This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart
12.6 & 13.5 of the Federal Acquisition Regulations (FAR), as supplemented with additional information included in Federal Acquisition Circular 2005-95 dated June 05 2019. The clauses and provisions referenced in this solicitation may be reviewed/obtained in full text form at http://farsite.hill.af.mil/vffara.htm.
Quotes are being requested and a written solicitation will not be issued. The award resulting from this procurement will be firm fixed price. The solicitation SPE60519Q0250 is issued as a Request for Quotation (RFQ). The clauses and provisions referenced in this solicitation may be reviewed/obtained in full text form at http://farsite.hill.af.mil/vffara.htm.
Scope of Contract:
Acquisition type: Unrestricted
SCHEDULE B:
The following pieces of laboratory equipment are required in support of testing/analyzing petroleum product lubricant oil. This is not being solicited on an “all or none basis" for the equipment listed below and the quoted price is all-inclusive. Quotations can be submitted on individual line items.
CLIN 0001:
Nomenclature: Density Meter, Benchtop
QTY: 0001 U/I: EA
UNIT PRICE $_________
EXTENDED PRICE: $____________________
DELIVERY DATE:_______________
Description:
Instrument shall adhere to ASTM D4052, Standard Test Method for Density.
• MU/I: EAsure reliable and accurate 4 digit density values within 0.0001 g/cm3 and temperature range from 0-100 degrees C.
• Instrument must include API functions in settings.
• Shall utilize either 110/115 volts or 220/230/240 volts 50/60Hz with United States style electrical plugs.
to match building voltage..
• Depth must be equal to or less than 30" to accommodate benchtop available space. Height and width is unrestricted.
• The equipment shall include a one-yU/I: EAr warranty.
• All instrument documentation must be provided via either email or on a CD/DVD.
This is a brand name or equal requirement (Reference FAR 52.211-6) Reference Anton Paar, Model: DMA- 4100M
SHIP TO:
FLC San Diego Petroleum Laboratory http://farsite.hill.af.mil/vffara.htm
199 Rosecrans St Bldg 70A Point Loma Annex San Diego, CA 92106
CLIN 0001AA
Nomenclature: Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0001.
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $______________
DELIVERY DATE:_______________
CLIN 0002:
Nomenclature: Existent Gum Bath, Jet Fuel
QTY: 0001 U/I: EA
UNIT PRICE $_________
EXTENDED PRICE: $____________________
DELIVERY DATE:_______________
Description: Shall adhere to ASTM D381, Gum Content in Fuels by Jet Evaporation
• Initial on-site installation/calibration/hands-on demonstration within two weeks of the equipment arrival.
• The equipment shall include a one-yU/I: EAr warranty.
• Four bath unit with stU/I: EAm and air evaporation capability.
• Electrical requirements: must meet the voltage requirement of either 115 or 220 volts 60Hz with US style electrical.
• Must have a pressure regulator and an air flowmeter built-in as a single unit.
• Dimensions must not exceed: 39” x 27” x 30” to accommodate benchtop space.
• All instrument documentation (if provided electronically) must be provided via either email or on a
CD/DVD.
This is a brand name or equal requirement (Reference FAR 52.211-6): MFG: Koehler Instruments, Model:
K33800.
SHIP TO:
FLC San Diego Petroleum Laboratory 199 Rosecrans St Bldg 70A Point Loma Annex San Diego, CA 92106
CLIN 0002AA:
Nomenclature: INSTALLATION, CALIBRATION & ONSITE DEMONSTRATION FOR CLIN 0002
(WITHIN TWO WEEKS OF ARRIVAL OF CLIN 0002)
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $______________
DELIVERY DATE:_______________
CLIN 0002AB
Nomenclature: Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0002.
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $______________
DELIVERY DATE:_______________
CLIN 0003:
Nomenclature: Centrifuge
QTY: 0001 U/I: EA
UNIT PRICE $_________
EXTENDED PRICE: $____________________
DELIVERY DATE:_______________
Description:
Instrument shall adhere to ASTM D893 provide a convenient mU/I: EAns of determining sediment and water content in crude oil, fuel oils, middle distillate fuels, and biodiesel.
The equipment shall include a one-yU/I: EAr warranty.
Initial on-site installation/calibration/hands-on demonstration within two weeks of the equipment arrival.
