STRUCTURAL_DRAWING.pdf
PDF 3 MB Posted
- Attached to
- Club 19 - Awning: 4-Inch Insulated Roof System
- Solicitation number
- PSPW-26-QQ-09
- Issued by
- Broward County, Florida
About this file
This is a structural drawing document prepared for the City of Pembroke Pines, Florida, related to the Club 19 awning project involving a 4-inch insulated roof system installation. The drawing provides detailed architectural and structural specifications for the new covered awning construction, including demolition requirements, material specifications, and structural component designs necessary for the project execution. The document serves as the technical blueprint for qualified contractors bidding on the furnish and install contract, establishing the precise dimensions, construction details, and engineering requirements that bidders must follow in their proposals and project execution. The structural drawing establishes the baseline technical requirements that all contractors must meet to ensure compliance with the project specifications outlined in the formal solicitation.
The structural drawing contains the engineering and architectural details required for contractors to accurately estimate costs, materials, and labor for the awning installation project. This document is essential for pricing the bid, as it specifies the exact construction methodology, structural components, roofing system specifications, and finishing requirements. Contractors must reference this drawing in conjunction with the project specifications to provide comprehensive bids that address all demolition work, material procurement, structural installation, roofing application, and related labor costs associated with the 4-inch insulated roof system awning project for Club 19.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8/27/2026 6:47 PMArpit PanchalPrint by:
CALC ENGINEERING
www.calceng.com 2000 NW 89th PL. Unit 102
DORAL, FL 33172
Phone: (305) 898-9995
ENGINEERING BUSINESS
CA CERTIFICATION: 32566
MASOOD HAJALI P.E
LIC #82038
Calc Engineering
C
LU
B
O
U
TD
O O
R B
A R
T
A
FT
S T, P
EM
B R O
KE
PI
N
ES
FL
U N
IT
ED
S
TA
TE
S
Date
Scale
Sheet
Project Number
Drawn By
DE
SI
GN
IS
B
AS
ED
O
N
FB
C
, 8
TH
E
DI
TI
O N
DESIGN CRITERIA & GENERAL NOTES
S1.0 DESIGN CRITERIA & GENERAL NOTES
SHEET INDEX
S1.1 S1.2
FLOOR PLAN
FOUNDATION PLAN
1. WIND:
MEAN ROOF HEIGHT 8'-0"
BASIC WIND VELOCITY: 170 MPH (ULT)
RISK CATEGORY: II
EXPOSURE C
2. ROOF DESIGN LOADS:
DEAD LOAD: 07 PSF
LIVE LOADS: 30 PSF
1. FLORIDA BUILDING CODE 2023, 8TH EDITION, HVHZ
2. ASCE 7-22 FOR WIND ANALYSIS AND DESIGN
3. ACI 318-19
4. ADM 2020
APPLICABLE CODES
GENERAL NOTES
DESIGN CRITERIA AND LOADS
1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF EXISTING AND/OR ADJACENT STRUCTURES, STREETS, AND SIDEWALKS DURING
CONSTRUCTION.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. SHOULD A DISCREPANCY BE FOUND STOP WORK IMMEDIATELY AND NOTIFY
OUR OFFICE.
3. CONTRACTOR SHALL WORK THE STRUCTURAL PLANS IN CONJUNCTION WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND
PLUMBING DRAWINGS IF APPLICABLE.
4. EXISTING STRUCTURE: CONTRACTOR SHALL REVIEW THE ORIGINAL CONSTRUCTION DRAWINGS OF THE EXISTING BUILDING PRIOR TO BIDDING
AND DURING CONSTRUCTION TO VERIFY THE EXISTING MEMBERS AFFECTED BY THE NEW CONSTRUCTION.
5. THE USE OF SCALE TO OBTAIN DIMENSIONS NOT SHOWN ON THESE PLANS IS STRICTLY FORBIDDEN. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR ERRORS RESULTING FROM SUCH ACTION.
6. ALL SPECIFIED MATERIALS AND CONNECTORS CAN BE SUBSTITUTED WITH EQUAL OR BETTER, WITH THE APPROVAL OF ENGINEER OF
RECORD.
