PERFORMANCE WORK STATEMENT (PWS)
PERFORMANCE WORK STATEMENT (PWS)
FOR
JPTS STORAGE SERVICES
IN THE AREA OF HOUSTON, TEXAS
1 DESCRIPTION AND PURPOSE OF REQUIRED SERVICES:
1.1 SERVICE STATEMENT:
1.2 AREA OF CONSIDERATION:
1.3 GRADE OF PRODUCT:
1.4 STORAGE TANK REQUIREMENTS:
1.5 ESTIMATED THROUGHPUT:
1.6 TANK TYPE:
1.7 PHYSICAL SYSTEM REQUIREMENTS:
1.7.1 SEALS AND GASKETS:
1.8 BERTHING AND MOORING FACILITIES:
1.8.1 SCHEMATIC OF BERTHING AND MOORING:
1.9 PROPERTY CONTROL, RECORDS AND SYSTEM RECORDS:
1.10 PRODUCT INVENTORY:
2 GENERAL INFORMATION:
2.1 PRODUCT RECEIVING REQUIREMENTS:
2.1.1 NOTIFICATION:
2.1.2 CUSTODY AND RISK OF LOSS:
2.2 PRODUCT SHIPPING REQUIREMENTS:
2.2.1 NOTIFICATION:
2.2.2 CUSTODY AND RISK OF LOSS:
2.3 BILLING:
2.4 STORE AND HANDLE FUEL:
2.5 TRANSFERS:
2.6 REIMBURSEMENT:
2.7 ANCILLARY FACILITIES:
2.7.1 TANK:
2.7.2 FILTRATION:
2.7.3 LABORATORY:
3 PRODUCT QUALITY SURVEILLANCE
3.1 QUALITY CONTROL PLAN:
3.2 SAMPLES AND TESTING:
3.3 PRODUCT QUALITY/QUANTITY SURVEILLANCE:
3.4 OFF-SPECIFICATION:
3.4.1 3.4.2
4 MAINTENANCE
4.1 FUEL SYSTEMS MAINTENANCE:
4.1.1 TANK INSPECTION, CLEANING AND REPAIR:
4.1.2
5 LOGISTICAL SUPPORT
5.1
6 COMPLIANCE REQUIREMENTS
6.1 APPLICABLE DIRECTIVES:
APPENDIX A
APPENDIX B
1 Description and Purpose of Required services:
1.1 Service Statement:
The following terms and conditions are applicable to obtain the necessary services and facilities to receive and store, protect, and ship one grade of government-owned petroleum product, Jet Petroleum Thermally Stable (JPTS) aviation turbine fuel, in the Houston, Texas area, for a multi-year contract (5 year), beginning 1 December 2014 and ending 30 November 2019. The Service Provider is also required to load the product for transportation via pipeline, ocean tanker, rail car, tank trucks, and inter-modal containers (ISO containers).
1.2 Area of Consideration:
Within 50 miles of the Houston, TX area.
1.3 Grade of Product:
Thermally Stable Aviation Turbine Fuel (JPTS) per MIL-DTL-25524E or latest version.
1.4 Storage Tank Requirements:
Approximately 75,000 barrels of storage capacity with a minimum of two tanks interconnected, equipped with Automatic Tank Gauging (ATG), and isolated from other facilities and products handled within the tank farm.
Dedicated, as defined in MIL-STD 3004C - MILITARY STANDARD, Change 1, or latest version.
1.5 Estimated Throughput:
The U. S. Government will be entitled to initial fill and final shipment free of charge during the contract performance period and in addition to 48,000 barrels in a calendar year, hereafter referred to as allowed throughput. Offers shall indicate any additional through-put charge for volumes in excess of the allowed throughput. Initial fill is defined as all receipts required to fill 100% of the awarded fill capacity. Final Shipment is defined as all remaining DoD product at contract termination. The excess throughput charge will be calculated by multiplying the number of barrels shipped and/or received over the above throughput.
1.6 Tank Type:
Service Provider (SP) must identify type of construction (i.e. floating roof, Cone, etc.) for all tanks included in the offer. Tank receiving and delivery lines shall be in dedicated JPTS service. The tanks shall be connected so as to provide the capability of re-circulating/filtering of products between tanks and ATG. Provisions shall be available for displacing common loading/unloading lines to a tank other than JPTS storage tanks. Those provisions should be explained in the SP’s proposal. All tanks and facilities must meet the minimum requirement of the current API, NFPA, CFR codes and standards; all federal, state, and local laws/regulations, etc., applicable to tanks and facilities of the type to be provided. It will be the SP’s responsibility to meet and maintain compliance with the above requirements.
1.7 Physical System Requirements:
Dedicated JPTS storage and handling facilities capable of receiving, storing, protecting, and shipping U. S.
Government-owned petroleum product. The SP’s proposal shall provide the data required by DLA Energy Contract Provision L-0004-L116.01 - DATA REQUIREMENTS (STORAGE) (DLA ENERGY NOV 2012). The SP’s proposal shall provide the tank cleaning and inspection data required by DLA Energy Contract Provisions E-0002-E18 - INSPECTION AND CLEANING OF BULK PETROLEUM STORAGE TANKS (DLA ENERGY NOV 2003). The tank cleaning and inspection data will be evaluated and utilized as an evaluation factor in determining the governments risk associated with the utilization of the facility.
1.7.1 Seals and Gaskets:
All seals and gaskets used in the JPTS storage system components shall be made of vitron, Teflon or nitro. Seals and gaskets made of brass, neoprene or bronze materials shall not be used. The SP’s proposal will include details on the types of seals and gaskets used in the system.
1.7.2 Unsatisfactory Material: the following materials are unsatisfactory for use in JPTS systems:
• Copper
• Zinc
• Silver
• Mild steel, uncoated
• Magnesium
• Bronze
• Brass
• Cast Iron
• Tin
NOTE: The use of these materials in the offered system may result in an unsatisfactory technical evaluation. The SP will provide adequate details in the proposal to evaluate the materials used in the offered JPTS service.
1.8 Berthing and Mooring Facilities:
The SP’s berthing and mooring facility shall be capable of handling a minimum 38,000 dead weight ton (DWT); as a minimum berth vessels with length of 280 feet LOA, 60 feet WOA and 15 feet maximum loaded at mean low water from the SP’s berthing and mooring facility to the open ocean. The fuel loading lines from the dock through the manifold to the tanks shall be capable of receiving at a rate of at least 2,000 barrels per hour.