Must have capacity for Four (4) oil test centrifuge tubes: long (100mL), short (100mL), pU/I: EAr (100mL), or finger tubes (12.5mL) Must accommodate 115V 60 Hz, 7A 230V 50/60 Hz, 3.5A power supply with US-style plug All instrument documentation (if provided electronically) must be provided via either email or on a CD/DVD Dimensions must be no grU/I: EAter than 36x29x20 in. (91.4x73.7x50.8 cm) and weight of 125 lbs (56.7 kg
This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG: Koehler, Centrifuge
SHIP TO:
FLC Jacksonville FL Code 700, Fuel Dept.
8808 Somers Road, Bldg. 56 Jacksonville, FL 32226-2600
CLIN 0003AA:
Nomenclature: INSTALLATION, CALIBRATION & ONSITE DEMONSTRATION FOR CLIN 0003
(WITHIN TWO WEEKS OF ARRIVAL OF CLIN 0003)
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $____________
DELIVERY DATE:_______________
CLIN 0003AB
Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0003.
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $______________
DELIVERY DATE:_______________
CLIN 0004:
Nomenclature: Emulsion Analyzer
QTY: 0001 U/I: EA
UNIT PRICE $_________
EXTENDED PRICE: $____________________
DELIVERY DATE:_______________
Description: Instrument shall adhere to ASTM D1401, Method for Water Separability of Petroleum Oils
• Initial on-site installation/calibration/hands-on demonstration within two weeks of the equipment arrival.
• The equipment shall include a one-yU/I: EAr warranty.
• All instrument documentation (if provided electronically) must be provided via either email or on a
CD/DVD.
• Weight shall not exceed 75 lbs.
• Test positions shall accommodate 8.
• Automatic timer stop with audible alarm from 1 to 10,000 s.
• Bath capacity shall accommodate maximum of 30 liters.
• Safety fU/I: EAtures included are: low level protection, safety cut-off stirrer lift.
• Stainless steel stirrer paddle. No copper.
• Electrical requirements shall accommodate 230 V, 50 Hz/60 Hz, 2100 W or 115 V, 50 Hz/60 Hz, 1600
W
• Dimensions must be no grU/I: EAter than 440 mm x 440 mm x 700 mm (W x D x H)
This is a brand name or equal requirement (Reference FAR 52.211-6) MFG: Anton PAAR, Model: DH5
SHIP TO:
FLC Jacksonville FL
Code 700, Fuel Dept.
CLIN 0004AA:
Nomenclature: INSTALLATION, CALIBRATION & ONSITE DEMONSTRATION FOR CLIN 0004
(WITHIN TWO WEEKS OF ARRIVAL OF CLIN 0004)
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $____________
DELIVERY DATE:_______________
CLIN 0004AB
Nomenclature: Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0004.
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $______________
CLIN 0005:
Nomenclature: Microbalance
QTY: 0001 U/I: EA
UNIT PRICE $_________
EXTENDED PRICE: $____________________
DELIVERY DATE:_______________
Description: Instrument automatically detects static charges and warns you when your results are out of tolerance
• The equipment shall include a one-yU/I: EAr warranty.
• Must accommodate balance capacity of 26 grams with a rU/I: EAdability of 0.001 milligram (1 µg) to full capacity.
• Accommodate large color touchscreen display that is detachable from the main unit.
• Must accommodate 230/115/100 VAC, 50–60 Hz configurable/selectable power supply.
This is a brand name or equal requirement (Reference FAR 52.211-6) MFG: Mettler Toledo XPE26, Model:
Micro Balance.
SHIP TO:
FLC Jacksonville FL Code 700, Fuel Dept.
CLIN 0005AA
Nomenclature: Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0005.
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $______________
DELIVERY DATE:_______________
CLIN 0006:
Nomenclature: Microseparometer (MSEP)
QTY: 0001 U/I: EA
UNIT PRICE $_________
EXTENDED PRICE: $____________________
DELIVERY DATE:_______________
Description: Shall adhere to ASTM D3948, Determining Water Separation Characteristics.
• All instrument documentation (if provided electronically) must be provided via either email or on a
CD/DVD.
• The equipment shall include a one-yU/I: EAr warranty.
• Shall be portable and contain a rechargU/I: EAble battery.
• Shall include: clU/I: EAr glass vial, turbidimeter, a mechanical mixer, plastic syringe and disposable coalescer filter.
