This document is a set of specifications for critical IT equipment required by the Indian Health Service (IHS) National Supply Service Center (NSSC) and Gallup Regional Supply Service Center (GRSSC). The key items needed are a PowerEdge R760 Server, Dell EMC SmartUPS, APC Rack PDU, 8-port KVM, external hard drive, and rack cooling system. The period of performance is 45 days from the award date. The contractor must provide new original equipment and all necessary accessories. Delivery, installation, and training must be coordinated with the designated government representative. The procurement is a 100% Native Owned Small Business Set Aside, with quotes due by 5/30/2024. Award will be made to the lowest priced, technically acceptable offer.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 1.docx | DOCX document | |
| GRSSC Server COMBINED SYNOPSIS SOLICITATION.pdf | ||
| BI Representation Form.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Department of Health and Human Services Indian Health Service
National Supply Service Center (NSSC)
Specifications GRSSC Critical IT Equipment
1. PURPOSE OF THE PROJECT
The Indian Health Services (IHS), National Supply Service Center (NSSC), and Gallup Regional Supply Service Center (GRSSC) have needs for a PowerEdge R760 Server, Dell EMC SmartUps, APC Basic Rack, 8 Port KVM, SIP: VGA, USB virtual media, Apricorn 4TB External Hard Drive, and Tripp Lite Rack Cooling system.
The National Supply Service Center Information Technology department has identified the need for Critical IT Infrastructure replacement and expansion of Gallup Regional Supply Service Center. The replacements, upgrades, and additions will align the needs specific to the National Supply Service Center mission that are critical to support and sustain the Information Technology demands of the rapid expansion of Federal, Tribal, and urban medical/pharmaceutical supply distribution around the country. The target is to adequately meet our current and future customer needs by providing excellent, reliable, interoperable health information services that protect privacy while connecting patients, providers, and payers, enabling improved patient outcomes and controlled costs in support of the IHS mission and providing a highly reliable and efficient health information system to support the delivery of health care to the American Indian and Alaska Natives that IHS serves.
2. DETAILED DESCRIPTION OF THE TECHNICAL REQUIREMENTS
The contractor shall provide new original equipment manufacturer (OEM) parts, while no aftermarket parts will be acceptable. Equipment shall be shipped directly from the manufacturer.
The following items will be required with the listed features.
One (1) PowerEdge R760 Server with the following features:
Category Description Code SKU ID Base PowerEdge R760 Server GYF30OW [210-BDZY] 1 Trusted Platform Module No Trusted Platform Module GMHJL5Y [461-AADZ] 1574 Chassis Configuration 3.5" Chassis with up to 12 SAS/SATA Drives, 2x2.5" Rear
SAS/SATA Drives, LP Adapter PERC 11, 2 CPU
GON0ZL4 [404-BBDQ] 1530
Processor Intel® Xeon® Silver 4416+ 2G, 20C/40T, 16GT/s, 37.5M Cache, Turbo, HT (165W) DDR5-4000
GB9S6ML [338-CHTH] 1550
Additional Processor Intel® Xeon® Silver 4416+ 2G, 20C/40T, 16GT/s, 37.5M Cache, Turbo, HT (165W) DDR5-4000
GZ9QIEX [338-CHTH] [379-BDCO] 1551
Additional Processor Features No HBM G68EUO7 [379-BFFD] 1515 Processor Thermal Configuration
Heatsink for 2 CPU configuration (CPU greater than 165W) GALJM2W [412-ABCP] 1697
Memory Configuration Type Performance Optimized GH9QBEI [370-AAIP] 1562 Memory DIMM Type and Speed