1.8.1 Schematic of Berthing and Mooring:
The SP’s proposal is required to provide a detailed schematic of the berthing and mooring facilities showing the minimum and maximum capabilities to include current dredging charts for evaluation IAW DLA Energy Contract Provision L116.01 - DATA REQUIREMENTS (STORAGE) (DLA ENERGY NOV 2003) and be prepared to permit the Government to occasionally utilize the maximum berthing and mooring facility capability. The SP’s proposal shall provide any port restriction/requirements and harbor fees, along with height restrictions from ships manifold to the waterline during loading/unloading. Berthing data will be evaluated and utilized as an evaluation factor in determining the Government’s risk associated with the utilization of their facility.
1.9 Property Control, Records and System Records:
The SP shall provide Property Control and System Records in compliance with Contract Provision I119.04 - INTENTORY CONTROL RECORDS AND SYSTEMS OF RECORD (DLA ENERGY (JUN 2009). A SP’s furnished computer system shall meet the current commercial standards for a computer system capable of accomplishing the data reporting and records keeping required by the Fuels Automated System (FAS), as shown in Section 1.10; maintaining the data collection and records keeping associated with product quality surveillance (i.e., product analysis and testing reports); and the document collection associated with the SP’s preventive maintenance program, etc.
1.10 Product Inventory:
The SP shall enter inventory, receipt and sales data of Government-owned product JPTS directly into the Government’s Fuel Automated System (FAS) utilizing the SP’s furnished computer system via SP furnished internet access (with static IP address capability) or creation of a dial-in account to the DLA Energy FAS web server IAW Contract Provision I119.04. Additional data and requirements can be found in MIL-STD 3004C - MILITARY STANDARD or latest version AND DOD 4140.25M - MANAGEMENT OF BULK PETROLEUM PRODUCTS, NATURAL GAS, AND COAL or latest version.
a. Document each order, receipt, transfer, sale, loss, credit, gain, and adjustment.
b. Maintain auditable product document control files.
c. Use inventory measurement practices that support product accountability and auditability.
2 General Information:
2.1 Product Receiving Requirements:
The SP’s facilities shall be capable of safely receiving petroleum product JPTS via pipeline, ocean tanker, rail car, tank trucks, and inter-modal (ISO) containers 24 hours per day, 7 days per week without causing, delay, interruption, or demurrage. All delivery shall be made during the normal duty hours, Monday through Friday and Saturday, Sunday and federal holidays as stipulated in the wage grade determination excepted. The SP’s facilities shall be capable of receipt by ocean going tanker/barge with pumping rates compatible with the mode of transportation tendered (minimum 2000 barrels per hour for barges and 8,000 barrels per hour for tankers). Lesser pumping rates will be considered but cost assessments will be factored in when evaluating offers. Consideration will be given to unrestricted access to product in accordance with DLAD 52.211-9072, formerly Contract Provision F1.04 - GENERAL RECEIVING AND STORING
CONDITIONS (DLA ENERGY OCT 1997)(DLAD 52.211-9072), P2 – RECIEPT AND SHIPMENT OF
PETROLEUM PRODUCT (DLA ENERGY NOV 2010) and IAW MIL-STD 3004C, Change 1, or latest version.
NOTE: SP shall provide a detailed plan on how the staff would perform normal operations in his proposal.
2.1.1 Notification:
The Government shall give notice to the SP of scheduled product receipts. Receipt notification shall include the estimated quantity, mode of delivery, projected delivery date, shipment source, grade or type of product, and any special instructions.
NOTE: The Contractor shall be held accountable for demurrage charges arising from delay(s) in receipt, except when the delay(s) are caused by reason beyond the control and without the fault or negligence of the SP and its subcontractors.
2.1.2 Custody and Risk of Loss:
Custody and risk of loss is in accordance with DLAD 52.211-9072, formerly Contract Provision F1.04 - GENERAL RECEIVING AND STORING CONDITIONS (DLA ENERGY OCT 1997), P2 – RECIEPT AND SHIPMENT OF PETROLEUM PRODUCT (DLA ENERGY NOV 2010) and IAW MIL-STD 3004C, Change 1, or latest version, unless otherwise agreed upon.
2.2 Product Shipping Requirements:
The SP’s facilities shall be capable of safely issuing U. S. Government-owned petroleum product JPTS via pipeline, ocean tanker, rail car, tank trucks, and inter-modal (ISO) containers 24 hours per day, 7 days per week without causing delay, interruption, or demurrage. All delivery shall be made during the normal duty hours Monday through Friday and Saturday, Sunday and federal holidays as stipulated in the wage grade determination excepted. The SP’s facilities shall be capable of issue to ocean going tanker/barge with pumping rates compatible with the mode of transportation tendered (minimum 2000 barrels per hour for barges and 8,000 barrels per hour for tankers). Lesser pumping rates will be considered but cost assessments will be factored in when evaluating offers. Consideration will be given to unrestricted access to product IAW Contract Provision F1.05 - GENERAL SHIPPING CONDITION (DLA ENERGY OCT 1997), P2 – RECIEPT AND SHIPMENT OF PETROLEUM PRODUCT (DLA ENERGY NOV 2010) and IAW MIL-STD 3004C, Change 1, or latest version.
NOTE: SP shall provide a detailed plan on how the staff would perform normal operations in his proposal.
2.2.1 Notification:
The Government shall give notice to the SP of scheduled product shipping. Notification shall include the estimated quantity, mode of delivery, projected delivery date, shipment source, grade or type of product, and any special instructions.
NOTE: The SP shall be held accountable for demurrage charges arising from delay(s) in issuing, except when the delay(s) are caused by reason beyond the control and without the fault or negligence of the SP and its subcontractors.
2.3 Billing:
The Contractor shall prepare and distribute Government bills of lading and all necessary paperwork to include customs documentation if necessary used in issuing product IAW Contract Provision I119.04 - INVENTORY CONTROL RECORD AND RECORD SYSTEM OF RECORD (DLA ENERGY JUN 2009) unless otherwise directed. Bills of lading, routing instructions, and transportation assistance shall be furnished by DLA Energy-Americas East or Service activity placing orders.
2.4 Store and Handle Fuel:
The Contractor shall at all times safely maintain product quantity, quality, and availability to meet its intended use.
The Contractor shall maintain the product storage facilities IAW industry standards and IAW with DLAD 52.211-9072, formerly Contract Provision F1.04 - GENERAL RECEIVING AND STORING CONDITIONS.