• Electrical requirements: must meet the voltage requirement of either 115 or 220 volts 60Hz with US style electrical.
• Weight shall not exceed 45 pounds.
This is a brand name or equal requirement (Reference FAR 52.211-6) MFG: Emcee, Model: 1140 Micro- Separometer.
SHIP TO:
NAVSUP FLC Rota Fuels Laboratory Building 55 Rota, Cadiz, Spain 11530
CLIN 0006AA
Nomenclature: Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0006.
QTY: 0001 U/I: EA
UNIT PRICE $__________________
CLIN 0007:
Nomenclature: Density Meter, Benchtop
QTY: 0001 U/I: EA
UNIT PRICE $_________
EXTENDED PRICE: $____________________
DELIVERY DATE:_______________
Description:
Instrument shall adhere to ASTM D4052, Standard Test Method for Density.
• MU/I: EAsure reliable and accurate 4 digit density values within 0.0001 g/cm3 and temperature range from 0-100 degrees C.
• Instrument must include API functions in settings.
• Can utilize 110 VAC/60Hz with US-style plug.
• Depth must be equal to or less than 30" to accommodate benchtop available space. Height and width is unrestricted.
• The equipment shall include a one-yU/I: EAr warranty.
• All instrument documentation (if provided electronically) must be provided via either email or on a
CD/DVD.
This is a brand name or equal requirement (Reference FAR 52.211-6) Reference Anton Paar, Model: DMA- 4100M
SHIP TO:
NAVSUP FLC Rota Fuels Laboratory building 55 Rota, Cadiz, Spain 11530
CLIN 0007AA
Nomenclature: Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0007.
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $______________
DELIVERY DATE:_______________
CLIN 0008:
Nomenclature: Ellipsometer, Jet Fuel Unit of Issue: U/I: EA
QTY: 0001
UNIT PRICE $_________
EXTENDED PRICE: $____________________
Description:
Instrument shall adhere to ASTM D3241, Standard Test Method for Thermal Oxidation Stability of Aviation Turbine Fuels, Annex A3 “Rating of D3241HU/I: EAter Tubes – Ellipsometric Method.”
• Shall mU/I: EAsure deposit thickness ranging 0 to 350nm.
• Shall utilize either 110/115 volts or 220/230/240 volts 50/60Hz with US style electrical plugs.
• Dimensions shall not exceed 12" x 16" x 14"
• Weight shall not exceed 17kg
• Shall conform to ASTM D3241 Annex 3.
• Shall use an optical detection system.
This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Falex, Model: 430
NAVY FUELS DEPT
690 SAN CARLOS RD
PENSACOLA, FL 32508
CLIN 0008AA:
INSTALLATION, CALIBRATION & ONSITE DEMONSTRATION FOR CLIN 0008
(WITHIN TWO WEEKS OF ARRIVAL OF CLIN 0008)
QTY: 1 U/I: EA
UNIT PRICE $__________________
CLIN 0008AB
Nomenclature: Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0008.
QTY: 0001 1 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $______________
DELIVERY DATE:_______________
CLIN 0009:
Nomenclature: Existent Gum Bath, Jet Fuel
QTY: 0001 U/I: EA
UNIT PRICE $_________
EXTENDED PRICE: $____________________
Description: Shall adhere to ASTM D381, Gum Content in Fuels by Jet Evaporation
• Initial on-site installation/calibration/hands-on demonstration within two weeks of the equipment arrival.
• Four bath unit with stU/I: EAm and air evaporation capability.
• Electrical requirements: must meet the voltage requirement of either 115 or 220 volts 60Hz with US style electrical plugs.
• Must have a pressure regulator and an air flowmeter built-in as a single unit.
• Dimensions must not exceed: 39” x 27” x 30” to accommodate benchtop space.
• All instrument documentation (if provided electronically) must be provided via either email or on a
CD/DVD.
This is a brand name or equal requirement (Reference FAR 52.211-6): MFG: Koehler Instruments, Model:
K33800.
NAVY FUELS DEPT
690 SAN CARLOS RD
PENSACOLA, FL 32508
CLIN 0009AA:
Nomenclature: INSTALLATION, CALIBRATION & ONSITE DEMONSTRATION FOR CLIN 0009
(WITHIN TWO WEEKS OF ARRIVAL OF CLIN 0009)
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $____________
DELIVERY DATE:_______________
CLIN 0009AB:
Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0009.
