This is a specification sheet for Prysmian Group's Dry FusionLink Armored Ribbon Central Tube (Dry) Cable in support of the City of Palo Alto's Request for Quotes Number 198238 for the purchase and delivery of 432 fiber optic cable. The City of Palo Alto's Electric Operations Department, Utilities Division is seeking to procure fiber optic cable meeting or exceeding the specifications detailed in the specification sheet. The RFQ specifically addresses a one-time purchase of 432 fiber optic cable. The specification sheet describes cable configurations available in both coupled (RCD) and uncoupled (RCU) designs, with fiber counts ranging from 12 to 864 fibers. The coupled design (RCD1A1J-24-AA-432-BB) applicable to this procurement consists of 432 fibers arranged in 24-fiber ribbons with 13 to 18 ribbons per cable, eliminating the need for splice point coupling coils in aerial applications. The cable features dry water-blocking technology, corrugated steel armor for mechanical protection, and flexible buffer tubing for superior kink resistance and route management in closures.

The specification sheet indicates that the Prysmian cable meets or exceeds requirements of Telcordia GR-20 and ICEA 640 standards and complies with RUS PE-90 specifications. Performance parameters include a dynamic bend radius of 20 times cable outer diameter and static bend radius of 10 times cable outer diameter, with tensile ratings of 2,700 Newtons (600 lbf) for installation and 800 Newtons (180 lbf) residual. The cable operates across temperature ranges from -40 to +70 degrees Celsius and is available with various single-mode fiber types including ITU G.652 C & D low water peak (HB designation) and bend-insensitive options. The RCD1A1J-24-AA-432-BB configuration specified has a cable outer diameter of 0.90 inches (22.5 millimeters) and approximate weight of 262 pounds per thousand feet (391 kilograms per kilometer). The City of Palo Alto's RFQ indicates acceptance of alternate manufacturer proposals, provided that data sheets for proposed alternates are submitted with the quote.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Dry FusionLink™ Armored Ribbon Central Tube (Dry) Cable

Prysmian Group 4 Tesseneer Drive, Highland Heights, KY 41076 +1-859-572-8000 / na.prysmiangroup.com

TLS-DS-A-204-0621

FEATURES AND BENEFITS

Compact Design

• Efficient packaging of higher fiber counts

• Lightweight and easy to handle during installation

Easily Removable Ribbon Matrix

• Allows for ease of stripping and fiber breakout

• Improves mid-span strippability

Precision Ribbon Geometry

• Time and labor savings during fiber splicing

Flexible Buffer Tubet

• Superior kink resistance

• Increased flexibility

• Facilitates route management in closures

Dry Water-Blocking Technology

• Buffer tube and core are completely dry – no gel

• Permits rapid cable preparation and termination

• Water-blocking materials are easily removede ezPrep® Corrugated Steel Armor

• Provides additional mechanical protection

• Special coating reduces time and effort to remove jacket

Available Uncoupled or Coupled Designs

• Coupled design (RCD product) couples the ribbon stack with the cable which elimates the need for splice point coupling coils in aerial application

• Un-coupled design (RCU product) requires the use of coupling coils at the splice points in aerial applications to prevent fiber retraction in closures

RUS

LISTED

PERFORMANCE SPECIFICATIONS

Bend Radius Dynamic 20 x Cable OD Static (Single Bend) 10 x Cable OD Static (Cable Coil) 15 x Cable OD

Tensile Rating N lbf Installation 2,700 600

Residual 800 180

Crush Resistance N/cm lbf/in Short/ long Term 220/110 125/63

Temperature Ratings °C °F

Operation -40 to +70 -40 to +158 Installation -30 to +60 -22 to +140 Storage/Shipping -40 to +75 -40 to +167

Performance

• Meets or exceeds the requirements of Telcordia GR-20 & ICEA

640 and is tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables

• Tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables

• Complies with RUS PE-90

Registered Supplier

• ISO 9001, ISO 14001, TL 9000, and OHSAS 18001

Ribbon Stack

Water-Blocking Tape (In tube)

