SPMYM218Q0202

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 1449 - CONTINUATION SHEET

SOLICITATION/CONTRACT FORM

The required response date/time has changed from 16-Jan-2018 02:00 PM to 23-Jan-2018 02:00 PM.

SUPPLIES OR SERVICES AND PRICES

SUBCLIN 0002AB

The unit of issue has changed from Cylinder to Gallon.

SUBCLIN 0003AB

The CLIN extended description has changed from:

MONTHLY RENTAL FOR CONTRACTOR OWNED GP 160 LITER DEWAR TANK (ARGON, NITROGEN, OXYGEN).NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

To:

MONTHLY RENTAL FOR CONTRACTOR OWNED GP 160 LITER DEWAR TANK (ARGON).NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

The unit of issue has changed from Cylinder to Months.

SUBCLIN 0003AC

MONTHLY RENTAL FOR MINIMUM 1500 LITER MICRO BULK TANK (ARGON, CARBON DIOXIDE, NITROGEN) TO BE UTILIZED FOR CARRIER AVAILABILITY. RENTAL SHALL INCLUDE A VAPORIZER AND REGULATOR CAPABLE OF BEING SET TO 350 PSIG. RENTAL SHALL INCLUDE REGULAR MAINTENANCE OF TANK.NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

MONTHLY RENTAL FOR MINIMUM 1500 LITER MICRO BULK TANK (NITROGEN) TO BE UTILIZED FOR CARRIER AVAILABILITY. RENTAL SHALL INCLUDE A VAPORIZER AND REGULATOR CAPABLE OF BEING SET TO 350 PSIG. RENTAL SHALL INCLUDE REGULAR MAINTENANCE OF TANK.NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

SUBCLIN 0003AE

SUBCLIN 1002AB

SUBCLIN 1003AB

MONTHLY RENTAL FOR GP 160 LITER DEWAR TANK (ARGON, NITROGEN, OXYGEN).NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

MONTHLY RENTAL FOR CONTRACTOR OWNED GP 160 LITER DEWAR TANK (ARGON).NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

SUBCLIN 1003AC

MONTHLY RENTAL FOR 1500 LITER MICRO BULK TANK (ARGON, CARBON DIOXIDE, NITROGEN) TO BE UTILIZED DURING CARRIER AVAILABILITY. RENTAL SHALL INCLUDE A VAPORIZER AND REGULATOR CAPABLE OF BEING SET TO 350 PSIG. RENTAL SHALL INCLUDE REGULAR MAINTENANCE OF TANK.NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

MONTHLY RENTAL FOR MINIMUM 1500 LITER MICRO BULK TANK (NITROGEN) TO BE UTILIZED FOR CARRIER AVAILABILITY. RENTAL SHALL INCLUDE A VAPORIZER AND REGULATOR CAPABLE OF BEING SET TO 350 PSIG. RENTAL SHALL INCLUDE REGULAR MAINTENANCE OF TANK.NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

SUBCLIN 1003AE

SUBCLIN 2002AB

SUBCLIN 2003AB

MONTHLY RENTAL FOR GP 160 LITER DEWAR TANK (ARGON, NITROGEN, OXYGEN).NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

MONTHLY RENTAL FOR CONTRACTOR OWNED GP 160 LITER DEWAR TANK (ARGON).NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

SUBCLIN 2003AC

MONTHLY RENTAL FOR 1500 LITER MICRO BULK TANK (ARGON, CARBON DIOXIDE, NITROGEN) TO BE UTILIZED DURING CARRIER AVAILABILITY. RENTAL SHALL INCLUDE A VAPORIZER AND REGULATOR CAPABLE OF BEING SET TO 350 PSIG. RENTAL SHALL INCLUDE REGULAR MAINTENANCE OF TANK.NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

MONTHLY RENTAL FOR MINIMUM 1500 LITER MICRO BULK TANK (NITROGEN) TO BE UTILIZED FOR CARRIER AVAILABILITY. RENTAL SHALL INCLUDE A VAPORIZER AND REGULATOR CAPABLE OF BEING SET TO 350 PSIG. RENTAL SHALL INCLUDE REGULAR MAINTENANCE OF TANK.NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