4800MT/s RDIMMs GGBEML0 [370-AHCL] 1561
Memory Capacity (4) 16GB RDIMM, 4800MT/s Single Rank GAD7JYE [370-AGZO] 1560 RAID Configuration C7, Unconfigured RAID for HDDs or SSDs (Mixed Drive Types
Allowed)
GJ45ICY [780-BCDS] 1540
RAID/Internal Storage Controllers
PERC H755 Adapter LP GESBYH3 [405-AAYY] 1541
National Supply Service Center (NSSC)
Hard Drives (5) 480GB SSD SATA Read Intensive 6Gbps 512 2.5in Hot-plug AG Drive,3.5inHYB CARR, 1 DWPD
G48QICJ [400-AXRJ] 1570
Hard Drives (PCIe SSD/Flex Bay)
(2) 480GB SSD SATA Read Intensive 6Gbps 512 2.5in Flex Bay AG Drive, 1 DWPD
G4R8YEO [400-AXTB] 1573
BIOS and Advanced System Configuration Settings
Performance BIOS Setting GJO594B [384-BBBL] 1533
Advanced System Configurations
UEFI BIOS Boot Mode with GPT Partition GSFTG4Y [800-BBDM] 1534
Advanced System Configurations
No Energy Star G9IONL3 [387-BBEY] 1534
Fans Very High-Performance Fan x6 G8Z3VLX [750-ADGJ] 1531 Power Supply Dual, Fully Redundant (1+1), Hot-Plug Power Supply 1400W, Mixed Mode
GEQZKW4 [450-AKYB] 1620
Power Cords (2) C13 to C14, PDU Style, 12 AMP, 6.5Feet (2m) Power Cord, North America
GC1DFVJ [492-BBDI] 1621
PCIe Riser Riser Config 7, 4x8 FH Slots (Gen5), 2x16 LP Slots (Gen4) GPI0QUL [330-BBYI] 1510 Motherboard Motherboard supports ONLY CPUs below 250W (cannot upgrade to CPUs 250W and above)
GSDP7V8 [329-BJLR] 1536
Embedded Systems Management iDRAC9, Enterprise 16G G16CQF5 [528-CTIC] 1520
OCP 3.0 Network Adapters Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0
G91LG8U [540-BCOD] 1518
Additional Network Cards LOM Blank G8ZQCPO [540-BDOW] 1514 Additional Network Cards Broadcom 57416 Dual Port 10Gb, Base-T, PCIe Adapter, Full
Height
G18GDMK [540-BBUI] 1514
NVMe and PCIe Storage Adapters
PERC H965e, Adapter Low Profile, DIB GR72T9P [405-BBBV] 1519
GPU/FPGA/Acceleration Cables
No Cables Required, No GPU Blanks G0PNZWL [470-AEYU] 1624
Bezel PowerEdge 2U LCD Bezel GCGY1KU [321-BHMY] [325-BETK] 1532 Boot Optimized Storage Cards
BOSS Blank G74DI3A [329-BERC] 1696
Quick Sync No Quick Syn GCLNJM4 [350-BBYX] 1695 Password iDRAC9 Force Change Password for OCP cards GMOPT80 [379-BETE] 1693 IDRAC Service Module iDRAC Service Module (ISM), NOT Installed GX95LG2 [379-BCQX] 1691 Group Manager iDRAC Group Manager, Disable GTVA94K [379-BCQY] 1692 Operating System No Operating System G78MU35 [611-BBBF] 1650 OS Media Kits No Media Required GKH7AZI [605-BBFN] 1652 Rack Rails ReadyRails Sliding Rails With Cable Management Arm GVERFZ7 [770-BDRQ] [770-BEKK] 1610 Server Accessories Fan Foam, HDD 2U GVYJO5Z [750-ACOM] 1630 System Documentation No Systems Documentation, No Open Manage DVD Kit GVRYSM7 [631-AACK] 1590 SHIPPING PowerEdge R760 Shipping GYD4WIN [340-DCEP] 1500 Shipping Material PowerEdge R760 Shipping Material G6RFPIW [340-DJQY] 1690 Regulatory PowerEdge R760 No CCC, No CE, and No BIS Marking GXF8GOT [343-BBSU] 1507 ECCN Decline Selection GRO1P6G [817-BBBP] 1705 Service 5 Years Pro support Next Business Day Onsite Service GSTCP87 [886-5641] [886-5650]
[886-5653][989-3439]
Keep Your Hard Drive 5 Years Keep Your Component For Enterprise GPEZ5XR [841-6043] 345 BIOS Settings - Standard A/C Power Recovery On ACON [366-0192] 200424 BIOS Settings - Standard Power Management - Maximum Performance PWRMAXP [366-0193] 200424 BIOS Settings - Standard User Accessible USB Ports - All Ports On UUSBON [366-0201] 200424
One (1) Dell EMC SmartUPS 4800W Rackmount UPS 208V Input: L6-30 / Output 2 X L6-30, 2 X L6-20 as listed:
Dell EMC SmartUPS 4800W Rackmount UPS 208V Input:
L6-30 / Output 2 X L6-30, 2 X L6-20
Category:
Dell SmartUPS 5000VA 208V – Rack/Tower
Manufacturer Part#:
DLRT5KRMXLT
Dell Part#:
A8572199
Catalog Number:
16 / A8572199
One (1) APC Basic Rack PDU – OU – 120V NEMA 5-15 Input / 14 X NEMA 5-15 Output as listed:
AP9567 APC Basic Rack PDU – OU – 120V NEMA 5-15 Input / 14 X NEMA 5-15 Output
APC Basic Rack PDU AP9567 – OU – 120V NEMA 5-15 Input / (14) NEMA 5-15 Output
Manufacturer Part#:
AP9567
Dell Part#:
A7541364
Catalog Number:
16 / A7541364
SKU: [A7541364]
National Supply Service Center (NSSC)
One (1) 8-port KVM as listed:
8 port KVM allows remote connectivity as well as KVM over IP
Dell Digital KVM Switch DMPU108e – TAA Compliant
Manufacturer Part#:
DMPU108E
Dell Part#:
A7546773
Catalog Number:
16 / A7546773
One (1) SIP: VGA, USB keyboard, mouse-supporting virtual media, CAC, and USB 2.0 as listed:
Server interface module SIP: VGA, USB keyboard, mouse-supporting virtual media, CAC, and USB 2.0
Manufacturer Part#:
DMPUIQ-VMCHS-G01
Dell Part#:
A7547276
Catalog Number:
16 / A7547276
One (1) Apricorn 4TB USB 3.0 Apricorn Aegis Padlock Fortress portable external hard drive as listed:
Apricorn 4TB USB 3.0 Apricorn Aegis Padlock Fortress portable external hard drive
Manufacturer Part#:
A25-3PL256-S4000F
Dell Part#:
AA900597
[AA900597]
One (1) Tripp Lite Rack Cooling / In Row Air conditioner 33K BTU as listed:
Tripp Lite Rack Cooling/ In Row Air Conditioner 33K BTU 208V / 240V 50/60Hz rack air-conditioning cooling system
Manufacturer Part#:
SRCOOL33K
Dell Part#:
A7836420
Catalog Number:
16 / A7836420
SKU: [A7836420]
3. PERIOD OF PERFORMANCE
45 days from the date of the award
4. LEVEL OF EFFORT
4.1 The contractor shall provide new equipment.
4.1. This should include all accessories to operate the equipment and features as listed to include, but not limited to:
4.1.1. Cables
4.1.2. Adapters
4.1.3. Batteries
4.2. The contractor shall deliver to the National Supply Service Center, Distribution Center, at 501 NE 122nd Street, Suite F, Oklahoma City, OK 73114 with all installation instructions, warranty documents, and specifications.
4.3. Training: The contractor shall provide an online resource for training and initial use.
5. SPECIAL REQUIREMENTS
5.1. In accordance with HHSAR 304.1300(b) non-routine contractor employees shall comply with OPDIV DHHS/SE Region – Human Resources, Security Clearance Guidance – Visitors (3/29/12) policy for contract performance period. Contractor employees will be required to obtain a visitor’s pass upon arrival for services from Facilities Management. - (Security Clearance for on-site human services)
National Supply Service Center (NSSC)
5.2. The US PHS National Supply Service Center (NSSC) and Gallup Regional Supply Service Center (GRSSC) are a tobacco/smoke-free environment (buildings and grounds). No tobacco/smoking use will be tolerated during service.
5.3. Security Requirements: Contractor personnel will be required to contact the government-designated point of contact upon arrival when reporting for service calls or delivery supplies. The contractor shall be responsible for the security of all organizational information. Current rules and regulations applicable to the premises, where the work shall be performed shall apply to the contractor and its employees while working on the premises. These regulations include but are not limited to, escort by National Supply Service Center (NSSC) or Gallup Regional Supply Service Center (GRSSC) officials, presenting valid identification, smoking restriction, and any safety procedures.
5.4. The contractor shall not disclose or cause to disseminate any information concerning the operations of the National Supply Service Center (NSSC) and/or Gallup Regional Supply Service Center (GRSSC).
