The document is a detailed specification for maintenance and repair services for electrical power generators, issued by the City of Newark, New Jersey. The City seeks to contract with a professional mechanic/machine repairman to maintain and repair both stationary and vehicle-mounted electrical power generators across various municipal locations on an as-needed and emergency basis. The contract covers generators ranging in size from 12.5 KVA to 410 KVA, with both gas and diesel types, located at 19 different public buildings and water department facilities. While a specific bid deadline of August 17, 2023, at 10:15 am is mentioned in the associated contract opportunity description, the specifications provide comprehensive details about inspection requirements, service expectations, and maintenance protocols.
The specifications outline specific pricing and service terms, including that the contractor must provide all necessary manpower, tools, equipment, and parts to maintain generators to full operational use. New parts must be new, unused, and meet ASTM, ANSI, and SAE approvals. The City will pay the net price for parts based on a manufacturer's price catalog, and the contractor must submit detailed invoices and service work orders. Emergency response is required within 15 minutes by telephone and on-site within four hours. The contract includes extensive maintenance schedules covering multiple system inspections, including starting systems, battery charging, fuel systems, cooling systems, and safety systems. Warranties are specified as 90 days for new parts and one year for electrical parts, with the City reserving the right to make multiple contract awards based on lowest cost.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPECIFICATIONS
926-61 Maintenance and Repair: Electrical Power Generators (Stationary and Mounted)
1.0 SCOPE/INTENT
The City of Newark intends to enter into an agreement with a professional Mechanic/Machine
Repairman to maintain and repair both stationary and vehicle-mounted electrical power generators at various locations within the City on an as-needed and on emergency basis.
2.0 PERFORMANCE REQUIREMENTS
2.0-1 Inspection of Equipment
An initial inspection shall be made and subsequent inspection on a four (4) month interval. All generators will be inspected to determine the performance capability.
The contractor shall submit a written estimate to the Agency Representative detailing the required work and parts needed to bring all equipment to full operational use.
2.0-2 Equipment Types
Makes (See 7.0 Emergency Generators on Page 7)
Type: Gas or Diesel
Size: 12 ½ KVA- 410 KVA
2.0-3 Services
The contractor shall provide the appropriate manpower, all tools, equipment and parts necessary to maintain all equipment to full operational use.
2.3.1 The contractor agrees to provide maintenance and repair services for the labor cost quoted herein this proposal for the duration of this agreement.
2.3.2 The contractor agrees to provide emergency services on 4 hours’ notice.
2.3.3 The contractor shall investigate and report to the Agency Representative and the Division of Central Purchasing any complaints that may arise regarding his performance.
2.0-4 Method
The contractor shall perform all work in accordance with standard trade practices, and he shall use only tools and parts that are fit for the function and purpose they are intended for.
2.4.1 All work is to be performed in a diligent and uninterrupted manner.
2.4.2 Upon completion of each job, the contractor shall clean up, and dispose of all discarded waste.
2.4.3 The contractor agrees that services to be provided under this agreement shall only be provided upon presentation of a written requisition for such services, authorized by the Director or the authorized designee. The City shall bear no obligation to make payment for any services provided by the contractor without the authorized documents.
2.4.4 The contractor agrees to provide the City with a complete written invoice for all services rendered.
2.0-5 Parts
All new parts must be new, unused and must be ASTM, ANSI, and SAE approved.
2.5.1 The City will pay to the contractor the net price on all parts utilized, vendor shall provide the Manufacturers Price Catalog at the time of contract execution.
2.5.2 All new parts are subject to approval by the Agency Representative and all old parts are to be turned over to the Agency Representative unless instructed otherwise.
2.5.3 All new parts utilized and amount of lubricants supplied must be itemized on the vendor’s invoice for payment.
2.5.4 Contractor shall submit price proposal each time additional parts as needed for repair and replacement and get approved before work commences. In case of an emergency situation, verbal approval is sufficient.
3.0-1 Responsibilities
It shall be the responsibility of the contractor to comply with all licensing requirement and all Federal, State, and Local laws. The contractor shall ensure all safety precautions are taken at all times to protect his employees, work tools, equipment, City employees and general public from any unfortunate mishap while performing this service.
