Stillwater Dam Electrical Rehab Maps.pdf
PDF 21 MB Posted
- Solicitation number
- W912DR24B0034
About this file
This document is a Pre-Solicitation Notice for a Competitive Invitation for Bid (IFB) to award construction services for the Electrical Rehabilitation of the Control Tower at Stillwater Dam in Pennsylvania. The U.S. Army Corps of Engineers, Baltimore District, intends to issue the IFB, with an estimated magnitude of construction between $500,000 and $1,000,000. The project consists of addressing electrical code violations, replacing damaged conduit, making changes to accommodate demolition of the current office building, and replacing the existing emergency generator with a new outside generator. The IFB will be available on or about July 8, 2024, with a pre-bid tour scheduled for July 18, 2024, and bids due on or about August 8, 2024. The acquisition is set aside for the Historically Underutilized Business Zone (HUBZone) Program. Responsible bidders are encouraged to participate.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Existing Conditions Demolition.pdf | ||
| Construction Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ELECTRICAL AS-BUILT DRAWINGSRE10527
ELECTRICAL AS-BUILT DRAWINGSRE10426
ELECTRICAL AS-BUILT DRAWINGSRE10325
ELECTRICAL AS-BUILT DRAWINGSRE10224
ELECTRICAL AS-BUILT DRAWINGSRE10123
EXISTING CONDITIONSE-80122
ELECTRICAL SCHEDULESE-70121
ELECTRICAL ONE-LINE DIAGRAMSE-60120
ELECTRICAL DETAILSE-50219
ELECTRICAL DETAILSE-50118
ELECTRICAL SITE PLAN - SECTION VIEWSE-30117
ELECTRICAL SITE PLAN - ENLARGED VIEWSE-10416
ELECTRICAL SITE PLAN - ENLARGED VIEWSE-10315
ELECTRICAL SITE PLAN - MAINTENANCE AREAE-10214
ELECTRICAL SITE PLANE-10113
ELECTRICAL ABBREVIATIONS, LEGEND, & SPECIFICATIONSE-00112
ELECTRICAL
MISCELLANEOUS METAL DETAILS - NO.2SR10511
GATE STRUCTURE ROOF DETAILSSR10410
GATE STRUCTURE PLANS AND SECTIONS NO.3SR1039
GATE STRUCTURE PLANS AND SECTIONS NO.2SR1028
GATE STRUCTURE PLANS AND SECTIONS NO.1SR1017
GATE STRUCTURE ELEVATIONSSR1006
ORIGINAL LADDER SECTIONSS-1025
ORIGINAL LADDER PLAN VIEWS-1014
STRUCTURAL
CWL & GENERAL NOTESG-0033
PROJECT LOCATIONG-0022
COVER SHEET & INDEXG-0011
DESCRIPTIONSHEETINDEX
GENERAL
DRAWING INDEX
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
H U
N T
IN
G
T O
N D
IS
T
R
IC
T
E
IG
H
T H
S T
R E
E T
H U
N T
IN
G
T O
N
W V
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
G-001
T
IL
L
W A
T E
R L
A K
E
F O
R E
S T
C
IT
Y P
A
S T
IL
L
W A
T E
R D
A M
E L
E C
T R
IC
A
L R
E H
A B
IL
IT
A T
IO
N
P
B E
L C
H E
R
P
B E
L C
H E
R
J
D A
H L
E R
M
K
IS
L
IN
G
A N
S I
D
F E
B R
U A
R Y
B A
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
D
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
G -0
.d g n
D S
P
D
:3
:2
P
M
/2 /2
C O
V E
R S
H E
E T
I
N D
E X
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
BALTIMORE DISTRICT
STILLWATER LAKE
FOREST CITY, PA
STILLWATER DAM
ELECTRICAL REHABILITATION
FEBRUARY 2024
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S of Engineers
US Army Corps
EMPLOYMENT AS REQUIRED BY ER 1110-1-8152.
PROJECT DOCUMENTS WITHIN THE SCOPE OF THEIR
DESIGNATIONS OF INDIVIDUALS APPEAR ON THESE
INITIALS OR SIGNATURES AND REGISTRATION
DISTRICT OF THE U. S. ARMY CORPS OF ENGINEERS. THE
THIS PROJECT WAS DESIGNED BY THE HUNTINGTON
CHIEF, ENGINEERING & CONSTRUCTION DIVISION
DENNIS E. HUGHES, P.E.
CHIEF, ELECTRICAL MECHANICAL SECTION
MATTHEW B. KISLING, P.E.
PROJECT LOCATION
PROJECT LOCATION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
H U
N T
IN
G
T O
N D
IS
T
R
IC
T
E
IG
H
T H
S T
R E
E T
H U
N T
IN
G
T O
N
W V
B M
IT
T
A L
B
C O
E S
R E
V
G-002
T
IL
L
W A
T E
R L
A K
E
F O
R E
S T
C
IT
Y P
A
S T
IL
L
W A
T E
R D
A M
E L
E C
T R
IC
A
L R
E H
A B
IL
IT
A T
IO
N
P
B E
L C
H E
R
P
B E
L C
H E
R
J
D A
H L
E R
M
K
IS
L
IN
G
A N
S I
D
F E
B R
U A
R Y
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
D
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
G -0
.d g n
D S
P
D
:3
:3
P
M
/2 /2
P R
O J E
C T
L O
C A
T
IO
N
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
PROJECT LOCATION - REGION MAP
SCALE: NTS
PROJECT LOCATION - AREA MAP
SCALE: NTS
N
GRID SPACE DETAIL IS LOCATED
SHEET ID, DETAIL IS ON
DETAIL CALL OUT
GRID SPACE SECTION IS LOCATED
SHEET ID, SECTION IS ON
SECTION CALL OUT DIRECTION OF SECTION CUT
SHEET ID, ELEVATION IS ON
GRID SPACE ELEVATION IS LOCATED
DIRECTION OF ELEVATION
TRUE NORTH
GRAPHIC SCALETEXT SCALE
TO LOWER LEFT CORNER
AREA TITLE STARTS IN REFERENCE
LOCATION ON THE GRID THE DETAIL
INDICATOR IS FOUND ON THE SHEET
WHERE THE SECTION/DETAIL
THIS POINTS TO THE GRID LOCATION
INDICATOR IS FOUND
SHEET WHERE THE
THIS POINTS TO THE FIRST
NOTES SPECIFIC TO THIS DRAWING AREA TITLE
DRAWING AREA TITLE:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
G-003
C
L
G E
N E
R A
L N
O T
E S
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
CWL
CWLCWL
CWL
C W
L
STILLWATER DAM
STILLWATER LAKE
USED TO COMPARE TO CONDUIT VOLUME.
PREVENTION OF AIR ENTRAPMENT, AND TRACKING OF GROUT QUANTITY
TOPICS INCLUDING BUT NOT LIMITED TO: METHOD OF GROUT PLACEMENT,
ENGINEER. A GROUTING PLAN MUST ALSO BE SUBMITTED TO ADDRESS
SUBMITTED FOR APPROVAL BY THE GOVERNMENT'S GEOTECHNICAL
NON-SHRINK, FLOWABLE GROUT MUST BE USED AND THE MIX DESIGN
PERFORMED TO ENSURE COMPLETE FILLING OF THE EXISTING CONDUIT. A
GROUTING OF PIPING DISCUSSED IN THESE DOCUMENTS MUST BE 17.
UTILITIES BEFORE PERFORMING SITE WORK.
PROJECTS. LOCATIONS SHOWN ARE NOT EXACT. VERIFY ALL UNDERGROUND
REFERENCE FROM THE ORIGINAL 1958 CONTRACT DRAWINGS AND PAST
EXISTING UNDERGROUND CONDUIT, HANDHOLES, AND WIRING SHOWN FOR 16.
OUT, SHOWN FOR INFORMATION ONLY.
ALL WORK NEW UNLESS OTHERWISE NOTED. EXISTING EQUIPMENT GRAYED 15.
START OF ANY CONSTRUCTION.
THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS PRIOR TO THE 14.
LIMITED WORK LIMIT AREAS SHALL NOT BE USED FOR STAGING AREAS.
CONTRACT. LWL SHALL BE LIMITED TO ACCESS TO AND FROM THE SITE.
(LWL). THE CWL WILL BE AVAILABLE UPON THE NOTICE TO PROCEED OF THE
THE SITE IS BROKEN INTO CONTRACTOR (CWL) AND LIMITED WORK LIMITS 13.
REPORTED IMMEDIATELY TO THE CONTRACTING OFFICER.
CONTRACT DOCUMENTS AND THE ACTUAL FIELD CONDITIONS MUST BE
BEFORE PROCEEDING WITH THE WORK. ANY DISCREPANCIES BETWEEN THE
FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS 12.
AND ALONG ALL AREAS TO BE REMOVED.
PAVEMENT EDGES SHALL BE SAW CUT FULL DEPTH IN AREAS OF DAMAGE
DAMAGED DURING CONSTRUCTION NOT SLATED FOR DEMOLITION. ALL
THE CONTRACTOR SHALL REPLACE IN LIKE KIND ANY EXISTING PROPERTY 11.
ROAD, OR PUBLIC AREA.
CONTRACTOR SHALL NOT BLOCK OR ADVERSELY AFFECT ANY STREET,
SHALL BE COORDINATED WITH THE CONTRACTING OFFICER. THE
THE USE OF THE SITE FOR CONSTRUCTION STAGING OR OTHER OPERATIONS 10.
REQUIREMENTS OF ALL APPLICABLE AGENCIES.
OF INGRESS AND EGRESS FROM THE WORK AREA IN ACCORDANCE WITH THE
THE CONTRACTOR SHALL MAINTAIN A FREE, SAFE, AND APPROVED MEANS 9.
COMPLIANCE WITH FEDERAL, STATE AND LOCAL LAWS.
CATCH BASINS, AND OTHER STORM WATER INLET STRUCTURES IN
MAINTAINED AT AREAS OF STOCKPILED MATERIALS, EXCAVATED AREAS,
DIRECT. SILT FENCES AND OTHER NECESSARY FILTERING DEVICES SHALL BE
DONE AS SOON AS PRACTICAL AND AS THE CONTRACTING OFFICER MAY
THE CLEANUP AND DISPOSAL OF EXCESS EXCAVATED MATERIALS SHALL BE 8.
OF THE CONTRACTING OFFICER.
DITCHES, AND PROPERTY TO ITS ORIGINAL CONDITION TO THE SATISFACTION
FROM HIS OPERATION AND RESTORE ALL SURFACES, STRUCTURES,
THE CONTRACTOR SHALL CLEAN UP ALL DEBRIS AND MATERIALS RESULTING 7.
SHALL BE INTERRUPTED OVERNIGHT.
THAT INCONVENIENCE TO CUSTOMERS IS MINIMIZED. NO UTILITY SERVICE
IMMEDIATELY REPAIRED TO THE SATISFACTION OF THE UTILITY OWNER SUCH
UTILITY SERVICES BROKEN OR DAMAGED BY THE CONTRACTOR SHALL BE 6.