2.2.2 Custody and Risk of Loss:
Custody and risk of loss is IAW Contract Provision F1.05 - GENERAL SHIPPING CONDITION (DLA ENERGY OCT 1997), P2 – RECIEPT AND SHIPMENT OF PETROLEUM PRODUCT (DLA ENERGY NOV 2010) and IAW MIL-STD 3004C, Change 1, or latest version, unless otherwise agreed upon.
2.5 Transfers:
The capability to transfer product between storage tanks on a seven day per week basis is required. When needed, can be either Contractor or Government directed, the Contractor shall transfer product between tanks to consolidate types or grades in preparation for receipts or issues at no additional cost to the government. The responsibility for preventing commingling or contamination during transfers rests completely with the Contractor in accordance with DLAD 52.211- 9072, formerly Contract Provision F1.04 - GENERAL RECEIVING AND STORING CONDITIONS.
2.6 Reimbursement:
The Contractor shall reimburse the U. S. Government the cost of lost product in excess of Inventory Operating Gains or Loss Tolerances as defined by Contract Provision I119.04 - INVENTORY CONTROL RECORDS AND SYSTEMS
OF RECORD.
2.7 Ancillary Facilities:
The facilities to be furnished under this requirement shall include, as a minimum, the following:
2.7.1 Tank:
All tanks shall be equipped with ATG. Also, tanks and facilities offered must meet the minimum requirements of the current AOI STANDARDS – ASSOCIATION OF ILLUSTRATORS, the NFPA CODES AND STANDARDS – THE NATIONAL FIRE PROTECTION ASSOCIATION CODE AND STANADARDS, and/or all comparable national, State or Local laws, regulations, etc., applicable to tanks and facilities of the type to be provided. The facility must be equipped with illumination to allow receipt/issue operations during hours of darkness. (Also refer to Section 1.6)
2.7.2 Filtration:
The SP shall provide a filtration system that meets the specifications outlined in the current API/EI 1581 SPECIFICATION AND QUALIFICATION PROCEDURES FOR AVIATION JET FUEL FILTER/SEPARATORS, Fifth Edition (JUL 2002), Addendum 20, 2006, or latest version, Category M (Military), Type S Aviation Jet Fuel Filter Separator. Filtration must be sized to meet receiving and shipping operations and tank to tank transfer IAW MIL- STD 3004C, Change 1, or latest version.
2.7.3 Laboratory:
The Contractor shall provide laboratory services to test U. S. Government products IAW MIL-DTL-25524E or latest version and MIL-STD-3004C, Change 1, or latest version requirements at no additional cost to the Government. The SP shall provide a Complete Specification Inspection Test (Type “A” Test). If the Contractor cannot provide a type “A” test, the Contractor shall be responsible for shipping the required samples at their expense to a laboratory acceptable to the Government representative. The calibration of testing equipment will be IAW Contract Provision
C19.07 – SAMPLING AND TESTING OF PETROLEUM PRODUCTS (STORAGE).
3 PRODUCT QUALITY SURVEILLANCE.
3.1 Quality Control Plan:
The Quality Control Plan (QCP) will describe how the contractor shall designate personnel, facilities, and equipment on-site to accomplish routine tests and procedures to include tanker loading. The QCP shall provide comprehensive and detailed step-by-step procedures covering all requirements in Contract Provision E1.11, QUALITY CONTROL PLAN. Following contract award, the SP shall have 30 days to submit the detailed plan to the QAR and Contracting Officer for review and acceptance. Written procedures must be clear and concise as to: what is done, where it's done, when it's done, how it's done, and who (which SP’s employee position) does it. It must describe, in proper sequence, how contract compliance will be achieved and how the contractor intends to perform the required services in order to ensure that all products meet specification requirements during the performance of the contract. Subsequent to contract award, revisions to the Plan shall be submitted to the Contracting Officer within 30 days after the revision is deemed necessary. The plan shall include procedures for the following operations, as they affect quality control, and an organizational chart that identifies responsible parties for these operations:
a. Receiving - See DLAD 52.211-9072, formerly Contract Provision F1.04
b. Blending – See Contract Provision F45.03
c. Sampling – See Contract Provision C19.07
d. Testing – See Contract Provision C19.07 and E28
e. Calibration P2 and API MPMS
f. Storage and Handling – See Contract Provision E28 and I116
g. Loading and Shipping – See Contract Provision F1.05
h. Quantity Determination – See Contract Provision F1.14
i. Records and Reports – See Contract Provision I119.04
j. Corrective Action
The QCP must describe at a minimum those functions pertinent to contract performance and compliance. The QCP must be reviewed/approved upon initial award to assure the technical and procedural requirements are adequately described. The QCP must be dynamic (i.e., modified or extended as changes in technical or procedural requirements occur). SP responsibility to inspect product and services shall be in accordance with Contract Provision E28, CONTRACTOR INSPECTION RESPONSIBILITIES.
3.2 Samples and Testing:
The SP shall provide to the government representative samples of the product being stored, shipped, or received under the contract, at the request of, and in the manner designated by the QAR. These samples shall be provided in addition to samples required elsewhere in the contract and referenced in the QCP. The total number of these samples to be provided during any 12 month period shall not exceed eight times the number of tanks specified in the contract IAW Contract Provision C19.07 - SAMPLING AND TESTING OF PETROLEUM PRODUCTS (STORAGE) (DLA ENERGY JAN 2012) and contract Provision E28 - CONTRACTOR INSPECTION RESPONSIBILITIES
(STORAGE) (DLA ENERGY DEC 2011).
3.3 Product Quality/Quantity Surveillance:
The SP will be responsible for maintaining the quality of the Government-owned product stored at the SP’s facility IAW the current version of MIL-STD-3004C, Change 1, or latest version. No petroleum product shall be received or shipped without first determining and confirming conformance with product quality/quantity requirements. No conveyance/container shall be loaded/unloaded until it is inspected by a qualified SP’s person and deemed suitable to carry the intended product. Products shall be shipped on a first-in, first-out basis unless otherwise approved or directed by the QAR. Non-conforming product shall be reported to the QAR immediately. Anytime product is received into a tank, the tank’s contents shall be suspended from issue pending quality conformance sampling and testing. The Contractor shall ensure that certificates of quality conformance (test reports) are maintained on file for all on-hand fuel stocks.
3.4 Off-Specification:
The SP shall report immediately to DLA Energy-America East or the QAR, all receipts or on hand stocks that fail to meet product quality for receipt, storage or shipment IAW MIL-STD-3004C or latest version. Suspected off-specification product will be isolated and shall not be released for shipment until authorized by DLA Energy-America East or the QAR.
