Sterilgard BSC Operating Manual.pdf
PDF 2 MB Posted
- Solicitation number
- 36C24925Q0381
About this file
This document is an operator's manual for the SterilGARD® e3 (SG304) Class II, Type A2 biosafety cabinet manufactured by Baker Company. The manual provides comprehensive instructions for operating, maintaining, and cleaning the biosafety cabinet, which is designed to provide personnel, product, and environmental protection during laboratory and scientific procedures.
The manual details the cabinet's technical specifications, including its HEPA filtration system that delivers unidirectional down airflow, with approximately 70% of air recirculated and 30% exhausted through a HEPA filter. Key features include a sliding viewscreen, LED and optional UV lighting, an analog pressure gauge, programmable timers, and various alarm systems to ensure safe operation. The document emphasizes strict protocols for use, including proper cleaning procedures, handling of spills, and guidelines for working within the cabinet, with multiple warnings about potential hazards and the importance of following manufacturer instructions to maintain safety and equipment integrity.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24925Q0381 0002.docx | DOCX document | |
| 36C24925Q0319 LineItems FINAL.xlsx | XLSX spreadsheet | |
| 36C24925Q0381 0001.docx | DOCX document | |
| 36C24925Q0319 LineItems REVISED.xlsx | XLSX spreadsheet | |
| Murfreesboro Sterile Compounding Area.pdf | ||
| 36C24925Q0381_1.docx | DOCX document | |
| Nashville Sterile Compounding Area.pdf | ||
| Wage Determination No 2015-4647 Revision 29.docx | DOCX document | |
| LIMITATIONS ON SUBCONTRACTING CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION.docx | DOCX document | |
| 36C24925Q0381 LineItems.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
175 Gatehouse Road / Sanford, Maine 04073 / USA
800-992-2537 / 207-324-8773 / Fax: 207-324-3869 / bakerco@bakerco.com / bakerco.com mailto:bakerco@bakerco.com
Table of Contents
Function of the SterilGARD® e3
Cabinet Design
LED Light Canopy
Regulatory Compliance
Standards
Cautionary Notes
Standard Features
Alarms
Armrest
Cable Port
Cable Port Hooks
Controls
Drain Pan
Filters
High Velocity Return Air Slots
Lighting
Motor/Blower
Motor Speed Control
Outlets
Pressure Plenum (UniPressureTM Preflow Plenum)
Pressure Monitor
ReadySAFE™ Mode
Service Connections
Timers
Towel Guards
Viewscreen
Work Surface
Working Access Opening Height
Optional Features
Anchoring Systems
Anchors
Building Management Systems
Cabinet Setpoint Monitor
Filters
ULPA Filter
Canopy Exhaust Connection (CEC)
Foot Rest
IV Bar
Service Connections
Hardware
Quantity and Exiting Direction
Material
Stand
Telescoping Stand
Caster Stand
Ultraviolet Light (UV)
Proper Cabinet Use
Controls
Operation
UV Light (Optional)
LED Light
Outlet
Blower
Alarm Mute (Alarm Reset)
Cabinet Timer Functions
Alarm Conditions
Power/Processor Fault Alarm
Viewscreen Position Alarm
Double Viewscreen Position Sensor Fault Alarm
Pressure Alarm (Cabinet Setpoint Monitor option)
Low Exhaust Airflow Alarm (Canopy Exhaust option)
Alarm Summary Table
Start-up Procedure
Working in the Cabinet
Using Ancillary Equipment
Cable Port Usage
Reacting to Spills
Cleaning and Disinfecting Stainless Steel
Simple Cleaning
Disinfection
Cleaning Spills
Space Decontamination