SUBCLIN 2003AE

SUBCLIN 3002AB

SUBCLIN 3003AB

MONTHLY RENTAL FOR GP 160 LITER DEWAR TANK (ARGON, NITROGEN, OXYGEN).NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

MONTHLY RENTAL FOR CONTRACTOR OWNED GP 160 LITER DEWAR TANK (ARGON).NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

SUBCLIN 3003AC

MONTHLY RENTAL FOR 1500 LITER MICRO BULK TANK (ARGON, CARBON DIOXIDE, NITROGEN) TO BE UTILIZED DURING CARRIER AVAILABILITY. RENTAL SHALL INCLUDE A VAPORIZER AND REGULATOR CAPABLE OF BEING SET TO 350 PSIG. RENTAL SHALL INCLUDE REGULAR MAINTENANCE OF TANK.NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

MONTHLY RENTAL FOR MINIMUM 1500 LITER MICRO BULK TANK (NITROGEN) TO BE UTILIZED FOR CARRIER AVAILABILITY. RENTAL SHALL INCLUDE A VAPORIZER AND REGULATOR CAPABLE OF BEING SET TO 350 PSIG. RENTAL SHALL INCLUDE REGULAR MAINTENANCE OF TANK.NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

SUBCLIN 3003AE

SUBCLIN 4002AB

SUBCLIN 4003AB

MONTHLY RENTAL FOR GP 160 LITER DEWAR TANK (ARGON, NITROGEN, OXYGEN).NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

MONTHLY RENTAL FOR CONTRACTOR OWNED GP 160 LITER DEWAR TANK (ARGON).NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

SUBCLIN 4003AC

MONTHLY RENTAL FOR 1500 LITER MICRO BULK TANK (ARGON, CARBON DIOXIDE, NITROGEN) TO BE UTILIZED DURING CARRIER AVAILABILITY. RENTAL SHALL INCLUDE A VAPORIZER AND REGULATOR CAPABLE OF BEING SET TO 350 PSIG. RENTAL SHALL INCLUDE REGULAR MAINTENANCE OF TANK.NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

MONTHLY RENTAL FOR MINIMUM 1500 LITER MICRO BULK TANK (NITROGEN) TO BE UTILIZED FOR CARRIER AVAILABILITY. RENTAL SHALL INCLUDE A VAPORIZER AND REGULATOR CAPABLE OF BEING SET TO 350 PSIG. RENTAL SHALL INCLUDE REGULAR MAINTENANCE OF TANK.NOTE: Max quantity stated is changed to estimated quantity, max amount is changed to estimated amount, and max net amount is changed to estimated net amount.

SUBCLIN 4003AE

The unit of issue has changed from 50 Pound Bag to Months.

The following have been modified:

STATEMENT OF WORK

INDUSTRIAL GASES AND TANK/EQUIPMENT RENTAL AND MAINTENANCE

1. Scope

1.1. General Description. Puget Sound Naval Shipyard and Intermediate Maintenance Facility (PSNS & IMF) detachment in Naval Air Station North Island, San Diego CA and Submarine Base Point Loma requires a broad range of bottled gases, bulk gases, and tank/equipment rentals delivered Just-in-Time, from the Contractor’s distribution center(s) to multiple sites within NASNI and Point Loma. The products and tank/equipment rentals will be utilized in the NASNI Depot Maintenance Facility (DMF) operations, CNO availabilities and Continuous Maintenance.

1.2. Contract Type. The contract shall be for one-year base period and (4) one-year option periods and shall be a Firm Fixed Price Indefinite Delivery Indefinite Quantity Type Contract (IDIQ). Ordering will be made through issuance of written delivery orders, unless otherwise authorized by a warranted Contracting officer.

2. References (Applicable Standards and Certificate of Analysis (COA) Requirements). The Contractor is required to comply with all standards and specifications of all items listed below.

Note: Per paragraphs 3.3 and 4.8, Contractor shall provide COA for gases detailed in paragraphs 2.4 and 2.5, at no additional cost to the Government, as follows:

Double (**) indicates upon delivery of each lot of gas delivered.

Single (*) indicates when requested by the Government as follows.

