SWVCC 260-B4260-046 M23SW168 Project Drawings 2026-04-15.pdf
PDF 955 KB Posted
- Solicitation number
- DBB-122479
- Issued by
- Brunswick County, Chatham Town, Virginia
About this file
Project Drawings for Roof Access and Fall Protection Improvements
This document is a set of project drawings prepared by HDH Associates for the Virginia Community College System for roof access and fall protection improvements at Southwest Virginia Community College in Cedar Bluff, Virginia. The project, identified as Project Code #260-B4260-046 (M23SW168), encompasses improvements to two buildings: Davis Hall and King Community Center. The scope of work includes installation of two fixed roof access ladders, two roof guardrail systems, one fall anchor compatible with an existing horizontal lifeline system, and associated roof repairs. Davis Hall requires installation of one roof guardrail system, while King Community Center requires installation of two fixed roof access ladders, one roof guardrail system, one new fall anchor with lifeline connection, and roof repairs. The project is designed in accordance with the 2021 Virginia Existing Building Code, Virginia Uniform Statewide Building Code, and 2021 Virginia Construction Code. Sealed bids are due electronically or by hand delivery on Wednesday, July 15, 2026, at 2:00 P.M., with public bid opening on Thursday, July 16, 2026. A pre-bid conference is scheduled for Thursday at 10:00 A.M. at the Virginia Community College System offices in Richmond, Virginia.
The project involves both Davis Hall, a three-story Type II-B non-combustible building (45 feet in height) with Use Group Business B classification, and King Community Center, a two-story Type II-B non-combustible building (30 feet in height) with the same use classification. Design criteria include basic wind speed of 115 miles per hour (Risk Category II, Exposure Category B) and ground snow load of 30 pounds per square feet. The drawings specify that no asbestos inspections were conducted since both buildings were constructed after January 1, 1985, though contractors must comply with all Virginia Occupational Safety and Health regulations regarding lead exposure. All ladder installations must comply with OSHA Standard 1926.1053, maintaining seven-inch toe clearance. A Standard Commonwealth Bid Bond (form CO-10.2) is required regardless of bid amount, and selected contractors must process all pay applications and invoices through e-Builder, the owner's web-based project management software.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text Christiansburg, Virginia 24068
AutoCAD SHX Text
P.O. BOX 6158
AutoCAD SHX Text www.hdhassociates.com
AutoCAD SHX Text
(540) 381-7999
AutoCAD SHX Text
ARCHITECTURE
AutoCAD SHX Text
ENVIRONMENTAL
AutoCAD SHX Text
ENGINEERING
AutoCAD SHX Text
ARCHITECTURE
AutoCAD SHX Text
ENGINEERING
AutoCAD SHX Text
ENVIRONMENTAL
AutoCAD SHX Text
P.O. BOX 6158
AutoCAD SHX Text www.hdhassociates.com
AutoCAD SHX Text Christiansburg, Virginia 24068
AutoCAD SHX Text
(540) 381-7999
AutoCAD SHX Text
DAVID
AutoCAD SHX Text C.
AutoCAD SHX Text
LIEBAL
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text W
AutoCAD SHX Text N
AutoCAD SHX Text V
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text Lic. No.
