This document is the architectural bid drawings and specifications for the Straits State Park Shower Building Improvements project in St. Ignace, Mackinac County, Michigan. The project involves the construction of a new toilet and shower building, including concrete slabs, exterior walls, roof, windows, doors, plumbing, and electrical work. Key details include:
The project has an estimated occupant load of 18 and will be constructed using Type VB building materials. The building area is approximately 1,101 square feet, with 833 square feet dedicated to the toilet/shower rooms and 268 square feet for utilities and storage. The project must comply with the 2015 Michigan Building, Plumbing, and Mechanical Codes, as well as the 2014 Michigan Electrical Code and the 2010 ICC/ANSI A117.1 Accessibility requirements. Bids are due on May 20, 2022, and the project is scheduled to be awarded in the summer of 2022.
The project is funded by the State of Michigan Department of Technology, Management and Budget. Pricing information, set-asides, and incumbent contractors are not provided in the document. The drawings include detailed specifications for materials, finishes, fixtures, and equipment to be used in the construction.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Straits Plan Updates.pdf | ||
| Civil Plans A.pdf | ||
| Specifications_19156 - Part 2.pdf | ||
| Addendum 2 19156.pdf | ||
| Addendum 1 19156.pdf | ||
| Specifications_19156 - Part 1.pdf | ||
| MEP addenda 1.pdf | ||
| Straits MPE Bids.pdf | ||
| Advertisment 19156.pdf | ||
| Civil Plans B.pdf | ||
| Straits SP Architectural Bids Part 2.pdf | ||
| Straits SP-Electrical Plans.pdf |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ALIGN
DESCRIPTIONSYMBOLS
DESCRIPTION
DESCRIPTION
CONSTRUCTION LEGEND
WALL TYPE
W.P.
EXISTING WALL CONSTRUCTION TO REMAIN.
EXISTING WALL CONSTRUCTION TO BE
REMOVED.
NEW PARTITION
DOORS
EXISTING DOOR TO REMAIN
NEW DOOR & FRAME
DOOR NUMBER, REFER TO DOOR SCHEDULE
LAYOUT WORK POINT
ALIGN NEW WALL SURFACE WITH EXISTING
CONSTRUCTION
This sheet is intended as a general information sheet only.
All items shown may not be included within this document set. Refer to plans, elevations, and /or details for specific items that are referenced.
NOTE:
Elevation identification
Drawing where elevation is drawn
Sheet where section is drawn
Section identification
Section identification
Detail identification
Sheet where section is drawn
Window number
Project North
Drawing descriptor
Drawing scale
Drawing indicator
Height above set datum
Column identification
Partition type identification
Floor indicator
Actual North (If Required)
Detail Symbols
Section Bubbles
Building Section Indicator
Elevation Indicator
Partition Type Indicator
Column Identification & Line
Datum Line
Section Title
North Symbol
Window Number
Room/ Space Number
A301
A301
OFFICE
2nd Floor Elevation 152'-0"
Room number
Room Name
9'-0" A.F.F.
Elevation Height indicator
EXISTING DOOR & FRAME TO BE REMOVED.
9'-0" A.F.F. CEILING HEIGHT INDICATOR
Sheet where detail came from
Sheet where detail is drawn
Drawing descriptor
Drawing Title
Drawing scale
Wall Section Scale: 3/4"=1'-0"
A701
First Floor Plan Scale: 1/4"=1'-0"
B Material type identification
REVISION BUBBLES
A204
A203
A203
A301 S102
2 3
A301
A302
Door number
Door Number
1'-0" IF DOOR HAS
CLOSER & LATCH
WHEEL CHAIR TURNING AREA
3' -0
4'
-0
5' -0
1'-6"
5' -0
X
X = 36" MIN. IF Y = 60"
X = 42" MIN. IF Y = 54"
Y = 54" MIN. IF DOOR
HAS A CLOSER
4' -0
Y)Y 2'-0"
DOORWAY CLEARANCES
1'-0"1'-0" 3'-0"
Barrier Free Clearances
60" DIA.
Y = 48" MIN. IF DOOR
HAS A CLOSER
3' -6
Y) 2'-0"
Top of Fin. Floor or Grade
Barrier Free Single Occupancy Toilet Rooms
Top of Fin. Floor or Grade
Mounting Heights General Layout PER ICC/ANSI A117.1 2009 EDITION
1. REQUIRED ACCESSIBLE TOILET FACILITIES SHALL COMPLY
WITH MICHIGAN BARRIER FREE CODE, ICC / ANSI-A 117.1 2009
AND THE MICHIGAN PLUMBING CODE.
2. PROVIDE BARRIER FREE ACCESSIBLE TOILET ROOM FOR MEN
AND WOMEN WITH A 32" MINIMUM CLEAR DOOR OPENING
3. WATER CLOSET MUST BE LOCATED 18" TO THE CENTERLINE
FROM THE ADJACENT WALL: THE SEAT MUST BE 17" ABOVE
FINISH FLOOR AND FLUSH CONTROLS NOT HIGHER THAN 36"
A.F.F. MAXIMUM WATER TEMPERATURE AT HAND SINKS.
4. SHALL NOT EXCEED 110 DEGREES FAHRENHEIT. FAUCETS
SHALL BE ADA LEVER OR PUSH-BUTTON TYPE. EXPOSED
WATER & DRAIN LINES TO BE INSULATED.
5. TOILET ROOM ACCESSORIES SHALL BE MOUNTED WITH THE
CONTROLS NO MORE THAN 48" ABOVE THE FLOOR. MIRRORS
SHALL BE INSTALLED NO MORE THAN 40" ABOVE THE FLOOR.
6. PROVIDE SIGNS SHOWING GENDER AND THE INTERNATIONAL
SYMBOL FOR THE HANDICAPPED ON THE EXTERIOR OF THE
ROOM; INSTALL ADJACENT TO THE LATCH SIDE OF THE DOOR.
BARRIER FREE DESIGN NOTES
PER ICC/ANSI A117.1 2009 EDITION
Y = 48" AND X = 12" MIN.
IF DOOR HAS BOTH
LATCH & CLOSER
3' -6
Y)
1'-10" (X)
4'-10"
A b o v e g r a b b a r m a x back wall
Standard roll-in-type shower control and hand shower location
16" min
27" max
Standard roll-in-type shower control and hand shower location back wall end wall end wall m a x6" max
Control Location
48"
2 1/2" max
1/ 2" m a x
Mounting Heights are typical unless noted otherwise on drawings.
Mounting heights are based upon design standards and/ or ADA & Barrier Free Design requirements. It is intended that like devices be mounted at the same height throughout the entire project. Recessed devices in masonry walls may dictate a deviation (+/- 2") from these heights (when permitted by code) to allow the bottom or the top of the device to align with masonry coursing. Coordinate these deviations with the Architect/ Owner.
Maximum heights as indicated on drawings shall be adhered to for any fixtures and equipment refer to ANSI 308 and 309.
Maximum height as indicated on drawings shall be adhered to for controls and operable parts for equipment and appliances intended for operation by the occupants in a space refer to ANSI 309.
m in
42" 18" m in
30 " min.
7'-3" min.
m a x
2" m in
6" max36" min m in clear floor space
18" m in
Paper Towel/ Dispenser/
DISPOSAL
note:
TURNING RADIUS
CAN EXTEND
UNDER LAV. UP
TO 19" MAX
TRASH CAN
ADA SIGN
note:
CHASE VARIES BY WALL
MATERIAL & FIXTURE COUNT
m in m a x
Sign mount height m a x
Diaper changing station b
.f s t a n d a r d
Hand Dryer
6" max
16"-18"
8" m in
12" max42" min
39" - 41"
1"
M
IN
.12" min24" min
36" min
42" max
24" min
1/ 2"
1/ 2"
ADA water closet
Protruding Dispenser(s) grab bar
Protruding Dispenser(s)
1-1/2" grab bars to seat hgt. to seat hgt.
ADA
WATER
CLOSET
m a x m a x m in m a x mirror in stainless stl.
frame soap dispenser wall mounted sink insulation on all exposed piping
Mop Strip & Shelf m in m a x b .f s t a n d a r d
Shelf m a x b
.f s t a n d a r d m in b .f
.c le a r
E.W.C. / Drinking Fountain m a x b
.f s t a n d a r d m a x m a x m a x b
.f s t a n d a r d
36" min Towel Bar Urinal
Coat Hook
M A X
All containers and miscellaneous wall mount items max. operable hgt.
BRIAN S. GILL - MICHIGAN LICENSE NUMBER: 44896
DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE:
PROJECT INFORMATION
SCOPE OF WORK
THIS PROJECT INVOLVES A TOILET/SHOWER BUILDING
OCCUPANT LOAD (TABLE 1004.1.2)
OCCUPANT LOAD
TOILET AND SHOWER ROOMS: 833 S.F. / 50 = 17
UTILITIES AND STORAGE AREA : 268 S.F. / 300 = 1
TOTAL: = 18
BUILDING TABULATION & CODE INFORMATION:
BASED 2015 MICHIGAN BUILDING CODE
2015 MICHIGAN PLUMBING CODE
2015 MICHIGAN MECHANICAL CODE
2014 MICHIGAN ELECTRIC CODE (incorporating 2017 nec)
BARRIER FREE DESIGN ICC/ANSI A117.1-2010
PROPOSED USE GROUP b
BUILDING AREAS
UTILITIES AND STORAGE AREA 268 S.F.
