This document is a diesel fuel specification (SFD) for the Defense Logistics Agency (DLA) Energy in Europe, the Middle East, and Afghanistan. The specification details the requirements for the diesel fuel, including compliance with the EN 590 standard, maximum sulfur content, and additional testing requirements for deliveries to Kosovo and Afghanistan. It also outlines the process for submitting written exceptions or deviations if the contractor is unable to meet any of the specification requirements.
The related federal contract opportunity is for the delivery of 48,000 gallons of diesel fuel (SFD) to Jasionka, Poland over six delivery dates in August 2024. The contract will be awarded using the Simplified Acquisition Procedures (FAR Part 13) under NAICS code 324110, on a firm fixed-price basis. The solicitation is a Request for Quote (RFQ), and all quotes must be submitted by August 2, 2024. The award will be made based on the Lowest Price Technically Available (LPTA) evaluation criteria.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEFENSE LOGISTICS AGENCY ENERGY Page 1 of 1
8725 JOHN J. KINGMAN ROAD
FORT BELVOIR, VIRGINIA 22060-6222
Signature
Prepared by:
Quality/Technical Support Office Approval
Contracting Approval:
DISTRIBUTION STATEMENT – A: APPROVED FOR PUBLIC RELEASE. DISTRIBUTION IS UNLIMITED
C16.67-2 DIESEL FUEL SPECIFICATION (SFD) (PC&S) (EUROPE) (MIDDLE EAST) (DLA ENERGY NOV 2018)
NATIONAL STOCK NUMBER PRODUCT NOMENCLATURE DLA ENERGY PRODUCT CODE
9140-01-556-9156 Diesel Fuel SFD
Supplies delivered under this contract shall conform to all National environmental requirements applicable to the geographic location of the receiving activity on the date of delivery. The list of such requirements contained in this contract is not intended to be a complete list and the Contractor shall be responsible for determining the existence of all such requirements. In the event that a National environmental requirement is more stringent than a specification contained in this contract, the Contractor shall deliver product that complies with the more stringent requirement. Product that fails to meet the more stringent requirement will be considered a nonconforming supply. Product(s) supplied shall fully meet the requirements of the applicable specification(s) as cited below.
Product shall conform to the latest revision of commercial specification EN 590. Product shall be visually free of undissolved water, sediment, and suspended matter. Product classification is shown above. Maximum sulfur content, as stated in EN 590, is 10 mg/kg (0.0010 wt%).
a) FOR LOCATIONS IN KOSOVO:
(1) TESTING REQUIREMENTS: The following additional tests shall be performed and results reported:
i. Color: ISO 2049/ASTM D1500
ii. Acid Number: ISO 6618/ASTM D974
(2) In addition to the EN 590 specification requirement for water content of 200 mg/kg or ppm (0.0200 wt%) maximum, and particulate content of 24 mg/kg or ppm (0.0024 wt%) maximum, the diesel fuel shall have a maximum haze rating of 2 when tested in accordance with ASTM D4176, Procedure 2. In case of dispute, the haze rating shall be determined at 25 °C (77 °F) with a maximum haze rating of 2 and shall contain no more than 24 mg/kg (0.0024 wt%) sediment and no more than 200 mg/kg (0.0200 wt%) water.
(3) Diesel during the summer months, May 1st to September 30th, shall comply with Grade A of Table 2 in EN 590.
(4) Diesel during winter months, October 1 to April 30th, shall comply with the Class 1 limits set in Table 3 of EN 590.
b) FOR LOCATIONS IN AFGHANISTAN: Diesel fuel delivered to all locations in Afghanistan shall meet the Grade E, -
15°C maximum cold filter plugging point, as detailed in EN 590 Section 5.6.1, Table 2 – Climate Related Requirements and Test Methods – Temperate Climates.
c) FOR ALL LOCATIONS: Written exception(s) or deviation(s) must be submitted to DLA Energy contracting officer if the Contractor is unable to meet any of the characteristic requirements of the above listed specification(s). Exception(s) and/or deviation(s) must state the reason why the contractor is unable to meet requirements, if this will be for the entirety of the performance period, if it is source specific, the Contractor’s course of action on how they plan on resolving this issue, and any proposed changes to specification requirement limit(s) for that product.
| 2018-11-16T10:10:12-0500 | |
| ATKINS.RENRICK.L.1024389320 |
| 2018-11-16T10:25:11-0500 | |
| BANISZEWSKI.DANIEL.J.1287388698 |
| 2018-11-16T21:11:17-0500 | |
| PETERSON.DAVID.W.1074069483 |
File details come from the government source that posted it. Updated .