AutoCAD SHX Text 37780
AutoCAD SHX Text 4/15/26
AutoCAD SHX Text
SOUTHWEST VIRGINIA COMMUNITY COLLEGE
AutoCAD SHX Text
DATE: APRIL 15, 2026APRIL 15, 2026
AutoCAD SHX Text
ROOF ACCESS AND FALL PROTECTION IMPROVEMENTS
AutoCAD SHX Text
PROJECT CODE: 260-B4260-046
AutoCAD SHX Text
PERMIT COPY
AutoCAD SHX Text T-1 TITLE SHEET TITLE SHEET A-1 DAVIS HALL ROOF PLAN & DAVIS HALL ROOF PLAN & DETAILS A-2 KING COMMUNITY CENTER ROOF KING COMMUNITY CENTER ROOF PLAN A-3 DETAILSDETAILS
AutoCAD SHX Text
DRAWING INDEX
AutoCAD SHX Text T-1
AutoCAD SHX Text
PROJECT LOCATION CEDAR BLUFF, VIRGINIA
AutoCAD SHX Text BUILDING INFORMATION DAVIS HALL POINT OF CONTACT INFORMATION - MIKE WAGNER VCCS PROJECT MANAGER MWAGNER@VCCS.EDU USE GROUP: BUSINESS B CONSTRUCTION TYPE (TABLE 601) TYPE II-B NON-COMBUSTIBLE UNPROTECTED BUILDING HEIGHT - THREE STORIES (45 FT) DESIGN CRITERIA 2021 VIRGINIA EXISTING BUILDING CODE (2021 VEBC) VIRGINIA UNIFORM STATEWIDE BUILDING CODE (VUSBC) 2021 VIRGINIA CONSTRUCTION CODE (VCC) 2021 CONSTRUCTION AND PROFESSIONAL SERVICES MANUAL, 2025 EDITION, REV 0 - 03/17/25 2021 VIRGINIA EXISTING BUILDING CODE CHAPTER 6 IN ACCORDANCE WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATIONS DOES NOT EXCEED 50% OF THE VALUE OF THE BUILDING. PER VUSBC 705.11 EXCEPTION 1 A PARAPET IS NOT REQUIRED ON EXTERIOR WALLS WHICH ARE NOT REQUIRED TO BE FIRE RATED BECAUSE OF FIRE SEPARATION DISTANCE. WIND SPEED (2021 VCC SECTION 1609) BASIC WIND SPEED 115 MPH WIND LOAD IMPORTANCE FACTOR RISK CATEGORY II EXPOSURE CATEGORY B SNOW LOAD GROUND SNOW LOAD: 30 PSF SNOW LOAD IMPORTANCE FACTOR 1.0
AutoCAD SHX Text
COMMONWEALTH OF VIRGINIA VIRGINIA COMMUNITY COLLEGE SYSTEM
AutoCAD SHX Text AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS HAS NOT BEEN CONDUCTED BECAUSE THE BUILDING WAS CONSTRUCTED AFTER JANUARY 1, 1985 AND THE OWNER HAS NO KNOWLEDGE OF LEAD CONTAINING OR COATED BUILDING COMPONENTS IN THE BUILDING. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE RECYCLED TO THE EXTENT POSSIBLE.
AutoCAD SHX Text AN ASBESTOS INSPECTION WAS NOT PERFORMED BECAUSE ALL PORTIONS OF THE EXISTING BUILDING THAT MAY BE AFFECTED BY THE WORK WERE ORIGINALLY CONSTRUCTED AFTER JANUARY 1, 1985.
AutoCAD SHX Text
SOUTHWEST VIRGINIA COMMUNITY COLLEGE CAMPUS
AutoCAD SHX Text SOUTHWEST VIRGINIA COMMUNITY COLLEGE 635 COMMUNITY COLLEGE RD, CEDAR BLUFF, VA 24609
AutoCAD SHX Text BUILDING INFORMATION KING COMMUNITY CENTER POINT OF CONTACT INFORMATION - MIKE WAGNER VCCS PROJECT MANAGER MWAGNER@VCCS.EDU USE GROUP: BUSINESS B CONSTRUCTION TYPE (TABLE 601) TYPE II-B NON-COMBUSTIBLE UNPROTECTED BUILDING HEIGHT - TWO STORIES (30 FT) DESIGN CRITERIA 2021 VIRGINIA EXISTING BUILDING CODE (2021 VEBC) VIRGINIA UNIFORM STATEWIDE BUILDING CODE (VUSBC) 2021 VIRGINIA CONSTRUCTION CODE (VCC) 2021 CONSTRUCTION AND PROFESSIONAL SERVICES MANUAL, 2025 EDITION, REV 0 - 03/17/25 2021 VIRGINIA EXISTING BUILDING CODE CHAPTER 6 601.2.1 LEVEL 1 ALTERATION (ROOF SPOT REPAIR - INSTALLING FALL ANCHOR TO EXISTING METAL DECK) MINIMUM ROOF COVERING CLASSIFICATION (VBC TABLE 1505.1) CLASS A PROVIDED 2021 VIRGINIA ENERGY CONSERVATION CODE CLIMATE ZONE 4 (TABLE C402.1.3) EXISTING INSULATION R= 25.65 NEW INSULATION R=25.65 IN ACCORDANCE WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATIONS DOES NOT EXCEED 50% OF THE VALUE OF THE BUILDING. PER VUSBC 705.11 EXCEPTION 1 A PARAPET IS NOT REQUIRED ON EXTERIOR WALLS WHICH ARE NOT REQUIRED TO BE FIRE RATED BECAUSE OF FIRE SEPARATION DISTANCE. WIND SPEED (2021 VCC SECTION 1609) BASIC WIND SPEED 115 MPH WIND LOAD IMPORTANCE FACTOR RISK CATEGORY II EXPOSURE CATEGORY B SNOW LOAD GROUND SNOW LOAD: 30 PSF SNOW LOAD IMPORTANCE FACTOR 1.0
AutoCAD SHX Text
DAVIS HALL & KING COMMUNITY CENTER ASBESTOS INSPECTION NOTE:
AutoCAD SHX Text
DAVIS HALL & KING COMMUNITY CENTER LEAD INSPECTION NOTE:
NO ASBESTOS CONTAINING MATERIALS SHALL BE USED ON THIS PROJECT.