3.4.1 The SP shall provide the Quality Assurance Representative (QAR) with information pertaining to the amount of any fuel deemed unrecoverable, the reason why the fuel cannot be recovered, and an analysis of the unrecovered fuel quality. All unrecoverable tank bottoms/line fill quantities will be reported to the Property Administrator for disposition instructions. Contaminated/off-specification product will be reported to the QAR in order to obtain disposition instructions. Tanks out of service for cleaning shall be removed from revenue until such time as they are returned to Government Service IAW DLA Energy Contract Provision E18 INSPECTION AND CLEANING OF BULK
PETROLEUM STORAGE TANKS.
3.4.2 Establish procedures for immediately notifying the QAR when irregularities occur or are suspected and on all occasions when loading/unloading is interrupted. Establish procedures for completing and distributing required documentation prior to release of the vessel. Documentation includes DD Form 250-1 and DD Form 250-1 continuation sheet, ullage reports, and results of quality/quantity investigations.
4 MAINTENANCE
4.1 Fuel Systems Maintenance:
The SP shall maintain the fuel systems, e.g., facilities and equipment according to manufacturer specifications, best commercial practices, all state and federal guidelines and directives, and the Maintenance Plan at contractor expense.
The facility will be maintained in such a manner that it remains capable of providing all services required on this contract.
4.1.1 Tank inspection, Cleaning and Repair:
Tanks shall be repaired, cleaned and returned to Government service IAW DLA Energy Contract Provision E18 - INSPECTION AND CLEANING OF BULK PETROLEUM STORAGE TANKS. The SP shall empty, inspect, clean or repair each bulk petroleum storage tank and dispose of all tank bottom waste for each tank covered under this contract. The SP shall transfer remaining product to alternate tanks during tank cleaning as required. The time for cleaning will be measured from the date of the last cleaning regardless of whether the tank was under contract with the Government. Tanks requiring repair or cleaning will be removed from revenue until such time as they are returned to Government Service. Samples will be taken and tested. If tank cleaning is required earlier than the criteria listed below and the Government is shown to be responsible, then the Government will incur cleaning, sampling, and testing costs.
4.1.2 The SP shall establish procedures for immediately notifying the QAR when irregularities occur or are suspected and on all occasions when loading/unloading is interrupted. Establish procedures for completing and distributing required documentation prior to release of the conveyances.
5 LOGISTICAL SUPPORT
5.1 All costs for providing the services required under this contract, except those specified below, will be included in the SP offer and will be included in the monthly usage charge.
6 COMPLIANCE REQUIREMENTS
6.1 Applicable Directives:
The SP shall comply with applicable statutory and regulatory requirements and validated best commercial practices.
This requirement applies to all performance criteria and deliverables set forth in this document. Appendix A provides a list of directives and other guidance that are applicable to the performance of this contract. The list is not all inclusive.
Additional information regarding DLA Energy Standards and Publications can be found at:
http://www.desc.dla.mil/DCM/DCMPage.asp?LinkID=DESC. In the event of conflicting guidance, contact the Contracting Officer (CO) for clarification.
http://www.desc.dla.mil/DCM/DCMPage.asp?LinkID=DESC
APPENDIX A
APPLICABLE DIRECTIVES
This list is not all-inclusive and is only intended to call the SP’s attention to certain potentially applicable requirements.
This list may change over time or vary according to the location of the terminal facility. The SP remains responsible for knowing and complying with all applicable federal, state, and local laws and regulations throughout the term of this contract Federal Acquisition Regulation.
DoD 4140.25-M, DoD Management of Bulk Petroleum Products, Natural Gas, and Coal DoD 4140.25-M, DESC Interim Guidance MIL-DTL-25524E, Thermally Stable Aviation Turbine Fuel MIL-STD- 3004C, Change 1, DoD Standard Practice Quality Surveillance for Fuels, Lubricants and Related Products 29 CFR 1910.120, Hazardous Waste Operations and Emergency Response 29 CFR 1910.132, Personal Protective Equipment 29 CFR 1910.134, Respiratory Protection Program 29 CFR 1910.146, Confined Space Entry 29 CFR 1919.147, Energized Equipment, Lockout/Tagout 29 CFR 1910.1025 Toxic Substances - Lead 29 CFR 1910.1200, Hazardous Communication Program 29 CFR 1904, Reporting of Occupational Injuries and Illnesses 29 CFR 1925, Safety & Health Standards for Federal Service Contracts 33 CFR 154, Oil Pollution Prevention Operations Manual 40 CFR 112, Oil Pollution Prevention 40 CFR 122, NPDES Permit Plan 40 CFR 260-268, EPA Hazardous Waste Management System Plan (2nd link) 40 CFR 280, Underground Storage Tanks 41 CFR 50-204, Safety & Health Standards for Federal Supply Contracts 49 CFR 171, Hazardous Materials Regulations 49 CFR 172, Hazardous Materials Regulations 49 CFR 195 (Pipeline Safety – Where Applicable) Oil Pollution Act of 1990 National Fire Protection Association (NFPA)/Uniform Fire Code (UF) NFPA 30, Flammable and Combustible Liquids Code API 510, Pressure Vessel Inspection Code: Maintenance Inspection, Rating, Repair, and Alteration API 570, Pipeline Inspection Code API 620, Design and Construction of Large,Welded, Low-Pressure Storage Tanks API 650, Welded Steel Tanks for Oil Storage API 653, Tank Inspection, Repair, Alteration and Reconstruction API/EI 1581, Specifications and Qualification Procedures for Aviation Jet Fuel Filter/Separators, Fifth Edition 2002 (Addendum 20, 2006), or most recent edition API 2610, Design, Construction, Operation, Maintenance, and Inspection of Terminal & Inspection of Terminal & Tank Facilities API Manual of Petroleum Measurement Standards (MPMS) Chapter 3, Method of Gauging Petroleum Products API MPMS Chapter 4, Proving Systems API MPMS Chapter 5, Metering API MPMS Chapter 7, Methods of Measuring the Temperature of Petroleum Products API MPMS Standards Chapter 8, Sampling API MPMS Chapter 9, Section 1 Density Determination API MPMS Chapter 11.1, Vol Correction Factors API MPMS Chapter 12, Calculation of Petroleum Quantities, Section1 – Calculation of Static Petroleum Quantities, Part 1 – Upright Cylindrical Tanks and Marine Vessels API MPMS Chapter 17 Marine Measurement, All Sections 14
APPENDIX B
ABBREVIATIONS AND ACRONYMS
API – American Petroleum Institute CFR - Code of Federal Regulations CO - Contracting Officer DLA - Defense Logistics Agency DoD - Department of Defense DWT - Deadweight Tonnage FAS - Fuels Automated System IAW - In Accordance With JPTS - Thermally Stable Aviation Turbine Fuel LOA - Length overall NFPA - National Fire Protection Association PWS - Performance Work Statement QAR - Quality Assurance Representative QCP - Quality Control Plan SP - Service Provider WOA – Width overall
1 Description and Purpose of Required services:
1.1 Service Statement:
1.2 Area of Consideration:
1.3 Grade of Product:
1.4 Storage Tank Requirements:
1.5 Estimated Throughput:
1.6 Tank Type:
1.7 Physical System Requirements:
1.7.1 Seals and Gaskets:
1.8 Berthing and Mooring Facilities:
1.8.1 Schematic of Berthing and Mooring:
1.9 Property Control, Records and System Records:
1.10 Product Inventory:
2 General Information:
2.1 Product Receiving Requirements:
2.1.1 Notification:
2.1.2 Custody and Risk of Loss:
2.2 Product Shipping Requirements:
2.2.1 Notification:
2.3 Billing:
2.4 Store and Handle Fuel:
2.2.2 Custody and Risk of Loss:
2.5 Transfers:
2T2.6 Reimbursement:
2.7 Ancillary Facilities:
2.7.1 Tank:
2.7.2 Filtration:
2.7.3 Laboratory:
3 PRODUCT QUALITY SURVEILLANCE.
3.1 Quality Control Plan:
3.2 Samples and Testing:
3.3 Product Quality/Quantity Surveillance:
3.4 Off-Specification:
4 MAINTENANCE
4.1 Fuel Systems Maintenance:
4.1.1 Tank inspection, Cleaning and Repair:
5 LOGISTICAL SUPPORT
6 COMPLIANCE REQUIREMENTS
6.1 Applicable Directives:
APPENDIX A
APPENDIX B
SP0600-14-R-0505
Attachment 5
Storage, Houston, TX
PAST PERFORMANCE EXPERIENCE FORM
(To be completed by offeror and submitted as part of Past Performance submission)
CONTRACTOR: CONTRACT:
ADDRESS:
POINT OF CONTACT AND TITLE: TELEPHONE:
EMAIL:
AGENCY:
CONTRACT/PROJECT TITLE AND LOCATION:
DOLLAR VALUE:
PRIME or SUBCONTRACTOR:
CONTRACT/PROJECT DESCRIPTION:
(Features of work that the offeror completed, including a statement of the total dollar value of this work)
SOURCE SELECTION INFORMATION – SEE FAR 2.101 AND 3.104
WD 05-2515 (Rev.-15) was first posted on www.wdol.gov on 06/25/2013
REGISTER OF WAGE DETERMINATIONS UNDER | U.S. DEPARTMENT OF LABOR
THE SERVICE CONTRACT ACT | EMPLOYMENT STANDARDS ADMINISTRATION
By direction of the Secretary of Labor | WAGE AND HOUR DIVISION
| WASHINGTON D.C. 20210
| Wage Determination No.: 2005-2515 Diane C. Koplewski Division of | Revision No.: 15 Director Wage Determinations| Date Of Revision: 06/19/2013 State: Texas
Area: Texas Counties of Austin, Brazoria, Chambers, Colorado, Fort Bend, Galveston, Grimes, Harris, Houston, Jackson, Lavaca, Liberty, Madison, Matagorda, Montgomery, San Jacinto, Trinity, Walker, Waller, Washington, Wharton **Fringe Benefits Required Follow the Occupational Listing**
OCCUPATION CODE - TITLE FOOTNOTE RATE
01000 - Administrative Support And Clerical Occupations 01011 - Accounting Clerk I 14.98 01012 - Accounting Clerk II 16.82 01013 - Accounting Clerk III 18.82 01020 - Administrative Assistant 25.91 01040 - Court Reporter 21.79 01051 - Data Entry Operator I 13.24 01052 - Data Entry Operator II 14.45 01060 - Dispatcher, Motor Vehicle 15.96 01070 - Document Preparation Clerk 13.41 01090 - Duplicating Machine Operator 13.41 01111 - General Clerk I 11.88 01112 - General Clerk II 13.27 01113 - General Clerk III 14.90 01120 - Housing Referral Assistant 20.69 01141 - Messenger Courier 12.55 01191 - Order Clerk I 13.52 01192 - Order Clerk II 15.24 01261 - Personnel Assistant (Employment) I 15.43 01262 - Personnel Assistant (Employment) II 17.27 01263 - Personnel Assistant (Employment) III 19.25 01270 - Production Control Clerk 19.10 01280 - Receptionist 12.02 01290 - Rental Clerk 14.75 01300 - Scheduler, Maintenance 16.59 01311 - Secretary I 16.59 01312 - Secretary II 18.57 01313 - Secretary III 20.69 01320 - Service Order Dispatcher 15.16 01410 - Supply Technician 25.91 01420 - Survey Worker 17.79 01531 - Travel Clerk I 13.71 01532 - Travel Clerk II 14.81 01533 - Travel Clerk III 15.83 01611 - Word Processor I 14.29 01612 - Word Processor II 16.04 01613 - Word Processor III 17.95 05000 - Automotive Service Occupations 05005 - Automobile Body Repairer, Fiberglass 25.76
4/29/2014http://www.wdol.gov/wdol/scafiles/std/05-2515.txt?v=15
05010 - Automotive Electrician 23.79 05040 - Automotive Glass Installer 21.96 05070 - Automotive Worker 21.96 05110 - Mobile Equipment Servicer 20.23 05130 - Motor Equipment Metal Mechanic 25.76 05160 - Motor Equipment Metal Worker 21.96 05190 - Motor Vehicle Mechanic 25.76 05220 - Motor Vehicle Mechanic Helper 19.40 05250 - Motor Vehicle Upholstery Worker 20.83 05280 - Motor Vehicle Wrecker 21.96 05310 - Painter, Automotive 23.79 05340 - Radiator Repair Specialist 22.88 05370 - Tire Repairer 14.40 05400 - Transmission Repair Specialist 25.76 07000 - Food Preparation And Service Occupations 07010 - Baker 10.06 07041 - Cook I 9.52 07042 - Cook II 10.88 07070 - Dishwasher 8.11 07130 - Food Service Worker 9.12 07210 - Meat Cutter 12.91 07260 - Waiter/Waitress 8.19 09000 - Furniture Maintenance And Repair Occupations 09010 - Electrostatic Spray Painter 18.32 09040 - Furniture Handler 11.95 09080 - Furniture Refinisher 17.70 09090 - Furniture Refinisher Helper 14.58 09110 - Furniture Repairer, Minor 16.82 09130 - Upholsterer 18.32 11000 - General Services And Support Occupations 11030 - Cleaner, Vehicles 9.90 11060 - Elevator Operator 8.82 11090 - Gardener 14.52 11122 - Housekeeping Aide 8.84 11150 - Janitor 8.84 11210 - Laborer, Grounds Maintenance 10.93 11240 - Maid or Houseman 7.96 11260 - Pruner 9.25 11270 - Tractor Operator 12.82 11330 - Trail Maintenance Worker 10.93 11360 - Window Cleaner 9.81 12000 - Health Occupations 12010 - Ambulance Driver 15.00 12011 - Breath Alcohol Technician 15.64 12012 - Certified Occupational Therapist Assistant 23.69 12015 - Certified Physical Therapist Assistant 24.52 12020 - Dental Assistant 15.64 12025 - Dental Hygienist 32.93 12030 - EKG Technician 25.92 12035 - Electroneurodiagnostic Technologist 25.92 12040 - Emergency Medical Technician 15.00 12071 - Licensed Practical Nurse I 19.05 12072 - Licensed Practical Nurse II 21.32 12073 - Licensed Practical Nurse III 23.76 12100 - Medical Assistant 12.50 12130 - Medical Laboratory Technician 16.63 12160 - Medical Record Clerk 14.53 12190 - Medical Record Technician 16.57 12195 - Medical Transcriptionist 16.81 12210 - Nuclear Medicine Technologist 35.13 12221 - Nursing Assistant I 8.57