ADEQUATELY BRACED AND SUPPORTED TO PREVENT DAMAGE.
OR CONDUITS CROSSING THE TRENCH, OR OTHERWISE EXPOSED SHALL BE
IF REQUIRED, TO ELIMINATE CONFLICT OR INTERFERENCE. EXISTING PIPES
CONSTRUCTION OPERATIONS TO PERMIT ADJUSTMENTS IN LINE OR GRADE,
FEATURE. THIS WORK IS TO BE DONE SUFFICIENTLY IN ADVANCE OF THE
LOCATE AND EXPOSE THEM PRIOR TO CONSTRUCTION OF THE PROPOSED
NEAR THE LINE OF THE PROPOSED IMPROVEMENT, THE CONTRACTOR SHALL
WHERE EXISTING UTILITIES AND/OR STRUCTURES ARE INDICATED AS BEING 5.
SYSTEM PRIOR TO ANY EARTHWORK.
EFFECT ON THE PROPOSED CONSTRUCTION. CONTACT PA 811 ONE CALL
PRIOR TO CONSTRUCTION TO VERIFY THE VERTICAL AND HORIZONTAL
NOT. THE CONTRACTOR SHALL EXPOSE ALL UTILITIES OR STRUCTURES
UTILITIES AND APPURTENANCES WHETHER SHOWN ON THESE PLANS OR
LOCATION, SUPPORT, PROTECTION, AND RESTORATION OF ALL EXISTING
ON THE PLANS. THE CONTRACTOR IS RESPONSIBLE FOR THE INVESTIGATION
THE ACCURACY OR THE DEPTHS OF THE UNDERGROUND FACILITY SHOWN
BUILT DRAWINGS. THE GOVERNMENT ASSUMES NO RESPONSIBILITY AS TO
SHOWN ON THE PLANS AS ACCURATELY AS POSSIBLE FROM EXISTING AS-
FACILITIES KNOWN TO BE LOCATED IN THE CONSTRUCTION AREA HAVE BEEN
THE IDENTITY AND LOCATION OF THE EXISTING UNDERGROUND UTILITY 4.
CONSTRUCTION OF IDENTIFIED ITEMS.
CONTRACTOR AND THE COST OF SAME SHALL BE INCIDENTAL TO THE
ITEM OF CONSTRUCTION IS IDENTIFIED SHALL BE PERFORMED BY THE
ALL ITEMS OF WORK CALLED FOR ON THE PLANS FOR WHICH NO SPECIFIC 3.
MANUAL, EM 385-1-1.
THE US ARMY CORPS OF ENGINEERS SAFETY AND HEALTH REQUIREMENTS
PROJECT. THE CONTRACTOR SHALL COMPLY WITH THE LATEST EDITION OF
REQUIRED OF THE CONTRACTOR AND ALL SUBCONTRACTORS ON THE
COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 IS 2.
THE CONTRACTING OFFICER.
SHOWN ON THESE DRAWINGS MUST HAVE PRIOR WRITTEN APPROVAL OF
ANY MODIFICATION TO THE SPECIFICATION OR CHANGES TO THE WORK AS 1.
GENERAL NOTES
X-###
X#
NOTE:
0 1' 2'6"
N
DRAWING AREA TITLE
SCALE: 1"=1'
X#
E1
SCALE: 1"=100'
SITE CONSTRUCTION WORK LIMITS
100' 200'0
N
LIMITED WORK LIMITS (LWL)
CONTRACTOR WORK LIMITS (CWL)
SHEET LEGEND
H U
N T
IN
G
T O
N D
IS
T
R
IC
T
E
IG
H
T H
S T
R E
E T
H U
N T
IN
G
T O
N
W V
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
S T
IL
L
W A
T E
R L
A K
E
F O
R E
S T
C
IT
Y P
A
S T
IL
L
W A
T E
R D
A M
E L
E C
T R
IC
A
L R
E H
A B
IL
IT
A T
IO
N
P
B E
L C
H E
R
P
B E
L C
H E
R
J
D A
H L
E R
M
K
IS
L
IN
G
A N
S I
D
F E
B R
U A
R Y
B A
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
D
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
X-###
X#
X-###
X#
X-###
X#
X-###
X#
B M
IT
T
A L
B
®of Engineers
US Army Corps
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
IS
S
U E
D A
T E
F E
B R
U A
R Y
B M
IT
T
A L
B
®of Engineers
US Army Corps
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
IS
S
U E
D A
T E
F E
B R
U A
R Y
B M
IT
T
A L
B
®of Engineers
US Army Corps
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
IS
S
U E
D A
T E
F E
B R
U A
R Y
B M
IT
T
A L
B
®of Engineers
US Army Corps
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
IS
S
U E
D A
T E
F E
B R
U A
R Y
B M
IT
T
A L
B
®of Engineers
US Army Corps
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
IS
S
U E
D A
T E
F E
B R
U A
R Y
B M
IT
T
A L
B
®of Engineers
US Army Corps
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
IS
S
U E
D A
T E
F E
B R
U A
R Y
B M
IT
T
A L
B
®of Engineers
US Army Corps
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
IS
S
U E
D A
T E
F E
B R
U A
R Y
B M
IT
T
A L
B
®of Engineers
US Army Corps
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
IS
S
U E
D A
T E
F E
B R
U A
R Y
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
S
P E
C
IF
IC
A
T
IO
E-001
L
E C
T R
IC
A
L A
B B
R E
V
IA
T
IO
N S
L
E G
E N
D
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
GROUND FAULT PROTECTIONGFP
GROUND FAULT CIRCUIT INTERRUPTERGFCI
GROUND FAULT INTERRUPTERGFI
GROUND FAULTGF
GENERAL, GENERATORGEN
GENERAL CONTRACTORGC
GROUNDG
FUSEFU
FEETFT
FLOAT SWITCHFS
FIRE RESISTANT, FIRE RATINGFR
FIRE PROOFFP
FLUORESCENTFLUOR
FLOORFLR
FULL LOAD AMPSFLA
FIXTUREFIXT
FIGUREFIG
FIBER OPTIC CABLEF/O
FEEDERFDR
FUSED DISCONNECTFD
FIRE ALARM CONTROL PANELFACP
FIRE ALARMFA
FAHRENHEIT, FUSEDF
EXTERIOREXT
EXTERIOR RECEPTACLEEXRC
EXTERIOR LIGHTEXLT
EXHAUSTEXH
ELECTRIC WATER HEATEREWH
ELAPSED TIME METERETM
EMERGENCY STOPESTOP
ESTIMATE(D)EST
EQUIPMENTEQUIP
EQUALEQ
EXPLOSION PROOFEP
ELECTRICAL PANELBOARDEP
ENTRANCE, ENTERINGENTR
ENGINEERENGR
ENGINE, ENGINEEREDENG
ENCLOSE(URE)ENCL
EMERGENCY LIGHTEMLT
EMERGENCYEMER
ELEVATOR, ELEVATIONELEV
ELECTRICIAN, ELECTRICAL, ELECTRONICELECT
ELECTRICELEC
EXHAUST FANEF
ELECTRICAL CONTRACTOREC
EACHEA
EAST, EMERGENCYE
DRAWINGDWG
DUST TIGHTDT
DISCONNECT SWITCHDS
DOUBLE POLE, SINGLE THROWDPST
DOUBLE POLE, DOUBLE THROWDPDT
DUST PROOFDP
DOWNDN
DAMPERDMPR
DISTRIBUTION PANELDISTR PNL
DISTRIBUTIONDIST
DISCONNECT SWITCHDISC
DIMENSIONDIM
DIAMETERDIA
DETAILDET
DEPARTMENTDEPT
DEMOLITIONDEMO
DEGREEDEG
DIRECT CURRENTDC
DOUBLEDBL
DECIBELDB
CONTROL VOLTAGE TRANSFORMERCVT
CONDENSING UNITCU
ZERO SEQUENCE CURENT TRANSFORMERCTG
CURRENT TRANSFORMERCT
CONTROL RELAYCR
CONTROL POWER TRANSFORMERCPT
CONTROL PANELCP
CONTRACTING OFFICER'S REPRESENTATIVECOR
COMPARTMENTCOMPT
COMPRESSORCOMPR
COMMONCOM
CARBON DIOXIDECO2
CONDUITCND
CURRENT LIMITING FUSECLF
CIRCUIT BREAKERCKT BKR
CIRCUITCKT
CIRCUITCIR
CHECKCHK
CLOSED CIRCUIT TELEVISIONCCTV
CABLE REELCBLR
CIRCUIT BREAKERCB
CAPACITYCAP
CABINETCAB
CONDUITC
BREAKERBKR
BRANCHBR
BUILDINGBLDG
BELOW FINISHED GRADEBFG
BATTERYBATT
AMERICAN WIRE GAUGEAWG
AVERAGEAVG
AUXILIARYAUX
AUTOMATIC TRANSFER SWITCHATS
AMPERE TRIPAT
ABOVE SUSPENDED CEILINGASC
APPROXIMATEAPPROX
AMERICAN NATIONAL STANDARDS INSTITUTEANSI
ANODIZEANOD
AMPEREAMP
ALUMINUMALUM
ALTERNATEALT
AREA LIGHTING CONTROLLERALC
AMPERE INTERRUPTING CAPACITYAIC
AIR HANDLING UNITAHU
AIR HANDLERAH
ABOVE FINISHED GRADEAFG
ABOVE FINISHED FLOORAFF
ADJACENT, ADJOINING, ADJUSTABLEADJ
ALTERNATING CURRENTAC
AIR CONDITIONINGA/C
AMP, AMPERE, AMPERAGEA
EXPLOSION PROOF XP
TRANSFERXFER
TRANSFORMERXFMR
WATER TIGHT, WEIGHTWT
WEATHERPROOFWP
WITHOUTW/O
WATT-HOUR METERWHM
WATER HEATERWH
WEATHERPROOF & GFCIWG
WITHW/
WEST, WATTSW
VENT THRU ROOFVTR
VOLTAGE TRANSFORMERV.T.