7. CONTRACTOR SHALL BE THE ONLY PARTY RESPONSIBLE FOR THE DESIGN, INSTALLATION AND DISMANTLING OF FORMING, TEMPORARY
SHORING AND/OR BRACING. PROVIDE SHOP DRAWINGS FOR REVIEW SIGNED AND SEALED BY A FLORIDA LICENSED ENGINEER.
CONTRACTORS
- O/C: ON CENETRS(S)
- W/: WITH
- SS: STAINLESS STEEL
- TYP. TYPICAL
- EA: EACH
- T.E: THICKENED EDGE
- U.T.R: UNPERMITTED TO REMAIN
- N.T.B.A. NEW TO BE ADDED
- PEN: PENETRATION
ABBREVIATIONS
1. EXISTING WINDOW/DOOR DEMOLITION AND NEW WINDOW/DOOR INSTALLATION SHALL BE DONE IN A SINGLE DAY FOR EACH UNIT.
2. WORK AREAS SHALL BE SEPARATED FROM OCCUPANTS NOT INVOLVED WITH THE CONSTRUCTION. CONTRACTOR TO PROVIDE MEANS OF
SEPARATING THESE AREAS - DO NOT ALLOW ANY ACCESS FROM OCCUPANTS UNTIL NEW WINDOWS/DOORS ARE FULLY INSTALLED AND INSPECTED.
3. ALL LIFE SAFETY SYSTEMS SHALL REMAIN ACTIVE AND FULLY OPERATIONAL DURING RAILING CONSTRUCTION AS PER NFPA 1 (2018) CHAPTER 16.
4. WHERE THE BUILDING IS PROTECTED BY FIRE PROTECTION SYSTEMS, SUCH SYSTEMS SHALL BE MAINTAINED OPERATIONAL AT ALL TIMES
DURING ALTERATION AS PER NFPA 1 (2018) CHAPTER 16.4.4-16.4.4.6.
5. ALL DESIGNATED EGRESS SHALL REMAIN UNOBSTRUCTED THROUGHOUT THE DURATION OF THE PROJECT AS PER NFPA 101 (2018) CHAPTER
7 AND 4.6.10.
6. CONTRACTOR SHALL REMOVE ANY MATERIALS AND DEBRIS PRODUCT OF DEMOLITION FROM JOB SITE. PROVIDE APPROVED DUMPSTER OR
COMPLETELY REMOVE FROM PROPERTY.
7. ESTIMATED JOB COMPLETION TIME: (1) DAY PER UNIT INCLUDING DEMOLITION AND NEW WINDOW/DOOR INSTALLATION. COORDINATE SAME
DAY INSPECTION WITH THE BUILDING DEPARTMENT AND/OR THE SPECIAL INSPECTOR.
LIFE SAFETY AND FIRE PROTECTION NOTES
SCALE: NTS
AERIAL VIEW - SCOPE OF WORKN
1. STRUCTURALTUBES, ANGLES, CHANNELS AND PLATES 6061 - T6.
2. ALL WELDS TO USE 5356 FILLER AND SHALL COMPLY WITH AWS STANDARDS.
3. ALL FASTENER SHALL BE SELF DRILLING FASTENERS BY TEK.
STRUCTURAL ALUMINUM
S2.0 STANDARD DETAILS
S1.3 ROOF FRAMING PLAN
1. SUBMIT CONCRETE MIX DESIGN TO ENGINEER FOR REVIEW PRIOR TO POURING.
2. ALL NORMAL-WEIGHT CONCRETE MUST BE MIXED IN ACCORDANCE WITH ACI 301 TO ACHIEVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF
3.000PSI. WATER/CEMENT RATIO MUST BE 0.40 MAX. BY WEIGHT UNO ON PLANS AND 0.15 MAX. WATER-SOLUBLE CHLORIDE ION CONTENT IN
CONCRETE (PERCENT BY WEIGHT OF CEMENT) IN ACCORDANCE TO TABLE 19.3.2.1 OF ACI 318-19.
3. SLUMP SHALL BE 4” (±1).
4. CONTRACT AN INDEPENDENT TESTING LABORATORY TO PERFORM THE CONCRETE CYLINDER SAMPLING AND TESTING AS REQUIRED FLORIDA
BUILDING CODE, 2023. SUBMIT TEST REPORTS TO ENGINEER.