12222 - Nursing Assistant II 10.36 12223 - Nursing Assistant III 11.31 12224 - Nursing Assistant IV 12.69 12235 - Optical Dispenser 16.79 12236 - Optical Technician 15.29 12250 - Pharmacy Technician 19.18 12280 - Phlebotomist 13.30 12305 - Radiologic Technologist 26.70 12311 - Registered Nurse I 30.36 12312 - Registered Nurse II 38.37 12313 - Registered Nurse II, Specialist 38.37 12314 - Registered Nurse III 44.91 12315 - Registered Nurse III, Anesthetist 44.91 12316 - Registered Nurse IV 53.84 12317 - Scheduler (Drug and Alcohol Testing) 21.85 13000 - Information And Arts Occupations 13011 - Exhibits Specialist I 19.30 13012 - Exhibits Specialist II 24.74 13013 - Exhibits Specialist III 28.94 13041 - Illustrator I 19.30 13042 - Illustrator II 23.91 13043 - Illustrator III 30.12 13047 - Librarian 26.69 13050 - Library Aide/Clerk 10.84 13054 - Library Information Technology Systems 24.09 Administrator 13058 - Library Technician 16.04 13061 - Media Specialist I 17.39 13062 - Media Specialist II 19.46 13063 - Media Specialist III 21.68 13071 - Photographer I 15.32 13072 - Photographer II 18.15 13073 - Photographer III 22.56 13074 - Photographer IV 27.49 13075 - Photographer V 33.07 13110 - Video Teleconference Technician 16.73 14000 - Information Technology Occupations 14041 - Computer Operator I 17.31 14042 - Computer Operator II 19.37 14043 - Computer Operator III 21.59 14044 - Computer Operator IV 24.00 14045 - Computer Operator V 26.57 14071 - Computer Programmer I (see 1) 26.04 14072 - Computer Programmer II (see 1) 14073 - Computer Programmer III (see 1) 14074 - Computer Programmer IV (see 1) 14101 - Computer Systems Analyst I (see 1) 14102 - Computer Systems Analyst II (see 1) 14103 - Computer Systems Analyst III (see 1) 14150 - Peripheral Equipment Operator 17.31 14160 - Personal Computer Support Technician 24.00 15000 - Instructional Occupations 15010 - Aircrew Training Devices Instructor (Non-Rated) 33.08 15020 - Aircrew Training Devices Instructor (Rated) 40.02 15030 - Air Crew Training Devices Instructor (Pilot) 47.98 15050 - Computer Based Training Specialist / Instructor 33.08 15060 - Educational Technologist 29.23 15070 - Flight Instructor (Pilot) 47.98 15080 - Graphic Artist 26.72 15090 - Technical Instructor 22.43 15095 - Technical Instructor/Course Developer 27.43
15110 - Test Proctor 18.43 15120 - Tutor 18.43 16000 - Laundry, Dry-Cleaning, Pressing And Related Occupations 16010 - Assembler 9.40 16030 - Counter Attendant 9.40 16040 - Dry Cleaner 12.06 16070 - Finisher, Flatwork, Machine 9.40 16090 - Presser, Hand 9.40 16110 - Presser, Machine, Drycleaning 9.40 16130 - Presser, Machine, Shirts 9.40 16160 - Presser, Machine, Wearing Apparel, Laundry 9.40 16190 - Sewing Machine Operator 12.79 16220 - Tailor 13.75 16250 - Washer, Machine 10.32 19000 - Machine Tool Operation And Repair Occupations 19010 - Machine-Tool Operator (Tool Room) 19.71 19040 - Tool And Die Maker 23.23 21000 - Materials Handling And Packing Occupations 21020 - Forklift Operator 13.25 21030 - Material Coordinator 19.46 21040 - Material Expediter 19.46 21050 - Material Handling Laborer 12.26 21071 - Order Filler 11.47 21080 - Production Line Worker (Food Processing) 13.25 21110 - Shipping Packer 14.60 21130 - Shipping/Receiving Clerk 14.60 21140 - Store Worker I 11.34 21150 - Stock Clerk 16.06 21210 - Tools And Parts Attendant 13.58 21410 - Warehouse Specialist 13.25 23000 - Mechanics And Maintenance And Repair Occupations 23010 - Aerospace Structural Welder 29.47 23021 - Aircraft Mechanic I 28.07 23022 - Aircraft Mechanic II 29.47 23023 - Aircraft Mechanic III 30.94 23040 - Aircraft Mechanic Helper 21.98 23050 - Aircraft, Painter 25.61 23060 - Aircraft Servicer 24.44 23080 - Aircraft Worker 25.76 23110 - Appliance Mechanic 18.61 23120 - Bicycle Repairer 13.91 23125 - Cable Splicer 25.34 23130 - Carpenter, Maintenance 19.71 23140 - Carpet Layer 18.45 23160 - Electrician, Maintenance 26.51 23181 - Electronics Technician Maintenance I 21.28 23182 - Electronics Technician Maintenance II 23.89 23183 - Electronics Technician Maintenance III 25.10 23260 - Fabric Worker 17.17 23290 - Fire Alarm System Mechanic 19.95 23310 - Fire Extinguisher Repairer 15.88 23311 - Fuel Distribution System Mechanic 20.96 23312 - Fuel Distribution System Operator 16.33 23370 - General Maintenance Worker 18.08 23380 - Ground Support Equipment Mechanic 28.07 23381 - Ground Support Equipment Servicer 24.44 23382 - Ground Support Equipment Worker 25.76 23391 - Gunsmith I 15.88 23392 - Gunsmith II 18.45 23393 - Gunsmith III 20.81 23410 - Heating, Ventilation And Air-Conditioning 21.04
Mechanic 23411 - Heating, Ventilation And Air Contditioning 21.95 Mechanic (Research Facility) 23430 - Heavy Equipment Mechanic 19.79 23440 - Heavy Equipment Operator 19.26 23460 - Instrument Mechanic 25.87 23465 - Laboratory/Shelter Mechanic 19.71 23470 - Laborer 11.04 23510 - Locksmith 18.99 23530 - Machinery Maintenance Mechanic 24.33 23550 - Machinist, Maintenance 20.81 23580 - Maintenance Trades Helper 14.94 23591 - Metrology Technician I 25.87 23592 - Metrology Technician II 26.99 23593 - Metrology Technician III 28.14 23640 - Millwright 21.53 23710 - Office Appliance Repairer 18.99 23760 - Painter, Maintenance 18.99 23790 - Pipefitter, Maintenance 21.38 23810 - Plumber, Maintenance 20.88 23820 - Pneudraulic Systems Mechanic 20.81 23850 - Rigger 20.81 23870 - Scale Mechanic 18.45 23890 - Sheet-Metal Worker, Maintenance 19.95 23910 - Small Engine Mechanic 18.08 23931 - Telecommunications Mechanic I 23.89 23932 - Telecommunications Mechanic II 24.95 23950 - Telephone Lineman 25.52 23960 - Welder, Combination, Maintenance 20.27 23965 - Well Driller 20.81 23970 - Woodcraft Worker 20.81 23980 - Woodworker 15.04 24000 - Personal Needs Occupations 24570 - Child Care Attendant 10.65 24580 - Child Care Center Clerk 13.27 24610 - Chore Aide 7.35 24620 - Family Readiness And Support Services 13.83 Coordinator 24630 - Homemaker 16.84 25000 - Plant And System Operations Occupations 25010 - Boiler Tender 22.20 25040 - Sewage Plant Operator 18.70 25070 - Stationary Engineer 22.20 25190 - Ventilation Equipment Tender 14.58 25210 - Water Treatment Plant Operator 18.32 27000 - Protective Service Occupations 27004 - Alarm Monitor 16.14 27007 - Baggage Inspector 11.56 27008 - Corrections Officer 19.62 27010 - Court Security Officer 21.18 27030 - Detection Dog Handler 17.90 27040 - Detention Officer 19.62 27070 - Firefighter 20.41 27101 - Guard I 11.56 27102 - Guard II 17.90 27131 - Police Officer I 24.19 27132 - Police Officer II 26.88 28000 - Recreation Occupations 28041 - Carnival Equipment Operator 11.63 28042 - Carnival Equipment Repairer 12.36 28043 - Carnival Equpment Worker 8.51
28210 - Gate Attendant/Gate Tender 13.90 28310 - Lifeguard 12.38 28350 - Park Attendant (Aide) 15.55 28510 - Recreation Aide/Health Facility Attendant 11.35 28515 - Recreation Specialist 17.83 28630 - Sports Official 12.38 28690 - Swimming Pool Operator 17.44 29000 - Stevedoring/Longshoremen Occupational Services 29010 - Blocker And Bracer 20.12 29020 - Hatch Tender 20.12 29030 - Line Handler 20.12 29041 - Stevedore I 18.72 29042 - Stevedore II 21.50 30000 - Technical Occupations 30010 - Air Traffic Control Specialist, Center (HFO) (see 2) 40.33 30011 - Air Traffic Control Specialist, Station (HFO) (see 2) 27.81 30012 - Air Traffic Control Specialist, Terminal (HFO) (see 2) 30.63 30021 - Archeological Technician I 21.56 30022 - Archeological Technician II 25.47 30023 - Archeological Technician III 30.62 30030 - Cartographic Technician 30.62 30040 - Civil Engineering Technician 30.03 30061 - Drafter/CAD Operator I 21.56 30062 - Drafter/CAD Operator II 24.71 30063 - Drafter/CAD Operator III 27.56 30064 - Drafter/CAD Operator IV 33.10 30081 - Engineering Technician I 20.02 30082 - Engineering Technician II 22.48 30083 - Engineering Technician III 25.15 30084 - Engineering Technician IV 31.09 30085 - Engineering Technician V 38.65 30086 - Engineering Technician VI 46.10 30090 - Environmental Technician 29.96 30210 - Laboratory Technician 23.56 30240 - Mathematical Technician 30.62 30361 - Paralegal/Legal Assistant I 22.52 30362 - Paralegal/Legal Assistant II 27.90 30363 - Paralegal/Legal Assistant III 34.12 30364 - Paralegal/Legal Assistant IV 41.27 30390 - Photo-Optics Technician 30.62 30461 - Technical Writer I 23.21 30462 - Technical Writer II 28.38 30463 - Technical Writer III 34.93 30491 - Unexploded Ordnance (UXO) Technician I 25.63 30492 - Unexploded Ordnance (UXO) Technician II 31.01 30493 - Unexploded Ordnance (UXO) Technician III 37.17 30494 - Unexploded (UXO) Safety Escort 25.63 30495 - Unexploded (UXO) Sweep Personnel 25.63 30620 - Weather Observer, Combined Upper Air Or (see 2) 26.35 Surface Programs 30621 - Weather Observer, Senior (see 2) 30.48 31000 - Transportation/Mobile Equipment Operation Occupations 31020 - Bus Aide 11.88 31030 - Bus Driver 17.06 31043 - Driver Courier 14.03 31260 - Parking and Lot Attendant 9.17 31290 - Shuttle Bus Driver 15.28 31310 - Taxi Driver 11.54 31361 - Truckdriver, Light 15.28 31362 - Truckdriver, Medium 18.98 31363 - Truckdriver, Heavy 20.32
31364 - Truckdriver, Tractor-Trailer 20.32 99000 - Miscellaneous Occupations 99030 - Cashier 10.01 99050 - Desk Clerk 11.72 99095 - Embalmer 23.71 99251 - Laboratory Animal Caretaker I 9.83 99252 - Laboratory Animal Caretaker II 10.71 99310 - Mortician 26.44 99410 - Pest Controller 15.80 99510 - Photofinishing Worker 12.62 99710 - Recycling Laborer 16.46 99711 - Recycling Specialist 20.06 99730 - Refuse Collector 14.67 99810 - Sales Clerk 12.66 99820 - School Crossing Guard 10.96 99830 - Survey Party Chief 20.96 99831 - Surveying Aide 14.35 99832 - Surveying Technician 18.13 99840 - Vending Machine Attendant 12.00 99841 - Vending Machine Repairer 14.41 99842 - Vending Machine Repairer Helper 12.31
ALL OCCUPATIONS LISTED ABOVE RECEIVE THE FOLLOWING BENEFITS:
HEALTH & WELFARE: $3.81 per hour or $152.40 per week or $660.40 per month
VACATION: 2 weeks paid vacation after 1 year of service with a contractor or successor; 3 weeks after 5 years, and 4 weeks after 15 years. Length of service includes the whole span of continuous service with the present contractor or successor, wherever employed, and with the predecessor contractors in the performance of similar work at the same Federal facility. (Reg. 29 CFR 4.173)
HOLIDAYS: A minimum of ten paid holidays per year, New Year's Day, Martin Luther King Jr's Birthday, Washington's Birthday, Memorial Day, Independence Day, Labor Day, Columbus Day, Veterans' Day, Thanksgiving Day, and Christmas Day. (A contractor may substitute for any of the named holidays another day off with pay in accordance with a plan communicated to the employees involved.) (See 29 CFR 4174)
THE OCCUPATIONS WHICH HAVE NUMBERED FOOTNOTES IN PARENTHESES RECEIVE THE FOLLOWING:
1) COMPUTER EMPLOYEES: Under the SCA at section 8(b), this wage determination does not apply to any employee who individually qualifies as a bona fide executive, administrative, or professional employee as defined in 29 C.F.R. Part 541. Because most Computer System Analysts and Computer Programmers who are compensated at a rate not less than $27.63 (or on a salary or fee basis at a rate not less than $455 per week) an hour would likely qualify as exempt computer professionals, (29 C.F.R. 541.
