15-Q-0782-P0002.doc
DOC document 34 KB Posted
- Attached to
- TURN-KEY WIRE EDM Federal contract opportunity
- Solicitation number
- SPMYM2-15-Q-0782
About this file
ADDITIONAL VENDOR QUESTIONS REGARDING TECHNICAL SPECIFICATIONS AND RELATED ANSWERS. CLOSING DATE IS NOT EXTENDED.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 15-Q-0782-P0001.doc | DOC document | |
| SPMYM2-15-Q-0782-The_specification_of_new_generation_W_axis.pdf | ||
| Mandatory_Technical_Specifications_for_WIRE_EDM_-_SPMYM2-15-Q-0782.pdf | ||
| CDRL_for_CLIN_0001_SPMYM2-15-Q0782.pdf | ||
| SPMYM2-15-Q-0782.doc | DOC document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
The following have been added by full text:
ADDITIONAL VENDOR QUESTIONS
ADDITIONAL VENDOR QUESTIONS ON TECHNICAL SPECIFICATIONS AND RELATED ANSWERS:
QUESTION:
We observed that Amendment 2 was issued for the subject solicitation and included an answer related to maximum space requirement 3.4.3, Question 4 in VENDOR QUESTIONS ANSWERED.
The space requirements described equate to the measurements of the brand name described in CLIN item no. 0001. To allow best evaluation of Government requirements and possible solutions, can the Government describe the actual space allotted for the machine W x L x H?
ANSWER:
"I might be able to get 8-10" more on the width but we are placing this in between two existing machines so the space is very limited. The machine can be taller if needed as we have high ceilings."
(End of Summary of Changes)