VANDLE PROOFVP
VARIABLE FREQUENCY DRIVEVFD
VERTICALVERT
VENTILATOR(TION)VENT
VOLT AMPERES REACTIVEVAR
VOLT AMPERESVA
VOLT, VOLTAGEV
UNDERVOLTAGE RELAY (RELEASE)UVR
UNDERVOLTAGEUV
UTILITYUTIL
UNINTERRUPTABLE POWER SUPPLYUPS
UNFINISHEDUNFIN
UNDERWRITERS LABORATORIESUL
UNIT HEATERUH
UNDERGROUND FEEDERUF
UNDERGROUNDUGND
TRANSMITTERTX
TYPICALTYP
SURGE SUPRESSOR
TRANSIENT VOLTAGE TVSS
TELEVISIONTV
THERMOSTATTSTAT
TOGGLE SWITCHTS
TAMPER RESISTANTTR
THERMAL MAGTM
THERMOSTATTH
TRANSFORMERTFMR
TERMINALTERM
TEMPORARYTEMP
TEMPERATURETEMP
TELEPHONETELE
TIME DELAYTD
TERMINAL BLOCKTB
TRANSFORMERT
SYSTEMSYS
SWITCHBOARDSWBD
SWITCHSW
SUSPENDEDSUSP
SUBCONTRACTORSSUBS
STRUCTURALSTRUCT
SHIELDED TWISTED PAIRSTP
STANDARDSTD
STATIONSTA
SHUNT TRIPST
SELECTOR SWITCHSSW
SOLID STATE PROTECTION RELAYSSPR
SUPPLY-SIDE BONDING JUMPERSSBJ
SOFT STARTER, SAFETY SWITCHSS
SINGLE POLE, SINGLE THROWSPST
SPEAKERSPKR
SPECIFICATIONSPEC
SINGLE POLE, DOUBLE THROWSPDT
SURGE PROTECTIVE DEVICESPD
SINGLE POLESP
SHEETSHT
SHIELDSHD
SEQUENCESEQ
SECTIONSECT
SECONDARYSEC
SERVICE ENTRANCESE
SHORT CIRCUIT RATINGSCR
SCHEDULESCHED
SHORT CIRCUIT CURRENT RATINGSCCR
SURGE ARRESTERSA
SOUTH, SWITCHS
RECEIVERRX
RAIN TIGHTRT
REDUCED VOLTAGE SOFT STARTERRVSS
REST ROOMRR
RAIN PROOFRP
RIGID METAL CONDUITRMC
RIGHT HANDRH
RETURNRET
REQUIREDREQD
REFERENCEREF
RECTIFIERRECT
RECEPTACLERECPT
RECEIVERRCVR
REMOTE CONTROLRC
RESISTANCE, RECEPTACLER
QUANTITYQTY
QUARTERQTR
QUARTQT.
POWERPWR
POLYVINYL CHLORIDEPVC
POTENTIAL TRANSFORMERPT
PROJECTPROJ
PREFABRICATE(D)PREFAB
PRIMARYPRI
POWER QUALITY METERPQM
POTENTIOMETERPOT
PANELBOARDPNL
PROGRAMMABLE LOGIC CONTROLLERPLC
PILOT LIGHTPL
PACKAGEPKG
PHASEPH
POWER FACTORPF
PEDESTALPED
PROFESSIONAL ENGINEERPE
PROTECTIVE DEVICEPD
POWER CONNECTOR, PHOTO CELLPC
PUSH BUTTON STATIONPBS
PUSH BUTTON, PULL BOXPB
PUBLIC ADDRESSPA
POLEP
OPERATIONSOPS
OVERLOADOL
RESISTANCEOHMS
OVERHEADOH
OUTSIDE DIAMETEROD
OVERCURRENT RELAYOCR
OVERCURRENT PROTECTIVE DEVICEOCPD
OVERCURRENT, ON CENTEROC
NOT TO SCALENTS
NOT REQUIREDN’’REQD
NOT REQUIREDNR
NOMINALNOM
NORMALLY OPEN, NUMBERNO
NOT IN CONTRACTNIC
NEUTRALNEUT
NATIONAL ELECTRICAL MFR ASSOC.NEMA
NATIONAL ELECTRICAL CODENEC
NORMALLY CLOSEDNC
NATURALNAT
NON-AUTOMATICNA
NOT AVAILABLE, NOT APPLICABLEN/A
NORTHN
MEGAWATTMW
MEGAVOLT AMPERESMVA
MEGAVOLT, MEDIUM VOLTAGEMV
MULTIPLYMULT
MANUAL TRANSFER SWITCHMTS
MOUNTEDMTD
MOTOR STARTERMS
MOTORMOT
MODIFIEDMOD.
METERMTR
MISCELLANEOUSMISC
MINIMUMMIN
MEGAHERTZMHz
MANUFACTURERMFR
MANUFACTURINGMFG
MEDIUMMED
MECHANICAL ROOMMECH RM
MECHANICALMECH
MAIN DISTRIBUTION PANELBOARDMDP
MOLDED CASE CIRCUIT BREAKERMCCB
MOTOR CONTROL CENTERMCC
MAIN CIRCUIT BREAKERMCB
MOTOR CONTROLMC
MAXIMUMMAX
MATERIAL(S)MATL
MANUALMAN
MAINTENANCEMAINT
MAGNETIC STARTERMAG STR
MAGNETICMAG
MACHINEMACH
MOTOR, CONTACTORM
LOUVERLVR
LOW VOLTAGELV
LIGHTINGLTG
LIGHTLT
LOCKED ROTOR AMPSLRA
LIGHTING PANELLP
LOCKOUTLO
LINELN
LEFT HAND(ED)LH
LONG, LENGTHLG
LIGHT EMITTING DIODELED
LOADLD
LIGHT CONTROLLC
LABELLBL
POUND, CONDUIT BODYLB
LIGHTNING ARRESTERLA
LINEL
KILOWATT-HOURkWH KILOWATTkW KILOVOLT AMPERES REACTIVEkVAR KILOVOLT AMPERESkVA KILOVOLTSkV
KNOCKOUT PANELKOP
KEY PADKP
KIRK-KEYKK
THOUSAND, KEYK
JUNCTION BOXJ-BOX
JUNCTION BOXJB
JUNCTIONJ
INTRINSICLY SAFEI.S.
INVERTINV
INTERIOR, INTERNALINT
INSULATIONINSUL
INSTALLATIONINST
INCLUDEDINCL
INCHIN
ISOLATED GROUNDIG
INSIDE DIAMETERID
INTERRUPTING CAPACITYIC
IN ACCORDANCE WITHIAW
HERTZHz
HYDRAULICHYDR
HEATING, VENTILATING, AIR CONDITIONINGHVAC
HIGH VOLTAGEHV
HEATERHTR
HEATINGHTG
HEIGHTHT
HIGH STRENGTHHS
HOURSHRS
HOURHR
HYDRAULIC POWER UNITHPU
HORSEPOWER, HIGH PRESSUREHP
HORIZONTALHORIZ
HAND-OFF-AUTOHOA
HUMAN-MACHINE INTERFACEHMI
HIGH MAST CONTROLLERHMC
HIGH INTERRUPTING CAPACITYHIC
HANDHOLEHH
HEAVY DUTY, HAND DRYERHD
GROUND, GROUNDEDGRD
GALLONS PER MINUTEGPM
GENERAL PURPOSEGP
GOVERNMENTGOVT
GROUNDGND
LSI
XP
XXXA
XP
XP
XXXA
XXX-#
REFER TO PANEL SCHEDULE
CIRCUIT TAG
REFER TO FEEDER SCHEDULE
FEEDER TAG
REFER TO CONNECTION SCHEDULE
(EQUIPMENT SPECIFIED BY OTHERS)
ELECTRICAL CONNECTION TAG
REFER TO EQUIPMENT SCHEDULE
EQUIPMENT TAG
REVISION TAG
KEYNOTE TAG
XXX-#
X###
X-#,#,#
ELECTRICAL LEGEND
LINETYPES / PHASING
BREAK LINE
TO REMAIN
EXISTING/REFERENCE ITEMS
SOLID LIGHT LINES INDICATE
(SEE TITLE OR NOTES TO DISTINGUISH)
- HIDDEN LINES
- ITEMS TO BE DEMOLISHED OR
DASHED DARK LINES INDICATE:
OR MODIFIED ITEMS
SOLID DARK LINES INDICATE NEW
COMMON ONE-LINE/SCHEMATIC SYMBOLS
SURGE PROTECTIVE DEVICE
MOTOR
BOND/CONNECTION
NEUTRAL CONNECTION/BUS
GROUND CONNECTION/BUS
TRANSFORMER
UTILITY GRID
UTILITY METER
TRANSFER SWITCH
GENERATOR
WIRE/CABLE.
DENOTED CONTINUATION OF
NORMALLY CLOSED RELAY CONTACT
NORMALLY OPEN RELAY CONTACT
NO. OF POLESXP
CURRENT RATINGXXXA
FUSE
NO. OF POLESXP
SWITCH
S-SHORT TIME, I-INST)
(L-LONG TIME,
TRIPPING CHAR.LSI
NO. OF POLESXP
CURRENT RATINGXXXA
CIRCUIT BREAKER
GROUND
M
ELECTRICAL ABBREVIATIONS
VERIFY FUNCTIONALITY OF EQUIPMENT AND DEVICES THAT REMAIN.
ENSURE THAT CONTINUITY OF THE SYSTEM OPERATION IS MAINTAINED AND
WHERE MODIFICATIONS ARE MADE TO EXISTING SYSTEMS TO BE RESTORED, 2.
THE OVERCURRENT PROTECTIVE DEVICE, AND RE-LABEL IT “SPARE”.
EXISTING CONDUCTORS AND CONDUIT TO THE SOURCE PANEL, TURN OFF
WHERE EXISTING DEVICES OR EQUIPMENT MUST BE REMOVED, REMOVE 1.
DEVICES.
REQUIREMENTS OF NFPA 70 (NEC) FOR ALL MATERIALS, EQUIPMENT, AND
WHERE UL STANDARDS ARE ESTABLISHED FOR THOSE ITEMS, AND
AS A MINIMUM, MEET REQUIREMENTS OF UNDERWRITER’S LABORATORY (UL), 7.
APPROPRIATE METHODS.
SEAL ALL PENETRATIONS THROUGH STRUCTURES AND MATERIALS USING 6.
CONDUCTORS SIZES.
CONDUCTOR SIZES. PROVIDE MEANS AND METHODS TO ACCOMMODATE
VERIFY THAT ALL DISTRIBUTION EQUIPMENT WILL ACCEPT THE NECESSARY 5.
THE CONTRACT DOCUMENTS, SUBMIT AN RFI TO THE COR FOR DIRECTION.
ANY DISCREPANCY IS FOUND BETWEEN MANUFACTURER STANDARDS AND
FOLLOW ALL MANUFACTURER’S WIRING DIAGRAMS FOR ALL EQUIPMENT. IF 4.
STANDARDS.
DEFINED BY THE NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION (NECA)
PERFORM ALL ELECTRICAL WORK IN A NEAT AND WORKMANLIKE MANNER, AS 3.
PROVIDE ALL TEMPORARY CONSTRUCTION POWER AS REQUIRED.2.
DESIGNATE CERTAIN ITEMS OR EQUIPMENT AS BEING PROVIDED BY OTHERS.
SPECIFICALLY CALLED OUT ON THE PLANS, UNLESS THE PLANS EXPLICITLY
LABOR AND MATERIALS, REGARDLESS OF WHETHER SUCH MATERIALS ARE
PROVIDE COMPLETE AND FUNCTIONAL ELECTRICAL SYSTEMS. INCLUDE ALL 1.
ELECTRICAL SPECIFICATIONS
THE COR FOR DIRECTION BEFORE PROCEEDING.
IF DISCREPANCIES ARE FOUND IN EQUIPMENT LOCATIONS, SUBMIT AN RFI TO 3.
ELECTRICAL CONNECTIONS.
COORDINATE THE EXACT LOCATIONS OF EQUIPMENT PRIOR TO ROUGH-IN OF 2.
