SPI - EH6C0398EH.pdf

PDF 200 KB Posted

Attached to
Cylinder Outrigger & Cylinder Assembly
Solicitation number
SPRDL1-26-R-0057
Issued by

About this file

This is a DD Form 2169, Special Packaging Instruction, issued in June 1997 for the preservation, packing, and shipping of a Cylinder Assembly (Part No. 6-372-002614, CAGE 12361, National Stock Number 3040-01-207-6376). The item has a unit pack weight of 306.0 pounds and dimensions of 48.0 x 14.5 x 14.3 inches, with a unit pack cubic volume of 5.760 cubic feet. The drawing revision is C, dated 04-30-09, with SPI No. AK12076376.

The packaging specifications require military preservation per MIL-STD-2073-1D, Method 20, with internal operational fluid as preservative, NAS834 closure, external preservation using MIL-PRF-16173 Grade 4, and MIL-PRF-121 Type II barrier material. Cleaning follows MIL-STD-2073-1D, C-1, with drying per MIL-STD-2073-1D. The item must be containerized in an ASTM-D 6880, Class 2, Style 2 container measuring 45 x 12-3/4 x 10 inches using ASMT-D 6199 blocking and bracing. Marking must comply with MIL-STD-129. Additional requirements include slushing and flushing internally, sealing all openings, applying preservative to unpainted metallic surfaces, and applying preservative between contact points. Page 2 provides detailed blocking and bracing specifications with six different blocking configurations (A through F) secured with ASTM-F 1667 nails, with specific dimensions and quantities for each piece.

View the file

Other files

File Type Posted
SPRDL126R0057.pdf PDF
SPI - EH6C0292EH.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DD FORM 2169, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 1 of 2 Pages

SPECIAL PACKAGING INSTRUCTION Form Approved OMB No. 0704-0188

-CL

The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS

1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.

6-372-002614 (12361) CYLINDER ASSEMBLY 19207 AK12076376

4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION

3040-01-207-6376 04-30-09 C

7. QUP 8. ICQ 9. UNIT PACK WT. (LB) 10. UNIT PACK CU (CU FT) 11. UNIT PACK SIZE (INCHES)

001 NONE 306.0 5.760 48.0 X 14.5 X 14.3

12. MILITARY PRESERVATION (METHOD) 18.

STEPS

19.

REQ’D

20.

DESCRIPTION

MIL-STD-2073-1D, METHOD 20 1-B PRESERVATIVE (INTERNAL): OPERATIONAL FLUID

13. CLEANING 2-C CLOSURE: NAS834

MIL-STD-2073-1D, C-1 3-D PRESERVATIVE (EXTERNAL): MIL-PRF-16173, GR 4

14. DRYING 4-E BARRIER: MIL-PRF-121, TYPE II, SIZE: AS REQUIRED

MIL-STD-2073-1D 5-F BLOCKING/BRACING: ASMT-D 6199, SEE SHEET 2

6 CONTAINER: ASTM-D 6880, CLASS 2, STYLE 2,

15. PACKING SIZE: 45 X 12-3/4 X 10

a. LEVEL A

MIL-STD-2073-1D

b. LEVEL B

NOT APPLICABLE

16. MARKING

MIL-STD-129

17. NOTES / DRAWING

A. PRESERVATION AND PACKING SHALL BE INSPECTED IN ACCORDANCE WITH MIL-STD-2073-1D.

B. SLUSH AND FLUSH INTERNALLY AND THOROUGHLY DRAIN EXCESS.

C. SEAL ALL OPENINGS WITH CAPS/PLUGS OF THE APPROPRIATE SIZE.

D. APPLY PRESERVATIVE TO ALL UNPAINTED EXTERIOR METALLIC SURFACES.

E. APPLY BETWEEN POINTS OF CONTACT OF ITEM WITH BLOCKING OR CONTAINER.

F. FOR FABRICATION AND PLACEMENT OF BLOCKING/BRACING SEE SHEET 2.

G. THE UNIT CONTAINER IS THE SHIPPING CONTAINER.

DD FORM 2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page 2 of 2 Pages

SPECIAL PACKAGING INSTRUCTION Form Approved OMB No. 0704-0188

-CL

The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS

1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.

6-372-002614 (12361) CYLINDER ASSEMBLY 19207 AK12076376

4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION

3040-01-207-6376 04-30-09 C

17. NOTES / DRAWING

NOTES:

1. ALL DIMENSIONS ARE IN INCHES

2. ALL SIZES ARE NOMINAL UNLESS OTHERWISE SPECIFIED.

3. ALL BLOCKING SHALL BE SECURED TO THE CONTAINER INTERIOR WITH NAILS CONFORMING TO ASTM-F 1667.

4. FABRICATE AND PLACE BLOCKING/BRACING “A” AS ILLUSTRATED, SIZE: 2 X 2-1/2 X 10, 2-REQUIRED.

5. FABRICATE AND PLACE BLOCKING/BRACING “B” AS ILLUSTRATED, SIZE: 2 X 8-3/4 X 10, 3-REQUIRED.

6. FABRICATE AND PLACE BLOCKING/BRACING “C” AS ILLUSTRATED, SIZE: 3 X 4 X 10, 1-REQUIRED.

7. FABRICATE AND PLACE BLOCKING/BRACING “D” AS ILLUSTRATED, SIZE: 3 X 4 X 12-3/4, 1-REQUIRED.

8. FABRICATE AND PLACE BLOCKING/BRACING “E” AS ILLUSTRATED, SIZE: 3 X 4 X 10, 1-REQUIRED.

9. FABRICATE AND PLACE BLOCKING/BRACING “F” AS ILLUSTRATED, SIZE: 3 X 4 X 12-3/4, 1-REQUIRED.

File details come from the government source that posted it. Updated .