Such action(s) could result in a violation of the contract and possible legal actions.
5.4.1. All inquiries, comments, or complaints arising from any matter observed, experienced, or learned of as a result of or in connection with the performance of the contract, the resolution of which may require the dissemination of official information, shall be directed to the government’s designated representative.
5.5. Termination Amortization Schedule: A termination amortization schedule shall be included as an attachment of the awarded contract. If the Government does not exercise any of the options listed in the price/cost schedule, the Government’s not exercising the options will have the same effect as if the Government terminated for convenience. All remedies afforded to the contractor in regard to a termination for convenience shall be available to the contractor.
6. DELIVERABLES AND REPORTING REQUIREMENTS
6.1. Delivery: The contractor will coordinate the delivery, installation, and training dates with the designated government employee. The government will provide the contractor with dock access and building access for this sole purpose. The designated government employee will work with the pertinent government agency(ies) to secure the needed dock access. No deliveries can be made after 3:15 pm. Driver needs a valid ID.
6.2. Contractor Point of Contact: The contractor shall furnish one designated point of contact (POC) to the government’s designated representative for coordination of supplies, delivery, and/or maintenance.
The POC will be empowered to make daily decisions to ensure that the contract implementation and day-to-day maintenance meet the terms and conditions of this contract.
6.3. Contractor’s Phone Numbers: The contractor shall provide a toll-free telephone number for service calls, which must be answered during at least eight working hours, between 7:00 am and 3:30 pm, Monday through Friday.
National Supply Service Center (NSSC)
7. GOVERNMENT-FURNISHED PROPERTY, FACILITIES AND SERVICES
7.1. The Government shall make no supply of property, facilities, and services.
8. CONTRACTOR FURNISHED PROPERTY, FACILITIES AND SERVICES
8.1. Required personnel, materials, supplies, and equipment: The contractor shall furnish all personnel, materials, supplies, and equipment required to perform work under the contract, including but not limited to equipment and shipping.
9. CHANGES TO THE SPECIFICATIONS
Any changes to these specifications shall be authorized and approved only through written correspondence from the Contracting Officer. Costs incurred by the contractor through the actions of parties other than the Contracting Officer shall be borne by the contractor.
10. DELIVERABLES/PERFORMANCE MATRIX
1. Provided quality customer service according to NSSC mission: Yes No
2. Met the terms of the SOW: Yes No
3. Vendor available and service requests answered timely (within one business day): Yes No
4. Issues were addressed and resolved in a timely manner (within 24 hours for non-operational equipment or 48 for Limited operations): Yes No
5. Invoices accurate and received timely: Yes No
NSSC IT:________________________
| Category: | |
| Description: | |
| Code: | |
| SKU: | |
| ID: | |
| Base: | |
| PowerEdge R760 Server: | |
| 210BDZY: | |
| 1: | |
| No Trusted Platform Module: | |
| 461AADZ: | |
| 1574: | |
| Chassis Configuration: | |
| GON0ZL4: | |
| 404BBDQ: | |
| 1530: | |
| Processor: | |
| GB9S6ML: | |
| 338CHTH: | |
| 1550: | |
| Additional Processor: | |