PLACEMENT OF EQUIPMENT AND ROUTING OF CONDUIT.
REQUIREMENTS ARE CALLED OUT ON THE PLANS. COORDINATE EXACT
PLANS ARE DIAGRAMMATIC, EXCEPT WHERE SPECIFIC DIMENSIONAL 1.
COLOR PLASTIC TAPE IN OUTLET, PULL, OR JUNCTION BOXES.
FOR CONDUCTORS LARGER THAN #2 AWG, HAVE ENDS IDENTIFIED WITH 3.
ENVIRONMENT.
ENVIRONMENTS, USE ONLY LABELING PRODUCTS RATED FOR THE
IN LOCATIONS EXPOSED TO SUNLIGHT, MOISTURE, OR CORROSIVE 2.
STANDARDS.
PROVIDE ALL REQUIRED SAFETY PLACARDS CONFORMING TO NFPA 1.
GENERAL
EXISTING CONDITIONS AND DEMOLITION
EXACT LOCATIONS
EQUIPMENT IDENTIFICATION
NEC.
OF CONDUITS, AND PROVIDE INSULATING TYPE WHERE REQUIRED BY THE
DIGGING INTO WALL OF METAL ENCLOSURES. PROVIDE BUSHINGS ON ENDS
LOCKNUT AND BUSHING. PROVIDE LOCKNUTS WITH SHARP EDGES FOR
CONTACT WITH THE BOX; OTHERWISE USE AT LEAST MINIMUM SINGLE
ARE USED, AND WHERE BUSHINGS CANNOT BE BROUGHT INTO FIRM
LOCKNUTS WHERE REQUIRED BY THE NEC, WHERE INSULATED BUSHINGS
FASTEN CONDUITS TO SHEET METAL BOXES AND CABINETS WITH TWO 7.
CONDUIT.
FOR ALL UNDERGROUND RACEWAY ELBOWS, PROVIDE PVC-COATED RMC 6.
PROTECTION.
IN CORROSIVE ENVIRONMENTS, PROVIDE ALL CONDUIT WITH CORROSION 5.
PROVIDE RMC ABOVE GROUND, UNLESS OTHERWISE NOTED.4.
UNDERGROUND AREAS, UNLESS OTHERWISE NOTED.
PASSES BELOW TRAFFIC AREAS. USE SCHEDULE 40 PVC IN OTHER
REQUIREMENTS, USE SCHEDULE 80 PVC WHERE UNDERGROUND CONDUIT
WHERE NO DETAILS OR OTHER NOTES ARE PROVIDED WITH SPECIFIC 3.
OTHERWISE NOTED.
ALL CONDUIT SIZES SHOWN ON DRAWINGS ARE MINIMUMS, UNLESS 2.
OF THE ACTUAL WEIGHT OF THE STRUCTURE AND ITS CONTENTS.
STRUCTURES. DESIGN CUSTOM SUPPORT STRUCTURES TO SUPPORT 125%
APPLICATION. VERIFY THE ADEQUACY OF ALL CUSTOM SUPPORT
PROVIDE ONLY CONDUIT SUPPORT DEVICES RATED FOR THE SPECIFIC 1.
RACEWAY, CONDUIT, & SUPPORT STRUCTURES
THE NEC.
METALLIC PIPE, EXPOSED METAL STRUCTURE, REBAR, ETC AS REQUIRED BY
BOND SERVICE ENTRANCE GROUNDING ELECTRODE SYSTEMS TO AVAILABLE 4.
INSTALLED.
LISTED FOR THE SPECIFIC APPLICATION, MATERIALS, AND ENVIRONMENT
FOR ALL GROUNDING AND BONDING CONNECTIONS, USE ONLY PRODUCTS UL 3.
WITH THE EQUIPMENT.
GENERATION EQUIPMENT TO THE GROUNDING ELECTRODE(S) ASSOCIATED
BOND FENCES ENCLOSING TRANSFORMERS, GENERATORS, OR SOLAR 2.
EQUIPMENT GROUNDING MEANS UNLESS OTHERWISE NOTED.
FEEDERS AND ALL BRANCH CIRCUITS. CONDUIT IS NOT AN ACCEPTABLE
INSTALL WIRE-TYPE EQUIPMENT GROUNDING CONDUCTORS WITH ALL 1.
GROUNDING AND BONDING
ANNOTATION SYMBOLS
VOLTAGE.
- PROVIDE FUSES WITH A VOLTAGE RATING NO LESS THAN THE CIRCUIT
- PROVIDE COMPLETE SET OF FUSES FOR EACH FUSIBLE DEVICE.
- NEMA FU 1
PROVIDE FUSES MEETING THE FOLLOWING:2.
- FOR MULTIPOLE BREAKERS, PROVIDE WITH COMMON TRIP.
- SERIES-RATED AND PLUG-IN CIRCUIT BREAKERS ARE NOT ACCEPTABLE.
SHUNT TRIP DEVICES.
- WHERE INDICATED ON THE DRAWINGS, PROVIDE CIRCUIT BREAKERS WITH
CONDUCTOR PROVIDED.
- BREAKER TERMINALS MUST BE UL LISTED AS SUITABLE FOR THE TYPE OF
CURRENT, OR AS INDICATED, WHICHER IS GREATER.
- HAVING AN INTERRUPTING RATING GREATER THAN THE AVAILABLE FAULT
- UL 489
PROVIDE CIRCUIT BREAKERS MEETING THE FOLLOWING:1.
OVERCURRENT PROTECTIVE DEVICES
STRANDED, UNLESS OTHERWISE NOTED.
MUST BE SOLID. CONTROLS, ALARM, AND SIGNAL CIRCUITS MUST BE
STRANDED. POWER AND LIGHITNG CONDUCTORS #10 AWG AND SMALLER
POWER AND LIGHTING CONDUCTORS #8 AWG AND LARGER MUST BE 7.
WITH COLORED INSULATING MATERIALS.
USE CONDUCTORS UP TO AND INCLUDING #2 AWG THAT ARE MANUFACTURED 6.
OTHERWISE NOTED.
ALL CONDUCTOR SIZES SHOWN ON DRAWINGS ARE MINIMUMS, UNLESS 5.
ALL INTERIOR CONTROL PANEL WIRING MUST BE TYPE MTW.
UNLESS SPECIFIED OR INDICATED OTHERWISE OR REQUIRED BY THE NEC, 4.
INSULATION OR BETTER.
C CONDUCTORS, PROVIDE ONLY CONDUCTORS WITH 90 DEGREE C
CONFORMING TO UL 83. WHERE FIXTURES OR DEVICES REQUIRE 90 DEGREE
CONFORMING TO UL 44, EXCEPT THAT GROUNDING WIRE MAY BE TYPE TW
PROVIDE POWER AND LIGHTING WIRES RATED FOR 600 VOLTS, TYPE XHHW
UNLESS SPECIFIED OR INDICATED OTHERWISE OR REQUIRED BY THE NEC, 3.
DELIVERY TO SITE.
CABLES MANUFACTURED MORE THAN 12 MONTHS PRIOR TO DATE OF
AND CONDUCTOR SPECIFIED OR INDICATED. DO NOT USE WIRES AND
REQUIREMENTS OF THE NEC AND UL FOR THE TYPE OF INSULATION, JACKET,
PROVIDE WIRES AND CABLES IN ACCORDANCE WITH APPLICABLE 2.
LOCATION.
FLEXIBLE NONMETALLIC CABLE ("ROMEX") IS NOT ACCEPTABLE IN ANY 1.
CONDUCTORS
G
N
SPD
H U
N T
IN
G
T O
N D
IS
T
R
IC
T
E
IG
H
T H
S T
R E
E T
H U
N T
IN
G
T O
N
W V
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
S T
IL
L W
A T
E R
L A
K E
F O
R E
S T
C
IT
Y P
A
S T
IL
L W
A T
E R
D A
M
E L
E C
T R
IC
A
L R
E H
A B
IL
IT
A T
IO
N
P
B E
L C
H E
R
P
B E
L C
H E
R
J D
A H
L E
R
M K
IS
L
IN
G
A N
S I D
F E
B R
U A
R Y
B A
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
D
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
LIGHTING SYMBOLS
G
P
E
TRIPLEX TO THE LOWER GARAGE.
EXISTING DIRECT BURIED 1/0
LOWER GARAGE
EXISTING OFFICE
EXISTING INTAKE STRUCTURE
EXISTING UPPER GARAGE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E-101
E C
T R
IC
A
L S
IT
E
P L
A N
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A1
SCALE: 1"=50'
ELECTRICAL SITE PLAN
50' 100'0
N
P P
TS
CONDUIT (EXPOSED)
CONDUIT (UNDERGROUND)
UTILITY SERVICE DROP (OVERHEAD)
UTILITY PRIMARY POWER LINE
ELECTRICAL MANHOLE
UTILITY METER
FUSED DISCONNECT
MOBILE GENERATOR CONNECTION POINT
ELECTRICAL DISTIBUTION PANEL
TRANSFER SWITCH
UTILITY TRANSFORMER
GENERATOR
LEGEND
P
TS
TS
MG
MG
H U
N T
IN
G
T O
N D
IS
T
R
IC
T
E
IG
H
T H
S T
R E
E T
H U
N T
IN
G
T O
N
W V
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
S T
IL
L
W A
T E
R L
A K
E
F O
R E
S T
C
IT
Y P
A
S T
IL
L
W A
T E
R D
A M
E L
E C
T R
IC
A
L R
E H
A B
IL
IT
A T
IO
N
P
B E
L C
H E
R
P
B E
L C
H E
R
J
D A
H L
E R
M
K
IS
L
IN
G
A N
S I
D
F E
B R
U A
R Y
B A
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
D
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
E-102
A1
T
G
G
T
M
M
2"2"2"
2" 2"
PROJECT SIGN
PARKING LOT
INTAKE STRUCTURE
EXISTING MANHOLE "B"
EXISTING MANHOLE "A"
ELECTRIC GATE OPERATOR
FOR ELECTRIC GATE OPERATOR
DIRECT-BURIED BRANCH CIRCUIT
CONDUIT.
EXISTING TELECOM
CONCRETE DUCTBANK
UNDERGROUND CONCRETE DUCTBANK
UNDERGROUND
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
H U
N T
IN
G
T O
N D
IS
T
R
IC
T
E
IG
H
T H
S T
R E
E T
H U
N T
IN
G
T O
N
W V
M A
IN
T
E N
A N
C E
A R
B M
IT
T
A L
B
C O
E S
R E
V
E-102
T
IL
L
W A
T E
R L
A K
E
F O
R E
S T
C
IT
Y P
A
S T
IL
L
W A
T E
R D
A M
E L
E C
T R
IC
A
L R
E H
A B
IL
IT
A T
IO
N
P
B E
L C
H E
R
P
B E
L C
H E
R
J
D A
H L
E R
M
K
IS
L
IN
G
A N
S I
D
F E
B R
U A
R Y
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
D
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R
E C
T R
IC
A
L S
IT
E
P L
A N
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A1
SCALE: 1"=15'
ELECTRICAL SITE PLAN - MAINTENANCE AREA
N
15' 30'0
BUILDING
STORAGE
EXISTING
ROAD
SPILLWAY BRIDGE
E-101
M8
ENSURE CONDUIT PIPES ARE FULLY GROUTED AND CAPPED.