TOILET/SHOWER ROOMS 833 S.F.
TOTAL AREA 1101 S.F.
CONSTRUCTION TYPE: V B (602)
AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13 NO
HEIGHT MODIFICATIONS N.A. 0
ALLOWABLE HEIGHT (TABLE 504.3)
B / IIB = 40'
ALLOWABLE NUMBER OF STORIES (TABLE 504.4)
B / II B = 2 STORY
ALLOWABLE BUILDING AREA factor (TABLE 506.2) b / IIb = 9,000 s.f.
fire separation of occupancies (table 508.4) N.A.
frontage increase (506.3)
FIRE RESISTANCE RATING REQUIREMENTS TYPE V B (TABLE 601)
STRUCTURAL FRAME 0 HR
EXT. BEARING WALLS 0 HR
INT. BEARING WALLS 0 HR
NON-BEARING EXT WALLS 0 HR
NON-BEARING INT. WALLS 0 HR
FLOOR CONSTRUCTION 0 HR
ROOF CONSTRUCTION 0 HR
EXITS
BASED ON MAX OCCUPANT LOAD OF 15 (1006)
REQUIRED DOOR WIDTH: 32" (1005)
NUMBER OF EXITS: 2 (1006)
COMMON PATH OF TRAVEL: 100' (table 1006.2.1) EXIT ACCESS TRAVEL DISTANCE: 200' (table 1017.2)
CORRIDOR WIDTH: 36" (1020)
DEAD END CORRIDOR: NA (1020.4)
GENERAL NOTES
SCALE: NONE
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
R
EV
IE
W
D
AT
E
-0
BS
G
M
EH
C
IV
IL
E
N G
IN
EE
R
TD
G
-9
.0
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
ST
R
AI
TS
S
TA
TE
P
AR
K
SH
O
W
ER
B U
IL
D
IN
G
IM
PR
O
VE
M
EN
TS
ST
. I G
N
AC
E M
AC
KI
N C
C O
U N
TY
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
Ph as e
- 5
0%
/1 /2
Ph as e
- 9
0%
/5 /2
Ph as e
- B id D oc um en ts
5/
/2
M O
U N
TI
N
G H
EI
G
H
TS
A N
D G
EN
ER
AL
N
O
TE
S C
S
AutoCAD SHX Text D
AutoCAD SHX Text
NF
AutoCAD SHX Text
ENGINEERS
AutoCAD SHX Text Civil Engineers Land Surveyors Land Planners
AutoCAD SHX Text 46777 Woodward Avenue Pontiac, MI 48342-5032 Tel. (248) 332-7931 Fax. (248) 332-8257
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
PORCH A
1'-4"10'-4"1'-4" 1'-4"1'-4" 10'-4" 5'-8"
8" 3'-4"3'-0"3'-4" 3'-4" 8"3'-4"
1'-
24'-0"
1'-
8"
1'-
7' -8
9'-8"
5'-0"
1'-
1'-
1'-4" 1'-4"10'-4" 1'-4"10'-4"
24'-8"
3'-4" 5'-4"7'-4" 3'-4"
7'-4"
3'-0"
7'-4"
2' -8
31'-4"
2' -8
1'-
2' -8
1'-
1'-
7'-4"
2' -0
1'-
8" 8"7'-4"
2' -8
1'-
1'-
2' -8
1'-
1'-
1'-
2' -0
1'-
1'-
2' -8
1'-
2' -8
1'-
2' -8
1'-
1'-
" 5'-8" 4'-8" 4'-8" 8" 5'-8"
3'-4" 8"
8"
24'-0"
7' -0
4"
6'-0" 1'-4"
1'-8"
3'-4"
1'-8"
1'-
7'-0"
1'- 2"
3'-4"
8"
1'-
1'-
1'-
1'-
PORCH B
PORCH C
MEN'S
WOMEN'S
FAMILY/ADA
LAVATORY
ADA UNISEX
SHOWER
UNISEX
SHOWER
UNISEX
SHOWER
F.D.
H.B.
3" F.D.
3 33
TYP.
106B
110 109 108 107
106A104 105
A
B
B
B
B
15 18
6 9
F.D.
F.D. F.D.F.D.F.D.
F.D.
F.D.
F.D.
F.D.
F.D.
F.D.
F.D.
F.D.
F.D.
F.D.
A401
A 4
A 4
A4
B
B
B
A4
A4
A401
1 1
3 3 3
20 20
28 28
29 29
34343434
A401
A4
F.D.
F.D.
TYP.
ADA UNISEX
SHOWER
UTILITIES AND
STORAGE ROOM
CJ
CJ
CJ
CJCJ
CJ
CJ
0"
0"
0"0"
0"
0"
0"
0" 0"
-.83"
0" 0"
0"
0"
0"
0"
0"
0"
0"
0"
0"
0"
0"
0"
0"
-.37"
-.95"
-1.08"
-.75"
-.83"
0"
-.89"
0"
0"
-.91" min.
4" / ft.
(typ.)
m in
1/ f t
(t y p m in
1/ f t
(t y p
0"
0"
30 30
4"
0"
0"
0"
0"
0"
0"
0"
0"
0"
0" 0"
0"
0"
0" 0"
0"
0"
0"
0"
0" 0"
-.37"
30 30
303030
30 30 30 30 m in
1/ f t
(t y p min.
1/4" / ft.
(typ.)
min.
1/4" / ft.
(typ.)
m in
1/ f t
(t y p m in
1/ f t
(t y p
313131
A401
-.37" -.37"
-.66"-.58"-.66" -.58"
30 30 30
-.89"
-1.08"
-1.08"
A401
0"-.91"
-.75"
7' -0
2' -4
E S201
1 6"x6" SOLID CEDAR WOOD COLUMN
ON 16" X 16" MASONRY COLUMN BASE
AND PRE-CAST CAP. STAIN WOOD
COLUMN. see det. #c/s201.
4" REINFORCED CONCRETE SLAB
SIDEWALK. SLOPE SIDEWALK AWAY
FROM BUILDING AT MIN. 1/4" PER 1'-0".
ALUMINUM DOOR AND FRAME.
ALUMINUM WINDOW UNIT see sheet a601 for more information.
DRINKING FOUNTAINS, provide 1/4" STEEL mounting plate on inside matching exterior mounting plate.
wall mounted hand dryer MOUNTED ON 1/4" solid surface splash guard.
18" X 36" wall mounted mirror. 1 per sink (typ.)
SOLID SURFACE COUNTERTOP WITH
SPLASH AND integrally sinks SEE
DET. #6/A401.
soap dispensers.
wall hooks SEE INTERIOR ELEVATIONS a501 FOR LOCATIONS
AND MOUNTING HEIGHTS.
toilet partitions.
WALL MOUNTED URINAL.
WALL MOUNTED URINAL SCREEN.
FLOOR MOUNTED TOILET.
toilet paper dispenser mounted To wall or partition.
36" horizontal grab bar.
42" horizontal grab bar.
18" vertical grab bar.
fold-up wall mounted changing table. mount 34" max. to top of table surface
Sharp OBJECT DISPOSAL - WALL
MOUNTED.
SANITARY NAPKIN DISPENSER - WALL
MOUNTED.
wall mounted HOSE REEL.
WALL MOUNTED MOP RACK AND
SHELF. MOUNT SHELF 6'-0" A.F.F. TO
TOP OF SHELF.
MOP SINK.
barrier free roLL-in shower seat.
48" horizontal grab bar.
30" GRAB BAR
36" X 12" WALL MOUNTED STAINLESS
STEEL FIXED BENCH with perforated top.
24" horizontal towel bar. mount at 36" a.f.f.
CONTROL JOINT. reference detail on s101.
4" REINFORCED CONCRETE ON
COMPACTED BASE. PROVIDED
POSITIVE DRAINAGE TO FLOOR
DRAINS.
INDICATES LINE OF 12" CONCRETE
BLOCK FOOTING wall BELOW.
indicates line of 8" concrete block wall.
INDICATES WALL MOUNTED SHOWER
UNIT. see sheet a501 for height
STAINLESS STEEL SINK - REFER TO
PLUMBING PLANS
floor mounted water heater.
CONSTRUCTION NOTES
A. all dimensions are from face of block to face of block or faced of finished material to face of finished material..
B. FOR MOUNTING HEIGHTS REFER TO INTERIOR
ELEVATIONS AND SHEET CS101.
C. refer to sheet a601 for accessories schedule. GENERAL CONTRACTOR TO
INSTALL ALL OWNER SUPPLIED ITEMS.
D. all exposed concrete block corners to be bullnose as indicated on plans. if block does not come with bullnose corners then bullnose will need to be completed in field to match standard CMu Bullnose.
E. grout block solid below grade to first course above grade, above all openings, top course and at mounting locations for bench's and changing table.