Bulk Gases in Liquid Form: The vessel in which the gas is originated from, delivered in, or to, at the Government’s direction shall be treated as follows:

· Quarantine: The vessel will be quarantined by the Government, the Contractor will be notified of the need for a COA, the Contractor will have 2 (two) business days to obtain a sample of the vessel gas, and as additional 2 (two) business days to analyze and provide the COA.

· Transfer of Custody: The vessel will be quarantined by the Government, the Contractor will be notified of the need for a COA, the Contractor will have 2 (two) business days to take custody of the vessel, and as additional 2 (two) business days to analyze and provide the COA. In this circumstance, the Contractor will use a “Chain of Custody” form for proper tracking.

High-Pressure Cylinders in Gaseous Form: When required by paragraph 3.3 and 4.8 a COA shall be provided within two (2) business days, when requested, as follows:

· Industrial Gas (Para. 2.4): COA for High-Pressure Cylinder Industrial Gases shall reference the original bulk supply COA.

· Mixed Welding Gas (Para. 2.5) and Argon (Para 2.4): Per paragraph 3.3, the Government expects that each lot of High-Pressure Cylinder Welding Gas will have 1 (one) cylinder tested and used as the basis for the COA for the entire lot.

2.1. MIL-STD 1411, Inspection and Maintenance, Cylinders

2.2. MIL-STD 101B, Paint

2.3. ANSI/ASQ Z1.4, Sampling for Test and Inspection

2.4. Industrial Gas. Gases per this contract shall be of a commercially available grade with the exception of those listed below, which shall comply with and meet all of the physical and quality assurance requirements of the cited specifications. Failure of any one container constitutes failure of the entire lot.

2.4.1 BB-A-106D Grade B, Technical, Dissolved, Dated 12-27-10, Acetylene - Gaseous*

2.4.2 MIL-A-18455, Technical, Dated 07-07-91, Argon - Liquid and Gaseous*

2.4.3 BB-C-101C Grade B, Technical and USP, Dated 03-07-11, Carbon Dioxide (CO2) - Liquid*

2.4.4 BB-H-1168D Grade A, Technical, Dated 11-15-10, Helium - Gaseous*

2.4.5 Federal Spec BB-H-886, Hydrogen - Gaseous*

2.4.6 CID A-A-59155, Grade A, Dated 03-05-03, Nitrogen - Liquid and Gaseous*

2.4.7 CGA G-10.1-2008, Grade L, Nitrogen - Liquid and Gaseous**

2.4.8 MIL-PRF-27210J, Dated 08-07-13, Oxygen, Aviators Breathing – ABO **

2.5 Welding Gas. All Mixed Gases per AWS A5.32. If the gas mixture requested is not listed in AWS A5.32 for gas mixtures, the applicable military or Federal Specification for single component gases may be used with the tolerance of mixture and dew point requirements of Table 3 and Table 4 of AWS A5.32.

2.5.1 75% Argon/25% CO2 Mixture *

2.5.2 90% Argon/10% CO2 Mixture *

2.5.3 95% Argon/5% CO2 Mixture *

2.5.4 75% Argon/25% Helium Mixture *

2.5.5 95% Argon/5% Helium Mixture *

2.5.6 95% Argon/5% Hydrogen Mixture *

2.5.7 98% Argon/2% Oxygen Mixture *

3. Objective Quality Evidence (Reports)

3.1. Certificate of Conformance (COC) - Bulk or Micro Bulk Storage Tanks (COC - A form that states the product or item conforms to the requirements of a specification). Contractor shall establish and maintain COCs for each contractor owned tank they supply, control, or maintain for this contract for the duration of the contract.

3.1.1. The COC shall be established by the contractor to validate the tank is certified for storage of a particular gas type, when the tank is inducted into use for this contract.

3.1.2. The contractor shall establish a new COC when a tank currently in use for storage of a specific gas type is changed to storage of another gas type.

3.1.3. Contractor shall provide COC for tanks when requested by the Government within two (2) business days.

3.2. Certificate of Conformance – Gases. Contractor shall provide, at no additional cost to the Government, COC verifying that all lots of gas conform to all gas specifications, both liquid and gaseous, as referenced in paragraphs 2.4 and 2.5. The COCs shall be provided to the Contracting Officer (KO) and the Contracting Officer’s Representative (COR) within five (5) business days of contract award and within five (5) business days of renewal/exercise of any contract option year, and within two (2) business days as changes occur, or when otherwise requested by the Government.