GEOTECHNICAL ENGINEER. SUBMIT GROUT TAKES TO THE GOVERNMENT TO
INSTALLATION METHODS TO BE APPROVED BY THE GOVERNMENT'S
SUBMIT A GROUT PLAN WHICH INCLUDES GROUT MIX DESIGN ALONG WITH 2.
UTILITIES BEFORE PERFORMING SITE WORK.
PROJECTS. LOCATIONS SHOWN ARE NOT EXACT. VERIFY ALL UNDERGROUND
REFERENCE FROM THE ORIGINAL 1958 CONTRACT DRAWINGS AND PAST
EXISTING UNDERGROUND CONDUIT, HANDHOLES, AND WIRING SHOWN FOR 1.
GENERAL SHEET NOTES
GEN-1
OTHERS)
(TO BE DEMOLISHED BY
EXISTING OFFICE
MET-1
SRV-1
MTS-1
PNL-A
SHEET KEYNOTES
SEE MANHOLE DETAILS ON SHEET E-502.7.
INSIDE THE MANHOLE.
WALL OF THE MANHOLE. REMOVE ANY GROUTING MATERIAL THAT LANDS
EXPANSION JOINT LOCATION). THE GROUTING MUST STOP AT THE INNER
TO JUST BEFORE THE ACCESS BRIDGE EXPANSION JOINT (SEE E-104 FOR
CONDUCTORS REMOVED, FULLY GROUT THE CONDUIT FROM THE MANHOLE
AFTER PHASE 2 ELECTRICAL WORK IS COMPLETED AND EXISTING 6.
NEW FENCE POSTS MUST BE INSTALLED AT MINIMUM 24" IN GROUND.5.
SPECIFICATIONS AND DETAILS FOR MORE DETAILED REQUIREMENTS.
PROVIDE NEW CONDUIT RUNS INTO EXISTING MANHOLES. SEE 4.
WHERE THE CONDUIT TRANSITIONS UNDERGROUND.
COATED RMC CONDUIT FOR EXPOSED PORTIONS OF THE CONDUIT AND
SECURELY MOUNT CONDUITS TO THE BRIDGE PARAPET WALL. PROVIDE PVC-3.
CHARACTERISTICS AS THE ORIGINAL POSTS.
ALL FENCE SECTIONS MUST TERMINATE AT FENCE POSTS OF EQUAL
MODIFY THE EXISTING FENCE LINE TO ACCOMODATE THE FENCE EXTENSION. 2.
FENCE MATERIAL CHARACTERISTICS.
PROVIDE ENOUGH ELECTRICAL WORKING CLEARANCE. MATCH THE EXISTING
EXTEND THE FENCE LINE TO ENCOMPASS THE NEW GENERATOR AND 1.
MGC
MTS-2
PNL-B
B
B
A
A
C C
SCALE: NTS
DUCTBANK SECTION "A-A"
M1
3"
SPARE
SCALE: NTS
DUCTBANK SECTION "B-B"
M6
E-3Ø255 3"
SPARE
SCALE: NTS
DUCTBANK SECTION "C-C"
M12
E-3Ø255 J-3Ø150 3"
SPARE
E-3Ø255
SCALE: NTS
DUCTBANK SECTION "D-D"
J1
2"
SPAREJ-3Ø150
D D
E-103
A11
E-103
A1
E-104
J1
E-301
J1 E-301
J1
4'-0"
FUEL INLET
STORAGE BUILDING.
SUB-BASE DIESEL TANK TO THE
CLEARANCE FROM THE GENERATOR &
PROVIDE AT MINIMUM 5 FOOT
GENERATOR TO THE FENCE LINE.
CLEARANCE FROM THE
PROVIDE AT MINIMUM 4 FOOT
GENERATOR CONCRETE FOUNDATION
EXISTING MANHOLE "B"
LOWER GARAGE.
TRIPLEX TO THE
DIRECT BURIED 1/0
THE OFFICE GENERATOR.
EXISTING CONDUIT RUN TO
PANEL.
TO THE EXISTING OFFICE
EXISTING CONDUIT RUN
(ROOF NOT SHOWN FOR CLARITY)
PRE-BUILT METAL SHED WITH ROOF.
UNDERGROUND CONCRETE DUCTBANK
CONCRETE DUCTBANK
UNDERGROUND
CONCRETE DUCTBANK
UNDERGROUND
A-3Ø400
C-3Ø175
G
E-3Ø255
J-3Ø150
ELECTRICAL WORKING SPACE
METAL FACEPLATE, SINGLE POLE SWITCH.
125V, 20A, 1-GANG DEVICE BOX WITH
INSTRUCTIONS. (TYP.)
STUB-UP LOCATIONS WITH MANUFACTURER'S
STUB-UP LOCATIONS. COORDINATE ACTUAL
5'-0"
S
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
H U
N T
IN
G
T O
N D
IS
T
R
IC
T
E
IG
H
T H
S T
R E
E T
H U
N T
IN
G
T O
N
W V
E N
L A
R G
E D
V
IE
B M
IT
T
A L
B
C O
E S
R E
V
E-103
T
IL
L
W A
T E
R L
A K
E
F O
R E
S T
C
IT
Y P
A
S T
IL
L
W A
T E
R D
A M
E L
E C
T R
IC
A
L R
E H
A B
IL
IT
A T
IO
N
P
B E
L C
H E
R
P
B E
L C
H E
R
J
D A
H L
E R
M
K
IS
L
IN
G
A N
S I
D
F E
B R
U A
R Y
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
D
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
E C
T R
IC
A
L S
IT
E
P L
A N
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A11
SCALE: 1/4"=1'
ELECTRICAL SITE PLAN - GENERATOR AND STORAGE BUILDING ENLARGED VIEW
N
BUILDING
STORAGE
EXISTING
E-102
D12
UTILITIES BEFORE PERFORMING SITE WORK.
PROJECTS. LOCATIONS SHOWN ARE NOT EXACT. VERIFY ALL UNDERGROUND
REFERENCE FROM THE ORIGINAL 1958 CONTRACT DRAWINGS AND PAST
EXISTING UNDERGROUND CONDUIT, HANDHOLES, AND WIRING SHOWN FOR 1.
GENERAL SHEET NOTES
GEN-1
MET-1
SRV-1
MTS-1
PNL-A
0 4' 8'2'
SHEET KEYNOTES
ABOVE FINISHED FLOOR.
SECURELY MOUNT FIXTURE TO SHED FRAME AND CROSSBARS, MINIMUM 7' 7.
SHED TO THE GROUND.
PROVIDED WITH FACTORY- APPLIED PAINT. SECURELY MOUNT ELECTRICAL
WORKING SPACE CLEARANCE. SHED EXTERIOR MUST BE GALVANIZED OR
AND HASP, WITH DIMENSIONS AS NECESSARY TO PROVIDE ELECTRICAL
PROVIDE PRE-BUILT, METAL SHED WITH ROOF, DOUBLE DOORS, PADLOCK 6.
AND CONTINUE TO MANHOLE "A".
START CONCRETE ENCASED DUCT BANK IN APPROXIMATELY THIS LOCATION 5.
NOT UNDERMINE THE BUILDING'S EXISTING FOUNDATION.
TRENCHING FOR CONDUIT RUNS PARALLEL TO THE BUILDING WALL MUST 4.
AUTOMATIC TRANSFER SWITCH CONTROL PANEL STUB-UP.
PROVIDE AN EMPTY 1" PVC CONDUIT FROM THE MTS-1 TO THE GENERATOR'S 3.
PANEL.
NOTES. RUN NEW CABLE INTO CONDUIT AND INTO THE NEW DISTRIBUTION
BUILDING AND BACKFILL AS SPECIFIED ON SHEET E-501'S GENERAL SHEET
THE EQUIPMENT STAND. DEMOLISH EXCESS CABLE BACK TO THE OFFICE
PROVIDE POWER TO THE FEEDERS FROM THE NEW DISTRIBUTION PANEL ON
FEEDER. DISCONNECT THE CONDUCTORS FROM THE OFFICE PANEL AND
REROUTE THE EXISTING DIRECT-BURIED, 1/0 TRIPLEX, LOWER GARAGE 2.
PERSONNEL.
COORDINATE LOCATION OF PANELS WITH THE COR AND THE PROJECT 1.
OTHERS)
(TO BE DEMOLISHED BY
EXISTING OFFICE
MGC
MTS-2
PNL-B
A1
SCALE: 1/4"=1'
ELECTRICAL SITE PLAN - EQUIPMENT STAND ENLARGED VIEW
N
E-102
B3
0 4' 8'2'
BOLLARDS (TYP.)
LTG-2
E-501
A9
FLOATWELL
GATE HOIST
STRUCTURE MAIN PANEL
EXISTING INTAKE
ACCESS BRIDGE
RAILING
EXISTING CONCRETE DUCTBANK
BRIDGE EXPANSION JOINT
STRUCTURE MAIN PANEL
EXISTING INTAKE
FLOATWELL
STRUCTURE MAIN PANEL
EXISTING INTAKE
EXISTING 3" PIPE SLEEVE
EXISTING COMMUNICATIONS CONDUIT
EXISTING COMMUNICATIONS CONDUIT
EXISTING MTS 1
WORKING SPACE
ELECTRICAL
ORIGINAL 1960s GENERATOR CONDUITSORIGINAL OFFICE FEEDER CONDUIT
EXISTING GATE MOTOR CONDUIT
EXISTING MTS CONDUIT8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
E N
L A
R G
E D
V
IE
E-104
E C
T R
IC
A
L S
IT
E
P L
A N
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
UNDERGROUND/CONCEALED UTILITIES BEFORE PERFORMING SITE WORK.
PROJECTS. LOCATIONS SHOWN ARE NOT EXACT. VERIFY ALL
REFERENCE FROM THE ORIGINAL 1958 CONTRACT DRAWINGS AND PAST
EXISTING UNDERGROUND CONDUIT, HANDHOLES, AND WIRING SHOWN FOR 1.
GENERAL SHEET NOTES
H U
N T
IN
G
T O
N D
IS
T
R
IC
T
E
IG
H
T H
S T
R E
E T
H U
N T
IN
G
T O
N
W V
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
S T
IL
L
W A
T E
R L
A K
E
F O
R E
S T
C
IT
Y P
A
S T
IL
L
W A
T E
R D
A M
E L
E C
T R
IC
A
L R
E H
A B
IL
IT
A T
IO
N
P
B E
L C
H E
R
P
B E
L C
H E
R
J
D A
H L
E R
M
K
IS
L
IN
G
A N
S I
D
F E
B R
U A
R Y
B A
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
D
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A1
SCALE: 3/8"=1'
UPSTREAM ELEVATION
0 2' 4'1'J1
SCALE: 1/2"=1'
INTAKE STRUCTURE PLAN AT ELEVATION 1637.00
SHEET KEYNOTES
NEW 20 AMP CIRCUIT BREAKER, 120V WIRING, & 1/2 INCH RMC CONDUIT.