F. concrete block headers are to be lintel block or concrete lintel. bottom face to be solid.
G. general contractor to require the coordination between all trades to provide a proper floor finish and drainage.
GENERAL NOTES
WALL TYPES
8" insulated CONCRETE BLOCK W/ #4 @ 40"
O.C. HORIZ WITH HORIZ REINFORCING @ 16" O.C.
VERT.(OMNI Block), SEE DETAILS SHT. S301 (SEE
EXTERIOR ELEVATIONS FOR FINISHES)
REFER TO SHEET A601
WINDOW TYPES
2 8" CONCRETE BLOCK W/ #4 @ 40" O.C. HORIZ
WITH HORIZ REINFORCING @ 16" O.C. VERT.
(INTERIOR WALLS)
A
REFER TO SHEET A601B
EXTERIOR BRICK
REFER TO PROJECT SPECIFICATIONS FOR
MORE INFORMATION
Floor slopes to floor drains are to meet the requirements of the Michigan Plumbing Code and the American with Disabilities Act. Positive water drainage to drain be maintained and accessibility considerations are to be met to the best of the contractor's ability
Slope percentages and distance of fall shown on drawings are approximate and field conditions will alter these dimensions and slope percentages. Floor conditions to be confirmed in field by the general contractor and sub-contractor to verify that the code requirements are met. Any discrepancies shall be identified, and the Owner's project representative notified prior to any floor grinding.
Michigan Plumbing Code requires shower floors to be sloped (2-percent slope) per IPC 416.5.2
ADA requirements that maximum cross slope is 1:48 (2-percent slope) per ICC A117.1-2009 Section 403.3
Notes Regarding Floor Slab Sloping to Drains
FLOOR PLAN
SCALE: 1/4"=1'-0"
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
R
EV
IE
W
D
AT
E
-0
BS
G
M
EH
C
IV
IL
E
N G
IN
EE
R
TD
G
-9
.0
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
ST
R
AI
TS
S
TA
TE
P
AR
K
SH
O
W
ER
B U
IL
D
IN
G
IM
PR
O
VE
M
EN
TS
ST
. I G
N
AC
E M
AC
KI
N C
C O
U N
TY
PL
UR
IB
U
E S
U N U
M
C I
R C
U M
S P
I C
E
S I
Q U
E R E
I S
P E
N I
N S
U L
A M
A M
OE
N
A M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
Ph as e
- 5
0%
/1 /2
Ph as e
- 9
0%
/5 /2
Ph as e
- B id D oc um
/2
C O
N C
R
ET
E
SL
AB
P
LA
N
AN
D
F
LO
O R
P
LA
N W
ES
T
A1
W
CONCRETE SLAB PLAN
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
NF
AutoCAD SHX Text
ENGINEERS
AutoCAD SHX Text Civil Engineers Land Surveyors Land Planners
46777 Woodward Avenue Pontiac, MI 48342-5032 Tel. (248) 332-7931 Fax. (248) 332-8257
PORCH A
1'-4" 10'-4" 1'-4"1'-4" 1'-4"10'-4"5'-8"
8"3'-4" 3'-0" 3'-4"3'-4"8" 3'-4"
1'-
24'-0"
1'-
8"
1'-
7' -8
9'-8"
5'-0"
1'-
1'-
1'-4"1'-4" 10'-4"1'-4" 10'-4"
24'-8"
3'-4"5'-4" 7'-4"3'-4"
7'-4"
3'-0"
7'-4"
2' -8
31'-4"
2' -8
1'-
2' -8
1'-
1'-
7'-4"
2' -0
1'-
8"8" 7'-4"
2' -8
1'-
1'-
2' -8
1'-
1'-
1'-
2' -0
1'-
1'-
2' -8
1'-
2' -8
1'-
2' -8
1'-
1'-
5'-8"4'-8"4'-8"8"5'-8"
3'-4"8"
8"
24'-0"
7' -0
4"
6'-0"1'-4"
1'-8"3'-4"1'-8"
1'-
7'-0"
1'- 2"
3'-4"
8"
1'-
1'-
1'-
1'-
PORCH B
PORCH C
MEN'S
WOMEN'S
FAMILY/ADA
LAVATORY
ADA UNISEX
SHOWER
UNISEX
SHOWER
UNISEX
SHOWER
F.D.
H.B.
3" F.D.
2 1
33 3
7TYP.
7 TYP.
106B
110109108107
106A 104105
A
B
B
B
B
25 25
F.D.
F.D.F.D. F.D. F.D.
F.D.
F.D.
F.D.
F.D.
F.D.
F.D.
F.D.
F.D.
F.D.
F.D.
A4
A4
A 4
B
B
B
A 4
A 4
A401
1 1 1
34 34 34 34
A401
A 4
2 2
F.D.
F.D.
ADA UNISEX
SHOWER
UTILITIES AND
STORAGE ROOM
A401
CJ
CJCJ
CJ
CJ
CJ CJ
0"
0"
0" 0"
0"
0"
0"
0"0"
-.83"
0"0"
0"
0"
0"
0"
0"
0"
0"
0"
0"
0"
0"
0"
0"
-.37"
-.95"
-1.08"
-.75"
-.83"
0"
-.89"
0"
0"
-.91" min.
4" / ft.
(typ.)
m in
1/ f t
(t y p m in
1/ f t
(t y p
0"
0" c.j.
4"
0"
0"
0"
0"
0"
0"
0"
0"
0"
0"0"
0"
0"
0"0"
0"
0"
0"
0"
0"0"
-.37
30 30 30
30303030 m in
1/ f t
(t y p min.
1/4" / ft.
(typ.)
min.
1/4" / ft.
(typ.)
m in
1/ f t
(t y p m in
1/ f t
(t y p
31 31 31
A401
-.37"-.37"
-.66" -.58" -.66"-.58"
30 30
303030
-.89"
-1.08"
-1.08"
A401
0" -.91"
-.75"
7' -0
2' -4
1 6"x6" SOLID CEDAR hand hone
WOOD COLUMN ON 16" X 16" MASONRY
COLUMN BASE AND PRE-CAST CAP.
STAIN WOOD COLUMN. see det.
#c/s201.
4" REINFORCED CONCRETE SLAB
SIDEWALK. SLOPE SIDEWALK AWAY
FROM BUILDING AT MIN. 1/4" PER 1'-0".
ALUMINUM DOOR AND FRAME.
ALUMINUM WINDOW UNIT see sheet a601 for more information.
DRINKING FOUNTAINS, provide 1/4" STEEL mounting plate on inside matching exterior mounting plate.
wall mounted hand dryer MOUNTED ON 1/4" solid surface splash guard.
18" X 36" wall mounted mirror. 1 per sink (typ.)
SOLID SURFACE COUNTERTOP WITH
SPLASH AND integrally sinks SEE
DET. #6/A401.
soap dispensers.
wall hooks SEE INTERIOR ELEVATIONS a501 FOR LOCATIONS
AND MOUNTING HEIGHTS.
toilet partitions.
WALL MOUNTED URINAL.
WALL MOUNTED URINAL SCREEN.
WALL MOUNTED TOILET.
toilet paper dispenser mounted To wall or partition.
36" horizontal grab bar.
42" horizontal grab bar.
18" vertical grab bar.
fold-up wall mounted changing table. mount 34" max. to top of table surface
Sharp OBJECT DISPOSAL - WALL
MOUNTED.
SANITARY NAPKIN DISPENSER - WALL
MOUNTED.
wall mounted HOSE REEL.
WALL MOUNTED MOP RACK AND
SHELF. MOUNT SHELF 6'-0" A.F.F. TO
TOP OF SHELF.
MOP SINK.
barrier free roLL-in shower seat.
48" horizontal grab bar.
30" GRAB BAR
36" X 12" WALL MOUNTED STAINLESS
STEEL FIXED BENCH with perforated top.
24" horizontal towel bar. mount at 36" a.f.f.
CONTROL JOINT. reference detail on s101.
4" REINFORCED CONCRETE ON
COMPACTED BASE. PROVIDED
POSITIVE DRAINAGE TO FLOOR
DRAINS.
INDICATES LINE OF 12" CONCRETE
BLOCK FOOTING wall BELOW.
indicates line of 8" concrete block wall.
INDICATES WALL MOUNTED SHOWER
UNIT. see sheet a501 for height
STAINLESS STEEL SINK - REFER TO
PLUMBING PLANS
FLOOR MOUNTED WATER HEATER
CONSTRUCTION NOTES
A. all dimensions are from face of block to face of block or faced of finished material to face of finished material..
B. FOR MOUNTING HEIGHTS REFER TO INTERIOR
ELEVATIONS AND SHEET CS101.
C. refer to sheet a601 for accessories schedule. GENERAL CONTRACTOR TO
INSTALL ALL OWNER SUPPLIED ITEMS.
D. all exposed concrete block corners to be bullnose as indicated on plans. if block does not come with bullnose corners then bullnose will need to be completed in field to match standard CMu Bullnose.
E. grout block solid below grade to first course above grade, above all openings, top course and at mounting locations for bench's and changing table.
F. concrete block headers are to be lintel block or concrete lintel. bottom face to be solid.
G. general contractor to require the coordination between all trades to provide a proper floor finish and drainage.
GENERAL NOTES
WALL TYPES
8" insulted CONCRETE BLOCK W/ #4 @ 40" O.C.
