Additional ordering data: All slow strain rate tests used to satisfy the requirements of QQ-N-286G must be done by one of the approved laboratories listed below.

Vendor acknowledgement of K-Monel Heat Review attachment applies.

3.

The following laboratories have participated in the round robin of studies of this strain rate test discussed above, have a set of photographs illustrating grain boundaries that have intergranular fracture features, and have demonstrated their ability to do the slow strain rate test. All slow strain rate tests done to satisfy the requirements of ref. (c) must be done by one of the approved laboratories listed below:

Huntington Alloys, a Special Meta1~ Company

Attn:

Frank Veltry

3200 Riverside Drive

Huntington, WV 25705

Phone:

(304) 526-5759

FAX~

(304) 526-5973

Metallurgical consultants, Inc.

Attn W. M. Buehler

4820 Caroline

P0 l3ox 88046

Houston. TX 77288-0046

Phone:

(713) 526-6351

FAX:

(713) 526-2964

Naval Surface Warfare Center, Carderock

Attn:

Eric Pocht

Code 614

9500 Macarthur Blvd

West Bethesda, MD 2083.7-5700

Phone:

(301) 227-5032

FAX:

(301) 227-5576

Teledyne Ailvac

Attn:

Dr. W. D. Cao

2020 Ashcraft Ave.

Monroe, NC 28110

Phone:

(704) 289-4511

Fax:

(704) 289-4269

Mannesmann Rôhrenwerke

Mannesmann Porschungsinstitut (MPI)

Attn: Dr. Weiss

Postfach 251160

47251 Duisburg

Germany

Phone:

011-49-0203-9993194

Fax:

011-49-0203-9994415

Vendor Acknowledgement of K-Monel Heat Review

Enclosure (2)

I. Recent investigations into mechanical property failures of fasteners manufactured from NiCuAI (K-Monel) material that was produced by Special Metals Corporation (formerly INCO Alloys) of Huntington, West Virginia has found eighty (80) heats of material which may not meet the mechanical property requirements of QQ-N-286 throughout the heat. In 1994, Special Metals Corporation implemented a process change that eliminated the addition of extra aluminum at the toe of each NiCuAl (K-Monel) ingot resulting in the toe’ portion of the heat being non-homogeneous in comparison to the rest of the heat. Due to cropping practices at Special Metals Corporation, material from the toe of the ingot with non-homogeneous aluminum content was not cropped from production material prior to shipment. A recent study has shown that the aluminum concentration in the toe portion of the ingot could be as low as approximately 2.0% with corresponding yield strength as low as approximately 40,000 PSI. QQ-N-286 specifies an aluminum content of 2.3% minimum and a yield strength of 90,000 PSI minimum or 85,000 PSI minimum for material = 1”. As a result of the investigation, the eighty (80) heats listed in Table I are considered suspect of having problems with insufficient aluminum content and an inability to consistently attain the required minimum yield strength.

2. You are requested to review your records of in stock and in process K-Monel material from the Special Metals Corporation for the suspect heat numbers listed in Table I below. You are prohibited from providing raw stock or finished products made from the suspect K-monel heats. If suspect heats are intended to be used, contact the PHNS & IMP contracting officer for adjudication of the material.

Table I - List of Suspect Special Metals Corporation K-Monel Heat Numbers

M00J6KG

M00J7KG

M01J1KG

M02J8KG

M02J9KG

M03J8KG

M04J2KG

M04J6KG

M04J7KG

M06J5KG

M06J8KG

M11J2KG

M11J3KG

M11J4KG

M11J5KG

M15J6KG

M17J2KG

M17J3KG

MI7J4KG

M18J7KG

M19J7KG

M21J2KG

M22J7KG

M22J8KG

M23J2KG

M24J5KG

M26J8KG

M26J9KG

M27J9KG

M28J4KG

M30J9KG

M3 1J9KG

M33J7KG

M34H4KG

M3SH0KG

M35J0KG

M35J7KG

M35H8KG

M36H7KG

M36J2KG

M36J3KG

M37J4KG

M39J3KG

M4IJIKG

M4IJ2KG

M4IH3KG

M41J3KG

M4IJ7KG

M4IJ8KG

M44J4KG

M44J6KG

M45J2KG

M45J8KG

M4SJ9KG

M46J7KG

M52H9KG

M6IJ8KG

M6139KG

M62J5KG

M64J4KG

M64J5KG

M64J6KG

M67H2KG

M67J4KG

M69JIKG

M70J6KG

M73J4KG

M76H6KG

M80H2KG

M80H3KG

M84119KG

M85H0KG

M88H6KG

M88H7KG

M89H5KG

M89H6KG

M92H0KG

M95H7KG

M97H8KG

M99H3KG

File details come from the government source that posted it. Updated .