HOMERUN POWER TO EXISTING INTAKE STRUCTURE MAIN PANEL. PROVIDE 17.
NOT USED.16.
NOT USED.15.
NOT USED.14.
SEAL HOLES INTO EXISTING PANEL.13.
REMOVE CONDUIT ABOVE EXPOSED COUPLING AND CAP.12.
CIRCUIT BREAKER WITH A LABEL THAT READS, "GFCI PROTECTED".
CIRCUIT BREAKER. LABEL ALL RECEPTACLES PROTECTED BY THE GFCI
REPLACE CIRCUIT BREAKERS FEEDING RECEPTACLE LOADS WITH A GFCI 11.
TO THE EXISTING PANEL.
DEMOLISH THE LARGE CONDUIT AND CONDUCTORS FROM THE EXISTING MTS 10.
NOT USED.9.
POWER TOOL CLEAN IAW SSPC-SP11 BEFORE APPLYING THE PAINT.
IAW THE SOCIETY FOR PROTECTIVE COATINGS (SSPC), SSPC-SP2, OR
ALONG ITS ENTIRE, EXPOSED SURFACE. HAND TOOL CLEAN THE CONDUIT
IAW AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM), ASTM A780
FOR EXISTING CONDUITS TO REMAIN, APPLY A PAINT CONTAINING ZINC DUST 8.
CONDUITS AND CAP CONDUIT ENDS.
EXISTING CONDUITS NO LONGER IN-USE AND CORRODED. DEMOLISH 7.
DEMOLISH EXISTING EXPOSED CONDUIT AND SUPPORTS.6.
SUPPORT CONDUIT IAW NEC AND MANUFACTURER REQUIREMENTS.
PROVIDE PVC-COATED RMC ON THE SERVICE BRIDGE AS INDICATED. 5.
SPACE AROUND THE CONDUIT.
INSTALL PVC-COATED RMC THROUGH THE OPENING AND FULLY GROUT
CORE DRILL THROUGH EXISTING CONCRETE WALL BEHIND THE MAIN PANEL. 4.
INACCEESSIBLE CONDUITS.
REMOVE ALL CONDUCTORS FROM INDICATED CONDUITS AND FULLY GROUT 3.
THE CONDUIT BETWEEN THE FLOOR AND THE MTS.
CUT EXISTING CONDUIT BELOW MTS AT THE FLOOR AND CAP. DISPOSE OF 2.
THE DEMOLITION.
DEMOLISH THE EXISTING MTS. SEE ONE-LINE DIAGRAMS FOR PHASING OF 1.
4'0 2' 8'
N
A7
SCALE: 3/8"=1'
INTAKE STRUCTURE SECTION
4'0 2' 8' A13
SCALE: 1-1/2"=1'
INTAKE STRUCTURE MAIN PANEL CONDUIT DETAIL
1' 2'0 6"
LTG-1
LTG-1
E-104
A1
E-104
A1
E-104
A7
E-104
A7
E-104
A13
E-301
A9
E-301
GRADE
PARAPET WALL
BRIDGE
MANHOLE "B"
DUCTBANK TO
CONCRETE
2" LFMC
ACCESS BRIDGE
BRIDGE EXPANSION JOINT
COUPLING
PAVED CREST
DAM FACEBRIDGE FOUNDATION
EXPANSION JOINT (TYP.)
UNDERGROUND TO MANHOLE "A"
PVC-COATED RMC
CONCRETE GRAVITY WALL
M
IN
IM
U
M
PVC-COATED RMC CONDUIT BODY
PVC-COATED RMC
PVC-COATED RMC
PVC-COATED RMC EXPANSION COUPLINGS
CONCRETE GRAVITY WALL
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
S E
C T
IO
N
V
IE
E-301
E C
T R
IC
A
L S
IT
E
P L
A N
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J1
SCALE: 1/4"=1'
SPILLWAY BRIDGE PARAPET WALL CONDUIT RUN DETAIL - SECTION VIEW
0 4' 8'2'
UTILITIES BEFORE PERFORMING SITE WORK.
PROJECTS. LOCATIONS SHOWN ARE NOT EXACT. VERIFY ALL UNDERGROUND
REFERENCE FROM THE ORIGINAL 1958 CONTRACT DRAWINGS AND PAST
EXISTING UNDERGROUND CONDUIT, HANDHOLES, AND WIRING SHOWN FOR 1.
GENERAL SHEET NOTES
H U
N T
IN
G
T O
N D
IS
T
R
IC
T
E
IG
H
T H
S T
R E
E T
H U
N T
IN
G
T O
N
W V
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
S T
IL
L
W A
T E
R L
A K
E
F O
R E
S T
C
IT
Y P
A
S T
IL
L
W A
T E
R D
A M
E L
E C
T R
IC
A
L R
E H
A B
IL
IT
A T
IO
N
P
B E
L C
H E
R
P
B E
L C
H E
R
J
D A
H L
E R
M
K
IS
L
IN
G
A N
S I
D
F E
B R
U A
R Y
B A
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
D
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
SHEET KEYNOTES
UNDERGROUND CONCRETE GRAVITY WALL.
PROVIDE CONDUIT FITTINGS AS NECESSARY TO ROUTE BY THE 8.
EXPANSION COUPLINGS MUST INCLUDE INTERNAL GROUNDING.7.
INSTALL LFMC TO ALLOW FOR EXPANSION OF THE ACCESS BRIDGE.6.
NOT USED.5.
CONDUIT BODY OPENINGS MUST BE ACCESSIBLE AFTER INSTALLATION.4.
TRANSITION FROM PVC-COATED RMC TO PVC CONDUIT.3.
SPECIFICATIONS AND DETAILS FOR MORE DETAILED REQUIREMENTS.
PROVIDE NEW CONDUIT RUNS INTO EXISTING MANHOLES. SEE 2.
REQUIREMENTS.
DUCTBANK. PROVIDE CONDUIT SUPPORTS IAW NEC AND MANUFACTURER
CONDUIT SECTIONS UNDERGROUND THAT ARE NOT IN THE CONCRETE
COATED RMC CONDUIT FOR EXPOSED PORTIONS OF THE CONDUIT AND
SECURELY MOUNT CONDUITS TO THE BRIDGE PARAPET WALL. PROVIDE PVC-1.
E-104
N11
A9
SCALE: 1"=1'
TOWER ACCESS BRIDGE NEW POWER CONDUITS
0 1' 2'6"
GRADE
#6 REBAR. LOCATE IN CENTER OF PAD THICKNESS (TYP.)
1/2" CHAMFER (TYP. ALL SIDES)
6" 6"
PROVIDE 6" CONCRETE LIP ON ALL SIDES
" 4
DIESEL TANK
GENERATOR
GROUND ROD
BOND TO GENERATOR
BOND TO PAD REBAR
CONDUIT STUB-UP AREA (TYP.)
GROUND ROD
WIRE TO REBAR
BOND GROUND
#6 REBAR, MAX. SPACED 7" ON CENTER.
#6 REBAR, MAX. SPACED 12" ON CENTER.
ELECTRIC STUB-UP AREA. (TYP.)
STUB-UP INTO THE GENERATOR
PVC CONDUITS. NUMBER AS NEEDED.
COURSE
6" AGGREGATE BASE
EXISTING BASE COURSE
DESIGNATION, 6" MIN.
PA PUBLICATION 408, 2A
NEW AGGREGATE BASE COURSE
BEYOND EXCAVATION WALL
NEW PAVEMENT, 6" MIN.
THICKNESS, 3" MIN.
MATCH EXISTING ASPHAST
1'-0" BELOW FINISHED GRADE
6" RED WARNING TAPE APPROX.
FINISHED GRADE
EXISTING SUBGRADE
EXCAVATION
ALL OTHER DUCTBANKS. (TYP.)
PROVIDE PVC-COATED RMC FOR
CONCRETE-ENCASED DUCTBANKS.
PROVIDE PVC CONDUIT FOR
BACKFILL
OTHERWISE INDICATED)
ENCASEMENT (UNLESS
RED DYED CONCRETE
3" 3" 3"
FOR CONCRETE-ENCASED SECTIONS)
#4/0 AWG GROUNDING CONDUCTOR (ONLY
M
IN
EXISTING ASPHALT
3" 3" 3" 3"
CONDUIT HUB (TYP.)
PVC CONDUIT (TYP.)
STRUT CHANNEL (TYP.)
CONDUIT STRAPS (TYP.)
M
A X
CONDUIT SLIP RISERS (TYP.)
GROUND ROD
M
IN
GRADE
#6 REBAR (TYP.)
EQUIPMENT SHED
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
H U
N T
IN
G
T O
N D
IS
T
R
IC
T
E
IG
H
T H
S T
R E
E T
H U
N T
IN
G
T O
N
W V
B M
IT
T
A L
B
C O
E S
R E
V
E-501
T
IL
L
W A
T E
R L
A K
E
F O
R E
S T
C
IT
Y P
A
S T
IL
L
W A
T E
R D
A M
E L
E C
T R
IC
A
L R
E H
A B
IL
IT
A T
IO
N
P
B E
L C
H E
R
P
B E
L C
H E
R
J
D A
H L
E R
M
K
IS
L
IN
G
A N
S I
D
F E
B R
U A
R Y
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
D
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
E C
T R
IC
A
L D
E T
A
IL
S
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
J1
SCALE: NTS
GENERATOR PAD DETAIL - SECTION VIEW
WITH THE MANUFACTURER OF THE APPROVED EQUIPMENT AND THE SPECIFIC REQUIREMENTS INDICATED.
FAIR AND OPEN COMPETITION. COORDINATE ALL REQUIRED CONCRETE PAD & ELECTRICAL STUB-UP REQUIREMENTS
NOTE: THE EQUIPMENT SHOWN IS INTENDED AS A GRAPHIC REPRESENTATION AND IS NOT INTENDED TO LIMIT
D1
SCALE: NTS
GENERATOR PAD DETAIL - PLAN VIEW
A9
SCALE: NTS
EQUIPMENT SHED DETAIL - SECTION
NOTE: COORDINATE STUB-UP LOCATIONS WITH THE GENERATOR REQUIREMENTS.
H9
SCALE: NTS
TYPICAL 2 CONDUIT DUCTBANK
PAVED NON-PAVED AREA
G15
SCALE: NTS
TYPICAL 3 CONDUIT DUCTBANK
DIMENSIONS SHOWN ARE MINIMUM ACCEPTABLE DISTANCES.
2 CONDUIT DUCTBANK DETAIL, EXCEPT WHERE INDICATED.
NOTE: DETAILS FOR THE 3 CONDUIT DUCTBANK MATCH THE
NOTE: DIMENSIONS SHOWN ARE MINIMUM ACCEPTABLE DISTANCES.
MGC MTS-2 PNL B
HOURS/DAY, 7 DAYS/WEEK.
CONTRACTOR MUST PROVIDE CONTACT INFORMATION THAT CAN BE USED 24
FLOOD FIGHTING ACCESS ACROSS THE DAM IF IT BECOMES NECESSARY.
