About this file
This document outlines requirements for a federal contract to purchase area detectors and calibration equipment. CONS is seeking to acquire three area monitors, at least one with a pump and two without, to deploy during hazardous materials or confined space incidents. The detectors must have a run time of at least seven days, integrate sensors for PID, LEL, CO, H2S, and O2, use LENS wireless technology, have rechargeable batteries, communicate up to 1000 feet, be compatible with SAFER One modeling software, include a 3 button keypad, log data for 3 months at 10 second intervals, have IP66 ingress protection and impact-resistant polycarbonate case materials, and operate from -4 to 131 degrees Fahrenheit with 15-95% non-condensing humidity. They should also include a 4.4-inch display, 108dB alarm, redundant LEDs, charging equipment, one docking station, and a set of calibration equipment. The related solicitation was issued by the Air Force Air Combat Command under number FA460023Q0032 for area detectors at Offutt AFB.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 52_212-1 and 52_212-2 Area Detectors.docx | DOCX document | |
| COMBO Solicitation - FA460023Q0032.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Need
55 CONS is looking to purchase 3 Area Monitors and calibration equipment for deployment during hazardous materials and/or confined space incidents.
In the event of a real or perceived Hazardous Materials incident, the 3 detectors could be deployed in remote locations closer to the threat to monitor conditions and identify hazardous conditions.
During confined space incidents the detectors can be placed near the entry and continually monitor conditions in and around the space, alerting emergency response personnel if/when conditions change.
Detector Specifications:
· 1 Area Monitor with Pump
· 2 Area Monitors without Pump
· At least 7 Day run time
· All Detectors
· Sensors:
· PID
· LEL
· CO
· H2S
· O2
· LENS Wireless Technology
· Rechargeable nickel-metal hydride (NiMH) Battery
· Ability to communicate with each other up to 1000 feet
· Compatible with SAFER One Dynamic Plume Modeling Software
· 3 Button Keypad
· Data Log of at least 3 months at 10 second intervals
· Even Logging
· Ingress Protection Rating of IP66
· Case Material of Impact-Resistant Polycarbonate Alloys
· Temperature Range of -4 Degrees F to 131 Degrees F
· Humidity Range of 15% to 95% non-condensing
· 4.4-inch display
· 108dB alarm at 3.3 feet
· Redundant visual LED Alarm
· Charging Equipment with Power Cord
· 1 Docking Station
· 1 Set of Calibration Equipment