5. AGGREGATES TO BE CLEAN AND WELL GRADED, MAX. SIZE 1”. VERTICAL DROP NOT TO EXCEED 8’-0”.
6. NO ADDITIONAL WATER SHALL BE ADDED TO THE CONCRETE MIX AT THE JOBSITE UNLESS PREVIOUSLY APPROVED.
7. CONCRETE SHALL BE COMPACTED USING MECHANICAL VIBRATION.
8. PROVIDE ALL FORMING AND TEMPORARY SHORING.
9. REMOVE ALL DEBRIS FROM FORMS BEFORE POURING.
10. NO PIPES OR CONDUITS EXCEEDING 1/3 THE SLAB THICKNESS IN OUTSIDE DIAMETER SHALL BE EMBEDDED IN THE STRUCTURAL CONCRETE FLOOR
OR ROOF WITHOUT WRITTEN APPROVAL FROM THE ENGINEER. WHERE PIPES OR CONDUITS ARE PERMITTED, THEY SHALL BE PLACED NO
CLOSER THAN THREE DIAMETER O/C AND SHALL BE LOCATED SO AS NOT TO IMPAIR THE STRENGTH OF THE STRUCTURE. JUNCTION BOXES
MAY BE PLACED IN STRUCTURAL CONCRETE SLABS BUT SHALL NOT EXCEED 4 1/2” X 4 1/2” X 3 1/2” IN DEPTH, AND SHALL BE SEPARATED FROM OTHER
JUNCTION BOXES BY NOT LESS THAN 8”.
REINFORCING STEEL:
1. STANDARD: ASTM A-615, GRADE 60, ASTM A185 FOR WELDED WIRE FABRIC.
2. REINFORCEMENT PLACEMENT TOLERANCES MUST COMPLY WITH SECTION 2.2 OF ACI 117.
3. SHALL BE DEFORMED BARS, FREE FROM LOOSE RUST AND SCALE.
4. CONTRACTOR TO PROVIDE CHAIRS BOLSTERS, SPACERS ETC. IN ORDER TO CORRECTLY ASSEMBLE, PLACE AND SUPPORT ALL REINFORCING IN
PLACE.
5. ALL REINFORCING SHALL CONFORM TO THE ’’MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES” (ACI-315)
6. CONCRETE COVER FOR REINFORCEMENT:
FOOTINGS, PILE CAPS, GRADE BEAMS 3” CLEAR ALL AROUND
SLAB ON GRADE: BOTTOM=2” WHEN POURED OVER VAPOR BARRIER
EXTERIOR SLABS (EXPOSED TO WEATHER): BOTTOMS=1” - TOP=1.5”
INTERIOR SLABS: 1"
COLUMNS AND BEAMS NOT EXPOSED TO WEATHER: BOTTOM=2” - TOP=2” CLEAR TO TIES - SIDE=1.5” CLEAR TO TIES
COLUMNS AND BEAMS EXPOSED TO WEATHER: BOTTOM=2” - TOP=2” CLEAR TO TIES - SIDE=1.5” CLEAR TO TIES
RETAINING WALLS : 2"
7. MIN. BAR LAP TO BE 48 BAR DIAMETERS U.O.N.
CONCRETE AND REINFORCING
SCOPE OF WORK:
ALUM ROOF
(1318 SQFT)
SHALLOW FOUNDATIONS
1. SOIL STATEMENT: VISUAL INSPECTION OF THE SITE SHOWS A SOIL OF LIMESTONE WITH SANDY POCKETS AND WITH LAYER OF TOPSOIL. THE
LIMESTONE HAS A SAFE BEARING CAPACITY IN EXCESS OF 2000PSF. AT THE TIME OF CONSTRUCTION, A LICENSED ENGINEER SHALL SUBMIT TO THE
BUILDING OFFICIAL A LETTER ATTESTING THAT THE SITE HAS BEEN OBSERVED AND THE FOUNDATION CONDITIONS ARE SIMILAR TO THOSE UPON
WHICH THE DESIGN IS BASED.