| GZ9QIEX: | |
| 338CHTH 379BDCO: | |
| 1551: | |
| No HBM: | |
| 379BFFD: | |
| 1515: | |
| Processor Thermal Configuration: | |
| Heatsink for 2 CPU configuration CPU greater than 165W: | |
| GALJM2W: | |
| 412ABCP: | |
| 1697: | |
| Performance Optimized: | |
| 370AAIP: | |
| 1562: | |
| 4800MTs RDIMMs: | |
| GGBEML0: | |
| 370AHCL: | |
| 1561: | |
| Memory Capacity: | |
| 4 16GB RDIMM 4800MTs Single Rank: | |
| 370AGZO: | |
| 1560: | |
| RAID Configuration: | |
| GJ45ICY: | |
| 780BCDS: | |
| 1540: | |
| RAIDInternal Storage Controllers: | |
| PERC H755 Adapter LP: | |
| GESBYH3: | |
| 405AAYY: | |
| 1541: | |
| Hard Drives: | |
| G48QICJ: | |
| 400AXRJ: | |
| 1570: | |
| G4R8YEO: | |
| 400AXTB: | |
| 1573: | |
| Performance BIOS Setting: | |
| GJO594B: | |
| 384BBBL: | |
| 1533: | |
| Advanced System Configurations: | |
| UEFI BIOS Boot Mode with GPT Partition: | |
| GSFTG4Y: | |
| 800BBDM: | |
| 1534: | |
| Advanced System Configurations_2: | |
| No Energy Star: | |
| G9IONL3: | |
| 387BBEY: | |
| 1534_2: | |
| Fans: | |
| Very HighPerformance Fan x6: | |
| 750ADGJ: | |
| 1531: | |
| Power Supply: | |
| GEQZKW4: | |
| 450AKYB: | |
| 1620: | |
| Power Cords: | |
| GC1DFVJ: | |
| 492BBDI: | |
| 1621: | |
| PCIe Riser: | |
| 330BBYI: | |
| 1510: | |
| Motherboard: | |
| GSDP7V8: | |
| 329BJLR: | |
| 1536: | |
| Embedded Systems Management: | |
| iDRAC9 Enterprise 16G: | |
| G16CQF5: | |
| 528CTIC: | |
| 1520: | |
| OCP 30 Network Adapters: | |
| G91LG8U: | |
| 540BCOD: | |
| 1518: | |
| LOM Blank: | |
| 540BDOW: | |
| 1514: | |
| Additional Network Cards: | |
| G18GDMK: | |
| 540BBUI: | |
| 1514_2: | |
| PERC H965e Adapter Low Profile DIB: | |
| GR72T9P: | |
| 405BBBV: | |
| 1519: | |
| No Cables Required No GPU Blanks: | |
| G0PNZWL: | |
| 470AEYU: | |
| 1624: | |
| Bezel: | |
| PowerEdge 2U LCD Bezel: | |
| 1532: | |
| BOSS Blank: | |
| G74DI3A: | |
| 329BERC: | |
| 1696: | |
| Quick Sync: | |
| No Quick Syn: | |
| 350BBYX: | |
| 1695: | |
| Password: | |
| 379BETE: | |
| 1693: | |
| 379BCQX: | |
| 1691: | |
| Group Manager: | |
| iDRAC Group Manager Disable: | |
| 379BCQY: | |
| 1692: | |
| Operating System: | |
| No Operating System: | |
| 611BBBF: | |
| 1650: | |
| OS Media Kits: | |
| No Media Required: | |
| 605BBFN: | |
| 1652: | |
| Rack Rails: | |
| 1610: | |
| Server Accessories: | |
| Fan Foam HDD 2U: | |
| 750ACOM: | |
| 1630: | |
| 631AACK: | |
| 1590: | |
| SHIPPING: | |
| PowerEdge R760 Shipping: | |
| 340DCEP: | |
| 1500: | |
| Shipping Material: | |
| PowerEdge R760 Shipping Material: | |
| 340DJQY: | |
| 1690: | |
| Regulatory: | |
| 343BBSU: | |
| 1507: | |
| ECCN: | |
| Decline Selection: | |
| 817BBBP: | |
| 1705: | |
| Service: | |
| 5 Years Pro support Next Business Day Onsite Service: | |
| GSTCP87: | |
| 29: | |
| 8416043: | |
| 345: | |
| AC Power Recovery On: | |
| ACON: | |
| 3660192: | |
| 200424: | |
| 3660193: | |
| 200424_2: | |
| User Accessible USB Ports All Ports On: | |
| 3660201: | |
| 200424_3: | |
| Manufacturer Part DLRT5KRMXLT: | |
| Dell Part A8572199: | |
| Catalog Number 16 A8572199: | |
| Manufacturer Part AP9567: | |
| Dell Part A7541364: | |
| Catalog Number 16 A7541364: | |
| SKU A7541364: | |
| Manufacturer Part A253PL256S4000F: | |
| Dell Part AA900597: | |
| AA900597: | |
| Manufacturer Part SRCOOL33K: | |
| Dell Part A7836420: | |
| Catalog Number 16 A7836420: | |
| SKU A7836420: | |
| 2024-03-25T12:43:43-0500 | |
| Dustin S. Baca -S |
File details come from the government source that posted it. Updated .