HORIZ WITH HORIZ REINFORCING @ 16" O.C.
VERT.(OMNI Block), SEE DETAILS SHT. S301 (SEE
EXTERIOR ELEVATIONS FOR FINISHES)
REFER TO SHEET A601
WINDOW TYPES
2 8" CONCRETE BLOCK W/ #4 @ 40" O.C. HORIZ
WITH HORIZ REINFORCING @ 16" O.C. VERT.
(INTERIOR WALLS)
A
REFER TO SHEET A601B
EXTERIOR BRICK
REFER TO PROJECT SPECIFICATIONS FOR
MORE INFORMATION
Floor slopes to floor drains are to meet the requirements of the Michigan Plumbing Code and the American with Disabilities Act. Positive water drainage to drain be maintained and accessibility considerations are to be met to the best of the contractor's ability
Slope percentages and distance of fall shown on drawings are approximate and field conditions will alter these dimensions and slope percentages. Floor conditions to be confirmed in field by the general contractor and sub-contractor to verify that the code requirements are met. Any discrepancies shall be identified, and the Owner's project representative notified prior to any floor grinding.
Michigan Plumbing Code requires shower floors to be sloped (2-percent slope) per IPC 416.5.2
ADA requirements that maximum cross slope is 1:48 (2-percent slope) per ICC A117.1-2009 Section 403.3
Notes Regarding Floor Slab Sloping to Drains
FLOOR PLAN
SCALE: 1/4"=1'-0"
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
R
EV
IE
W
D
AT
E
-0
BS
G
M
EH
C
IV
IL
E
N G
IN
EE
R
TD
G
-9
.0
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
ST
R
AI
TS
S
TA
TE
P
AR
K
SH
O
W
ER
B U
IL
D
IN
G
IM
PR
O
VE
M
EN
TS
ST
. I G
N
AC
E M
AC
KI
N C
C O
U N
TY
PL
UR
IB
U
E S
U N U
M
C I
R C
U M
S P
I C
E
S I
Q U
E R E
I S
P E
N I
N S
U L
A M
A M
OE
N
A M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
Ph as e
- 5
0%
/1 /2
Ph as e
- 9
0%
/5 /2
Ph as e
- B id D oc um
/2
C O
N C
R
ET
E
SL
AB
P
LA
N
AN
D
F
LO
O R
P
LA
N
EA
ST
A1
E
CONCRETE SLAB PLAN
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
NF
AutoCAD SHX Text
ENGINEERS
AutoCAD SHX Text Civil Engineers Land Surveyors Land Planners
1 1
SLOPE 4/12
SLOPE 4/12
SLOPE 4/12
SLOPE 4/12
SLOPE 4/12
SLOPE 4/12
SLOPE 4/12
SLOPE 4/12
S
LO
P E
/1
S
LO
P E
/1
8 8
1'-
1'-
9 13
111111
9 9 9
9 9
111111
SLOPE 5.5/12
SLOPE 5.5/12
SLOPE 5.5/12
SLOPE 5.5/12
SLOPE 5.5/12
S
LO
P E
.5 /1
S
LO
P E
.5 /1
SLOPE 5.5/12
SLOPE 5.5/12 SLOPE 5.5/12
SLOPE 5.5/12
SLOPE 5.5/12
SLOPE 5.5/12SLOPE 5.5/12SLOPE 5.5/12
1 DASHED LINE INDICATES LINE OF BUILDING OR COLUMN BELOW
PRE-FINISHED snap seam METAL ROOFING with striations
ON SELF ADHESIVE ICE AND WATER SHIELD ON 5/8" OSB
SHEATHING. ICE AND WATER SHIELD ENTIRE ROOF AREA.
METAL DRIP EDGE.
RIDGE cap.
PLUMBING VENT PENETRATION, FLASH AND SEAL PER
ROOFING MANUFACTURER'S REQUIREMENTS. COORDINATE
EXACT LOCATION WITH PLUMBING CONTRACTOR - PAINT TO
MATCH ROOF COLOR. installed square to roof.
soffit - 1x TONGUE AND GROOVE SIDING, SECURED TO
UNDERSIDE OF ROOF FRAMING ABOVE.
5" 26 GA GALV. STEEL CORRUGATED DOWNSPOUT & GUTTER
W/ SPLASH GUARD
WATER HEATERS VENT PENETRATION, FLASH AND SEAL PER
ROOFING MANUFACTURER'S REQUIREMENTS. COORDINATE
EXACT LOCATION WITH PLUMBING CONTRACTOR - PAINT TO
MATCH ROOF COLOR. installed square to roof.
1x TONGUE AND GROOVE SIDING, SECURED TO UNDERSIDE OF
ROOF FRAMING ABOVE.
1/2" plywood on 2x10 roof rafter with faced r-30 (9 1/2") insulation between rafters.
indicates column below.
RIDGE board install matching trim to cover ridge board.
VALLEY FLASHING PER MANUFACTURES RECOMMENDATIONS.
LVL'S WRAPPED WITH CEDAR BOARDS
Surface MOUNTED LIGHT FIXTURE WITH CONCEALED WIRING
KEY NOTES
5" 26 GA GALV. STEEL
CORRUGATED
DOWNSPOUT & GUTTER
W/ SPLASH GUARD-
color by owner.
grade secure downspout to 36" steel round survey stake.
(color to match gutter) refer to civil drawings for more information.
REFLECTED CEILING PLAN
SCALE: 1/4"=1'-0"
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
R
EV
IE
W
D
AT
E
-0
BS
G
M
EH
C
IV
IL
E
N G
IN
EE
R
TD
G
-9
.0
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
ST
R
AI
TS
S
TA
TE
P
AR
K
SH
O
W
ER
B U
IL
D
IN
G
IM
PR
O
VE
M
EN
TS
ST
. I G
N
AC
E M
AC
KI
N C
C O
U N
TY
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
Ph as e
- 5
0%
/1 /2
Ph as e
- 9
0%
/5 /2
Ph as e
- B id D oc um
/2
ROOF PLAN
SCALE: 1/4"=1'-0"
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
AN
D
R O
O F
PL
AN
W
ES
T A2
W
GUTTER AND DOWNSPOUT DETAIL
NOT TO SCALE
AutoCAD SHX Text
NF
AutoCAD SHX Text
ENGINEERS
AutoCAD SHX Text Civil Engineers Land Surveyors Land Planners
AutoCAD SHX Text 46777 Woodward Avenue Pontiac, MI 48342-5032 Tel. (248) 332-7931 Fax. (248) 332-8257
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
1 1
1'-
1'-
11 11 11
11 11 11
SLOPE 5.5/12
SLOPE 5.5/12
SLOPE 5.5/12
SLOPE 5.5/12
SLOPE 5.5/12
S
LO
P E
.5 /1
S
LO
P E
.5 /1
SLOPE 5.5/12
SLOPE 5.5/12SLOPE 5.5/12
SLOPE 5.5/12
SLOPE 5.5/12
SLOPE 5.5/12 SLOPE 5.5/12 SLOPE 5.5/12
1 DASHED LINE INDICATES LINE OF BUILDING OR COLUMN BELOW
PRE-FINISHED snap seam METAL ROOFING with striations
ON SELF ADHESIVE ICE AND WATER SHIELD ON 5/8" OSB
SHEATHING. ICE AND WATER SHIELD ENTIRE ROOF AREA.
METAL DRIP EDGE.
RIDGE cap.
PLUMBING VENT PENETRATION, FLASH AND SEAL PER
ROOFING MANUFACTURER'S REQUIREMENTS. COORDINATE
EXACT LOCATION WITH PLUMBING CONTRACTOR - PAINT TO
MATCH ROOF COLOR. installed square to roof.
soffit - 1x TONGUE AND GROOVE SIDING, SECURED TO
UNDERSIDE OF ROOF FRAMING ABOVE.
5" 26 GA GALV. STEEL CORRUGATED DOWNSPOUT & GUTTER
W/ SPLASH GUARD
WATER HEATERS VENT PENETRATION, FLASH AND SEAL PER
ROOFING MANUFACTURER'S REQUIREMENTS. COORDINATE
EXACT LOCATION WITH PLUMBING CONTRACTOR - PAINT TO
MATCH ROOF COLOR. installed square to roof.
1x TONGUE AND GROOVE SIDING, SECURED TO UNDERSIDE OF
ROOF FRAMING ABOVE.
1/2" plywood on 2x10 roof rafter with faced r-30 (9 1/2") insulation between rafters.
indicates column below.
RIDGE board install matching trim to cover ridge board.
VALLEY FLASHING PER MANUFACTURES RECOMMENDATIONS.
LVL'S WRAPPED WITH CEDAR BOARDS
Surface MOUNTED LIGHT FIXTURE WITH CONCEALED WIRING
KEY NOTES
5" 26 GA GALV. STEEL
CORRUGATED
DOWNSPOUT & GUTTER
W/ SPLASH GUARD-
color by owner.
grade secure downspout to 36" steel round survey stake.
(color to match gutter) refer to civil drawings for more information.