Water Blocking Tape

MDPE Outer Jacket

Ripcord

Dry Water-Blocked Buffer Tube

Fiber Count Range

Recommended Fiber Count

Recommended Prysmian** Part Number

Fibers / Ribbon

Number of Ribbons

Aerial Coupling

Coils Required

Buffer Tube OD Cable OD Approx. Cable Weight Max. Reel Length

Inches mm Inches mm lb/kft kg/km feet meters

RCU1A1J

12 – 48

12 RCU1A1J-12-AA-012-BB

12 1 – 4 Yes 0.24 6.2 0.50 12.5 102 152 36,693 11,18724 RCU1A1J-12-AA-024-BB

48 RCU1A1J-12-AA-048-BB

456 – 576* 576 RCU1A1J-24-AA-576-BB 24 24 Yes 0.78 19.8 1.09 27.8 358 533 16,275 4,960

RCD1A1J

60 – 72 72 RCD1A1J-12-AA-072-BB 12 5 – 6 No 0.35 8.8 0.64 16.3 151 224 36,693 11,187

84 – 96 96 RCD1A1J-12-AA-096-BB 12 7 – 8 No 0.37 9.5 0.67 17.0 157 233 33,111 10,095

108 – 144 144 RCD1A1J-12-AA-144-BB 12 9 – 12 No 0.42 10.6 0.71 18.1 173 258 29,126 8,880

156 – 216 216 RCD1A1J-12-AA-216-BB 12 13 – 18 No 0.48 12.3 0.78 19.8 192 285 24,862 7,580

240 – 288* 288 RCD1A1J-24-AA-288-BB 24 10 – 12 No 0.56 14.3 0.84 21.4 245 364 17,864 5,445

312 – 432* 432 RCD1A1J-24-AA-432-BB 24 13 – 18 No 0.61 15.4 0.90 22.5 262 391 17,864 5,445

612 – 864* 864 RCD1A1J-36-AA-864-E1 36 17 – 24 No 0.78 19.8 1.09 27.8 358 533 10,718 3,267

Prysmian Group 4 Tesseneer Drive, Highland Heights, KY 41076 +1-859-572-8000 / na.prysmiangroup.com

TLS-DS-A-204-06212

**Where AA equals glass type and BB equals attenuation code

* Note: This design uses 24 fiber ribbons for counts of 240 to 576 fibers and 36 fiber ribbons for 612 to 864 fibers.

Please refer to ribbon in loose tube designs for higher fiber counts using 12 fiber ribbons.

If on reel testing is required for the 612-864 fiber designs, a reel with 60” drum must be specified on the order.

Prysmian Group 4 Tesseneer Drive, Highland Heights, KY 41076 +1-859-572-8000 / na.prysmiangroup.com

TLS-DS-A-204-0621

Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance.

The appropriate part number can be configured using the process described below

PART NUMBER CONSTRUCTION

1 LENGTH MARKINGS

F = Feet or M = Meters

2 PRODUCT FAMILY

RCD = Dry FusionLink™ Coupled Design (60 to 432, 612 to 864)

RCU = Dry FusionLink™ Uncoupled Design (12 to 48, 576):

aerial coupling coils required

3 CONSTRUCTION

1A1J = Single Armor, Single Jacket

4 FIBER GROUPING

12 = 12f per tube

24 = 24f Ribbons

36 = 36f Ribbons

Note: Please refer to the Fiber Code Addendum for additional fiber options, or contact us for help.

Other cable constructions and fiber performance grades available on request.

FIBER INFORMATION

5 FIBER TYPE

SINGLE-MODE

HB = Single-Mode (ITU G.652 C & D) Low Water Peak

ES = Enhanced Single-Mode (ITU G.652 C & D)

CE = Corning™ SMF28e+ Single-Mode

B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)

BB = BendBright™ Single-Mode (ITU G.657.A1 & G.652.D)

BU = Bend-Insensitive Single-Mode (ITU G.657.A1+ & G.652.D)

DB = BendBright A1+ Single-Mode (ITU G.657.A1+ & G.652.D)

CU = Corning™ SMF-28® Ultra Single-Mode (ITU G.657.A1 & G.652.D)

B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & G.652.D)

BX = BendBrightXS™ Single-Mode (ITU G.657.A2 & .B2 & G.652.D)

6 FIBER COUNT

12 to 864 fibers

7 FIBER GRADE

SINGLE-MODE

Attenuation (dB/km) Wavelength (nm)

E1 = 0.40/0.40/0.30 1310/1383/1550

* E3 = 0.35/0.35/0.25 1310/1383/1550

* 612 to 864 fibers limited to E1 attenuation code

Example: 96 count Dry FusionLinkTM Armored with G.652.D LWP single-mode fiber and 0.40/0.40/0.30 attenuation with coupling (printed in feet)

1 LENGTH

MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER

GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE

F – RCD 1A1J – 12 – HB – 096 – E1

1. RCD Coupled Design Example (for 60 to 432, 612 to 864):

Example: 48 count Dry FusionLinkTM Armored with G.652.D LWP single-mode fiber and 0.40/0.40/0.30 attenuation without coupling (printed in feet)

1 LENGTH

MARKINGS 2 PRODUCT

FAMILY 3 CONSTRUCTION 4 FIBER

GROUPING 5 FIBER TYPE 6 FIBER COUNT 7 FIBER GRADE

F – RCU 1A1J – 12 – HB – 048 – E1

2. RCU Uncoupled Design Example (for 12 to 48, 576):