Specifications_-_Plans_-_FDOT_Loop_Standard.pdf
PDF 529 KB Posted
- Attached to
- Transportation Traffic Signal Loop Services
- Solicitation number
- 24-0195-ITB
- Issued by
- Pinellas County, Florida
About this file
This document is a Florida Department of Transportation (FDOT) Standard Plan for Vehicle Loop Installation Details, specifically the FY 2023-24 Standard Plans indexed as 660-001. The two-page technical drawing provides comprehensive specifications and installation guidelines for vehicle detection loops in roadways, covering various loop types (A through G), installation methods with and without curb and gutter, and detailed technical requirements for loop lead-in cable installation. The standard plan includes precise diagrams illustrating loop placement, conduit routing, saw-cut techniques, and expansion joint considerations for different roadway configurations.
The technical specifications outline critical installation parameters, such as loop wire placement depths, conduit installation angles, splice connection methods, and specific requirements for different loop types centered in traffic lanes. Notable technical details include guidance on loop wire placement within saw-cuts, minimum distances between twisted pair lead-ins, nonmetallic hold-down material usage, and provisions for loop lead-in lengths less than or greater than 75 feet. The document is designed to provide uniform standards for traffic signal loop installations, ensuring consistent and reliable vehicle detection infrastructure across transportation projects.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Transportation_Traffic_Signal_Loop_Services.pdf | ||
| Non-Competitive_Oversight_Committee_Justification_Form.docx | DOCX document | |
| Specifications_-_Plans_-_Pinellas_County_Loop_Standard.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
/6 /2
:3
:2
P M
R E
V
IS
IO
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2023-24 SHEETINDEX
Twisted Pair or Loop Lead-In in Saw-Cut
Flexible Conduit
PVC Coated
Flexible Conduit
PVC Coated
Twisted Pair or Loop Lead-In in Saw-Cut
Rigid Conduit
Connector
Gutter Gutter
Edge of Roadway Slot
Twisted Pair or Loop Lead-In in Saw-Cut
Twisted Pair or Loop Lead-In in Saw-Cut
PVC Coated Flexible Conduit
PVC Coated Flexible Conduit
Slot (See General Note 8)
Roadway Pavement
Slot (See General Note 8)
Intermediate Pullbox Intermediate Pullbox
21660-001
VEHICLE LOOP INSTALLATION DETAILS
11/01/18
ALTERNATIVE 2
TWISTED PAIR AND LOOP LEAD-IN INSTALLATION
INSTALLATION WITHOUT CURB & GUTTER
INSTALLATION WITH CURB & GUTTER
To Pullbox or Cabinet
To Pullbox or CabinetTo Pullbox or Cabinet
ELEVATION
PLAN
ALTERNATIVE 1
NOTES:
the roadway is between 30° to 45°.
3. The departure angle of the conduit from
2" below the top of the roadway surface.
roadway pavement and approximately
2. Install the conduit at least 6" into the the end of the flexible conduit.
sufficient size and depth to snugly place
1. Cut a slot in the edge of the roadway of
GENERAL NOTES:
Operations Engineer.
8. Alternative installations may be approved by the State Traffic asphalt as directed by the Engineer.
7. Do not disturb more than a 6" x 6" area of asphalt. Restore exposed end of the shielded cable may be used.
that will accommodate both the splices of the conductors and the the shielded cable. As an alternate, a larger diameter enclosure conductor and place a third enclosure over the exposed end of insulated enclosures. Place one enclosure over the end of each
6. Splice Connections in pull boxes with UL listed, watertight, wire is 6" from the loop to 12" from the pavement edge or curb.
