This document is Attachment 2 to a federal solicitation, which provides technical and quality requirements for the procurement of a Cylinder, Compressed Gas with NSN 8120-015259001. The document specifies the product details, including dimensions, capacity, valve configuration, and treatment/painting requirements. It also references several applicable standards, such as MIL-STD-1916 for sampling and testing, as well as restrictions on the use of mercury or mercury-containing compounds. The related federal contract opportunity is for an HFC Repository, solicitation number SPE4A2-24-R-0015, issued by the Defense Logistics Agency Aviation. The solicitation seeks to procure the described compressed gas cylinders, but no additional details about the opportunity are provided in the attachment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 1 NSN 8120-016199794.pdf | ||
| Attachment 3 Requirements Document.pdf | ||
| HFC - Solicitation Draft.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment #2
NSN: 8120-015259001
CYLINDER, COMPRESSED GAS
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE DLA MASTER LIST OF
TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB AT:
http://www.dla.mil/HQ/Acquisition/O ers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE
MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT
INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
TREATMENT AND PAINTING OF CYLINDERS SHALL BE BY
ANY METHOD/SYSTEM THAT WILL PROVIDE A FINISH
THAT WILL MEET THE REQUIREMENTS OF COMPRESSED
GAS ASSOCIATION TB-17-2000. TESTS 1, 3, 5, 6
AND 8 APPLY.
SAMPLING:
THE SAMPLING METHOD SHALL BE IN ACCORDANCE WITH MIL-STD-1916 OR ASQ H1331, TABLE 1
OR A COMPARABLE ZERO BASED SAMPLING PLAN UNLESS OTHERWISE SPECIFIED BY THE
CONTRACT. IF THE APPLICABLE DRAWING, SPECIFICATION, STANDARD, OR QUALITY ASSURANCE
PROVISION (QAP) SPECIFIES CRITICAL, MAJOR AND/OR MINOR ATTRIBUTES, THEY SHALL BE
ASSIGNED VERIFICAITON LEVELS OF VII, IV AND II OR AQLS OF 0.1, 1.0 AND 4.0 RESPECTIVELY.
UNSPECIFIED ATTRIBUTES SHALL BE CONSIDERED AS MAJOR UNLESS SAMPLING PLANS ARE
SPECIFIED IN APPLICABLE DOCUMENTS. FOR MIL-STD-1916, THE MANUFACTURER MAY USE THE ATTRIBUTE OR VARIABLE INSPECTION METHOD AT THEIR OPTION OR PER THE CONTRACT. MIL- STD-105/ASQ Z1.4 MAY BE USED TO SET SAMPLE LOT SIZE, BUT ACCEPTANCE WOULD BE ZERO
NON-CONFORMANCES IN THE SAMPLE LOT UNLESS OTHERWISE SPECIFIED IN THE CONTRACT.
MERCURY OR MERCURY CONTAINING COMPOUNDS SHALL
NOT BE INTENTIONALLY ADDED TO, OR COME IN DIRECT
CONTACT WITH, ANY HARDWARE OR SUPPLIES FURNISHED
UNDER THIS CONTRACT. EXCEPTION: FUNCTIONAL MERCURY
USED IN BATTERIES, FLUORESCENT LIGHTS, REQUIRED
INSTRUMENTS; SENSORS OR CONTROLS; WEAPON SYSTEMS;
AND CHEMICAL ANALYSIS REAGENTS SPECIFIED BY NAVSEA.
PORTABLE FLUORESCENT LAMPS AND PORTABLE INSTRUMENTS
CONTAINING MERCURY SHALL BE SHOCK PROOF AND CONTAIN
A SECOND BOUNDARY OF CONTAINMENT OF THE MERCURY OR
MERCURY COMPOUND. (IAW NAVSEA 5100-003D).
EMPTY CYLINDER
1.1.1.3.3.3-HEXAFLUOROPROPANE, HFC 236FA
DOT: 4BA300 OR 4BW300 VIRGIN PRODUCT
THE FOLLOWING EXCEPTION IS TAKEN TO A-A-59666: TABLE I, USE CLASS CODE P1 FOR SIZE ONLY. 12.250 IN. O.D. BY 36.0 IN. HGT., 122 LB WATER CAP., 150 LB PRODUCT CAP. WITH FLANGE AND VALVE PROTECTION CAP 3/4-14NGT INLET THD 3 1/8-11UNS-1 VALVE CAP THD WITH DUAL
CONTROL DUAL PORT VALVE.
VALVE NSN: 8120-01-204-0182. VALVE SHALL BE FITTED WITH A 3/8 IN BY 33 IN POLYPROPYLENE EDUCTION TUBE AND CLAMP, WITH THE BOTTOM OF THE TUBE CUT AT TWO 45 DEGREE ANGLES.
FILLED CYLINDER NSN: 6830-01-525-9381.
TREATMENT AND PAINTING: COLOR CODE AND STENCIL PER MIL STD 101B. COLOR ORANGE FOR
REFRIGERANT, STENCIL WITH "1.1.1.3.3.3 HEXAFLUOROPROPANE" ON EACH SIDE OF THE
CYLINDER.