2. SHOULD ORGANIC SILT, CLAY POCKETS OR OTHER UNSUITABLE BEARING CONDITIONS BE ENCOUNTERED DURING EXCAVATIONS, NOTIFY THE
ENGINEER BEFORE CONTINUING WITH CONSTRUCTION.
3. TOP OF FOOTINGS SHALL BE AT 2'-0" BELOW GRADE AT ALL POINTS U.N.O.
4. CONTRACTOR SHALL PROVIDE SURFACE DRAINAGE AND PUMPS TO PROTECT EXCAVATIONS FROM FLOODING AFTER APPROVAL.
5. THE GROUND ADJACENT TO THE FOUNDATION SHALL BE SLOPED AWAY FORM THE BUILDING AT A SLOPE NOT LESS THEN 1:20 (5% SLOPE) FOR A MIN.
DISTANCE OF 10' PERPENDICULAR TO THE FACE OF WALL
S1.0
CALC ENGINEERING
www.calceng.com 2000 NW 89th PL. Unit 102
DORAL, FL 33172
Phone: (305) 898-9995
ENGINEERING BUSINESS
CA CERTIFICATION: 32566
MASOOD HAJALI P.E
LIC #82038
Calc Engineering
C
LU
B
O
U
TD
O O
R B
A R
T
A
FT
S T, P
EM
B R
ES
FL
U N
TE
S
Date
Scale
Sheet
Project Number
Drawn By
DE
SI
GN
IS
B
AS
ED
O
N
FB
C
, 8
TH
E
DI
TI
O N
FLOOR PLAN
SCALE: 1/8"=1'-0"
FLOOR PLAN1N
71'-0"
'-9
27'-4"
'-4
41'-3"
'-8
3'- 8"
SCOPE OF WORK:
ALUM ROOF
(1318 SQFT)
2'- 6"
57'-8"
S1.1
(E)BUILDING
CALC ENGINEERING
www.calceng.com 2000 NW 89th PL. Unit 102
DORAL, FL 33172
Phone: (305) 898-9995
ENGINEERING BUSINESS
CA CERTIFICATION: 32566
MASOOD HAJALI P.E
LIC #82038
Calc Engineering
C
LU
B
O
U
TD
O O
R B
A R
T
A
FT
S T, P
EM
B R
ES
FL
U N
TE
S
Date
Scale
Sheet
Project Number
Drawn By
DE
SI
GN
IS
B
AS
ED
O
N
FB
C
, 8
TH
E
DI
TI
O N
FOUNDATION PLAN
SCALE: 1/4"=1'-0"
FOUNDATION PLAN1
11'-5" 15'-7" 17'-11" 1'-4"
'-4
15'-0" 16'-0"
31'-0"
70'-7"
8'-
(E)12"Ø CONC
COL - VIF
(E)12"Ø CONC
COL - VIF
(E)12"Ø CONC
COL - VIF
(E)12"Ø CONC
COL - VIF
(E)12"Ø CONC
COL - VIF
(E)12"Ø CONC
COL - VIF
(E)12"Ø CONC
COL - VIF
(E)12"Ø CONC
COL - VIF
(E)12"Ø CONC
COL - VIF
(E) 6" THK SLAB ON GRADE TO REMAIN
ALL ALUMINUM COLUMN 6X6X1/8 REF 6/S2.0
12'-2" 12'-2"
(E)WALL
LEGEND:
ALUM COLUMN
NOTE:
1. ALL CONNECTIONS & DETAILS REF SHEET S2.0.
(E)CONC COLUMN
S2.0
2'- 6"
-S Q
F-30
6X6X1/8 ALUM COL
REF DETAIL 7A/S2.0
S1.2
(E)BUILDING
CALC ENGINEERING
www.calceng.com 2000 NW 89th PL. Unit 102
DORAL, FL 33172
Phone: (305) 898-9995
ENGINEERING BUSINESS
CA CERTIFICATION: 32566
MASOOD HAJALI P.E
LIC #82038
Calc Engineering
C
LU
B
O
U
TD
O O
R B
A R
T
A
FT
S T, P
EM
B R
ES
FL
U N
TE
S
Date
Scale
Sheet
Project Number
Drawn By
DE
SI
GN
IS
B
AS
ED
O
N
FB
C
, 8
TH
E
DI
TI
O N
SCALE: 1/4"=1'-0"
ROOF FRAMING PLAN1
ROOF FRAMING PLAN
12'-2" 15'-7" 17'-8" 1'-0"
'-8
15'-0" 16'-0"
48'-8"
71'-0"
8'-
4'-
6"
1'-0"
1'- 0"
'-8
1'- 0"
17'-8"
(E)CONC BEAM - VIF(E)CONC BEAM - VIF
(E )C
ON
C
BE
AM
VI
F
(E )C
ON
C
BE
AM
VI
F
(E)CONC BEAM - VIF
(E)CONC BEAM - VIF
(E )C
ON
C
BE
AM
VI
F
(E )C
ON
C
BE
AM
VI
F
(E )C
ON
C
BE
AM
VI
F
(E)CONC BEAM - VIF
4X10X1/8 ALUM BEAM
4X10X1/8 ALUM BEAM
4X10X1/8 ALUM BEAM
4" INSULATED ROOF
(0.024X2LB)
PRODUCT APPROVAL NUMBER
FL-7561
(E)ROOF OVERHANG
(E )R
OO
F
OV
ER
HA
NG
(E )R
OO
F
OV
ER
HA
NG
(E)ROOF OVERHANG
(E)ROOF OVERHANG
(E)WALL
LEGEND:
ALUM COLUMN
ALUM BEAM
NOTE:
1. ALL CONNECTIONS & DETAILS REF SHEET S2.0.
(E)CONC COLUMN
(E)CONC BEAM
4" INSULATED ROOF
(0.024X2LB)
PRODUCT APPROVAL NUMBER
FL-7561
(E)ROOF OVERHANG (TYP)
12'-2"11'-5"
S2.0
TYP
S2.0
S2.0
S2.0
S2.0
TYP
2" :1
2"
SL
OP
E
2" :1
2"
SL
OP
E
2" :1
2"
SL
OP
E
4" :1
2"
SL
OP
E
4" :1
2"
SL
OP
E
98'-11"
2'-6" OH
S2.0
S2.0
S1.3
STANDARD DETAILS
CALC ENGINEERING
www.calceng.com 2000 NW 89th PL. Unit 102
DORAL, FL 33172
Phone: (305) 898-9995
ENGINEERING BUSINESS
CA CERTIFICATION: 32566
MASOOD HAJALI P.E
LIC #82038
Calc Engineering
C
LU
B
O
U
TD
O O
R B
A R
T
A
FT
S T, P
EM
B R
ES
FL
U N
TE
S
Date
Scale
Sheet
Project Number
Drawn By
DE
SI
GN
IS
B
AS
ED
O
N
FB
C
, 8
TH
E
DI
TI
O N
RECEIVING CHANNEL WITH
#12 TEK SCREW @ 8" O.C.
TOP & BOTTOM
INSULATED ROOF
PER PLAN
EXISTING CONC. TIE BEAM
OR CBS FILLED CELL
4"X 3" TAPCONS
@ 12" O.C. (MAX.)
Scale: NTS
INSULATED PANEL TO CBS WALL3 Scale: NTS
BEAM TO CBS WALL5
ALUM BEAM PER PLAN
EXISTING CONC. TIE BEAM
OR CBS FILLED CELL
2X2X1
4 ANGLE W/ (3) 14"X3" TAPCONS
(MIN 2 12" EMBEDMENT TO CONCRETE)
& (3)W/3/8" THROUGH BOLTS AT BEAM
TOP VIEW
SIDE VIEW
EXISTING CONC. TIE BEAM
OR CBS FILLED CELL
2X2X1
4 ANGLE W/ (3) 14"X3" TAPCONS
(MIN 1 12" EMBEDMENT TO CONCRETE)
& (3)W/3/8" THROUGH BOLTS AT BEAM
ALUM BEAM PER PLAN
1/4"X3" LAGS 12" O.C.
ALONG HEADER.
5/16"X4 1/2" LAGS TO EXIST.
TRUSSES (@ 24" O.C. MAX.)