5. The minimum distance between the twisted pairs of loop lead-in intervals on lead-ins.
material approximately 12" intervals around loops and 24" lead-ins to the bottom of saw-cuts. Place the hold down
4. Use nonmetallic hold down material to secure loop wires and loop wires and lead-in cables in a saw cut in the structural course.
prior to the placement of the asphalt friction course. Place the loop wires and lead-in cables in the asphalt structural course
3. On resurfacing or new roadway construction projects, install the than 4" below the top of the final surface.
expansion joints, saw-cut to a standard depth of 3", but no more loop wires or lead-in cables into the saw-cut. Except across
2. Provide sufficient saw-cut width to allow unforced placement of wire and continue to the controller cabinet.
twisted pair an Intermediate Pullbox, splice to shielded lead-in cabinet. If the loop lead-in is greater than 75' continue the detector to controller cabinet, continue the twisted pair to the
1. If the loop lead-in is 75' or less from the edge of the loop
NOTES:
sealant from entering the flexible conduit.
5. Use a nonmetallic material to prevent excessive loop level of the curb surface.
4. Fill the top of the hole with loop sealant to the
3. Insure the conduit fits snug within the drilled hole.
not within 2" of the top of the hole.
into the hole from the back side of the curb but
2. Install a section of flexible conduit at least 6" prior to cutting the top inside edge of the curb.
the required saw-cut depth is obtained just
1. Drill a hole through the curb at the point which
NOTES:
sealant from entering the rigid conduit.
5. Use a nonmetallic material to prevent excessive loop roadway surface.
4. Fill the hole with loop sealant to the level of the the roadway surface.
3. Place the top of the rigid conduit approximately 2" below end of the rigid conduit.
2. Install a molded bushing (nonmetallic) on the roadway angle to intercept the trench or pull box hole.
(or concrete) surface and base at an appropriate rigid conduit to be used through the roadway asphalt
" to 1" larger in diameter than the 2
11. Drill a hole
/6 /2
:3
:2
P M
R E
V
IS
IO
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2023-24 SHEETINDEX
Pavement Joint Double Width Cut
Loop Wires
Sealant
Deep Section of Groove Over Wire
Soft-Setting Sealer Injected Into
Loop Wires
Type 'B'
Type 'B'
Shielded Lead-In
Type 'B'
Type 'B'
Stop Line
Stop Line Stop Line
Stop Line
Stop Line
Stop Line
Stop Line
2 Turns
3 Turns
2 Turns
4 Turns 2 Turns
4 Turns
2 Turns
2 Turns 4 Turns
2' 2'
3'-6"
2'
2'
3'
22660-001
VEHICLE LOOP INSTALLATION DETAILS
11/01/18
3"
2"
3'-6"
3"
CONCRETE PAVEMENT EXPANSION JOINTS
VERTICAL SECTION
PLAN
TYPE F
TYPE E
TYPE D
TYPE C
TYPE B
TYPE A
TYPE G
LOOP CORNER AND LEAD-IN DETAILS
3'3'
8'8'
Variable
6'
3'
6'
6'
Variable
6'
1' 1'1'
1'
1'
Variable
Variable
Variable
Variable
Items.
Under Separate Pay
Pullbox Specified
Loops To Pullbox.
NOTE:
LOOP TYPES, EXPANSION JOINTS, AND DETAILS
to bottom forming slack section at joint.
Loop conductors must follow saw-cut
NOTE:
LOOP TYPES
NOTES:
pull box with signal power cable.
Do not install loop lead-in wires in the same 7.
maximum of 60'.
length of these loops may be extended to a the stop line a maximum of 10' and the of loop Types A, C, D, & F may extend past
When shown in the Plans, the leading edge 6.
loop.
Lead-in may be connected to either end of 5.
loop may vary up to a maximum of four (4).
The number of individual loops in the Type G 4.
lanes.
except Type E which is centered on two
Loop Types are centered in a single lane 3.
Loop types or details not drawn to scale.2.
loop.
placed in the saw-cut forming the complete number of passes of loop wires which are specified point on the loop refers to the
The number of "Turns" indicated at the 1.
| Traffic Control Signals and Devices |
| 660-001-Vehicle Loop Installation Details |
| 660-001-1of2 |
| 660-001-2of2 |
File details come from the government source that posted it. Updated .