REFLECTED CEILING PLAN
SCALE: 1/4"=1'-0"
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
R
EV
IE
W
D
AT
E
-0
BS
G
M
EH
C
IV
IL
E
N G
IN
EE
R
TD
G
-9
.0
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
ST
R
AI
TS
S
TA
TE
P
AR
K
SH
O
W
ER
B U
IL
D
IN
G
IM
PR
O
VE
M
EN
TS
ST
. I G
N
AC
E M
AC
KI
N C
C O
U N
TY
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
Ph as e
- 5
0%
/1 /2
Ph as e
- 9
0%
/5 /2
Ph as e
- B id D oc um
/2
ROOF PLAN
SCALE: 1/4"=1'-0"
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
AN
D
R O
O F
PL
AN
EA
ST
A2
E
GUTTER AND DOWNSPOUT DETAIL
NOT TO SCALE
AutoCAD SHX Text
NF
AutoCAD SHX Text
ENGINEERS
AutoCAD SHX Text Civil Engineers Land Surveyors Land Planners
AutoCAD SHX Text 46777 Woodward Avenue Pontiac, MI 48342-5032 Tel. (248) 332-7931 Fax. (248) 332-8257
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A break metal fascia.
6x6 column limestone cap.
SPLIT FACE CMU
(1) course smooth face concrete block.
snap seam metal roof (beyond).
sink with side board.
(beyond).
alum. door and frame.
SPLIT FACE CMU
110109108107 break metal bevel cedar siding
GALV. METAL GUTTER AND
DOWNSPOUT.
6X6 POST
5 1/2
5 1/2
M.L. WRAPPED WITH 1X
CEDAR.
SPLIT FACE conc. block.
1X4 cedar TRIM
C .J
C .J
DOWNSPOUT, SEE DETAIL
A201
6x6 column limestone cap.
SPLIT FACE CMU
snap seam metal roof break metal
6x6 column limestone cap.
SPLIT FACE CMU
alum. window with vent.
snap seam metal roof
(1) concrete smooth face conc. block.
106B
AAA BBBB
break metal split face conc. Block.
C .J snap seam metal roof (beyond).
limestone cap.
SPLIT FACE CMU
snap seam metal roof (beyond).
6x6 column limestone cap.
SPLIT FACE CMU
wall mounted sink with backsplash. mounted on smooth face block alum. windows.
111B B B A AA
split face concrete block.
electrical outlet w/ locking cover break metal
A
WOOD VENT WITH
EXTERIOR INSECT SCREEN.
GALV. METAL GUTTER AND
DOWNSPOUT.
5 1/25 1/2 12 12 m.l. wrapped with rough sawn cedar.
(1) course smooth face concrete block.
bevel cedar siding
1X4 TRIM
C .J break metal fascia
6x6 column limestone cap.
SPLIT FACE CMU
snap seam metal roof (beyond).
WOOD LOUVER wall vent.
with removable screen (beyond).
smooth conc. block.
wall sink (beyond).
hi/lo drink fountains mounted on smooth concrete block conc. block.
SPLIT FACE CONCRETE
BLOCK.
104 106A 105
M.L. WRAPPED WITH 1X
ROUGH SAWN CEDAR.
5 1/2 5 1/2
Alum. door bevel cedar siding
1X4 TRIM
break metal fascia simpson beam to column ties APVl4 or approved equal (typ.)
simpson beam to column ties APVt4 or approved equal (typ.)
C .J aluminum window unit- refer to window schedule double 2X8 top plate
1X wood trim - flush or proud of block.
tongue and groove wood siding concrete masonry bond beam
BREAK METAL
5/8" roof sheathing
2X10 rafter framing @ 16" o.c.
bird mouth at top plate ice and water shield pre-finished metal roofing
5 1/2 hurricane ties at each rafter
CONT. 2X10
R-30 (9 1/2") FACED
FIBERGLASS INSULATION.
1/2" anchor bolts @ 6'-0" o.c. or straps per manf. requirements.
CONTINUOUS SEALANT
each side aluminum window unit
- refer to window schedule
2x pt blocking set in solid grout.
8" concrete masonry unit slope 1/8"/ft
BULLNOSE EDGE CMU
ON INSIDE
break metal secured under window. fully adheared (match window color) aluminum window unit continuous sealant typical each side cont. #4 reinf. grout solid. (typ.)
8" concrete masonry jamb unit at all openings. W/ BULL
NOSE CORNER ON INSIDE
PROVIDE bullnose EDGE aluminum threshold aluminum door and frame continuous sealant typical each side
8" concrete masonry jamb unit at all openings. W/ BULL
NOSE CORNER ON INSIDE
cont. #4 reinf. grout solid. (typ.)
PROVIDE bullnose EDGE aluminum door and frame concrete lintel or lintel block with solid bottom.
WOOD LOUVER
W/ REMOVABLE INSECT
SCREEN
continuous sealant typical each side
SHIM AS NEEDED
bullnose edge.
METAL DUCT WORK.
SEAL PERIMETER
continuous sealant typical each side
1/2" anchor bolts @ 6'-0" o.c. or straps per manf. requirements.
concrete aluminum door and frame
2" expansion joint concrete masonry unit foundation wall refer to structural
REINFORCED CONCRETE
SLAB ON GRADE, REFER
TO STRUCTURAL
sweep
INTERIOREXTERIOR
PROVIDE bullnose EDGE
ALUMINUM THRESHOLD
EAST ELEVATION
SCALE: 1/4"=1'-0"
NORTH ELEVATION
SCALE: 1/4"=1'-0"
SOUTH ELEVATION
SCALE: 1/4"=1'-0"
WEST ELEVATION
SCALE: 1/4"=1'-0"
EX
TE
R
IO
R E
LE
VA
TI
O
N S
AN
D
D
ET
AI
LS
W
ES
T A3
W
2 WINDOW SILL
SCALE: 1-1/2"=1'-0"A301 A301
1 WINDOW HEAD
SCALE: 1-1/2"=1'-0"A301 A301
3 WINDOW JAMB
SCALE: 1-1/2"=1'-0"A301 A301
4 DOOR JAMB
SCALE: 1-1/2"=1'-0"A301 A301
5 DOOR HEAD
SCALE: 1-1/2"=1'-0"A301 A301
6 DOOR THRESHOLD
SCALE: 1-1/2"=1'-0"A301 A301
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
R
EV
IE
W
D
AT
E
-0
BS
G
M
EH
C
IV
IL
E
N G
IN
EE
R
TD
G
-9
.0
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
ST
R
AI
TS
S
TA
TE
P
AR
K
SH
O
W
ER
B U
IL
D
IN
G
IM
PR
O
VE
M
EN
TS
ST
. I G
N
AC
E M
AC
KI
N C
C O
U N
TY
PL
UR
IB
U
E S
U N U
M
C I
R C
U M
S P
I C
E
S I
Q U
E R E I
S P
E N
I N
S U
L A
M A
M
OE
N A
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
Ph as e
- 5
0%
/1 /2
Ph as e
- 9
0%
/5 /2
Ph as e
- B id D oc um
/2
AutoCAD SHX Text
3'-4" A.F.F. @ TYPE B
AutoCAD SHX Text
6'-0" A.F.F. @ TYPE A
AutoCAD SHX Text 7'-4" A.F.F.
AutoCAD SHX Text
NF
AutoCAD SHX Text
ENGINEERS
AutoCAD SHX Text Civil Engineers Land Surveyors Land Planners break metal
6x6 column limestone cap.
SPLIT FACE CMU
(1) course smooth face concrete block.
snap seam metal roof (beyond).
sink with side board.
(beyond).
alum. door and frame.
SPLIT FACE CMU
110 109 108 107 break metal bevel cedar siding
GALV. METAL GUTTER AND
DOWNSPOUT.
6X6 POST
5 1/2
5 1/2 m.l. wrapped with cedar.
SPLIT FACE conc. block.
1X4 cedar TRIM
C .J
C .J
8" dia. hand hone cedar log posts.
limestone cap.
SPLIT FACE CMU
snap seam metal roof
BREAK METAL
6x6 column limestone cap.
SPLIT FACE CMU
alum. window with vent.
snap seam metal roof
(1) concrete smooth face conc. block.
106B
BREAK METAL
split face conc. Block.
A A AB B B B
C .J
C .J snap seam metal roof (beyond).
limestone cap.
SPLIT FACE CMU
snap seam metal roof (beyond).
6x6 column limestone cap.
SPLIT FACE CMU
wall mounted sink with backsplash. mounted on smooth face block alum. windows.
split face concrete block.
electrical outlet w/ locking cover
BREAK METAL
WOOD VENT WITH
EXTERIOR INSECT SCREEN.
GALV. METAL GUTTER AND
DOWNSPOUT.
5 1/2
5 1/2 m.l. wrapped with rough sawn cedar.
(1) course smooth face concrete block.
bevel cedar siding
1X4 TRIM
BBBAA AA
C .J break metal fascia
6x6 column limestone cap.
SPLIT FACE CMU
snap seam metal roof (beyond).
WOOD LOUVER wall vent.
with removable screen (beyond).
smooth conc. block.
wall sink (beyond).
hi/lo drink fountains mounted on smooth concrete block conc. block.