2" FASCIA
SHIM ANGLE
(FOR SLOPED FASCIA)
INSULATED
ALUMINUM PANEL
RECEIVING CHANNEL
WITH #12 TEK SCREWS @
8" O.C. TOP & BOTTOM
SCALE: NTS
INSULATED PANEL TO FASCIA4
BEAM - 4X10X1/8
4"
1/8"
COLUMN - 6X6X1/8GUTTER
Scale: NTS
TYP ALUMINIUM PROFILES1
6"
6"
1/8"
1/2"
1/ 2"
1"
4"
0.055"
1/2"
1"
1/
2"
FASCIA
4" CHANNEL
4"
1" M
IN
ALUM COL PER PLAN
(3)W/3/8" THROUGH
BOLTS AT EACH
COLUMN
#10 SMS 3 PER PANEL
TOP & BOTTOM
GUTTER
ALUM BEAM PER PLAN
Scale: NTS
BEAM TO COLUMN CONNECTION2
INSULATED ALUM. PANEL
ATTACHED TO CARRY BEAM W/
1/4" LAG OR TEK W/1" WASHER
@ 6" O.C.
(2) L3X3X8X3/8" ANGLES(6061-T6)
WITH (2) 3/8" THRUBOLTS.
1/2" HILTI KH- EZ CRC ANCHOR;
2 PER ANGLE@ 6" OC
ALUM COL
PER PLAN
SCALE: NTS
COLUMN TO SOG CONNECTION DETAIL6
1/
2" T
YP
6" O.C.
4" MIN
7" MIN
3" M
IN
E
M
BE
DM
EN
T
3/4" EDGE TYP
6" T
HK
VI
F
(E) 6" THK CONC SLAB - VIF
4" X 0.024 X 2- LB EPS PANELS
(ALLOWABLE CLEAR SPAN CHARTS)
L/80 L/180 L/240L/120
21.97 20.77 19.57 18.36 17.16 15.96 14.75 13.55
21.52 19.86 18.21 16.55 14.89 13.24 11.58
20.97 18.76 16.55 14.34
9.93 5.51 7.72 9.93
12.13
NET ALLOWABLE
LOAD(PSF)1
MAX. ALLOWABLE SPAN (FT)
21.97 20.77 19.57 18.36 17.16 15.96 14.75 13.55
SCALE: NTS
ALUMINUM SPAN CHARTS TABLE7
ASCE 7-22 WIND LOADS: GENERAL REQUIREMENTS
CHAPTER 26, BUILDING OPEN (27.2.0, 27.3.1' 27.4.8)
*DL=7 PSF; LL=20 PSF; DL+LL=27 PSF
(DOWN) USED 30 PSF-L/180=18.21' SPAN MAX.
*WL=53 PSF; DL=7 PSF; 0.6DL+0.6 WL=-27.6 PSF
(UP) USED 30 PSF-L/180=18.21' SPAN MAX.
PRODUCT APPROVAL
NUMBER FL-7561
(E)6" THK SLAB ON
GRADE TO REMAIN
4X10X1/8
ALUM BEAM
4X10X1/8
ALUM BEAM
BEHIND
4" INSULATED ROOF
(0.024X2LB)
PRODUCT APPROVAL NUMBER
FL-7561
6X6X1/8
ALUM COL
6X6X1/8
ALUM COL
6X6X1/8
ALUM COL
6X6X1/8
ALUM COL
6X6X1/8
ALUM COL
6X6X1/8
ALUM COL
6X6X1/8
ALUM COL
(E)CONC COL TO
REMAIN - VIF
(E)CONC BEAM
TO REMAIN - VIF
4" 12"71'-0" 27'-11"
98'-11"
2'-6" OH
OPEN OPEN OPEN OPEN OPEN OPEN OPEN
S2.0
S2.0
4 & 5 S2.0
SCALE: 1/4"=1'-0"
FRONT ELEVATION8
SCALE: NTS
FOUNDATION DETAIL7A
6X6X1/8 COL.
(20" MIN EMBEDMENT)
30" SQ
#5 BAR 12" LONG
THRU COLUMN
WELL
COMPACT FILL
COAT COL. W/
BITUMINOUS PAINT
(4)#5 EACH WAY
TOP & BOTTOM
3" C
LR
S2.0
File details come from the government source that posted it. Updated .