Statement of Work and Specifications.pdf
PDF 2 MB Posted
- Attached to
- Lateral Move Irrigation System
- Solicitation number
- 1232SA26Q0680
About this file
This document is a Statement of Objectives (SOO) for the installation of a lateral move sprinkler irrigation system with variable rate irrigation (VRI) controls at the USDA Agricultural Research Service facility in Kimberly, Idaho. The primary requirement is a hose feed, electric cord lateral move irrigation system to be installed on a 20-acre field (Field 1), with an optional identical system for installation on an adjacent field (Field 2).
Field 1 specifications include a 660-foot wide by 1,300-foot long configuration with water supply from an existing 8-inch buried mainline and 3-phase 480 VAC power sourced 480 feet south and 680 feet west of the southwest corner. The system must consist of four spans with equal lengths, except the first span may be longer to provide a dry travel lane for the main cart located on the west side. The system requires GPS-guided navigation, sprinkler outlets spaced at 30 to 40 inches with variable rate control sprinklers at 80 to 110 inch spacing, and water supply via two 5-inch diameter soft hoses from risers located approximately 325 feet from the field center. Each sprinkler must be equipped with a Nelson Irrigation 15 psi pressure regulator and olive plate rotator sprinkler, mounted at 60 inches above soil surface via poly hard drop hoses. The VRI control system must support water-controlled solenoid valves, programming of multiple stopping points with on/off water control, up to 10 sequential speed changes along the travel length, and remote monitoring via computer or smartphone. Maximum travel speed at 100% timer setting is 9 to 12 feet per minute. Power supply uses SOOW electrical cord with pedestals adjacent to each water supply riser, including 110-volt single phase outlets. The optional Field 2 system is identical to Field 1 with one water supply riser and one 480-volt electrical pedestal, with water potentially supplied by pipeline extension from Field 1 or from an existing 10-inch buried mainline in the southwest corner of Field 2.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Site Visit Sign-In 06032026.pdf | ||
| SF30 - Amend 01.pdf | ||
| Site Visit Sign-In 06042026.pdf | ||
| SF-1442.pdf | ||
| Wage Determination.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
The USDA Agricultural Research Service in Kimberly, Idaho, requires a new lateral move sprinkler irrigation system with variable rate irrigation (VRI) controls to be installed on a 20-acre field for research use. An option is included for a second identical VRI lateral move system to be installed on an adjacent field.
System Requirements
1. Hose feed, electric cord lateral move irrigation system installed in Field 1 (Figure 1).
2. Field dimensions are approximately 660 ft wide and 1300 ft long. Southwest corner of the field is located approximately lat. 42.551747°, long. -114.352698°. Contractor must verify actual distances in the field.
3. Maximum travel distance is 1300 ft.
4. Pressurized water source is from existing 8-inch buried mainline located approximately in the center of the west side of Field 1 (Figure 2).
5. 3 Phase 480 VAC power source is located at the irrigation pump, located approximately 480 ft south and 680 ft west of the southwest corner of Field 1 (Figure 3).
6. The system lateral to consist of 4 spans. All spans should be equal length except the first span can be longer to provide dry travel lane for main cart. The main cart is to be located along the west side of the field.
7. The main irrigation cart can be 2 or 4 wheeled.
8. Guidance system is to be controlled by GPS.
9. Outlet spacing on the sprinkler pipe is to be 30 to 40 inches. Sprinklers with variable rate control will be evenly spaced at 80 to 110 inch spacing. Additional outlets will be plugged for possible future modifications and research applications.
10. Two water supply risers are to be installed along the west side of Field 1using buried 125 psi PVC pipe. Each riser will be approximately 325 ft from the field center (Figure 1).
11. Water supply to lateral move system from the riser is to be by 5-inch diameter soft hose.
Two hoses are to be provided, one for each water supply riser.
12. Electrical power supply to the later move system is to be SOOW electrical cord.
13. Lateral system 480 V electrical supply pedestals are to be located adjacent to each water supply riser. Each electrical pedestal also includes a 110v single phase outlet.
14. The lateral irrigation system shall include a variable rate irrigation control system with individual sprinkler control to control water application to irregular shaped irrigation management zones.
15. VRI will have water-controlled solenoid values.
16. Each sprinkler control valve will be equipped with a poly hard drop hose to provide a sprinkler height of 60 inches above the soil surface.
17. Each sprinkler shall be equipped with a Nelson Irrigation 15 psi pressure regulator and
Nelson Irrigation olive plate rotator sprinkler.
18. Maximum travel speed of the lateral irrigation system at 100% timer setting is to be between
9 to 12 feet per minute.
19. The variable rate irrigation system controller is to be capable of programming multiple stopping points along the travel length with on/off water control.
20. The variable rate irrigation system controller will provide programming of system travel speed at specified locations along the travel length for up to 10 speed changes to be sequentially executed over the lateral travel length.
21. The variable rate control system will provide remote monitoring and control using a computer or smart phone.
Optional second lateral move irrigation system
1. Identical four-span, variable rate, lateral move irrigation system as installed on Field 1.
2. Second system will be installed on Field 2, directly south of Field 1(Figure 4).
3. One water supply riser and one 480 V electrical supply pedestal are to be installed in the center of the west side of Field 2.
4. Pressurized water source can be supplied by extending the pipeline from Field 1 or from an existing 10-inch buried mainline in the southwest corner of Field 2 (Figure 5).
5. Water supply to the lateral move system will be one, 5-inch diameter soft hose.
6. 3 Phase 480 VAC power source to be supplied from Field 1.
7. Electrical power supply to the later move system will be SOOW electrical cord.
Figure 1. Field 1 where lateral move irrigation system will be installed. Distances and locations of water supply, risers, and electric supply are approximate.
Figure 2. Existing irrigation out-dive on west side of Field 1. Buried mainline is 8-inch PIP pipe.
Photo taken looking south.
Figure 3. Electric supply from 3-phase 480v electrical panels for irrigation pump with variable frequency drive.
Optional second lateral move system
Figure 4. Field 2 where optional second lateral move irrigation system will be installed. Irrigation water can be supplied by extending pipe from Field 1 or from existing out-dive in the southwest corner of Field 2. Distances and locations of water supply, risers, and electric supply are approximate.
Figure 5. Existing irrigation out-dive in southwest corner of Field 2. Buried mainline is 10-inch PIP pipe.