Statement of Work sam.docx
DOCX document 35 KB Posted
- Attached to
- BioRad QX200 Droplet Digital PCR System
- Solicitation number
- 75F40126Q00195
About this file
This is a Statement of Work for the procurement of a BioRad QX200 Droplet Digital PCR System by the Food and Drug Administration (FDA) Office of Applied Microbiology and Technology. The Government requires one (1) BioRad QX200 system to support DNA and RNA analyses for microbial contaminant identification, detection, quality control, and quantification in genomic microbiology research, specifically for identifying and quantifying viral nucleic acids from food and produce wash water samples prior to next-generation sequencing and whole genome microarray applications. The requirement represents a replacement of an aging existing system currently in use for validated workflows and ongoing foodborne virus research, including hepatitis A virus detection and quantification.
The system must be delivered within 30 days after award to FDA, 8301 Muirkirk Road, Laurel, MD 20708 during normal business hours (Monday-Friday, 8:00 AM - 4:00 PM). The contractor shall provide the complete system including manual droplet generator, droplet reader, computer, software, installation, training, initial operational verification, and one-year manufacturer warranty. Technical requirements specify the system must process up to 96 samples per run with completion times of 2-3 hours, require no more than 5 microliters of sample input per analysis, and provide fully compatible integration with existing QX200 instrumentation and proprietary consumables. An optional one-year post-warranty service plan is available covering preventive and corrective maintenance, software and firmware updates, with 24-48 hour service request acknowledgment and two-business-day on-site support response for corrective maintenance. The base period of performance runs from 7/1/26-6/30/27, with an optional year one extending from 7/1/27-6/30/28. All contractor personnel must comply with FDA facility security requirements, including advance notification, badging, sign-in procedures, and continuous escort while on-site.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Combo Synopsis-Solicitation Biorad sam.doc | DOC document | |
| Brand Name Justification SAM.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Need Purchase of a BioRad QX200 Droplet Digital PCR System
Purpose The Government requires the purchase of one (1) BioRad QX200 droplet digital PCR system to support DNA and RNA analyses focused on microbial contaminant identification, detection, quality control and quantification for genomic microbiology research conducted by the Office of Applied Microbiology and Technology (OAMT).
The system will be used to determine viral nucleic acid identification and concentration post extraction of viral genome target(s) from food and produce wash water prior to downstream applications including next-generation sequencing (NGS) and whole genome microarray, and comparison to results obtained from alternate detection systems such as qPCR.
This requirement represents the replacement of an aging BioRad QX200 droplet digital PCR system that is the platform currently in use to establish laboratory validated workflows, data systems, and ongoing research activities.
Background OAMT (Division of Food Safety Genomics) currently operates a heavily used and aging QX200 droplet digital system dedicated to the experiment analyses and methods development for the detection and quantification of RNA derived from foodborne viruses such as hepatitis A virus. This instrumentation is integrated into validated standard operating procedures (SOPs), quality control workflows, and ongoing genomic research protocols within the foodborne virus research/methods development program.
BioRad QX200 droplet digital PCR system is required to ensure compatibility with existing instrumentation, proprietary QX200 consumables, comparison to validated analytical methodologies, and established updated data systems. Use of an alternative manufacturer’s platform would require revalidation of laboratory methods and could adversely impact data comparability, workflow continuity, and ongoing research, methods development activities. Due to the use of proprietary consumables and validated methods specific to the QX200 platform, alternative systems are not considered technically acceptable without significant revalidation effort.
Minimum Technical Requirements
1. Supply Requirement – QX200 Droplet Digital PCR System The Contractor shall provide one (1) QX200 Droplet Digital PCR System configured application of established methods and development of new methods development for the detection and quantification of RNA derived from foodborne viruses, as well as for DNA and RNA quantification and quality control analysis.
1.1 System Configuration
The system shall:
· The system shall be a Bio-Rad QX200 Droplet Digital PCR system that is fully compatible with existing QX200 instrumentation, consumables, and validated laboratory workflows.
· Include manual droplet generator, droplet reader, computer, software, one year warranty with instrument purchase, and associated component consumables, for EvaGreen or probe-based digital PCR systems.
· Include delivery, installation and training, and initial operational verification.
1.2 Functional Capabilities
The system shall:
· Perform droplet generation and quantitative analysis of DNA and RNA samples.
· Generate quantitative concentration measurements.
· Produce droplet sampling, partitioning, size segregation/exclusion, and counting for digital analysis of positive and negative samples/droplets with digital and graphic/image outputs suitable for intra- and inter sample quantitative analyses and comparisons for quantity distribution profiles. Provide results in formats relevant for downstream applications such as next-generation sequencing (NGS), whole genome microarray, and qPCR analyses and workflows.