QTY: 1 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $______________
DELIVERY DATE:_______________
CLIN 0010:
Nomenclature: Emulsion Analyzer
QTY: 0001 U/I: EA
UNIT PRICE $_________
EXTENDED PRICE: $____________________
Description: Instrument shall adhere to ASTM D1401, Method for Water Separability of Petroleum Oils
• Initial on-site installation/calibration/hands-on demonstration within two weeks of the equipment arrival.
• All instrument documentation (if provided electronically) must be provided via either email or on a
CD/DVD.
• Weight shall not exceed 75 lbs.
• Test positions shall accommodate 8.
• Automatic timer stop with audible alarm from 1 to 10,000 s.
• Bath capacity shall accommodate maximum of 30 liters.
• Safety fU/I: EAtures included are: low level protection, safety cut-off stirrer lift.
• Stainless steel stirrer paddle. No copper.
• Electrical requirements shall accommodate 230 V, 50 Hz/60 Hz, 2100 W or 115 V, 50 Hz/60 Hz, 1600
DLA Energy Alaska Petroleum Laboratory BLDG 986 Warehouse Street JBER-Richardson, AK 99506
CLIN 0010AA:
Nomenclature: INSTALLATION, CALIBRATION & ONSITE DEMONSTRATION FOR CLIN 0010
(WITHIN TWO WEEKS OF ARRIVAL OF CLIN 0010)
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $____________
DELIVERY DATE:_______________
CLIN 0010AB:
Nomenclature: Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0010.
QTY: 0001 U/I: EA
UNIT PRICE $__________________
CLIN 0011:
Nomenclature: Density Meter, Benchtop
UNIT PRICE $_________
EXTENDED PRICE: $____________________
DELIVERY DATE:_______________
Description:
Instrument shall adhere to ASTM D4052, Standard Test Method for Density.
• MU/I: EAsure reliable and accurate 4 digit density values within 0.0001 g/cm3 and temperature range from 0-100 degrees C.
• Instrument must include API functions in settings.
• Can utilize 110 VAC/60Hz with US-style plug.
• Depth must be equal to or less than 30" to accommodate benchtop available space. Height and width is unrestricted.
• The equipment shall include a one-yU/I: EAr warranty.
• All instrument documentation (if provided electronically) must be provided via either email or on a
CD/DVD.
This is a brand name or equal requirement (Reference FAR 52.211-6) Reference Anton Paar, Model: DMA- 4100M
SHIP TO:
DLA Energy Alaska Petroleum Laboratory BLDG 986 Warehouse Street JBER-Richardson, AK 99506
CLIN 0011AA
Nomenclature: Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0011.
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $______________
DELIVERY DATE:_______________
CLIN 0012:
Nomenclature: Emulsion Analyzer
QTY: 0001 U/I: EA
UNIT PRICE $_________
EXTENDED PRICE: $____________________
Description: Instrument shall adhere to ASTM D1401, Method for Water Separability of Petroleum Oils
• Initial on-site installation/calibration/hands-on demonstration within two weeks of the equipment arrival.
• All instrument documentation (if provided electronically) must be provided via either email or on a
CD/DVD.
• Weight shall not exceed 75 lbs.
• Test positions shall accommodate 8.
• Automatic timer stop with audible alarm from 1 to 10,000 s.
• Bath capacity shall accommodate maximum of 30 liters.
• Safety fU/I: EAtures included are: low level protection, safety cut-off stirrer lift.
• Stainless steel stirrer paddle. No copper.
• Electrical requirements shall accommodate 230 V, 50 Hz/60 Hz, 2100 W or 115 V, 50 Hz/60 Hz, 1600
Defense Logistics Agency Energy Laboratory Okinawa Chibana Compound, RTE #74 Bldg. 53145 Chibana Okinawa City, Okinawa, Japan 904-2143
CLIN 0012AA:
Nomenclature: INSTALLATION, CALIBRATION & ONSITE DEMONSTRATION FOR CLIN 0012
(WITHIN TWO WEEKS OF ARRIVAL OF CLIN 0012)
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $____________
DELIVERY DATE:_______________
CLIN 0012AB:
Nomenclature: Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0012.
QTY: 0001 U/I: EA
CLIN 0013:
Nomenclature: Net HU/I: EAt of Combustion, Automatic Isoperibol Calorimeter
UNIT PRICE $_________
EXTENDED PRICE: $____________________
DELIVERY DATE:_______________
Description:
Shall adhere to ASTM D4809, Standard Test Method for HU/I: EAt of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter.
