the GUI is specifically designed for controlling series systems. As an alternative to the front panel control, the GUI will allow the user to control all necessary functions of the system from a user-friendly windows-based menu. Additionally, the GUI can be used as a diagnostic tool when the system is controlled via the front panel.
File details come from the government source that posted it. Updated .