SPLIT CASE DOOR DETAIL.PDF

PDF 223 KB Posted

Attached to
Framed Display Cases
Solicitation number
DQ1 GCAA 2019000250 1
Issued by
Denver County, Denver City, Colorado

About this file

This is a technical drawing document for a split case door detail, which appears to be a construction or manufacturing specification sheet rather than a traditional state and local contract opportunity document. The drawing, designated as CA-04.03-200 and dated September 17, 2018, provides detailed specifications for split case door configurations with fixed pane glass panels. The document illustrates both left-hand reverse swing and right-hand reverse swing door options, each featuring vertical trim rails and .375-inch glass panel thickness. The drawing is presented at a 1:50 scale and includes standard engineering specifications such as fractional and angular tolerances, two-place and three-place decimal tolerances, and geometric tolerancing requirements. The document is marked as proprietary and confidential, indicating it is the sole property of the issuing organization with reproduction prohibited without written permission.

No additional information regarding pricing terms, set-asides, incumbents, funding sources, contract terms, renewal options, response dates, bidder meetings, or award timelines is present in this document. This appears to be a technical specification sheet that would be included as a supporting exhibit or attachment within a larger contract opportunity or project package rather than a standalone contract solicitation document.

View the file

Other files

File Type Posted
DQ1 2019000250 Framed Display Cases.pdf PDF
HEADRESS CASE DOOR DETAIL.PDF PDF
HEADDRESS CASE GLASS SIZING.PDF PDF
ZIG ZAG CASE DOOR SWING.PDF PDF
ZIG ZAG CASE GLASS SIZING.PDF PDF
SPLIT CASE GLASS SIZING.PDF PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIXED PANE

FIXED PANE

FIXED PANE

VERTICAL

TRIM RAIL

REQUIRED VERTICAL

TRIM RAIL

REQUIRED

.375" GLASS PANEL THICKNESS

LEFT HAND REVERSE

SWING

RIGHT HAND REVERSE

SWING

A A

B B

SPLIT CASE

DOOR DETAIL

DO NOT SCALE DRAWING

CA-04.03-200

SHEET 1 OF 1

9/17/2018W.KING

UNLESS OTHERWISE SPECIFIED:

SCALE: 1:50 WEIGHT:

REVDWG. NO.

A

SIZE

TITLE:

NAME DATE

COMMENTS:

Q.A.

MFG APPR.

ENG APPR.

CHECKED

DRAWN

FINISH

MATERIAL

INTERPRET GEOMETRIC

TOLERANCING PER:

DIMENSIONS ARE IN INCHES

TOLERANCES:

FRACTIONAL

ANGULAR: MACH BEND

TWO PLACE DECIMAL

THREE PLACE DECIMAL

APPLICATION

USED ONNEXT ASSY

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF

<INSERT COMPANY NAME HERE>. ANY

REPRODUCTION IN PART OR AS A WHOLE

WITHOUT THE WRITTEN PERMISSION OF

<INSERT COMPANY NAME HERE> IS

PROHIBITED.

Sheet1
Drawing View1

File details come from the government source that posted it. Updated .