This document is a Statement of Need for 1180 feet of continuous flex twisted pairs shielded polyurethane data cable to replace damaged cables for the E-4B Klaxon system. The cable must meet or exceed specific requirements for construction, technical data, and other features such as EMC characteristics, abrasion resistance, and flexibility.
The related federal contract opportunity is a solicitation from the 55th Contracting Squadron at Offutt AFB, Nebraska to procure the required data cable. This is a Request for Quotes (RFQ), and offers must be submitted by the specified due date to the listed points of contact. All quoted items must meet or exceed the specifications outlined in the Statement of Need.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 52.212-1 Instruction to Offerors.pdf | ||
| 52.212-2 Evaluation Factors for Award.pdf | ||
| Solicitation - FA460024Q0029.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF NEED
1st Airborne Command and Control Squadron
Data Cable
This requirement is for replacement cable for the E-4B Klaxon. The existing cable no longer functions it is damaged and unable to be repaired. The provided items shall meet or exceed the following requirements:
- 1180 feet of continuous flex twisted pairs shielded polyurethane data cable for small bending radius
- Data cable must meet or exceed the following salient characteristics:
Construction:
o Conductor: bare copper strands, extra fine wires o Insulation: PVC, TI2 acc. to EN 50363-3 + VDE 0207-363-3 o Color code: acc. to color code US 3, see page O/27 o Stranding: conductors twisted to pairs, pairs twisted in specially adjusted layering with non-woven tape over each layer o Shielding: tinned copper braiding o Wrapping: non-woven tape o Jacket material: PU acc. to UL 758 with matte surface o Jacket color: grayish tan (RAL 703
Technical data:
o Peak operating voltage: max. 350 V o Voltage UL/CSA: 300 V o Testing voltage: conductor/conductor: 1500 V conductor/shielding: 1200 V o Min. bending radius/continuously flexing: 7.5 x O.D.
o Radiation resistance: 5 x 107 cJ/kg o Temperature range: DIN VDE UL/CSA: up to +80°C static: -30/+70°C flexing +5/+70°C o Burning characteristics: flame retardant and self-extinguishing acc. to UL FT1, CSA FT1, FT2 o Oil resistance: very good- oil rating 60°C acc. to UL 758 o Chemical resistance: good against acids, alkalines, solvents, hydraulic liquids, etc.
o Approvals: UR AWM, CSA AWM, CE, EAC, RoHS o Absence of harmful substances: acc. to RoHS directive of the European Union
Other features:
EMC characteristics High abrasion resistance Good flexibility
Specs:
o 1180 feet in cumulative length o Number of pairs: 14 o Nominal inch: 0.563 o Outer- Ø mm: 14.3 o Cable weight lbs/mft: 160
Contractor shall provide description brand item that meet or exceeds requirements above.
Contractor shall include any warranties provided on equipment, shipping price to Offutt AFB NE and delivery dates after receipt of order in their quote.