SPLIT FACE CONCRETE
BLOCK.
104106A105
M.L. WRAPPED WITH 1X
ROUGH SAWN CEDAR.
5 1/2
5 1/2
Alum. door bevel cedar siding
1X4 TRIM
break metal fasica simpson beam to column ties APVl4 or approved equal (typ.)
simpson beam to column ties APVt4 or approved equal (typ.)
C .J
DOWNSPOUT, SEE DETAIL A201
aluminum window unit- refer to window schedule double 2X8 top plate
1X wood trim - flush or proud of block.
tongue and groove wood siding concrete masonry bond beam
BREAK METAL
5/8" roof sheathing
2X10 rafter framing @ 16" o.c.
bird mouth at top plate ice and water shield pre-finished metal roofing
5 1/2 hurricane ties at each rafter
CONT. 2X10
R-30 (9 1/2") FACED
FIBERGLASS INSULATION.
1/2" anchor bolts @ 6'-0" o.c. or straps per manf. requirements.
CONTINUOUS SEALANT
each side aluminum window unit
- refer to window schedule
2x pt blocking set in solid grout.
8" concrete masonry unit slope 1/8"/ft
BULLNOSE EDGE CMU
ON INSIDE
break metal secured under window. fully adheared (match window color) aluminum window unit continuous sealant typical each side cont. #4 reinf. grout solid. (typ.)
8" concrete masonry jamb unit at all openings. W/ BULL
NOSE CORNER ON INSIDE
PROVIDE bullnose EDGE aluminum threshold aluminum door and frame continuous sealant typical each side
8" concrete masonry jamb unit at all openings. W/ BULL
NOSE CORNER ON INSIDE
cont. #4 reinf. grout solid. (typ.)
PROVIDE bullnose EDGE aluminum door and frame concrete lintel or lintel block with solid bottom.
WOOD LOUVER
W/ REMOVABLE INSECT
SCREEN
continuous sealant typical each side
SHIM AS NEEDED
bullnose edge.
METAL DUCT WORK.
SEAL PERIMETER
continuous sealant typical each side
1/2" anchor bolts @ 6'-0" o.c. or straps per manf. requirements.
concrete aluminum door and frame
2" expansion joint concrete masonry unit foundation wall refer to structural
REINFORCED CONCRETE
SLAB ON GRADE, REFER
TO STRUCTURAL
sweep
INTERIOREXTERIOR
PROVIDE bullnose EDGE
ALUMINUM THRESHOLD
WEST ELEVATION
SCALE: 1/4"=1'-0"
SOUTH ELEVATION
SCALE: 1/4"=1'-0"
NORTH ELEVATION
SCALE: 1/4"=1'-0"
EAST ELEVATION
SCALE: 1/4"=1'-0"
EX
TE
R
IO
R E
LE
VA
TI
O
N S
AN
D
D
ET
AI
LS
EA
ST
A3
E
2 WINDOW SILL
SCALE: 1-1/2"=1'-0"A301 A301
1 WINDOW HEAD
SCALE: 1-1/2"=1'-0"A301 A301
3 WINDOW JAMB
SCALE: 1-1/2"=1'-0"A301 A301
4 DOOR JAMB
SCALE: 1-1/2"=1'-0"A301 A301
5 DOOR HEAD
SCALE: 1-1/2"=1'-0"A301 A301
6 DOOR THRESHOLD
SCALE: 1-1/2"=1'-0"A301 A301
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
R
EV
IE
W
D
AT
E
-0
BS
G
M
EH
C
IV
IL
E
N G
IN
EE
R
TD
G
-9
.0
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
ST
R
AI
TS
S
TA
TE
P
AR
K
SH
O
W
ER
B U
IL
D
IN
G
IM
PR
O
VE
M
EN
TS
ST
. I G
N
AC
E M
AC
KI
N C
C O
U N
TY
PL
UR
IB
U
E S
U N U
M
C I
R C
U M
S P
I C
E
S I
Q U
E R E I
S P
E N
I N
S U
L A
M A
M
OE
N A
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
Ph as e
- 5
0%
/1 /2
Ph as e
- 9
0%
/5 /2
Ph as e
- B id D oc um
/2
AutoCAD SHX Text
3'-4" A.F.F. @ TYPE B
AutoCAD SHX Text
6'-0" A.F.F. @ TYPE A
AutoCAD SHX Text 7'-4" A.F.F.
AutoCAD SHX Text
NF
AutoCAD SHX Text
ENGINEERS
AutoCAD SHX Text Civil Engineers Land Surveyors Land Planners
5.5
12" CONC. BLOCK
FOUNDATION WALL.
12" X 24" STRIP FOOTING.
8" split face omni CONC.
BLOCK
METAL ROOFING ON ice and water shield ON 5/8" Roof SHEATHING ON 2x10
RAFTERS @ 16" O.C.
(2) 2x8 top plates.
BREAK METAL
2x10 rim board.
4" POLISHED AND SEALED
concrete slab. see a101 for slope solid surface counter top with integral sink.
1x T&G mich. white cedar paneling on 2x4 @ 16" o.c.
aluminum door and frame.
WD LOUVER vent with removable insect screen (beyond). vent to be covered with duct work and sheet metal. (frame per order vent.) min. size 35w x 38h with 5/12 slope.
1x T&G mich. white cedar paneling. on ceiling.
OPP
A401
A301
A301
A401 hurricane ties at each rafter
2x12 RIDGE BOARD WITH
SIMPSON STRONG TIE: LRU28Z
AT EACH 2X10 RAFTER.
2x10 blocking AT 1/3 points 8' O.C. max.
paint exposed wood.
OPP
1/2" plywd. underside of rafters (paint).
r-30 faced fiberglass insulation.
split face block grout solid.
2x8 top plate.
8" CONC. BLOCK.
8" SMOOTH FACE CMU
8" SMOOTH FACE CMU
8" SMOOTH FACE CMU8" SMOOTH FACE CMU
8" SMOOTH FACE CMU
8" SMOOTH FACE CMU
2X4 @ 16" O.C. STAGGERED
STUD WALL FLUSH W/ BLOCK
BOTH SIDES
6"x6" post
1x T&G mich. white cedar paneling secured to roof rafters.
aluminum door bevel cedar siding break metal fascia 2x10 RAFTERS @ 16" O.C.
cedar trim.
2x top plate beyond.
2X4 LOOKOUTS @ 24' O.C.
1x rough sawn wood trim over (2) 5 1/2" m.l. -provide chase for electrical wiring for lightings.
slope top 1/4"/ft.
1x T&G mich. white cedar paneling secured 2x4 @ 16" o.c.
3x4 rough sawn cedar trim.
r-30 face fiberglass insulation.
column base see detail #c sht. s201 for more information.
hanger beyond for m.l.
SIMPSON STRONG TIE:
WP3.12X SPECIAL ORDER
E S201
METAL ROOFING ON ICE
WATER SHIELD ON 5/8" ROOF
SHEATHING ON 2x10
RAFTERS @ 16" O.C.
2X4 @ 16" O.C. STAGGERED
STUD WALL FLUSH W/ BLOCK
BOTH SIDES
2x top plate beyond.
continuous sealant where mop sink abuts wall mop sink, refer to plumbing plans.
CONCRETE SLAB -
REFER TO
FOUNDATION PLAN
8" c.m.u. wall
4" SOLID SURFACE
BACKSPLASH.
SEALANT.
3/4" EXTERIOR
GRADE PLYWD.
SUBSTRATE
hAFELE WORK
SURFACE BRACKETS,
HEBGO, STEEL
(287.44.961) pipe insulation kit.
1/4" plate with thru bolts.
NOTE:
INSTALL PER DETAIL
NO ALTERNATIVES.
1/4" EXPANSION JOINT
12X22 ex. DUCT
METAL ROOFING ON ice and water shield ON 5/8" Roof SHEATHING ON 2x10
RAFTERS @ 16" O.C.
1x4 rough sawn wood
TRIM.
2x4 box header.
8" omni CONC. BLOCK.
2X6 JOISTS @ 16" O.C.
ROOFING FOR GABLE
OVERLAY
2X4 GABLE END WALL
r-30 faced fiberglass insulation.
WOOD LOUVER WITH CUSTOM
REMOVAL EXTERIOR BUG
SCREEN.
(2) 1 3/4" X 7 1/4" M.L. RIDGE
UNISTRUT P1001 SECURED TO
UNIT AND UNISTRUT.
UNISTRUT P1001 BEARING on
AND SECURED TO BLOCK.
(CUT PLATE AS REQUIRED)
HORIZONTAL FURNACE.
energy recovery unit.
supported by uni-strut verify mounting with manf.
B S201
PLAN VIEW
CMU
2X4 P.T. WOOD
BLOCKING SET
IN SOLID GROUT
AT MOUNTING
LOCATIONS FOR
BENCHES.
grout solid
DRAINAGE
MATERIAL
PAN FLASHING
SYSTEM (WEEP
INSTALLED FLUSH)
INTEGRAL WATER
REPELLANT (IN CMU
AND MORTAR) AND
A POST-CLEANING
FIELD APPLIED
WATER REPELLANT
weeps @ 32" o.c.
min.