1.3 Performance Characteristics
The system shall:
· Process up to ninety-six (96) samples per run.
· Deliver complete analyses for a 96-samples run in 2 to 3 hours depending on the configuration of output, and any associated preliminary analyses.
· Require no more than 5 µL of sample input per analysis.
· Provide reproducible droplet sizing, partitioning, within run quality analyses, and quantification of results consistent with manufacturer specifications.
1.4 Software Requirements
The system shall include manufacturer-provided software capable of:
· Automated data acquisition and analysis.
· Will include but not limited to tabular formatted (e.g. excel) and distribution profiles in both chart and graph formats, in both digital and image outputs suitable for intra- and inter sample quantitative analyses and comparisons for quantity distribution profiles.
· Concentration calculation and droplet size exclusion.
· Data exported in formats compatible with existing laboratory data systems.
1.5 Compatibility Requirements
The system shall:
· Be fully compatible with existing QX200 Droplet Digital PCR system instrumentation.
· Utilize proprietary QX200 Droplet Digital PCR system consumables currently in use within the laboratory.
· Integrate with validated laboratory standard operating procedures (SOPs), quality control thresholds, and established data workflows.
Compatibility with existing Government-owned QX200 instrumentation, QX200 proprietary consumables, and validated laboratory methods, existing datasets, and established data analysis workflows is a minimum technical requirement necessary to maintain data integrity and continuity of laboratory operations.
1.6 Delivery and Acceptance
The Contractor shall:
· Deliver the system to the location specified in the contract during normal Government business hours.
· Coordinate installation with the Government point of contact.
· Confirm system operational status following installation.
Final acceptance will occur upon successful installation and verification that the system meets the requirements stated herein.
2. Maintenance Requirement – QX200 Droplet Digital Reader Service Plan for Droplet Digital Reader w/Man DG OS.
The Contractor shall provide a one (1) year service plan following the expiration of the manufacturer warranty, including preventive and corrective maintenance in accordance with manufacturer specifications.
2.1 Preventive Maintenance
Preventive maintenance shall be performed in accordance with manufacturer specifications as part of the service plan.
2.2 Corrective Maintenance
The Contractor shall provide under the 1-year warranty and service agreement:
· Corrective maintenance shall be performed in accordance with manufacturer specifications.
· Replacement parts that are original equipment manufacturer (OEM) parts.
· Contractor shall provide advance notice to the COR before any scheduled preventive maintenance visit, including the name(s) of any personnel who will be accessing the FDA facility.
2.3 Service Response and Support
· The contractor shall acknowledge all service requests with 24-48 hours of notification.
· For corrective maintenance requiring on-site support, a qualified service engineer shall be on-site within two (2) business days after initial request, unless otherwise scheduled with the COR.
2.4 Software and Firmware Updates
Software and firmware updates shall be provided as part of the manufacturer’s service plan.
2.5 Documentation
· Following any maintenance visit, the contractor shall confirm and document in writing that the equipment has been returned to OEM specifications before departing the FDA facility. Written/Email confirmation should be provided to the COR within 1-2 business days upon completion of each visit.
2.6 Qualified Personnel
All services shall be performed by qualified personnel in accordance with manufacturer’s requirements.
Deliverables
Table 1. Deliverables / Schedule
Deliverable Quantity Delivery Date
One (1) QX200 Droplet Digital PCR System, includes manual droplet generator, droplet reader, computer, software, installation and training, one year warranty after installation and Government acceptance
Within 30 days after award
| Option Year: One (1) year service plan (post-manufacturer warranty) for QX200 Droplet Digital Reader and Manual Droplet Generator (excludes computer) |
| 1 |
| To be exercised if funding is available |
Shipping Destination Michael Kulka FDA, 8301 Muirkirk Road, Laurel, MD 20708 The delivery or services must be during regular business hours (Monday-Friday) during the times of 8:00 AM – 4:00 PM, excluding holidays.
Period of Performance
Base Period (Equipment + Manufacturer Warranty): 7/1/26-6/30/27
Option Year One: 7/1/27-6/30/28
Place of Performance
All work associated with this requirement will be performed at FDA, 8301 Muirkirk Road, Laurel MD 20708
Security Considerations
The Contractor shall provide the full name(s) of all personnel requiring access to FDA facilities in advance of each visit to facilitate security processing and escort coordination.
All Contractor personnel must comply with FDA facility access requirements, including sign-in procedures, badging, and escort policies, upon arrival.
Contractor personnel shall remain under escort at all times while installing, training, and servicing the instrument.