Attachment 0003 - MIL-DTL-53126 (4A M60).pdf
PDF 101 KB Posted
- Attached to
- NSN: 6150-01-598-5289, Distribution System M60 Federal contract opportunity
- Solicitation number
- SPRBL1-20-Q-0012
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A19-SPRBL1-20-Q-0012-0002 01-07-2020.pdf | ||
| SPRBL120Q0012-0001.pdf | ||
| SPRBL1-20-Q-0012.pdf | ||
| Exhibit A - Technical Requirements Document.pdf | ||
| Attachment 0002 - MIL-DTL-53126A.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMSC N/A FSC 6150
Distribution Statement A. Approved for public release, distribution is unlimited.
INCH-POUND
MIL-DTL-53126/4A
16 October 2012
SUPERSEDING
MIL-E-53126(ME)
20 April 1992
DETAIL SPECIFICATION SHEET
POWER DISTRIBUTION, ILLUMINATION SYSTEMS, ELECTRICAL
DISTRIBUTION SYSTEM, 60 AMPS/PHASE (A/P)
This specification is approved for use within US Army Research Development and Engineering Command, Communications and Electronics Research and Development Center, Product Realization Directorate, Department of the Army and is available for use by all Departments and Agencies of the Department of Defense.
The requirement for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-53126.
1 SCOPE
1.1 Scope. This specification sheet covers the detail requirements for the Power Distribution Illumination Systems Electrical (PDISE), Type IV, model: M60, NSN: 6150-01-307-9445.
2 APPLICABLE DOCUMENTS
2.1 Drawings. The following Government drawings form a part of this specification sheet to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation.
DRAWING# NOMENCLATURE DRAWING # NOMENCLATURE
CECOM & PM-MEP Drawings - Cage Code: 97403 and 30554
13229E6352 Distribution System, Electrical, Single Phase, 60 Amperes/Phase
13229E6340 Connector Assembly 40 AMP/PH Input Plug
(Copies of drawings required by contractors in connection with specific acquisition functions should be obtained from: PROJECT MANAGER-MOBILE ELECTRIC POWER, 5850 Delafield Road, Bldg 324 FT BELVOIR VA 22060-5809.)
Source: http://assist.dla.mil -- Downloaded: 2019-02-04T13:23Z Check the source to verify that this is the current version before use.
3 REQUIREMENTS
3.1 Requirements. The M60, Type IV, PDISE shall be a self-contained, free-standing, man portable unit. The system shall be capable of distributing 60 Amps of current to all its outputs simultaneously, as specified herein.
Type III – 60 ampere distribution system
3.2 Design. The M60 PDISE shall be IAW TA13229E6352 and as specified herein.
3.2.1 Dimensions. The M60 PDISE shall not be greater than the following dimensions:
Length (Inches) Width (Inches) Height (Inches)
24.00 21.00 18.00
3.2.2 Weight. The M60 PDISE shall weigh no more than 45 pounds.
3.2.3 M60 PDISE inputs. The M60 PDISE shall have a single phase input capable of handling 60 A/P.
3.2.3.1 Input circuit interrupter. The input circuit for the M60 PDISE shall be protected from overload by a properly sized circuit breaker. The circuit breaker shall act as a switch to activate/deactivate the circuit.
3.2.3.1.1 Input connector. The M60 PDISE shall have a 60 ampere, single phase, male, input receptacle IAW 13229E6340.
3.2.4 M60 PDISE outputs The M60 PDISE shall have the following output circuits and connectors:
Quantity Output Rating Ouput Connector P/N*
1 60 Amp, 1 phase M90556C32405P
6 20 Amp, 1 phase M3406D16-10S
*Note: See 3.3.16.1 in MIL-DTL-53126.
3.2.4.1 Output circuit interrupters. Each output circuit shall be protected by a properly sized circuit breaker interrupter. The circuit breaker shall act as a switch to activate/deactivate the circuit.
3.2.5 Type IV accessories. The unit shall be provided with the following accessories:
Quantity Description Reference*
1 Input interface cable assembly, rated at 60 amperes 3.3.18.1*
1 60 A/P cable assembly 3.3.18.5*
3 20 A/P cable assemblies (25 ± 0.25 feet long) 3.3.18.6*
3 20 A/P cable assemblies (50 ± 0.25 feet long) 3.3.18.6*
2 Transition cable assemblies 3.3.18.8*
6 Cinching Strap 3.3.19.1*
2 Double strap assemblies 3.3.19.3*
1 Receptacle assembly 3.3.17*
1 In-Line GFCI 3.3.18.10*
1 Container 2.1
*Note: See requirement paragraph referenced MIL-DTL-53126.