3.0 REPAIR SCHEDULES---STATIONARY GENERATORS
3.0-1 General
1. Inspect engine for leaks or deterioration
2. Make note of any unusual sounds during walk around inspection
3. Check and adjust voltage and frequency
4. During load test, record the reading of the following:
a. Lube and oil pressure
b. Water temperature
c. Frequency
d. Current (all three phases)
e. Voltage (all three phases)
f. Kilowatts
5. Check engine and generator mounts
6. Remove oil and debris from engine exterior with approved solvent
3.0-2 Starting System
a. Clean batteries and cables
b. Check and record specific gravity is batteries are lead-acid or cell voltage readings if batteries are nickel cadmium
c. Check for proper starter operation noting any unusual noises
d. Check for proper cranking motor disconnect
e. Load test the battery set
3.0-3 Battery Charging System
a. Check battery trickle charger for proper operation
b. Check battery charging alternator for proper output
c. Tighten all battery connections
d. Check electrolyte level and fill
3.0-4 Fuel System
a. Check engine and supply system for any fuel leaks
b. Check operation of day tank pump and float switch
c. Check electrical and piping connections to day tank
d. Check fuel pressure gauge for proper pressure
e. Drain condensation from the bottom of day tank
f. Take sample of diesel fuel for analysis (one per year)
3.0-5 Lube Oil System
a. Check oil level
b. Check engine oil pressure
c. Check oil filter differential pressure, if applicable
d. Take sample of lube oil for analysis (one per year)
3.0-6 Air Intake System
a. Check clean air condition
b. Check turbo-charger for excessive end play
c. Listen for any unusual noises from this area
d. Check air intake louvers for proper operation
e. Ensure that the air intake flow is not unduly restricted
3.0-7 Exhaust System
a. Inspect exhaust silencer, flexible connection and exhaust piping
b. Visually check exhaust outlet for excessive smoking
c. Visually check crankcase breather for excessive smoking
3.0-8 Cooling System
a. Check coolant level
b. Check for proper amount of antifreeze
c. Check radiator core for obstruction or buildup of foreign material
d. Check general condition of engine coolant
e. Check all belts for weather and proper tension
f. Check all hoses for cracks and brittleness
g. Check jacket water heaters and thermostats for proper operation
3.0-9 Speed Control System
a. Check governor rods and linkages for loose or worn parts
b. Check governor operation under load
c. Tighten loose wiring connections and note any potential problems
d. Check UG8 governor oil
3.0-10 Safety System
a. Test over speed device
b. Test water temperature contractor
c. Test lube oil pressure contactor
d. Test over crank device
e. Check out all other safety devices, which may cause damage to the engine
3.0-11 AC Power Generator
a. Make a general inspection of all electrical connections on regulator and generator
b. Inspect generator brushes and slip rings, if applicable
c. Grease bearings, if necessary
d. Check and adjust voltage regulator
e. Vacuum dust from generator compartment
3.0-12 Engine Control Panel
a. Inspect all electrical connection and tighten where necessary
b. Inspect condition of relay contacts
c. Thoroughly clean control panel
d. Replace any indicator lights not working
e. Replace any blown fuses
f. Check operation of main circuit breaker and leave in “Ready” position
3.0-13 Engine Service
a. One complete engine service to include oil, oil filters, fuel filters ad air filter (air filters when needed), waste oil removal and labor. This work is to be performed during the first quarter.
b. Antifreeze will be billed separately as needed.
3.0-14 Repair Services: As Needed
a. In addition to the preventive maintenance, the contractor shall provide repair services as needed to bring all generators to full operational use.
b. All repair work must be approved by the Agency Representative.
c. The contractor shall prepare a written report for anything found broken, leaking or in need of further repair, and shall submit a written estimate for all repair work to the Agency Representative, before commencement of any repair work.
3.0-15 Emergency Response and Repair Services: WHEN NEEDED
A. Must provide telephone response within fifteen (15) minutes of receiving an
“EMERGENCY SERVICE CALL”
B. Must be on site ASAP or within four (4) hours depending on the customer needs
3.0-16 Repair Services: Vehicle-Mounted Generators
The City also operates certain generator equipment mounted on its trucks as specified below:
Make – Onan
Type – Emerald Plus 6500
Model – 6.5 NHE-FA/26100
Make – Honeywell
Type – DA 12L
Make – FABCO
Type – 6 KW
Make – Generac
Type – 6600 Watts
4.0 WARRANTY/ GUARANTEE
All new parts must be guaranteed for at least ninety days, all electrical parts for one (1) year.
The contractor shall correct any work and replace any part ascertained by the City to be flawed in workmanship and/or material makeup
5.0 PAYMENTS
In addition to the contractor’s invoice for payment of services rendered, he must comply and provide the City with the following:
a. Upon arrival at each City facility, the contractor shall immediately report to the
Agency Representative or his authorized designee before commencing with any work.
b. Upon completion of all work at each City facility, the contractor shall report back to the Agency Representative or his authorized designee to verify all tasks were performed and completed.
c. The contractor must present his company Service Work Order to the Agency
Representative for an authorized signature. Such Service Work Order shall detail all tasks completed, and all parts and lubricants utilized. It must also indicate the start and completion times, total number of labor hours rendered and be signed by the contractor or his employee.
d. A carbon copies of the Service Work Order specified herein must be submitted to the Agency Representative at each City facility by the contractor or his employee on the same day that such services were rendered, upon completion of all tasks.
e. A carbon copy of the Service Work Order specified herein must be presented along with the contractor’s invoice for payment of all services provided at each
City facility.
f. The City shall pay to the contractor the net price on all parts utilized and the actual amount of lubricants supplied, as shown in the manufacturer’s price catalog.
g. The contractor shall be paid for the actual service and/or repair time at the City facility. No travel time or mileage cost will be paid.
5.0 PRICING
All prices quoted on the Pricing Proposal sheet shall remain firm for the duration of the contract. The prices must include all of the contractor’s costs (labor, transportation, materials and supplies, shipping and handling, etc.) necessary to provide the services specified herein. Any additional expenses incurred by the contractor that are not reflected on the Pricing Proposal Sheet will be rejected by the City.
