Statement of Work_optical spectrum analyzer 2025 IE.pdf

PDF 225 KB Posted

Attached to
NB686010-25-01360 Optical Spectrum Analyzer Federal contract opportunity
Solicitation number
NB686010-25-01360
Issued by
Department of Commerce National Institute of Standards and Technology

About this file

This Statement of Work (SOW) details the National Institute of Standards and Technology's (NIST) requirement for an Optical Spectrum Analyzer (OSA) for the Sources and Detectors Group. The OSA must have specific technical specifications, including wavelength coverage of 350-1100 nm, ability to accept multimode fibers up to 800 um core size, a measurement noise floor better than -75 dBm, a dynamic range of 60 dB or better, and wavelength resolution of better than 30 pm.

The item will be delivered to NIST in Boulder, CO, with an estimated 2-week government acceptance period for performance metrics evaluation. The solicitation is for a complete OSA system that meets the detailed specifications in an attached document. Delivery is to be made to Michelle Stephens at the National Institute of Standards and Technology, with contact information provided. No specific training, maintenance, repair, or travel requirements are noted, and the document indicates these sections are not applicable (N/A).

View the file

Other files for this federal contract opportunity

Other files attached to NB686010-25-01360 Optical Spectrum Analyzer, newest first.
File Type Posted
NIST OSA_Details specs_28Feb2025.pdf PDF
NB688000-25-01360 Optical Spectrum Analyzer RFQ Small Business.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

St at em en t o f W o rk

Statement of Work: Optical Spectrum Analyzer 1

Last Saved: 4/17/2025 1:29 PM Double-click on for further assistance.

Use this Statement of Work document to purchase an item and/or item-related services.

TITLE: Optical Spectrum Analyzer Requesting Lab/Division/Group: PML, 686.01

Requisition Number: [to be entered by PR preparer]

Statement of Need The NIST Sources and Detectors Group requires an optical spectrum analyzer (OSA) for visible to near-IR wavelength range to characterize the emission spectrum of free-space and fiber-coupled lasers used in laser power and energy meter calibrations. The OSA needs to have wavelength coverage of 350 – 1100

nm. We require the OSA to accept multimode fibers with upto 800 um fiber core size at the optical input port of the instrument. The acceptable OSA system needs to have a measurement noise floor of better than – 75 dBm and a measurement dynamic range equal to or better than 60 dB. The acceptable OSA unit also needs to achieve actual wavelength resolution of better than 30 pm across the specified wavelength range.

Items and/or item-related services Section Requirements Related Information Items/Service

(required)

Optical Spectrum Analyzer system that meets all detailed specification in the attached document

☒ See attached document for detailed specifications

Enter related information here

Shipping &

Delivery ☐ N/A

Item to be delivered to NIST in Boulder, CO

USA

☐ Phased delivery is acceptable

☐ Software on USB / disk required

☐ Software electronic delivery acceptable Email address for software delivery

Michelle Stephens Mail Stop 686.01 National Institute of Standards and Technology 325 Broadway Boulder, CO michelle.stephens@nist.gov 303-905-7438

Installation ☒ N/A

Installation requirements

☐ Site visit recommended

Enter related information here

Inspection and Acceptance

☐ N/A

System must meet all technical specifications upon delivery

☒ Government acceptance expected to take longer than 7 days

We estimate 2 weeks to set up and evaluate performance metrics

Warranty

☒ N/A

Choose an item.

If you require an Extended Manufacturer Warranty, describe the warranty requirements.

Period Length:Ex. month, 6 month, year etc.

Enter related information here

☐ Option Period 1 ☐ Option Period 2

St at em en t o f W o rk

Statement of Work: Optical Spectrum Analyzer 2

Last Saved: 4/17/2025 1:29 PM Double-click on for further assistance.

☐ Option Period 3 ☐ Option Period 4

Training

☒ N/A

Training requirements Enter related information here

Maintenance

☒ N/A

Describe your maintenance requirements.

☐See attached document for detailed maintenance specifications

Period Length: Ex. month, 6 month, year etc.

Enter related information here

☐ Option Period 1 ☐ Option Period 2

☐ Option Period 3 ☐ Option Period 4

Repair

☒ N/A

Choose an item.

Describe your repair requirements.

Period Length: Ex. month, 6 month, year etc.

Enter related information here

☐ Option Period 1 ☐ Option Period 2

☐ Option Period 3 ☐ Option Period 4

Government Furnished Material / Equipment

☒ N/A

List any government furnished material/equipment here

Enter related information here

Travel

☒ N/A

Describe any travel requirements

Vendor: To the maximum extent possible, include as part of appropriate sections above (maintenance, repair, etc.).

Otherwise, it will be a separate line item, reimbursable per the Federal Travel Regulation.

Enter related information here