SELF LEVELING
CAULK
1/4" EXPANSION
JOINT
GROUT SOLID
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
R
EV
IE
W
D
AT
E
-0
BS
G
M
EH
C
IV
IL
E
N G
IN
EE
R
TD
G
-9
.0
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
ST
R
AI
TS
S
TA
TE
P
AR
K
SH
O
W
ER
B U
IL
D
IN
G
IM
PR
O
VE
M
EN
TS
ST
. I G
N
AC
E M
AC
KI
N C
C O
U N
TY
PL
UR
IB
U
E S
U N U
M
C I
R C
U M
S P
I C
E
S I Q
U E
RE
I
S P
E N
I N
S U
L A
M A
M
OE
N A
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
Ph as e
- 5
0%
/1 /2
Ph as e
- 9
0%
/5 /2
Ph as e
- B id D oc um
/2
1 BUILDING SECTION
SCALE: 1/2"=1'-0"A401 A101
BU
IL
D
IN
G S
EC
TI
O N
AN
D
D
ET
AI
LS
EA
ST
A N
D W
ES
T
7 SECTION AT PORCH A
SCALE: 1/2"=1'-0"A401 A101
8 SECTION AT PORCH B
SCALE: 1/2"=1'-0"A401 A101
5 FLASHING/WEEPS
SCALE: 1-1/2"=1'-0"A401 A401
6 COUNTER / MOP SINK CURB
SCALE: 1-1/2"=1'-0"A401 A101
A4
W
9 BENCH / SHOWER / ETC.
SCALE: 1-1/2"=1'-0"A401 A401
TYP. WALL BLOCKING DETAIL /
AutoCAD SHX Text
NF
AutoCAD SHX Text
ENGINEERS
AutoCAD SHX Text Civil Engineers Land Surveyors Land Planners mI. white cedar alum. door smooth face conc. block mI. white cedar alum. door smooth face conc. block mI. white cedar t&g.
on wood frame smooth face conc. block mI. white cedar t&g.
on wood frame wall mounted light fixtures pre finish smooth face conc. block 18"x36" frameless MIRRORS
18"x36" framless MIRRORS mI. white cedar t&g.
on wood frame wall mounted light fixtures smooth face conc. block mI. white cedar t&g.
on wood frame smooth face conc. block
CHANGING TABLE
CHANGING TABLE
mI. white cedar t&g.
on wood frame smooth face conc. block mI. white cedar t&g.
on wood frame smooth face conc. block mI. white cedar t&g.
on wood frame smooth face conc. block
18" X 36" MIRROR
mI. white cedar t&g.
on wood frame smooth face conc. block DOOR
CHANGING TABLE
wall mounted HAND DRYER on solid surface splash guard.
wall mounted
HAND DRYER
smooth face conc. block smooth face conc. block solid surface to match counter tops splash guard solid surface to match countertops splash guard
HOOKS MTD. JUST
BELOW WINDOW
HOOKS MTD. JUST
BELOW WINDOWS
HOOKS
HOOKS
smooth face conc. block alum. doors.
mI. white cedar t&g.
on wood frame mI. white cedar trim.
HAND DRYER
MOUNTED ON 1/4"
SOLID SURFACE
SPLASH GUARD.
surface mtd light fixture.
mI. white cedar t&g.
on wood frame smooth face conc. block
LIGHT BEYOND
METAL BENCH
48" GRAB BAR
18" GRAB BAR
SHOWER CONTROLS
solid surface to match counter tops splash guard supply diffuser return diffuser
SHARP OBJECTS
DISPOSAL
NAPKIN DISPOSAL
SHARPS
OBJECT
DISPOSAL
NAPKIN
DISPOSAL
SHARPS OBJECT
DISPOSAL
mI. white cedar t&g.
on wood frame smooth face conc. block mI. white cedar t&g.
on wood frame smooth face conc. Block
METAL BENCH
HOOKS
METAL BENCH
HOOKS
TOWEL RACK
TOWEL
RACK
30" GRAB
BAR
SUPPLY GRILLE
RETURN GRILLE
HOOK
folding SHOWER seat
SOAP DISPENSER
TOILET PARTITIONS
SEE SHEET CS101 FOR
ADA MOUNTING HGTS.
SEE SHEET CS101 FOR
ADA MOUNTING HGTS.
TOILET PARTITIONS
SOAP DISPENSER
SOAP
DISPENSER
folding SHOWER seat
LIGHT
C .J
C .J
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
R
EV
IE
W
D
AT
E
-0
BS
G
M
EH
C
IV
IL
E
N G
IN
EE
R
TD
G
-9
.0
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
ST
R
AI
TS
S
TA
TE
P
AR
K
SH
O
W
ER
B U
IL
D
IN
G
IM
PR
O
VE
M
EN
TS
ST
. I G
N
AC
E M
AC
KI
N C
C O
U N
TY
PL
UR
IB
U
E S
U N U
M
C I
R C
U M
S P
I C
E
S I Q
U E
R E I
S P
E N
I N
S U
L A
M A
M
OE
N A
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
Ph as e
- 5
0%
/1 /2
Ph as e
- 9
0%
/5 /2
Ph as e
- B id D oc um
/2
IN
TE
R
IO
R E
LE
VA
TI
O
N S
W
ES
T A5
W
1 ACCESSIBLE TOILET
SCALE: 1/4"=1'-0"A501 A601
2 ACCESSIBLE TOILET
SCALE: 1/4"=1'-0"A501 A601
3 ACCESSIBLE TOILET
SCALE: 1/4"=1'-0"A501 A601
4 ACCESSIBLE TOILET
SCALE: 1/4"=1'-0"A501 A601
5 SHOWER FRONT WALL
SCALE: 1/4"=1'-0"A501 A601
6 STANDARD SHOWER
SCALE: 1/4"=1'-0"A501 A601
7 STANDARD SHOWER
SCALE: 1/4"=1'-0"A501 A601
8 ADA SHOWER
SCALE: 1/4"=1'-0"A501 A601
9 ADA SHOWER
SCALE: 1/4"=1'-0"A501 A601
10 SHOWER BACKWALL
SCALE: 1/4"=1'-0"A501 A601
11 WOMEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601
12 WOMEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601
13 WOMEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601
14 WOMEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601
15 MEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601 16 MEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601
17 MEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601
18 MEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601
NOTE:
MASON & ELECTRICAL
CONTRACTOR TO
COORDINATE WORK TO
COORDINATE EMBEDDED
ELECTRICAL
AutoCAD SHX Text 6'-10"
AutoCAD SHX Text 6'-10"
AutoCAD SHX Text 6'-10"
AutoCAD SHX Text
NF
AutoCAD SHX Text
ENGINEERS
AutoCAD SHX Text Civil Engineers Land Surveyors Land Planners mI. white cedar alum. door smooth face conc. block mI. white cedar alum. door smooth face conc. block mI. white cedar t&g.
on wood frame smooth face conc. block mI. white cedar t&g.
on wood frame wall mounted light fixtures pre finish smooth face conc. block18"x36" frameless MIRRORS
18"x36" framless MIRRORS mI. white cedar t&g.
on wood frame wall mounted light fixtures smooth face conc. block mI. white cedar t&g.
on wood frame smooth face conc. block
CHANGING TABLE
CHANGING TABLE
mI. white cedar t&g.
on wood frame smooth face conc. block mI. white cedar t&g.
on wood frame smooth face conc. block mI. white cedar t&g.
on wood frame smooth face conc. block
18" X 36" MIRROR
mI. white cedar t&g.
on wood frame smooth face conc. block
DOOR
CHANGING TABLE
wall mounted HAND DRYER on solid surface splash guard.
wall mounted
HAND DRYER
smooth face conc. block smooth face conc. block solid surface to match counter tops splash guard solid surface to match countertops splash guard
HOOKS MTD. JUST
BELOW WINDOW
HOOKS MTD. JUST
BELOW WINDOWS
HOOKS
HOOKS
smooth face conc. block alum. doors.
mI. white cedar t&g.
on wood frame mI. white cedar trim.
HAND DRYER
MOUNTED ON 1/4"
SOLID SURFACE
SPLASH GUARD.
surface mtd light fixture.
mI. white cedar t&g.
on wood frame smooth face conc. block
LIGHT BEYOND
METAL BENCH
48" GRAB BAR
18" GRAB BAR
SHOWER CONTROLS
solid surface to match counter tops splash guard supply diffuser return diffuser
SHARP OBJECTS
DISPOSAL
NAPKIN DISPOSAL
SHARPS
OBJECT
DISPOSAL
NAPKIN
DISPOSAL
SHARPS OBJECT
DISPOSAL
mI. white cedar t&g.
on wood frame smooth face conc. block mI. white cedar t&g.
on wood frame smooth face conc. Block
LIGHT
METAL BENCH
HOOKS
METAL BENCH
HOOKS
TOWEL RACK
TOWEL
RACK
30" GRAB
BAR
SUPPLY GRILLE
RETURN GRILLE
HOOK
folding SHOWER seat
SOAP DISPENSER
TOILET PARTITIONS
SEE SHEET CS101 FOR
ADA MOUNTING HGTS.