3.2.1. Contractor format is acceptable and at a minimum the gas COC shall be signed by qualified Contractor Personnel and shall include the wording: “THE (GAS TYPE) SUPPLIED TO PSNS & IMF UNDER (CONTRACT) MEETS THE REQUIREMENTS OF (SPECIFICATION NUMBER/TITLE). “

3.2.2. Contractor may also provide supplemental COCs provided to the Contractor from an authorized official of a subcontractor or manufacturer.

3.2.3. Contractor shall immediately notify the KO and COR in the event Contractor becomes unable to provide gases per specifications referenced in paragraphs 2.4 and 2.5.

3.2.4. Furnishing of the COC by the Contractor shall not limit or restrict the Government’s right of inspection under the inspection provisions of the contract.

3.3. Certificate of Analysis (COA) - (An authenticated document issued by the Contractor’s Quality Assurance Group that establishes that a regulated product has met its product specification and quality). The Contractor shall:

3.3.1. Perform chemical test/analysis of each gaseous and liquid lot (as defined below) of gas supplied in performance of this contract per specifications referenced in paragraphs 2.4 and 2.5. Lot test records shall be traceable from the lot vessel markings to the COA and shall be retained for the duration of the contract.

3.3.2. Produce written COAs that include test data/chemical analysis break out showing elements tested for and that indicate conformance to specifications based on actual chemical tests performed for each lot.

3.3.3. Provide COAs to the COR at no additional cost to the Government as indicated in paragraphs 2.4 and 2.5. See Note of paragraph 2 for periodicity.

3.3.4. Contractor format is acceptable and at a minimum the COAs shall be signed by qualified Contractor personnel and shall include the following:

· Government Contract Number

· Lot Number

· Gas Type

· Vessel Marking/Serial Number (if cylinder)

· Analytical Results

· The statement: “THE (GAS TYPE) SUPPLIED TO PSNS & IMF UNDER (CONTRACT) MEETS THE REQUIREMENTS OF (SPECIFICATION NUMBER/TITLE)”

3.3.5. For COC and COA Quality Assurance and testing requirements a “Lot” shall be defined by the specifications referenced in paragraphs 2.4 and 2.5.

3.3.6. Lot definition exception: For the purposes of quality conformance for paragraphs 2.4.2, 2.4.3, and 2.5, or where no specification exists, or where no clear definition of a lot exists, the following shall apply:

· Bulk Gas: The entire amount of gas generated as the original bulk supply in one shipping container shall constitute a lot.

· High-Pressure Cylinders in Gaseous Form for welding gases of para. 2.5: Every Cylinder filled from the same source on the same day shall constitute a lot.

3.4. Reports. Contractor shall prepare and submit the following reports to the KO and the COR within five (5) business days after end of reporting period, at no additional cost to the Government. Contractor format is acceptable. In addition to specific report data fields, all reports shall include:

· Contractor’s Name and Address

· Contract Number

· Report Title

· Date of Report

· Reporting Period

· Name of Preparer and Telephone Number

3.4.1. Yearly Reporting Requirement

a. Certificate of Conformance (Gas) - See paragraph 3.2

b. POCs for Notification and Technical Assistance – See paragraph 4.4.10 Data fields:

· During business hours POC

· After business hours POC

c. To be submitted upon Contract award and upon each Option Year exercise, and at any time changes occur

3.4.2. Semi-Yearly Reporting Requirement

a. Semi-Yearly Government Owned Cylinder Inventory Report Data fields - Stratified by Cylinder Size and Gas Type:

· Quantity of Full cylinders

· Quantity of Empty cylinders

· Quantity of Out of Service cylinders

· Quantity of cylinders needing Scrapped

b. To be submitted Oct 1 & Apr 01

3.4.3. Quarterly Reporting Requirement

a. Quarterly Contractor Owned Equipment Rental Report Data Fields:

· Tank / Cylinder Size

· Gas Type

· Serial Number (Tanks Only)

· Location

b. To be submitted Q1= Oct-Dec, Q2= Jan-Mar, Q3= Apr-Jun, Q4= Jul-Sep

4. Requirements – All requirements herein to be performed at no additional cost to the Government.

4.1. Government Oversight. The Government shall perform periodic product testing and periodic (at least annually) audits of the Contractor's compliance to this contract. The Contractor shall make available all Quality Assurance and Quality Control records, and shall provide access to their facilities for these audits. The assigned COR will perform random surveillances on deliveries, monitor contractor’s performances, and review/approve reports and invoices.

