0003 Attachment 1 - Questions.pdf
PDF 103 KB Posted
- Attached to
- Purchase of 60 Inch Wide Format Printers Federal contract opportunity
- Solicitation number
- SP7000-20-Q-1016
- Issued by
- Defense Logistics Agency
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SP7000-20-Q-1016 Amendment 0003.pdf | ||
| SP7000-20-Q-1016 Amendment 0002.pdf | ||
| SP7000-20-Q-1016 Amendment 0001.pdf | ||
| Attachment 3 - Statement of Work (SOW) 60in Wide Printer FINAL WO Comments-02.05.2020.pdf | ||
| Attachment 1 -Equipment Spec 60IN.xlsx | XLSX spreadsheet | |
| Combined Synopsis-Solicitation SP7000-20-Q-1016.pdf | ||
| Attachment 6 -MIL-STD-3060.pdf | ||
| Attachment 8 - Procurex Reverse Auction Instructions.pdf | ||
| Attachment 10 - Question and Comment Form.xlsx | XLSX spreadsheet | |
| Attachment 7 - NGA_ColorTarget_final.pdf | ||
| Attachment 9 - Response to FAR 52.212-3 Offeror Reps and Certs.docx | DOCX document | |
| Attachment 4 - SOW Compliance Form.pdf | ||
| Attachment 5 - 508 Compliance Document.docx | DOCX document | |
| Attachment 2 - CLIN.xlsx | XLSX spreadsheet |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SP7000-20-Q-1016 Attachment 1 - Question and Comment Form Page 1 of 3
Document Description Page # Section/ ParaQuestion/ Comment Proposed Action/ Change
Attachment 1 -Equipment Spec 60IN 1 Line 16
Based on the bulk of the requirements, it appears a traditional, pigment-based ink printer would be the best fit solution, however, there are a couple specifications noted that would otherwise be exclusive to a latex device (entirely different category of device), which would not support the same, higher resolutions/quality as pigment-based ink printers. Would DLA consider lowering the in cartridge/color count to a total of 8? This would align with a pigment-based, ink printer. Yes, minimum 8 inks.
Attachment 1 -Equipment Spec 60IN 1 Line 33
Based on the bulk of the requirements, it appears a traditional, pigment-based ink printer would be the best fit solution, however, there are a couple specifications noted that would otherwise be exclusive to a latex device (entirely different category of device), which would not support the same, higher resolutions/quality as pigment-based ink printers. Can the requirement for two-sided printed be omitted to allow for proposal of a pigment-based, ink printer?
Two sided is required but if only one vendor has this ability it needs to be removed supporting only single sided.
Combined Synopsis-Solicitation SP7000-20-Q-1016 1 Paragraph 11
Can DLA please confirm potential delivey locations, and quantities per location? This will be imperative to attaining the lowest possible shipping costs. Confirm anticipated delivery locations and assocaited quantities.
Richmond, VA, Ft. Bragg, NC, North Island, CA.
Attachment 1 -Equipment Spec 60IN 2 - Min PC-Workstation Specs Line 12
Please confirm that DLA requires that Microsoft Windows Pro be included with the solution. Per Microsoft licensing terms and conditions, even if the DLA Data Management Enterprise/Volume license will be used for loading of the DLA custom image, Windows Pro licensing is required as a foundation to the Enterprise upgrade.
Requirement modified to read "Windows 10 Pro / Windows 10 Pro for Workstation" Requires Windows 10
SP7000-20-Q-1016 Attachment 10 - Question and Comment Form Page 2 of 3
Attachment 1 -Equipment Spec 60IN 2 - Min PC-Workstation Specs Line 20
Is it required that the removable HDD bay/carrier kit be installed into the workstation, or simply that it be included? By Standard, both storage drives be installed internally by the factory, and can be user-removed and reinstalled into the removable carriers. The removable carrier bay is also end-user installable. Custom services can be leveraged to have external bay installed into workstation, and HDDs installed into removable carriers, but will increase cost and lead times.
Adjust requirement to specify whether or not removable HDD carrier/bay must be installed, or simply included.
Removable hard drive carriers installed.
Agency should not have to accomplish any hardware setup.
Attachment 1 -Equipment Spec 60IN 2 - Min PC-Workstation Specs Line 21
Workstation power supplies are usualy auto-ranging allowing for use on European power outlets, though workstations shipped from within the US usually include only a US-standard power cord. Is it required that a European power cord be supplied? Clarification as to whether or not a Eurpoean power cord is required.
No, this is for CONUS and US Territories only.
Attachment 1 -Equipment Spec 60IN 3 - Software RIP Specs Line 13
Is the required "Touch Console Interface" one and the same as the 24" monitor required with the workstation, or is this a second monitor requested, specifically with touch capabilities? Clarification regarding the touch console interface.
Monitor is required for the PC workstation
Attachment 2 - Statement of Work 2 1.3
There is reference to an "Online Folder" and "Scanner" within the SOW, though these items are not included/detailed on the CLIN or Equipment Spec documents. Can you please confirm that there two items are in fact needed, and if so, provide the technical requirements and details for each? Confirm requirement for Online Folder and Scanner, and if required, their associated technical requirements/specifications.
These are accessories that may or may not be ordered. No garuntee that they will. 60-in device does not have aan ONLINE folder and should not be there.
SP7000-20-Q-1016 Attachment 10 - Question and Comment Form Page 3 of 3
Attachment 8
File details come from the government source that posted it. Updated .