SEE SHEET CS101 FOR
ADA MOUNTING HGTS.
TOILET PARTITIONS
SOAP DISPENSER
SOAP
DISPENSER
folding SHOWER seat
C .J
C .J
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
R
EV
IE
W
D
AT
E
-0
BS
G
M
EH
C
IV
IL
E
N G
IN
EE
R
TD
G
-9
.0
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
ST
R
AI
TS
S
TA
TE
P
AR
K
SH
O
W
ER
B U
IL
D
IN
G
IM
PR
O
VE
M
EN
TS
ST
. I G
N
AC
E M
AC
KI
N C
C O
U N
TY
PL
UR
IB
U
E S
U N U
M
C I
R C
U M
S P
I C
E
S I Q
U E
R E I
S P
E N
I N
S U
L A
M A
M
OE
N A
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
Ph as e
- 5
0%
/1 /2
Ph as e
- 9
0%
/5 /2
Ph as e
- B id D oc um
/2
IN
TE
R
IO
R E
LE
VA
TI
O
N S
EA
ST
A5
E
1 ACCESSIBLE TOILET
SCALE: 1/4"=1'-0"A501 A601
2 ACCESSIBLE TOILET
SCALE: 1/4"=1'-0"A501 A601
3 ACCESSIBLE TOILET
SCALE: 1/4"=1'-0"A501 A601
4 ACCESSIBLE TOILET
SCALE: 1/4"=1'-0"A501 A601
5 SHOWER FRONT WALL
SCALE: 1/4"=1'-0"A501 A601
6 STANDARD SHOWER
SCALE: 1/4"=1'-0"A501 A601
7 STANDARD SHOWER
SCALE: 1/4"=1'-0"A501 A601
8 ADA SHOWER
SCALE: 1/4"=1'-0"A501 A601
9 ADA SHOWER
SCALE: 1/4"=1'-0"A501 A601
10 SHOWER BACKWALL
SCALE: 1/4"=1'-0"A501 A601
11 WOMEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601
12 WOMEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601
13 WOMEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601
14 WOMEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601
15 MEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601 16 MEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601
17 MEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601
18 MEN'S RESTROOM
SCALE: 1/4"=1'-0"A501 A601
NOTE:
MASON & ELECTRICAL
CONTRACTOR TO
COORDINATE WORK TO
COORDINATE EMBEDDED
ELECTRICAL
AutoCAD SHX Text 6'-10"
AutoCAD SHX Text 6'-10"
AutoCAD SHX Text 6'-10"
AutoCAD SHX Text
NF
AutoCAD SHX Text
ENGINEERS
AutoCAD SHX Text Civil Engineers Land Surveyors Land Planners door number frame material type
106A alum a alum a alum a alum a alum a alum a alum a door material type alum 1 alum alum alum alum alum alum fire rating size hard set head jamb threshold mullion remarks detail reference door schedule
3'-0" X 7'-0" 5/a301 4/a301 6/a301
106B alum a alum 1
3'-0" X 7'-0"
3'-0" X 7'-0"
3'-0" X 7'-0"
3'-0" X 7'-0"
3'-0" X 7'-0"
3'-0" X 7'-0"
3'-0" X 7'-0"
5/a301 4/a301 6/a301
5/a301 4/a301 6/a301
5/a301 4/a301 6/a301
5/a301 4/a301 6/a301
5/a301 4/a301 6/a301
5/a301 4/a301 6/a301
5/a301 4/a301 6/a301 hw-1 hw-2 hw-3 hw-1 hw-4 hw-4 hw-4 hw-4 alum a alum 1 3'-0" X 7'-0"111 5/a301 4/a301 6/a301hw-4 note: refer to project specifications for more information.
window number a frame material type b alum a alum a window type glazing fixed/awn ins./saf.
size head jamb sill mullion remarks detail reference window schedule
1'-4" X 1'-4" m.o.
4'-0" X 2'-8" m.o.
1/a301 3/a301 2/a301fixed ins./saf. 1/a301 3/a301 2/a301 size per field measure size per field measure window TYPES FRAME / DOOR TYPES type 'a' fixed, glazing frosted
A B type "1"
NOTE:
window manufacture to provide final window sizes per field measurements of masonry openings. size to allow for shims, flashing to allow window to be plumb and square in opening.
awning, glazing frosted with screen fixed, glazing frosted
ALUM. HOLLOW METAL
DOOR FRAME.
FLUSH INSULATED ALUMINUM
DOOR. SEE PROJECT
SPECIFICATIONS FOR MORE
INFORMATION.
ROOM
NUMBER NAME
104 MEN'S TOILET
FLOOR
ff-1T&G
BLOCK NORTH EAST SOUTH
remarks
WALLS
ROOM FINISH schedule
WOMEN'S TOILET
PORCH A
PORCH B
PORCH C
ADA UNI-SEX SHOWER
ADA UNI-SEX SHOWER
UNI-SEX SHOWER
UNI-SEX SHOWER
CEILING
TYPE
T&G
T&G
T&G
T&G
T&G
BASE
WEST
PT-2
PT-2
PT-3
PT-3
PT-3
PT-3
SIGN
TYPE
B
A
D
D
E
E
FAMILY/ADA LAVATORY111 CT&G
T&G
T&G
T&G
SEALED
SEALED
SEALED
106 UTILITIES AND STORAGE ROOM EXP-1 PT-2 F
CEILING
color
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
PT-1
material manufacture notes exterior finish schedule color / finish cedar siding cedar - same mill TBD - smooth trim boards cedar - same mill gutters / downspouts galvanized steel break metal to match adjacent mat.
ff-1
SEALED
ff-1 ff-1 ff-1 ff-1 ff-1 PT-2 metal roofing pac clad snap-on standing seam hartford green - pc match existing color
NOTE:
PROVIDE multiple FULL SIZE SAMPLES of material for approval which include stone and wavy siding.
if required by state provide mock ups for owner approval. (VERIFY WITH project representative.)
T&G cedar boards - soffit Michigan White Cedar TBD - smooth
PT-1 PT-1 PT-1 PT-1 2
1. all interior wood to be SEALED OR stained
2. painted exposed wood, plywood painted with pt-2.
TBD - smooth color selection by owner
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
ST-1
1'-
1'-
PORCH A
PORCH B
PORCH C
MEN'S
FAMILY/ADA
LAVATORY
ADA UNI-SEX
SHOWER
UNI-SEX
SHOWER
UNI-SEX
SHOWER
ADA UNI-SEX
SHOWER
UTILITIES AND
STORAGE ROOM
A501
'E' 'D''D' 'E'
'C'
'F'
'F' 'B''A' polished sealed sealed polished sealed polished sealed polished sealed polished sealed polished sealed
SIM. SIM.
polished sealed polish floor test area
106B
110 109 108 107
106A 104105
A501
A501
A501
A501
A501
A501 coat hook centered at door (typ.)
WOMEN'S
CODE TO FINISH schedule
CEILING FINISHES
T&G 1x TONGUE AND GROOVE mi white cedar, STAINED WITH ST-1
EXP-1 EXPOSED STRUCTURE - PAINT P-1
PAINT FINISH
PT-1
pt-2 COLOR: WHITE
(2) coats of each epoxy PAINT and epoxy block filler
PT-3 Primer: SW Kem Cati Coat HS Epoxy Filler/Sealer, B42 Series Topcoat: SW Macropoxy 646 FC B58 Series match (pt-1) - No substitutes.
STAIN FINISH
ST-1 COLOR - clear 500/400
ST-2 COLOR - TBD.
SOLID SURFACES
SS-1 WILSONART SOLID SURFACE, COLOR: TBD
with integral sink
TEXTURE: MATTE
TOILET PARTITIONS
TP-1 PHENOLIC
COLOR - TBD
FLOORING
ff-1 polished CONCRETE, Class C level 3 finish - REFER TO SPECIFICATION.
REMARKS TO FINISH schedule
1. ALL finishes/colors to match phase 4 toilet building.
2. all doors and windows to be dark bronze finish
GENERAL NOTES TO FINISH schedule
1. SEE finish plan FOR LOCATION OF ROOM names and NUMBERS.
2. SEE finish plan FOR LOCATION OF SIGNAGE.
WOMEN
SHOWER
SHOWER
UNISEX
MEN
UTILITY
sex indicator w/ b.f. symbol
1/2" radius
6" X 8" sign
3/4" room name braille sex indicator w/ b.f. symbol
1/2" radius
6" X 8" sign
3/4" room name braille sex indicator w/ b.f. symbol
1/2" radius
6" X 8" sign
3/4" room name braille sex indicator
1/2" radius
6" X 8" sign
3/4" room name braille sex indicator w/ b.f. symbol
1/2" radius
6" X 8" sign
3/4" room name braille
1/2" radius
6" X 4" sign
3/4" room name braille sign type 'a' n.t.s.
sign type 'b' n.t.s.
sign type 'c' n.t.s.
sign type 'd' n.t.s.
sign type 'e' n.t.s.
sign type 'f' n.t.s.
NAME
soap dispenser g.c. owner remarks supplied by accessories schedule toilet paper dispenser walls hooks mirrors hand dryer sharp objects container sanitary napkin holder hose reel…