400) wage rates may not be listed on this wage determination for all occupations within those job families. In addition, because this wage determination may not list a wage rate for some or all occupations within those job families if the survey data indicates that the prevailing wage rate for the occupation equals or exceeds $27.63 per hour conformances may be necessary for certain nonexempt employees. For example, if an individual employee is nonexempt but nevertheless performs duties within the scope of one of the Computer Systems Analyst or Computer Programmer occupations for which this wage determination does not specify an SCA wage rate, then the wage rate for that employee must be conformed in accordance with the conformance procedures described in the conformance note included on this wage determination.
Additionally, because job titles vary widely and change quickly in the computer industry, job titles are not determinative of the application of the computer professional exemption. Therefore, the exemption applies only to computer employees who satisfy the compensation requirements and whose primary duty consists of:
(1) The application of systems analysis techniques and procedures, including consulting with users, to determine hardware, software or system functional specifications;
(2) The design, development, documentation, analysis, creation, testing or modification of computer systems or programs, including prototypes, based on and related to user or system design specifications;
(3) The design, documentation, testing, creation or modification of computer programs related to machine operating systems; or
(4) A combination of the aforementioned duties, the performance of which requires the same level of skills. (29 C.F.R. 541.400).
2) AIR TRAFFIC CONTROLLERS AND WEATHER OBSERVERS - NIGHT PAY & SUNDAY PAY: If you work at night as part of a regular tour of duty, you will earn a night differential and receive an additional 10% of basic pay for any hours worked between 6pm and 6am.
If you are a full-time employed (40 hours a week) and Sunday is part of your regularly scheduled workweek, you are paid at your rate of basic pay plus a Sunday premium of 25% of your basic rate for each hour of Sunday work which is not overtime (i.e. occasional work on Sunday outside the normal tour of duty is considered overtime work).
HAZARDOUS PAY DIFFERENTIAL: An 8 percent differential is applicable to employees employed in a position that represents a high degree of hazard when working with or in close proximity to ordinance, explosives, and incendiary materials. This includes work such as screening, blending, dying, mixing, and pressing of sensitive ordance, explosives, and pyrotechnic compositions such as lead azide, black powder and photoflash powder. All dry-house activities involving propellants or explosives.
Demilitarization, modification, renovation, demolition, and maintenance operations on sensitive ordnance, explosives and incendiary materials. All operations involving regrading and cleaning of artillery ranges.
A 4 percent differential is applicable to employees employed in a position that represents a low degree of hazard when working with, or in close proximity to ordance, (or employees possibly adjacent to) explosives and incendiary materials which involves potential injury such as laceration of hands, face, or arms of the employee engaged in the operation, irritation of the skin, minor burns and the like; minimal damage to immediate or adjacent work area or equipment being used.
All operations involving, unloading, storage, and hauling of ordance, explosive, and incendiary ordnance material other than small arms ammunition. These differentials are only applicable to work that has been specifically designated by the agency for ordance, explosives, and incendiary material differential pay.
** UNIFORM ALLOWANCE **
If employees are required to wear uniforms in the performance of this contract (either by the terms of the Government contract, by the employer, by the state or local law, etc.), the cost of furnishing such uniforms and maintaining (by laundering or dry cleaning) such uniforms is an expense that may not be borne by an employee where such cost reduces the hourly rate below that required by the wage determination. The Department of Labor will accept payment in accordance with the following standards as compliance:
The contractor or subcontractor is required to furnish all employees with an adequate number of uniforms without cost or to reimburse employees for the actual cost of the uniforms. In addition, where uniform cleaning and maintenance is made the responsibility of the employee, all contractors and subcontractors subject to this wage determination shall (in the absence of a bona fide collective bargaining agreement providing for a different amount, or the furnishing of contrary affirmative proof as to the actual cost), reimburse all employees for such cleaning and maintenance at a rate of $3.35 per week (or $.67 cents per day). However, in those instances where the uniforms furnished are made of "wash and wear" materials, may be routinely washed and dried with other personal garments, and do not require any special treatment such as dry cleaning, daily washing, or commercial laundering in order to meet the cleanliness or appearance standards set by the terms of the Government contract, by the contractor, by law, or by the nature of the work, there is no requirement that employees be reimbursed for uniform maintenance costs.
The duties of employees under job titles listed are those described in the "Service Contract Act Directory of Occupations", Fifth Edition, April 2006, unless…