4.2. Contractor Responsibility. The Contractor is responsible, either through its own resources or subcontractor, for the full range of logistic and customer-support processes including: product, tank (a vessel that holds liquid gas), cylinder (a vessel that holds gaseous gas), equipment pick-up and delivery, inventory management, certification and maintenance, warehousing, transportation, supplier relationships, technical compliance, quality assurance, customer service, order receipt and fulfillment, return processing, invoicing, data collection and reporting. High pressure cylinders shall be pressurized IAW commercial standards for cylinder types and sizes.

4.3. Qualified Personnel. The Contractor shall ensure all Contractor Personnel have qualifications specific to their duties, which shall be supported by licenses, permits, tests, statements of competency, or other documentation. Contractor shall retain records of those qualifications and provide when requested by the Government within five (5) business days.

4.4. Contractor Owned Equipment. All work detailed within paragraph 4.4 shall be done in such a manner as to minimize disruption of ongoing Government work. The Contractor shall:

4.4.1. Certify, install, maintain and keep all equipment used in performance of this contract in good operating condition in accordance with applicable standards, rules, regulations and good commercial practices. Contractor shall retain records of those activities for the duration of the contract and provide when requested by the Government within five (5) business days.

4.4.2. Tank/Equipment Connects/Disconnects. The contractor shall provide all connects and disconnects for bulk tanks.

4.4.3. Tank Installation and Removal. Tank installation and removal including crane support shall be the responsibility of the contractor.

4.4.4. Perform repair. For equipment needing non-emergent repair, as determined by either the Contractor or the Government, the Contractor shall have eight (8) business hours to notify/acknowledge the need and respond to the Government (by telephone allowed), two (2) business days to provide (at minimum) remote technical assistance and five (5) business days to have a qualified Contractor Technician at the Government site to satisfactorily remedy the issue.

4.4.5. Perform emergent maintenance/repair. For equipment requiring immediate attention due to safety or critical Government work evolutions, as determined by either the Contractor or the Government, the Contractor shall provide same day service to satisfactorily remedy the issue.

4.4.6. Replace or relocate equipment – Contractor determined.

a. If the Contractor determines that its equipment needs to be replaced or relocated for safety, maintenance, or need of access the Contractor shall immediately notify the KO and the COR.

b. A site for equipment needing relocated shall be coordinated between the Contractor and the COR.

c. Equipment relocated to perform maintenance shall be returned to its original location, unless otherwise agreed to by the COR.

4.4.7. Replace or relocate equipment - Government determined.

a. If the Government determines the Contractor’s equipment needs replaced, the Contractor shall have eight (8) business hours to acknowledge the need and respond to the Government (by telephone allowed), and five (5) business days for non-emergent replacement or twenty-four (24) clock hours for emergent replacement, unless otherwise agreed to by the COR. Replacement equipment shall be of the same type and capacity as that being replaced, unless otherwise agreed to by the KO for contract modification.

b. If the Government determines that the Contractor owned cryogenic micro-bulk tanks need relocating, the Government shall provide courtesy notice to the Contractor of such movement. Movement of the tanks shall be performed by the Government with technical guidance provided by the Contractor.

4.4.8. Notification of Work. Contractor shall provide a formal written report to the COR at least sixty (60) days prior to desired start date of work that will significantly disrupt the Government. The report shall describe the extent of work to be done, time to complete, personnel needed, and equipment required.

4.4.9. Temporary Services. Contractor shall provide temporary services during the removal, installation and/or prolonged maintenance of gas tanks.

4.4.10. Designated Technical Personnel. The Contractor shall provide the Government with points of contact for notification purposes and technical assistance for regular business hours and after business hours.