DOES NOT POSE RISKS TO THE DAM DURING STORM EVENTS OR IMPEDE
GOVERNMENT. THIS IS NECESSARY TO ENSURE THAT OPEN EXCAVATION
ANY OPEN EXCAVATIONS WITHIN 24 HOURS OF NOTICE FROM THE
MATERIALS AND EQUIPMENT MUST BE MAINTAINED AT THE SITE TO BACKFILL 6.
EXCAVATION WORK.
GEOTECHNICAL ENGINEER WHO MAY VISIT THE SITE TO OBSERVE
EXCAVATION WORK. THE COR WILL ALSO NOTIFY THE GOVERNMENT'S
WHICH MAY REQUIRE OPERATIONS AT THE DAM THAT SHOULD POSTPONE
COR WILL CONFIRM WHETHER THERE ARE ANY IMPENDING STORM EVENTS
NOTIFY THE COR A MINIMUM OF ONE WEEK PRIOR TO ANY EXCAVATION. THE 5.
THE AREA IS AN EARTHEN DAM.
GOVERNMENT'S GEOTECHNICAL ENGINEER. THIS WORK IS CRITICAL SINCE
SIDEWALLS OF THE TRENCH MUST BE REPAIRED AS DIRECTED BY THE
SUFFICIENT CONCRETE STRENGTH GAIN. ANY INSTABILITY OF THE
EXCAVATION AND THAT THE EXCAVATION IS QUICKLY BACKFILLED AFTER
WORK SHALL BE SCHEDULED SO THAT DUCTBANK IS PLACED SOON AFTER 4.
ACCORDANCE WITH EITHER ASTM D1556 OR ASTM D6938.
DURING CONSTRUCTION AT LEAST ONCE PER LIFT OF MATERIAL IN
TYPE OF BACKFILL MATERIAL. FIELD DENSITY TESTS SHOULD BE TAKEN
MOISTURE-DENSITY TEST (ASTM D698) SHOULD BE PERFORMED FOR EACH
CONTENT WITHIN PLUS OR MINUS 2% OF OPTIMUM. A MINIMUM OF ONE
SHOULD BE PERFORMED TO 90% OF MAXIMUM DENSITY AT A MOISTURE
BACKFILL SHALL BE COMPACTED IN MAXIMUM 4" LIFTS. COMPACTION 3.
ASTM D 2487 MUST BE SUBMITTED.
ASSOCIATED LABORATORY TESTING SHOWING SOIL CLASSIFICATION PER
APPROVED BY THE GOVERNMENT'S GEOTECHNICAL ENGINEER AND
FROM EXCAVATION, THE IMPORTED MATERIAL MUST BE CLAY SOIL,
OPERATIONS. IF BACKFILL MATERIAL IS REQUIRED BEYOND THAT AVAILABLE
GOVERNMENT'S GEOTECHNICAL ENGINEER PRIOR TO EARTHWORK
BACKFILL MATERIAL. BACKFILL MATERIALS MUST BE DISCUSSED WITH THE
EXISTING AGGREGATE BASE AND PAVEMENT SHOULD NOT BE USED AS
WET, MAY REQUIRE DRYING PRIOR TO PLACEMENT AND COMPACTION.
CLAY SOILS SHALL BE USED FOR BACKFILLING AND, IF THEY ARE EXCAVATED 2.
GENERAL NOTES APPLY TO ALL EARTHWORK ON THE PROJECT.1.
GENERAL NOTES
SHEET KEYNOTES
#6 AWG, BARE COPPER WIRE.
BOND SHED METAL FRAMING TO GROUNDING ELECTRODE SYSTEM USING A 4.
SUBMIT THE MOUNTING PLAN FOR GOVERNMENT APPROVAL.
THE GROUND BELOW THE SHED. IF AN INDEPENDENT STAND IS REQUIRED,
STRUCTURE, PROVIDE AN INDEPENDENT MOUNTING STAND ANCHORED TO
TO THE SHED, OR ITS COMBINED WEIGHT IS TOO MUCH FOR THE SHED
PUSHED AT ANY ANGLE. IF EQUIPMENT CANNOT BE ADEQUATELY MOUNTED
EQUIPMENT IN THE SHED. MOUNTED EQUIPMENT MUST NOT BUDGE WHEN
PROVIDE HARDWARE, STRUT, AND FRAMING AS REQUIRED TO MOUNT 3.
MATCH CONDUIT SLIP RISER SIZE TO CORRECT PVC CONDUIT SIZE.2.
MANUFACTURER INSTRUCTIONS. (TYP.)
ANCHOR CONCRETE EMBEDMENT. NUMBER AS REQUIRED BY
CONCRETE EXPANSION ANCHORS WITH WASHERS. PROVIDE MINIMUM 4" OF
ANCHOR GENERATOR FRAME TO PAD USING 5/8" POST-INSTALLED 1.
COVER FRAME
FILTER MATERIAL
3" DIAMETER BLACK STEEL PIPE SLEEVE
FLOOR DRAIN
31"
4' - 0"
#4 DOWELS TOP & BOTTOM
PULL IRONS (TYP.)
FLOOR DRAIN
CABLE RACK (TYP.)
EXISTING DUCT ARRANGEMENT
1' - 6"
6" (TYP.)
FROM MANHOLE "A"
COMMERCIAL POWER FEED
EXISTING INCOMING
FEED TO INTAKE STRUCTURE
EXISTING COMMERCIAL POWER
FEED TO INTAKE STRUCTURE
EXISTING GENERATOR POWER
FROM INTAKE STRUCTURE
EXISTING OFFICE POWER FEED
EXISTING POWER FEED TO OFFICEEXISTING POWER FEED FROM GENERATOR
SPARE
SPARE
SPARE
SPARE
FEED TO MANHOLE "B"
COMMERCIAL POWER
SPARE
SPARE FEEDER FROM THE SERVICE DROP
EXISTING COMMERCIAL POWER
UNGROUNDED CABLES (TYP.)
HEAVY DUTY CABLE TIE WRAPS (TYP.)
CABLE RACK HOOK (TYP.)
CABLE RACK INSULATORS (TYP.)
CABLE RACKS
DOME TOP TO DRAIN
2" REFLECTIVE TAPE ALL AROUND (TYP.)
PIPE FILL WITH CONCRETE
6" SCH 40 GALVANIZED STEEL
FINISHED GRADE
1'-6"
6" (TYP.)
CONCRETE
E-3Ø255
E-3Ø255
E-3Ø255
E-3Ø255
J-3Ø150
J-3Ø150
SPARE
BUSHING (TYP.)
PVC-COATED GROUDING
BUSHING (TYP.)
PVC-COATED GROUDING
UNGROUNDED CONDUCTORS.
INSULATORS AS NEEDED TO SUPPORT ALL
PROVIDE CABLE RACK LENGTH AND
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
H U
N T
IN
G
T O
N D
IS
T
R
IC
T
E
IG
H
T H
S T
R E
E T
H U
N T
IN
G
T O
N
W V
B M
IT
T
A L
B
C O
E S
R E
V
E-502
T
IL
L
W A
T E
R L
A K
E
F O
R E
S T
C
IT
Y P
A
S T
IL
L
W A
T E
R D
A M
E L
E C
T R
IC
A
L R
E H
A B
IL
IT
A T
IO
N
P
B E
L C
H E
R
P
B E
L C
H E
R
J
D A
H L
E R
M
K
IS
L
IN
G
A N
S I
D
F E
B R
U A
R Y
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
D
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
E C
T R
IC
A
L D
E T
A
IL
S
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
REFERENCE FROM THE ORIGINAL 1958 CONTRACT DRAWINGS.
EXISTING UNDERGROUND CONDUIT AND HANDHOLES SHOWN FOR 1.
GENERAL SHEET NOTES
2'0 1' 4'J2
SCALE: 3/4"=1'
EXISTING MANHOLE "A" PLAN
SHEET KEYNOTES
CONCRETE WALL.
REMAINING SPACE BETWEEN THE NEW CONDUIT AND THE EXISTING
HEIGHT OF EXISTING CONDUITS IN THE MANHOLE. COMPLETELY GROUT THE
CORE DRILL THROUGH EXISTING CONCRETE FOR NEW CONDUIT. MATCH 8.
TIE WOUND THROUGH THE HOOK'S HOLES.
SECURELY MOUNT CABLE AND INSULATOR TO RACK HOOK USING A CABLE
INSULATORS MAY BE CLEANED AND REUSED IF IN GOOD CONDITION.
PROVIDE AND INSTALL NEW CABLE RACK INSULATORS. EXISTING 7.
AS INDICATED. DISPOSE OF EXISTING CABLE RACK HOOKS.
PROVIDE AND INSTALL NEW CABLE RACK HOOKS ON EXISTING CABLE RACKS 6.
BANKS TO EXISTING UNDERGROUND STRUCTURES.
SEE SPECIFICATIONS FOR DETAILED REQUIREMENTS TO ATTACH NEW DUCT 5.
FEEDERS ONTO NEW CABLE RACKS.
PROVIDE NEW CABLE RACKS, INSULATORS, AND CABLE TIES. ROUTE NEW 4.
HOURS.
HOURS. INFORM THE COR IF ANY WATER IS STILL STANDING AFTER 24
WITH APPROXIMATELY 1" DEEP WATER. LET THE MANHOLE DRAIN FOR 24
CAPABILITY OF THE EXISTING FILTER MATERIAL BY FILLING THE MANHOLE
FLOOR DRAINS OF ANY FOREIGN MATERIALS. TEST THE DRAINAGE
IN MANHOLE "A" AND "B", DRAIN ALL STANDING WATER. CLEAR THE EXISTING 3.
USING A #6 AWG GROUNDING CONDUCTOR.
EQUIPMENT GROUNDING CONDUCTORS TO THE 4/0 AWG GROUND LOOP
GROUNDING CONDUCTORS, CONDUIT GROUNDING BUSHINGS, AND
BOND ALL METAL CABLE RACKS, COVER FRAMES, DUCTBANK 4/0 AWG 2.
THE ENTIRE MANHOLE.
APPROXIMATELY 12" ABOVE THE BOTTOM OF THE MANHOLE. RUN AROUND
PROVIDE A BARE, COPPER 4/0 AWG GROUNDING CONDUCTOR LOOP 1.
2'0 1' 4'J7
SCALE: 3/4"=1'
TYPICAL MANHOLE SECTION
N
2'0 1' 4'C2
SCALE: 3/4"=1'
EXISTING MANHOLE "B" PLAN
N
C9
SCALE: NTS
TYPICAL CABLE RACK
A15
SCALE: NTS
TYPICAL BOLLARD DETAIL
FOOTING
ONE-LINE DIAGRAM PHASING.
NOTE: DEMOLISH EXISTING DASHED CONDUCTORS IAW
ONE-LINE DIAGRAM PHASING.