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
RD
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
DAVIS HALL ROOF PLAN
AutoCAD SHX Text
SCALE: 3/32" = 1'-0"
AutoCAD SHX Text V
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
FALL PROTECTION RAILING DETAIL
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A1
AutoCAD SHX Text A1
AutoCAD SHX Text
SCOPE OF WORK: : INSTALLATION OF 1 ROOF GUARDRAIL SYSTEM
AutoCAD SHX Text
GENERAL NOTE: : CONTRACTOR SHALL PROTECT EXISTING ROOFING MATERIALS FROM DAMAGE
AutoCAD SHX Text
ROOF LEGEND
AutoCAD SHX Text
EXISTING CURB MOUNTED VENT
AutoCAD SHX Text
EXISTING ROOF DRAIN 4'-0" X 4'-0" SUMP
AutoCAD SHX Text
EXISTING VENT PIPE
AutoCAD SHX Text
EXISTING CHIMNEY
AutoCAD SHX Text
RD
AutoCAD SHX Text V
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
EXISTING HVAC UNIT
AutoCAD SHX Text
EXISTING ROOF HATCH
AutoCAD SHX Text
EXISTING ROOF PERIMETER WARNING TAPE
AutoCAD SHX Text
EXISTING WALK PADS
AutoCAD SHX Text
NON-PENETRATING GUARD RAIL DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text A1
AutoCAD SHX Text A1
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
COMMISSION NUMBER:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Christiansburg, Virginia 24068
AutoCAD SHX Text
P.O. BOX 6158
AutoCAD SHX Text www.hdhassociates.com
AutoCAD SHX Text
(540) 381-7999
AutoCAD SHX Text
ARCHITECTURE
AutoCAD SHX Text
ENVIRONMENTAL
AutoCAD SHX Text
ENGINEERING
AutoCAD SHX Text
ARCHITECTURE
AutoCAD SHX Text
ENGINEERING
AutoCAD SHX Text
ENVIRONMENTAL
AutoCAD SHX Text
P.O. BOX 6158
AutoCAD SHX Text www.hdhassociates.com
AutoCAD SHX Text Christiansburg, Virginia 24068
AutoCAD SHX Text
(540) 381-7999
AutoCAD SHX Text
DAVID
AutoCAD SHX Text C.
AutoCAD SHX Text
LIEBAL
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text W
AutoCAD SHX Text N
AutoCAD SHX Text V
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text Lic. No.
AutoCAD SHX Text 37780
AutoCAD SHX Text A-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DAVIS HALL ROOF PLAN & DETAILS
AutoCAD SHX Text
VIRGINIA COMMUNITY COLLEGE SYSTEM
AutoCAD SHX Text
SOUTHWEST VIRGINIA COMMUNITY COLLEGE
AutoCAD SHX Text
ROOF ACCESS AND FALL PROTECTION IMPROVEMENTS
AutoCAD SHX Text
CEDAR BLUFF
AutoCAD SHX Text
VIRGINIA
AutoCAD SHX Text
DCL
AutoCAD SHX Text
NRL
AutoCAD SHX Text
DCL
AutoCAD SHX Text
APRIL 15, 2026
AutoCAD SHX Text
AutoCAD SHX Text
PROJECT CODE #:
AutoCAD SHX Text 260-B4260-046
AutoCAD SHX Text
DEB PROJECT CODE #:
AutoCAD SHX Text
AutoCAD SHX Text
PERMIT COPY
AutoCAD SHX Text 8'
AutoCAD SHX Text 4'
AutoCAD SHX Text
AutoCAD SHX Text 12'
AutoCAD SHX Text 24'
AutoCAD SHX Text 3/32"=1'-0"
AutoCAD SHX Text
GRAPHIC SCALES
AutoCAD SHX Text 12'
4/15/26
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
KING COMMUNITY CENTER
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text
SCALE: 3/32" = 1'-0"
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text
ROOF I
AutoCAD SHX Text
ROOF H
AutoCAD SHX Text
ROOF C
AutoCAD SHX Text
ROOF D
AutoCAD SHX Text
AutoCAD SHX Text A2
AutoCAD SHX Text A3
AutoCAD SHX Text
AutoCAD SHX Text A2
AutoCAD SHX Text A3
AutoCAD SHX Text SCOPE OF WORK: : INSTALLATION OF 2 FIXED ROOF ACCESS LADDERS INSTALLATION OF 1 ROOF GUARDRAIL SYSTEM INSTALLATION OF ONE NEW FALL ANCHOR AND NEW LIFELINE CONNECTED TO EXISTING HORIZONTAL LIFELINE SYSTEM REPAIR ROOF AFTER INSTALLING ANCHOR & GUARDRAIL
AutoCAD SHX Text
DEMO NOTE: : REMOVE EXISTING LADDER (ROOF C TO D)
AutoCAD SHX Text
GENERAL NOTE: : CONTRACTOR SHALL PROTECT EXISTING ROOFING MATERIALS FROM DAMAGE
AutoCAD SHX Text
ROOF LEGEND
AutoCAD SHX Text
EXISTING CURB MOUNTED VENT
AutoCAD SHX Text
EXISTING ROOF DRAIN 4'-0" X 4'-0" SUMP
AutoCAD SHX Text
EXISTING VENT PIPE
AutoCAD SHX Text
RD
AutoCAD SHX Text V
AutoCAD SHX Text
EXISTING HVAC UNIT
AutoCAD SHX Text
EXISTING ROOF HATCH
AutoCAD SHX Text
EXISTING WALK PADS
AutoCAD SHX Text
EXISTING FALL PROTECTION SYSTEM
AutoCAD SHX Text
NEW FALL PROTECTION SYSTEM
AutoCAD SHX Text
EXISTING ROOF PENETRATION
AutoCAD SHX Text
FALL PROTECTION ANCHOR SECTION
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text A2
AutoCAD SHX Text A2
AutoCAD SHX Text
FALL PROTECTION ANCHOR PLATE
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text A2
AutoCAD SHX Text A2
AutoCAD SHX Text
AutoCAD SHX Text A2
AutoCAD SHX Text A2
AutoCAD SHX Text
FALL PROTECTION LIFELINE DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
COMMISSION NUMBER:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Christiansburg, Virginia 24068
AutoCAD SHX Text
P.O. BOX 6158
AutoCAD SHX Text www.hdhassociates.com
AutoCAD SHX Text
(540) 381-7999
AutoCAD SHX Text
ARCHITECTURE
AutoCAD SHX Text
ENVIRONMENTAL
AutoCAD SHX Text
ENGINEERING
AutoCAD SHX Text
ARCHITECTURE
AutoCAD SHX Text
ENGINEERING
AutoCAD SHX Text
ENVIRONMENTAL
AutoCAD SHX Text
P.O. BOX 6158
AutoCAD SHX Text www.hdhassociates.com
AutoCAD SHX Text Christiansburg, Virginia 24068
AutoCAD SHX Text
(540) 381-7999
AutoCAD SHX Text
DAVID
AutoCAD SHX Text C.
AutoCAD SHX Text
LIEBAL
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text W
AutoCAD SHX Text N
AutoCAD SHX Text V
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text Lic. No.
AutoCAD SHX Text 37780
AutoCAD SHX Text A-2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
KING COMMUNITY CENTER ROOF PLAN
AutoCAD SHX Text
VIRGINIA COMMUNITY COLLEGE SYSTEM
AutoCAD SHX Text
SOUTHWEST VIRGINIA COMMUNITY COLLEGE
AutoCAD SHX Text
ROOF ACCESS AND FALL PROTECTION IMPROVEMENTS
AutoCAD SHX Text
CEDAR BLUFF
AutoCAD SHX Text
VIRGINIA
AutoCAD SHX Text
DCL
AutoCAD SHX Text
NRL
AutoCAD SHX Text
DCL
AutoCAD SHX Text
APRIL 15, 2026
AutoCAD SHX Text
AutoCAD SHX Text
PROJECT CODE #:
AutoCAD SHX Text 260-B4260-046
AutoCAD SHX Text
DEB PROJECT CODE #:
AutoCAD SHX Text
AutoCAD SHX Text
PERMIT COPY
AutoCAD SHX Text 8'
AutoCAD SHX Text 4'
AutoCAD SHX Text
AutoCAD SHX Text 12'
AutoCAD SHX Text 24'
AutoCAD SHX Text 3/32"=1'-0"
AutoCAD SHX Text
GRAPHIC SCALES
AutoCAD SHX Text 12'
NOTE: ATTACH LADDER TO EXISTING STRUCTURE TO MEET THE REQUIREMENTS OF OSHA STANDARD 1926.1053
AutoCAD SHX Text NOTES: 1. LADDER SHALL CONFORM TO LADDER SHALL CONFORM TO OSHA STANDARD 1926.1053. 2. MAINTAIN 7" TOE CLEARANCE MAINTAIN 7" TOE CLEARANCE 3. ATTACHMENTS IN SAME ATTACHMENTS IN SAME LOCATIONS
AutoCAD SHX Text
NEW REPLACEMENT LADDER DETAIL
AutoCAD SHX Text
ROOF C TO D
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text A3
AutoCAD SHX Text
NEW LADDER DETAIL
AutoCAD SHX Text
ROOF H TO I
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text A2
AutoCAD SHX Text A3
AutoCAD SHX Text NOTES: 1. LADDER SHALL CONFORM TO LADDER SHALL CONFORM TO OSHA STANDARD 1926.1053. 2. MAINTAIN 7" TOE CLEARANCEMAINTAIN 7" TOE CLEARANCE
AutoCAD SHX Text NOTE: ATTACH LADDER TO EXISTING STRUCTURE TO MEET THE REQUIREMENTS OF OSHA STANDARD 1926.1053
AutoCAD SHX Text NOTE: : REMOVE EIFS ONLY AT LOCATIONS OF LADDER MOUNTING BRACKETS. ANY DAMAGE TO EIFS SHALL BE REPAIRED BY CONTRACTOR.
AutoCAD SHX Text
GUARD RAIL DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text A3
AutoCAD SHX Text V
AutoCAD SHX Text V
AutoCAD SHX Text
ROOF H
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text A3
AutoCAD SHX Text
KING COMMUNITY CENTER
AutoCAD SHX Text
ROOF H
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A2
AutoCAD SHX Text A3
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text A3
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text A3
AutoCAD SHX Text
GUARD RAIL ANCHOR PLATE
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text A3
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
COMMISSION NUMBER:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Christiansburg, Virginia 24068
AutoCAD SHX Text
P.O. BOX 6158
AutoCAD SHX Text www.hdhassociates.com
AutoCAD SHX Text
(540) 381-7999
AutoCAD SHX Text
ARCHITECTURE
AutoCAD SHX Text
ENVIRONMENTAL
AutoCAD SHX Text
ENGINEERING
AutoCAD SHX Text
ARCHITECTURE
AutoCAD SHX Text
ENGINEERING
AutoCAD SHX Text
ENVIRONMENTAL
AutoCAD SHX Text
P.O. BOX 6158
AutoCAD SHX Text www.hdhassociates.com
AutoCAD SHX Text Christiansburg, Virginia 24068
AutoCAD SHX Text
(540) 381-7999
AutoCAD SHX Text
DAVID
AutoCAD SHX Text C.
AutoCAD SHX Text
LIEBAL
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text W
AutoCAD SHX Text N
AutoCAD SHX Text V
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text Lic. No.
AutoCAD SHX Text 37780
AutoCAD SHX Text A-3
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
VIRGINIA COMMUNITY COLLEGE SYSTEM
AutoCAD SHX Text
SOUTHWEST VIRGINIA COMMUNITY COLLEGE
AutoCAD SHX Text
ROOF ACCESS AND FALL PROTECTION IMPROVEMENTS
AutoCAD SHX Text
CEDAR BLUFF
AutoCAD SHX Text
VIRGINIA
AutoCAD SHX Text
DCL
AutoCAD SHX Text
NRL
AutoCAD SHX Text
DCL
AutoCAD SHX Text
APRIL 15, 2026
AutoCAD SHX Text
AutoCAD SHX Text
PROJECT CODE #:
AutoCAD SHX Text 260-B4260-046
AutoCAD SHX Text
DEB PROJECT CODE #:
AutoCAD SHX Text
AutoCAD SHX Text
PERMIT COPY
AutoCAD SHX Text 4'
AutoCAD SHX Text 2'
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 1/4"=1'-0"
File details come from the government source that posted it. Updated .