CARRYING
STRAPS
CINCHING
STRAPS
CARRYING
STRAPS
MARKING TAG
(WHITE)
JOINING
STRAP
1.50 STK
10.00
27.75
4.75 3x 1.50
JOINING
STRAP
BB
LINE NEUT
BB BB
GND
G2
A
N
G1
J2 OUTPUT
FEED THRU
J2G6GND
J2A4LINE
J2N4NEUT
J2G6GND
60 A 1 PHASE
INPUT J1
J1G6GND
J1N4NEUT
J1A4CB1
G1
N
A
G2 J1G6GND
CB1
CB14LINE
20 A 1 PHASE
OUTPUT J3
J3C12GND
J3B12NEUT
J3A12CB3
C
B
A
CB3
CB312LINE
20 A 1 PHASE
OUTPUT J5
J5C12GND
J5B12NEUT
J5A12CB5
C
B
A
CB5
CB512LINE
CB8
J8
C
B
A
OUTPUT
20 A 1 PHASE
J8C12GND
J8B12NEUT
J8A12CB8 CB812LINE
CB6
A
B
C
J6 OUTPUT
20 A 1 PHASE
J6A12CB6
J6B12NEUT
J6C12GND
CB612LINE
CB4
A
B
C
J4 OUTPUT
20 A 1 PHASE
J4A12CB4
J4B12NEUT
J4C12GND
CB412LINE
DS1NBB DS1CB1
DS1
LIGHT BRACKET
CIRCUIT BREAKER
MOUNTING PANEL
TOP COVER
CHASSIS GROUND
J7 OUTPUT
20 A 1 PHASE CB7
CB712LINE
C
B
A
J5C12GND
J7B12NEUT
J7A12CB7
3.3 This specification sheet had no superseding “base”. The original publication of this specification was a performance specification that was used in-house by CR4. Since this specification is now a detailed military specification, this specification sheet is deemed necessary to capture the unique characteristics desired in the end item.
3.4 Changes from previous issues: Marginal notations are not used in this revision to identify changes with respect to the previous issue because this detail specification sheet although a part of the base document, was not published because it was a document with limited circulation and coordination that was used essentially by CR4.
Concluding Material
Custodian:
Preparing Activity:
Army - CR4 Army - CR4 (Project 6150-2012-013)
Review Activities:
DLA – GS
Note: The activities listed above were interested in this document as of the date of this document.
Since organization and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.dla.mil.
| 1 SCOPE |
| 1.1 Scope. This specification sheet covers the detail requirements for the Power Distribution Illumination Systems Electrical (PDISE), Type IV, model: M60, NSN: 6150-01-307-9445. |
| 2 APPLICABLE DOCUMENTS |
| 2.1 Drawings. The following Government drawings form a part of this specification sheet to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. |
| NOMENCLATURE |
| 3 REQUIREMENTS |
| 3.1 Requirements. The M60, Type IV, PDISE shall be a self-contained, free-standing, man portable unit. The system shall be capable of distributing 60 Amps of current to all its outputs simultaneously, as specified herein. |
| 3.2 Design. The M60 PDISE shall be IAW TA13229E6352 and as specified herein. |
| 3.2.1 Dimensions. The M60 PDISE shall not be greater than the following dimensions: |
| 3.2.2 Weight. The M60 PDISE shall weigh no more than 45 pounds. |
| 3.2.3 M60 PDISE inputs. The M60 PDISE shall have a single phase input capable of handling 60 A/P. |
| 3.2.3.1 Input circuit interrupter. The input circuit for the M60 PDISE shall be protected from overload by a properly sized circuit breaker. The circuit breaker shall act as a switch to activate/deactivate the circuit. |
| 3.2.3.1.1 Input connector. The M60 PDISE shall have a 60 ampere, single phase, male, input receptacle IAW 13229E6340. |
| 3.2.4 M60 PDISE outputs The M60 PDISE shall have the following output circuits and connectors: |
| *Note: See 3.3.16.1 in MIL-DTL-53126. |
| 3.2.4.1 Output circuit interrupters. Each output circuit shall be protected by a properly sized circuit breaker interrupter. The circuit breaker shall act as a switch to activate/deactivate the circuit. |
| 3.2.5 Type IV accessories. The unit shall be provided with the following accessories: |
| *Note: See requirement paragraph referenced MIL-DTL-53126. |
3.3 This specification sheet had no superseding “base”. The original publication of this specification was a performance specification that was used in-house by CR4. Since this specification is now a detailed military specification, this specificatio...
| Reference* |
| Description |
| Quantity |
| 3.3.18.1* |
| Input interface cable assembly, rated at 60 amperes |
| 1 |
| 3.3.18.5* |
| 60 A/P cable assembly |
| 1 |
| 3.3.18.6* |
| 20 A/P cable assemblies (25 ± 0.25 feet long) |
| 3 |
| 3.3.18.6* |
| 20 A/P cable assemblies (50 ± 0.25 feet long) |
| 3 |
| 3.3.18.8* |
| Transition cable assemblies |
| 2 |
| 3.3.19.1* |
| Cinching Strap |
| 6 |
| 3.3.19.3* |
| Double strap assemblies |
| 2 |
| 3.3.17* |
| Receptacle assembly |
| 1 |
| 3.3.18.10* |
| In-Line GFCI |
| 1 |
| 2.1 |
| Container |
| 1 |