• Initial on-site installation/calibration/hands-on demonstration within 12 weeks of the equipment arrival.
• All instrument documentation (if provided electronically) must be provided via either email or on a
CD/DVD.
• The equipment shall include a one-yU/I: EAr warranty.
• Electrical requirements must meet the voltage requirement of 230 Volts/50Hz with NEMA style electrical plugs.
• Dimensions to fit laboratory allotted space/ 42w x 46d x 51h (cm)
• Instrument must be capable of Precision Classification to 0.10%
• Four vessel capability with oxygen “bombs”
• Instrument must be capable of testing a minimum of 6 per hour
• Temperature resolution of 0.0001 °C
• System shall include software, PC, and accessories to support test method application.
This is a brand name or equal requirement (Reference FAR 52.211-6) MFG: Parr, 6400 Calorimeter
Defense Logistics Agency Energy Laboratory Okinawa Chibana Compound, RTE #74 Bldg. 53145 Chibana Okinawa City, Okinawa, Japan 904-2143
CLIN 0013AA:
Nomenclature: INSTALLATION, CALIBRATION & ONSITE DEMONSTRATION FOR CLIN 0013
(WITHIN TWO WEEKS OF ARRIVAL OF CLIN 0013)
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $____________
DELIVERY DATE:_______________
CLIN 0013AB:
Nomenclature: Accessory kit including all items needed to utilize and calibrate equipment CLIN 0013.
CLIN 0014:
Nomenclature: FAME Tester
QTY: 0001 U/I: EA
UNIT PRICE $_________
DELIVERY DATE:_______________
Description:
Shall adhere to ASTM D7797, IP 583 and ASTM D7963
• Initial on-site installation/calibration/hands-on demonstration within two weeks of the equipment arrival.
• All instrument documentation (if provided electronically) must be provided via either email or on a
CD/DVD.
• The equipment shall include a one-yU/I: EAr warranty.
• MU/I: EAsurement range: 10-150 ppm (mg/kg) FAME in Jet Fuels and 20 mg/kg to 20% FAME in
Distillate & Residual Fuels
• Sample size shall not exceed 50ml
• Temperature range: 5 to 35°C maximum
• Electrical requirements shall meet the voltage/ available in volts 50Hz.
• Dimensions to fit laboratory allotted space /equipment size must be less than 56cm height x 38cm wide x
42cm depth to accommodate available space.
• Weight must not exceed 75lbs.
This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Seta Analytics, Fiji MF, Model SA5200-0.
SHIP TO:
FLC Yokosuka Sasebo Fuel Terminals Laboratory Mubanchi Akasaki-cho, Sasebo City, Nagasaki Pref, Japan 857-0064
CLIN 0014AA:
Nomenclature: INSTALLATION, CALIBRATION & ONSITE DEMONSTRATION FOR CLIN 0014
(WITHIN TWO WEEKS OF ARRIVAL OF CLIN 0014)
QTY: 0001 U/I: EA
UNIT PRICE $__________________
CLIN 0014AB:
Nomenclature: Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0014.
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $______________
DELIVERY DATE:_______________
CLIN 0015:
Nomenclature: FAME Tester
QTY: 0001 U/I: EA
UNIT PRICE $_________
EXTENDED PRICE: $____________________
DELIVERY DATE:_______________
Description:
Shall adhere to ASTM D7797, IP 583 and ASTM D7963
• Initial on-site installation/calibration/hands-on demonstration within two weeks of the equipment arrival.
• All instrument documentation (if provided electronically) must be provided via either email or on a
CD/DVD.
• The equipment shall include a one-yU/I: EAr warranty.
• MU/I: EAsurement range: 10-150 ppm (mg/kg) FAME in Jet Fuels and 20 mg/kg to 20% FAME in
Distillate & Residual Fuels
• Sample size shall not exceed 50ml
• Temperature range: 5 to 35°C maximum
• Electrical requirements shall meet the voltage/ available in volts 50Hz.