6.0 MULTIPLE CONTRACT AWARDS
The City reserves the right to make multiple awards to meet the needs of the City for this particularized service. If and where multiple awards are made, the contracts shall be awarded and the vendors utilized based on the lowest cost to the City.
7.0 EMERGENCY GENERATORS
Public Buildings
Location Make Model/ Serial # Size Type
Age/
Years
1. Police Headquarters
22 Franklin Street
Int’l Harvester V 401 93138 50KVA GAS 19
2. North District
One Lincoln Avenue
Onan 45.0/DM-15R/9164 45KVA GAS 19
3. 255 Century Avenue Gillete
Generators
SP-620-3-2NE(LE) 55KVA GAS n/a
4. East District
649 Market Street
Onan 12.5JC/4R/183905 12.5KV GAS 19
5. West District
10 17th Avenue
Onan 15JC4R/6644R 15KVA GAS 19
6. Health & Human Services
110 William Street
Sateline 427477 135KVA DIESAL 1
7. Police Cell Block
31 Green Street
Onan 75.00DYC15R12425/
A760995341
63KVA DIESAL 10
8. Record Bureau
City Hall Annex-Basement
Kohler VG404397505 18KVA GAS 19
9. 191 Orange Street Kohler 45RZ82 56.25KVA GAS 7
10. Fire Headquarters
1010 18th Avenue
Onan 15JC4R6644R 15KVA GAS 19
11. North District-Parking Lot
1 Lincoln Avenue
Onan 80DGOA 1930521013 100KVA DIESAL 3-4
12. Police & Courts Complex
31 Green Street
Onan 200:DDFP-17R/16549H-
A760995377
250 KVA DIESAL 10
13. City Hall Sub-Basement
920 Broad Street
Generac 97A07572-S 2039320 56.2KVA GAS 4
14. Public Safety Complex
311 Washington Street
Kohler
Detroit
Diesel
Series 60 410KVA DIESAL 6
15. Fire Complex
360 Clinton Avenue
Generac
Series
1625540100-263609 375 KVA DIESAL 4
16. Police
472 Orange Street
Onan 15.1CO4R/
6644R 0568030920
18.75KV GAS n/a
17. Newark Street Gas Pump
Magna Plus 361PS S 11611 DIESEL n/a
18. 62 Frelinghuysen Avenue Generac Double
Wall
300I65106 60KVA DISESEL n/a
19. 227 West Market Street Kohler 20RES 18KVA GAS n/a
Water Department
20. 202-226 Rome Street Gillette SP-620-3-4NO (LO) 55KVA GAS n/a
21. 704-738 Doremus Avenue Cummins
Powell
DGHBD-1341959 75KVA DIESEL n/a
22. 714-716 Mount Prospect Gillette Sentry
Pro
SP200 20KVA GAS n/a
23 55 Ludlow Street General Joe TG250 313KVA GAS n/a
Location Make Model Serial # KW
1. PWTP-2224
RT 23 North
West Milford, NJ 07840
Caterpillar D398 66B09569 500
2. PWTP-2224
RT 23 North
West Milford, NJ 07840
Caterpillar D398 66B09541 500
3. PWTP-2224
RT 23 North
West Milford, NJ 07840
Caterpillar 3208 302A02854 175
4. PWTP-2224
RT 23 North
West Milford, NJ 07840
Perkins AB35049 U899267D 75
5. PWTP-2224
RT 23 North
West Milford, NJ 07840
Screen Building
John Deere 402HF285 PE4024L099160 50
6. PWTP-2224
RT 23 North
West Milford, NJ 07840
Charlottesburg Dam
John Deere 6059TF CD6059T249183 100
7. PWTP-2224
RT 23 North
West Milford, NJ 07840
Portable
Briggs &
Stratton
8. PWTP-2224
RT 23 North
West Milford, NJ 07840
Portable
Dayton
9. PWTP-2224
RT 23 North
West Milford, NJ 07840
Pre-Treat
Generac SD-35 35KW
10. Montclair
782 Valley Road
Montclair, NJ 07043
Generac 90A01623-s 73398 240
11. Little Falls- Portable
1294 McBride Avenue
Little Falls, NJ 07043
Dayton 09156-0
12. Wayne Pump Station
592 Newark-Pompton
Turnpike
Wayne, NJ
Dayton 3512C LYH00202 1500
13. 127 Clay St.
Newark, NJ 07104
Cummins Power GGPA-
1327959
E 130507726 23.5 KW
14. 966-968 Rector Street
Route 21- Gatehouse
Newark, NJ 07104
Cummins Power GGFD-
5569306
J020418799 23.5 KW
15. 00 Herbert Pl.
Newark, NJ 07104
Cummins Power GGMA-
7254513
J080214028 20KW
The City reserves the option to add additional sites under the same terms and conditions as stated herein.
16. 18-29 Verona Ave.
Newark, NJ 07104
Cummins Power GGFD-
7794495
D090241926 23.5 KW