4.5. Damage/Loss of Equipment. If the Contractor discovers damage to or loss of Contractor’s equipment, Contractor shall notify the KO and the COR, in writing, of the damage or loss and shall provide all relevant details to include cost of repair or replacement.

4.6. Gas Identification (Cylinder). For cylinder gases requiring a COA, per paragraphs 2.4, 2.5, and 3.3, in addition to standard specification labeling requirements and precautionary information as required by federal, state, local, and provincial requirements, each cylinder shall have a tag, sticker, or bar code, affixed which includes the Lot Number- traceable to the Certificate of Analysis.

4.7. Bulk Tank Identification/Fill Log. All liquid gas mixing stations and associated fill tanks, as well as all liquid Argon tanks for welding gases, shall have a Fill Log affixed to the tank indicating:

· Lot Number

· Fill Date

· Fill Plant

· Product Filled

· Container Number

· Name of Technician

5. Delivery Schedule. Tanks to be refilled at approximately 30% tank level and deliveries required within 48 hour notice by the government. Delivery is expected to be made between 0700 to 1400. Vendor will provide 24-hour service and may be required to deliver outside normal business hours. The order will specify whether delivery is required outside of normal business hours and applicable CLIN for that delivery.

Delivery tickets are required for both written and oral orders. Vendor will provide a copy of the delivery ticket to the Shipyard point of contact (POC) or receiver upon completion of delivery. The delivery ticket will specify pertinent information, i.e., gas/product information or contract line item (CLIN) and quantity delivered. The Shipyard POC/receiver will print his name, sign, date and provide a badge number on the delivery ticket. The original copy will be kept by the vendor and a duplicate copy will be provided to the Shipyard POC/receiver. The unit of measurement for bulk gases in the delivery tickets shall be in gallons.

5.1. Cylinder Gases:

· NASNI- Delivery to be on demand

· Point Loma- Delivery to be on demand

5.2. Bulk Gases:

· NASNI- Within 48 hour notice by the government

· Point Loma- Within 48 hour notice by the government

6. Delivery Locations. Delivery locations subject to change as project requirements change. Due to the number of customers serviced by this contract, delivery locations and POCs shall be specified on each order.

6.1. Naval Air Station North Island – Controlled Industrial Area (CIA)

Location
Area

Pier J

Pier K

Pier L

Bldg. 71

Bldg. 72

Bldg. 73

Bldg. 431
Door 13

6.2. Submarine Base Point Loma

Location
Area

Bldg 633

7. Point(s) of Contact.

7.1 Contracting Officer (KO):

7.1.1 Michael Ozols, michael.ozols@dla.mil, 360-476-1012

7.2 DLA Puget Sound Contracting Officials:

Jo Ann Togioka, joann.togioka@dla.mil, 360-476-1510

7.3 Contracting Officer’s Representative (COR):

TBD

8. Estimated minimum and Maximum Number of Tank Rentals. Table identifies Gas Type, Size, minimum and maximum quantity of tanks that can be required based on project requirements. Microbulk and Stationary tank locations will be identified in each delivery order. Microbulk tank location may change as required by the project.

GAS TYPE
SIZE
ESTIMATED MINIMUM QTY
ESTIMATED MAXIMUM QTY
*Nitrogen
2,000 LI (Minimum)
2
4
**Nitrogen
450 LI (Minimum)
4
6

*Rental shall include a vaporizer and regulator capable of being set at 5 to 70 PSIG. Rental shall include regular maintenance of tanks.

**Rental shall include a vaporizer and regulator capable of being set at 225 to 300 PSI on wo (2) each of the tanks- one (1) for Building 72 and one (1) for Building 633. Rental shall include regular maintenance of tanks. Tanks must be less than 90 inch tall and fit within a 6 foot by 9 foot print. Tanks to be installed by Contractor upon delivery at location set by PSNS.

**Rental shall include a vaporizer and regulator capable of being set at 40 to 90 PSI on two (2) each of the tanks- one (1) for Building 72 and one (1) for Building 633. Rental shall include regular maintenance of tanks. Tanks must be less than 90 inch tall and fit within a 6 foot by 9 foot print. Tanks to be installed by Contractor upon delivery at location set by PSNS.