SR600_OEH-8P_A Hale approved.pdf
PDF 573 KB Posted
- Solicitation number
- RFQ1509695r1
About this file
This document is a site plan and scope of work for a septic system replacement project for the Indian Health Service located in Mayetta, Kansas. The project involves abandoning an existing septic tank in place, installing a new 1,000-gallon septic tank with access risers and lids, replacing 80 feet of sewer pipe with 4" Schedule 40 PVC pipe, installing a new 2-way cleanout within 5 feet of the house foundation, clearing trees in and around the lagoon area, and repairing or replacing fence as needed. The proposed work is for a 3-bedroom home with an associated garage and shed, located at 15613 N Road.
The project is a small business set-aside under NAICS code 237110, with a solicitation number RFQ1509695r1. The period of performance is 60 calendar days from the Notice to Proceed. Quotes are due by June 18, 2025, at 5:00 p.m. CST, with an estimated award amount under $25,000. Quotes will be evaluated on an acceptable/non-acceptable basis, with ranking proceeding from lowest to highest price and technical acceptability. The Indian Health Service will award the contract to the responsible, responsive offeror offering the lowest reasonable price while meeting all technical specifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SR600_SOW_A Hale.pdf | ||
| SR600_Bid Sheet_A Hale.pdf | ||
| Construction Clauses-DEVIATION FEB 2025.docx | DOCX document | |
| SF18-95a Request for Quote-r1.docx | DOCX document | |
| KS152.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SSLSSLSSL
X
X
X
X
15613 N
- R
O
AD
ABANDON EXISTING SEPTIC TANK
IN PLACE.
80 FEET OF SEWER PIPE
TO BE REPLACED WITH
4" SCHEDULE 40 PIPE
REMOVE TREES ALONG 315 FEET
OF LAGOON FENCE AND LAGOON AREA
REPAIR FENCE WHERE NEEDED.
PROPOSED LOCATION FOR
NEW 1,000 GALLON
SEPTIC TANK
3BDRM
HOME
GARAGE
SHED
SCOPE OF WORK:
* ABANDON EXISTING SEPTIC TANK
IN PLACE
* FURNISH AND INSTALL A NEW
1,000 GALLON SEPTIC TANK WITH
ACCESS RISERS AND LIDS OVER
INLET AND OUTLET BAFFLES.
* REPLACE 80 FEET OF SEWER
PIPE WITH 4" SCHEDULE 40 PVC
PIPE.
* FURNISH AND INSTALL A NEW
2-WAY CLEANOUT WITHIN 5 FEET
OF HOUSE FOUNDATION.
* CLEAR TREES IN AND AROUND
LAGOON
* REPAIR OR REPLACE FENCE
WHERE NEEDED DUE TO TREE
REMOVAL.
INSTALL A 2-WAY CLEANOUT
WITHIN 5 FEET OF HOUSE
FOUNDATION
IN
D
IA
N
HEA LTH SER
V
ICE
1 9 5 5
NOT TO SCALE
Ted A.
Schlueter -S
Digitally signed by Ted A. Schlueter -S Date: 2025.02.04 14:54:27 -06'00'
File details come from the government source that posted it. Updated .