• Dimensions to fit laboratory allotted space /equipment size must be less than 56cm height x 38cm wide x
This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Seta Analytics, Fiji MF, SHIP TO:
725 Oakridge Dr Romeoville, IL 60446
CLIN 0015AA:
Nomenclature: INSTALLATION, CALIBRATION & ONSITE DEMONSTRATION FOR CLIN 0015
(WITHIN TWO WEEKS OF ARRIVAL OF CLIN 0015)
QTY: 0001 U/I: EA
CLIN 0015AB:
Nomenclature: Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0015.
QTY: 0001 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $______________
DELIVERY DATE:_______________
CLIN 0016:
Nomenclature: FAME Tester
QTY: 0001 U/I: EA
UNIT PRICE $_________
EXTENDED PRICE: $____________________
DELIVERY DATE:_______________
Description:
Shall adhere to ASTM D7797, IP 583 and ASTM D7963
• Initial on-site installation/calibration/hands-on demonstration within two weeks of the equipment arrival.
• All instrument documentation (if provided electronically) must be provided via either email or on a
CD/DVD.
• The equipment shall include a one-yU/I: EAr warranty.
• MU/I: EAsurement range: 10-150 ppm (mg/kg) FAME in Jet Fuels and 20 mg/kg to 20% FAME in
Distillate & Residual Fuels
• Sample size shall not exceed 50ml
• Temperature range: 5 to 35°C maximum
• Electrical requirements shall meet the voltage/ available in volts 50Hz.
• Dimensions to fit laboratory allotted space /equipment size must be less than 56cm height x 38cm wide x
This is a brand name or equal requirement (Reference FAR 52.211-6) Reference MFG Seta Analytics, Fiji MF, SHIP TO:
Pyongtaek Fuel Lab Camp Humphreys Bldg S 848 Anjongri, Pyongtaek 17815 KorU/I: EA, South
CLIN 0016AA:
Nomenclature: INSTALLATION, CALIBRATION & ONSITE DEMONSTRATION FOR CLIN 0016
(WITHIN TWO WEEKS OF ARRIVAL OF CLIN 0016)
QTY: 1 U/I: EA
UNIT PRICE $__________________
EXTENDED PRICE $____________
DELIVERY DATE:_______________
CLIN 0016AB:
Nomenclature: Accessory kit including all items needed to utilize and calibrate equipment for CLIN 0016
QTY: 0001 U/I: EA
UNIT PRICE $__________________
SPECIAL NOTE:
PlU/I: EAse state estimated delivery date after receipt of award (ROA).
Installation, calibration, and onsite demonstration to be completed no later than 2 weeks after delivery.
Invoicing and payment: Invoicing will be in accordance to Wide ArU/I: EA Work Flow (WAWF) Reference FAR 52.232-33 Payment by Electronic Funds Transfer-- System for Award Management (Oct 2018), and DFARS
252.232-7003 ELECTRONIC SUBMISSION OF PAYMENT REQUESTS AND RECEIVING
The following provisions and clauses apply to this acquisition: FAR 52-212-1, Instructions to Offerors Commercial Items; 52.212-2 Evaluation of Commercial Items; the evaluation criteria stated in paragraph (a) of the provision are as follows: The award will be offered to the Lowest Price Technically Acceptable (LPTA) offer made to the Government. 52.212-3 Offeror Representations and Certifications Commercial Items; 52.212-4, Contract Terms and Conditions Commercial Items and 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive orders – Commercial Items. In paragraph (b) of 52.212-5, the following apply:
FAR 52.203-6 ALT 1, 52.204-18, 52.209-6, 52.209-10, 52.219-6, 52.219-8, 52.222-21, 52.223-18, 52.225-13, and 52.232-34. FAR 52.203-3, 52.204-18, 52.209-7, DFAR 252.203-7005, 252.204-7003, 252.204-7008, 252.204-7011, 252.204-7012, 252.204-7015, 252.209-7004, 252.223-7006, 252.225-7001, 252.225-7002, 252.225-7020, 252.225-7031, 252.225-7048, 252.232-7003, 252.232-7006, 252.232-7010, 252.243-7001, 252.244-7000 and 252.247-7023. FAR 52.211-11 shall be applicable.
All responsible Offerors shall submit quotes to Anthony Brown, Anthony.t.brown@dla.mil and Orlando Merritt, Orlando.Merritt@dla.mil. Offers are due by July 31, 2019, 1:00pm U/I: EAstern (Fort Belvoir local time).
mailto:Anthony.t.brown@dla.mil mailto:Orlando.Merritt@dla.mil