NOTE: DEMOLISH EXISTING DASHED CONDUCTORS IAW
C7
MANHOLE "B" - EXISTING CONDITIONS
SCALE: NTS
UTILITY PRIMARY SERVICE
15kV - 208Y/120V, 3Ø, 4W
UTILITY TRANSFORMER
208Y/120V, 3Ø, 4W
GENERATOR SET
60 kW OFFICE
MAIN PANEL
STRUCTURE
INTAKE
3P
70A
PANEL
OFFICE MAIN
60A, 2P
3P
400A
3P
100A
PANEL
GARAGE
UPPER
2P
100A
3P
150A
PANEL
GARAGE
LOWER
2P
100A
UTILITY PRIMARY SERVICE
15kV - 208Y/120V, 3Ø, 4W
UTILITY TRANSFORMER
MAIN PANEL
STRUCTURE
INTAKE
2P
30A
3P
400A
3P
150A
LI
3P
200A
150A, 3P
EQUIPMENT SHED
UPPER GARAGE
100A, 2P
20 HP
MOTOR
GATE
2P
30A
HEATER
UNIT
HEATER
UNIT
20 HP
MOTOR
GATE
2P
100A
PANEL
GARAGE
LOWER
INTAKE STRUCTURE
3P
70A
INTAKE STRUCTURE
G
N
G
N
G
N
G
N
G
N
G
N
PANEL
GARAGE
UPPER
2P
100A
SPD
20A, 1P
PNL B
MTS-2
MGC
GEC
H-3Ø175
I-3Ø200
J-3Ø150
LTG-2
L-1Ø20
G
C1
SCALE: NTS
PHASE 1 ONE-LINE DIAGRAM
C9
SCALE: NTS
PHASE 2 ONE-LINE DIAGRAM
GEC
2 3
A-3Ø400
B-3Ø400
E-3Ø255
GEC
GEC
C-3Ø175
D-3Ø400
F-1Ø100
G 8
H-3Ø175
I-3Ø200
J-3Ø150
L-1Ø20
L-1Ø20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E-601
E C
T R
IC
A
L O
N E
-L
IN
E D
IA
G
R A
M S
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
OPERATOR.
HOURS. ALL POWER OUTAGES MUST BE APPROVED IN ADVANCE BY THE DAM
STRUCTURE AND OFFICE MUST NOT BE WITHOUT POWER FOR MORE THAN 24
COORDINATE ELECTRICAL WORK TO MINIMIZE POWER OUTAGES. THE INTAKE 2.
THE MOBILE GENERATOR AND CONNECTING CABLES FROM THE PROJECT.
ACCEPTED BY THE COR. AFTER THE CONTRACT IS COMPLETED, REMOVE
ON SITE UNTIL ALL OTHER ELECTRICAL ITEMS ARE PROVIDED, TESTED, AND
MOTOR. PROVIDE FUEL AS NECESSARY. THE MOBILE GENERATOR MUST STAY
ELECTRICAL LOADS AND SIZED TO START THE INTAKE STRUCTURE'S GATE
GENERATOR MUST PROVIDE RELIABLE POWER TO OPERATE THE SITE'S
PROVIDE TEMPORARY GENERATOR DURING CONSTRUCTION. THE MOBILE 1.
GENERAL SHEET NOTES
M
MTS
LI
3P
200A
208Y/120V, 3Ø, 4W
GENERATOR
50 kW MOBILE
150A, 3P
M
208Y/120V, 3Ø, 4W
GENERATOR SET
50 kW NEW
208Y/120V, 3Ø, 4W
GENERATOR
50kW MOBILE
LI
3P
400A
SRV-1
G
N
MTS-2
MTS-1
GEN-1MET-1
PNL B
MGC
PNL A
LI
3P
200A
EQUIPMENT SHED
100A, 2P
G
N
G
N
G
N
G
N
G
N
G
N
SHEET KEYNOTES
CIRCUIT BREAKER WITH A LABEL THAT READS, "GFCI PROTECTED".
CIRCUIT BREAKER. LABEL ALL RECEPTACLES PROTECTED BY THE GFCI
REPLACE CIRCUIT BREAKERS FEEDING RECEPTACLE LOADS WITH A GFCI 9.
FOR CONDUCTOR AND OCPD SIZING.
COORDINATE WITH MANUFACTURER'S RECOMMENDATION & REQUIREMENTS 8.
THAN 175 AMPS.
LARGEST CIRCUIT BREAKER FOR THIS SIZE GENERATOR, BUT NO LARGER
COORDINATE WITH THE GENERATOR MANUFACTURER TO PROVIDE THE 7.
RECONNECT EXISTING UPPER GARAGE PANEL TO THE NEW PANEL A.6.
APPROXIMATELY LOCATED UNDERGROUND.
CONTINUE TO THE LOWER GARAGE AND WHERE THE CABLE IS
PANEL B. COORDINATE WITH THE COR TO IDENTIFY WHICH CONDUCTORS
DIG UP AND REDIRECT DIRECT-BURIED FEEDER CONDUCTORS TO THE NEW 5.
FEEDERS. MINIMIZE INTAKE STRUCTURE ELECTRIC POWER DOWNTIME.
COORDINATE DEMOLITION OF FEEDER CABLES AND INSTALLATION OF NEW 4.
REMOVE AND DISPOSE OF THE EXISTING GENERATOR FEEDERS. 3.
ELECTRICAL NEEDS DURING CONSTRUCTION.
GENERATOR EQUIPMENT IS OPERABLE AND CAN SUPPORT THE SITE'S
DO NOT DEMOLISH THE EXISTING UTILITY FEEDER UNTIL THE MOBILE 2.
ONE-LINE MODIFICATIONS.
UNKNOWN. COORDINATE CHANGES TO THE SERVICE TO INCORPORATE THE
UPPER GARAGE FEEDER CONNECTION TO THE EXISTING SERVICE IS 1.
2P
100A
LI
3P
SPD
SPD
PANEL
ACCESSORY
GENERATOR
H U
N T
IN
G
T O
N D
IS
T
R
IC
T
E
IG
H
T H
S T
R E
E T
H U
N T
IN
G
T O
N
W V
S U
B M
IT
T
A L
B
C O
E S
R E
V
IE
W
S T
IL
L
W A
T E
R L
A K
E
F O
R E
S T
C
IT
Y P
A
S T
IL
L
W A
T E
R D
A M
E L
E C
T R
IC
A
L R
E H
A B
IL
IT
A T
IO
N
P
B E
L C
H E
R
P
B E
L C
H E
R
J
D A
H L
E R
M
K
IS
L
IN
G
A N
S I
D
F E
B R
U A
R Y
B A
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
D
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
1P
20A
GFCI
1P
20A
LTG-1
20A, 1P
LTG-2
G
N
G
TEMPERATURE EXTREME LISTED ABOVE.
1. INCLUDE ALL HEATING ACCESSORIES NECESSARY FOR STARTING AT LOW
REMARKS:
NOREMOTE EMERGENCY STOP
NOREMOTE ANNUNCIATOR
WEATHERPROOF, NEMA 3RENCLOSURE
YESRAIN HOOD OVER ENCLOSURE INTAKE
YESMOTORIZED INTAKE AND OUTLET LOUVERS
YESCONTROLS ANTI-CONDENSATION HEATER
YESINTEGRAL RECEPTACLE AND LIGHT
YESINTEGRAL ACCESSORY LOAD PANEL
1 BREAKERMAIN LINE CIRCUIT BREAKER
ACCESSORY REQUIREMENTS:
10 SECONDSMAX TIME TO START AND BE READY TO ASSUME LOAD
TURBOCHARGEDINDUCTION METHOD
JACKET WATERINTERCOOLER TYPE
FIN-TUBE (RADIATOR)HEAT EXCHANGER TYPE
ETHYLENE GLYCOLENGINE COOLING TYPE
1800 RPMMAXIMUM ENGINE SPEED
YESINTEGRAL BATTERY CHARGER
3% (MAXIMUM)
FULL LOAD)
FREQUENCY REGULATION (DROOP) (NO LOAD TO
PLUS OR MINUS 0.4%FREQUENCY BANDWIDTH (STEADY STATE)
100% OF SERVICE LOAD AT 0.8 PFMAX STEP LOAD DECREASE (WITHOUT SHUTDOWN)
5% OF RATED FREQUENCY
INCREASE
MAXIMUM FREQUENCY DEVIATION WITH STEP LOAD
30% OF RATED VOLTAGE
INCREASE
MAXIMUM VOLTAGE DEVIATION WITH STEP LOAD
2 SECONDS
INCREASE (FREQUENCY)
TRANSIENT RECOVERY TIME WITH STEP LOAD
2 SECONDS
INCREASE (VOLTAGE)
TRANSIENT RECOVERY TIME WITH STEP LOAD
50% OF SERVICE LOAD AT 0.8 PFMAX STEP LOAD INCREASE
3 PHASEPHASES
208Y/120VVOLTAGE
60 HzFREQUENCY
PLUS OR MINUS 2%VOLTAGE BANDWIDTH (STEADY STATE)
PLUS OR MINUS 2% (MAXIMUM)VOLTAGE REGULATION (NO LOAD TO FULL LOAD)
DROOPGOVERNOR TYPE
ADDITIONAL SPECIFICATIONS:
NEC 702CODE REQUIREMENT
0° TO 90° FSITE TEMPERATURE RANGE
750 FTSITE ELEVATION
SITE AND CODE REQUIREMENTS:
24 HOURSUB-BASE TANK SIZE
DIESELFUEL TYPE
STAND-ALONEENGINE-GENERATOR APPLICATIONS
50kW @ 0.8 POWER FACTOR LAGGINGRATING
OPTIONAL STANDBYTYPE
PERFORMANCE REQUIREMENTS:
ENGINE-GENERATOR PARAMETER SCHEDULE
GEN-1
2. SEE PANEL SCHEDUES FOR DETAILED SPECIFICATIONS.
1. SEE ENGINE-GENERATOR PARAMETER SCHEDULE & SECTION 26 32 15.00 FOR DETAILED SPECIFICATIONS.
REMARKS:
FUNCTIONING ELECTRICAL SYSTEM MEETING ALL SPECIFIED REQUIREMENTS.
THIS SCHEDULE ONLY INCLUDES MAJOR ELECTRICAL ITEMS. PROVIDE HARDWARE, CONDUIT, CABLE, ACCESSORIES, AND EQUIPMENT AS NECESSARY FOR A FULLY
- 4 FOOT LONG
- ~4,000 LUMENS
- 4000K CCT
- 80 CRI
N/ADAMP LOCATION1120 V0.291LED STRIP LIGHTLTG-2
- SWITCHABLE CCT SET TO 4000K
- ADJUSTABLE LUMEN OUTPUT (ALO) SET TO 8,500 LUMENS.
- MOUNT 8 FOOT ABOVE ACCESS BRIDGE.
- INTEGRAL PHOTOCELL.
- IAW SECTION 26 56 00.
N/ANEMA 3R1120 V0.49 A1EXTERIOR WALL SCONCELTG-1
2WITH DOWNSTREAM SPD, IAW SECTION 26 05 00.00 40.SEE REMARKS1PANEL BPNL-B
2WITH SERVICE ENTRANCE SPD, IAW SECTION…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .