SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, & 30 1000049360

1. REQUISITION NUMBER

2. CONTRACT NO. 3. AWARD/EFFECTIVE

DATE

4. ORDER NUMBER

SP4500-16-R-0011

5. SOLICITATION NUMBER 6. SOLICITATION ISSUE

DATE

Amy Corder

a. NAME TELEPHONE NUMBER (No Collect calls)

Phone: 269-961-4187

b. 8. OFFER DUE DATE/

LOCAL TIME

9. ISSUED BY CODE SP4500

DLA DISPOSTION SERVICE - EBS

DLA DISP SVCSS HAZ CONTRACT

74 NORTH WASHINGTON

BATTLE CREEK MI 49037-3092

USA

10. THIS ACQUISITION IS UNRESTRICTED OR SET ASIDE: % FOR:

SMALL BUSINESS

HUBZONE SMALL

BUSINESS

WOMEN-OWNED SMALL BUSINESS

(WOSB) ELIGIBLE UNDER THE WOMEN-OWNED

SMALL BUSINESS PROGRAM

8 (A)

SERVICE-DISABLED

VETERAN-OWNED

SMALL BUSINESS

562211NAICS:

$38,500,000.00SIZE STANDARD:

11. DELIVERYFOR FOB DESTINA-

TION UNLESS BLOCK IS

MARKED

12. DISCOUNT TERMS

13a. THIS CONTRACT IS A

RATED ORDER UNDER

DPAS (15 CFR 700)

13b. RATING

14. METHOD OF SOLICITATION

RFQ IFB RFP

15. DELIVER TO CODE 16. ADMINISTERED BY CODE

17a. CONTRACTOR/ CODE

OFFEROR

FACILITY

CODE

TELEPHONE NO.

18a. PAYMENT WILL BE MADE BY CODE

17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT SUCH ADDRESS IN

OFFER

18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK

BELOW IS CHECKED

19.

ITEM NO.

20.

SCHEDULE OF SUPPLIES/SERVICES

21.

QUANTITY

22.

UNIT

23.

UNIT PRICE

24.

AMOUNT

See Schedule

(Use Reverse and/or Attach Additional Sheets as Necessary)

25. ACCOUNTING AND APPROPRIATION DATA 26. TOTAL AWARD AMOUNT (For Govt. Use Only)

27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1, 52.212-4. FAR 52.212-3 AND 52.212-5 ARE ATTACHED. ADDENDA ARE ARE NOT ATTACHED

27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED

28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN

COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND

DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY

ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED

29. AWARD OF CONTRACT: REF. OFFER

DATED . YOUR OFFER ON SOLICITATION

(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE

SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:

30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a. UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER)

30b. NAME AND TITLE OF SIGNER (Type or Print) 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER (Type or Print) 31c. DATE SIGNED

SEE SCHEDULE

7. FOR SOLICITATION

INFORMATION CALL:

SEE SCHEDULE

STANDARD FORM 1449 (REV. 2/2012)

Prescribed by GSA - FAR (48 CFR) 53.212

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

SEE ADDENDUM

EDWOSB

31 AUG 2016

12:00 PM EDT

25 JULY 2016

Notes to Offerors

1. This contract is a firm-fixed price indefinite delivery/indefinite quantity (IDIQ) contract written as a performance based contract and allows the Contracting Officer to make monetary deductions and/or a negative mark on the Contractor’s Past Performance when an Acceptable Performance Level (APL) is not met.

2. Pricing for containerized waste will largely be based upon a per pound basis.

3. Generators are not responsible for ensuring their containerized wastes sent for disposal via this contract are in Department of Transportation (DOT) shippable packaging.

4. This contract is for various military and Government activities, which may encompass several states. Standard removal timeframe for all sites is 21 calendar days from the date of order issuance. The Contractor agrees that, for those portions of the services provided on a Government installation, the services will be provided during normal hours of operations for the installation, which are available, upon request, from the COR.

Site visits may not be scheduled at the following facilities on Mondays:

• Washington National Guard

5. This contract requires the transportation and disposal of RCRA wastes, non-RCRA wastes, Compressed Gas Cylinders, and Polychlorinated Biphenyls (PCBs).

6. Some CLINs ordered under this contract require the Contractor to provide Certificates of Destruction or Disposal (CD), e.g., certain Demilitarization items and PCB-related wastes. The Contractor is cautioned to closely read all CLIN descriptions where such requirements are indicated. Unless explicitly required and written into this contract, only those CLINs requiring CDs, as described in the Bid Schedule, will require that the Contractor provide a CD.

7. Loading of bulk solids and pumping of bulk liquids may take up to one full work day under certain circumstances and the Government will not allow additional compensation for these tasks unless they exceed one complete 8-hour workday.

8. Publications and attachments applicable to this contract will be made available upon request. It should be noted that during the solicitation and life of this contract, the Government may make changes, additions, or deletions to those listed.

9. The Contractor is cautioned that some requirements for information and plans are required before start of work on this contract, i.e., Section 2.1.4.

10. The Contractor is cautioned that all tank cleaning CLINs will include the team leader, technician(s), and mobilization of all equipment used to perform these services. The Contractor should bid accordingly.

11. Within 14 calendar days of Award, the Contractor shall provide DLA Disposition Services with a list referencing all intended interim and final disposal/recycle facilities by EPA ID number (where applicable) for every base CLIN listed in the Bid Schedule of this contract, see Facility-CLIN Assignment Sheet. The purpose for this is to allow the Government to assign in DSS those facilities that will or might receive those CLINs for treatment, storage, and disposal. If this is not done, Task Orders (TO) cannot be processed in DSS.

12. This contract will have ONE (1) twenty-four (24) month base period.

13. The email address for submission of offers is amy.corder@dla.mil. All offers submitted will receive a confirmation email from the contract specialist. If you do not receive a confirmation email, contact Amy Corder at 269-961-4187 before the close of the solicitation.

14. All questions regarding this solicitation must be received no later than 1200 EST Aug 17th, 2016. Any questions submitted after this date may not be addressed.

15. This solicitation is issued under full and open competition. This solicitation includes the requirement for a SUBCONTRACTING PLAN.

16. Reference projects/contracts and corresponding reference surveys are limited to three projects/contracts considered by the offeror to be the most relevant to the requirements of this solicitation. If more than three projects/contracts with reference surveys are received, the Government will consider the first three projects/contracts received based upon the date and time the reference surveys are received.

17. Note: Zero ($0.00) Unit pricing will NOT be accepted.

18. The Government intends to evaluate offers and award a contract without discussions with offerors. Therefore, the offeror’s initial offer should contain the offeror’s best terms from a price and technical standpoint. However, the Government reserves the right to conduct discussions if later determined by the Contracting Officer to be necessary. The Government may reject any or all offers if such action is in the public interest; accept other than the lowest offer; and waive informalities and minor irregularities in offers received.

CLIN Est Qty Unit Unit Price Amount 6311AA 10 ea -$ 6311BB 10 ea -$ 6311DD 1,960 ea -$ 6311DE 250 ea -$ 6311DF 110 ea -$ 6311DO 10 ea -$ 6311DW 10 ea -$

6311DX

8 ea -$ 6311DZ 3,600 ea -$ 6311EA 730 ea -$ 6311EL 270 ea -$ 6311EM 220 ea -$ 6311EP 100 ea -$ 6311EQ 300 ea -$ 6311EX 1,120 ea -$ 6311FA 10 ea -$ 6311FB 20 ea -$ 6311FG 30 ea -$ 6311FH 80 ea -$ 6311FJ 60 ea -$ 6311FK 4 ea -$ 6312A3 1,200 ea -$ 6312C1

1,200 ea -$ 6312C3 450 ea -$ 6312C5 10 ea -$ 6316DH 10 ea -$ 6316DJ 210 ea -$

6317FB

60 ea -$ 6321 40 ea -$

6321AA

20 ea -$

10 ea -$

6322AA

20 ea -$

10 ea -$

6323AA

20 ea -$ 6330 4 ea -$ 6331 4 ea -$ 6332 4 ea -$ 6333 4 ea -$ 6334 4 ea -$ 6335 4 ea -$ 6335BW 10 ea -$ 6340 2 ea -$ 6341 2 ea -$ 6342 2 ea -$ 6343 2 ea -$ 6344 2 ea -$ 6345 2 ea -$ 6349BC 8 ea -$ 6350 20 ea -$ 6351 10 ea -$

Provide Container, 4ft Fiber Fluorexcent Tube Drum, UN

Provide Container, Steel Drum, New. 55 gl Open Top w/Heavy Bolt Ring. 1 EA = 324 containers and applicable lockable, enclosed watertight storage trailer for up to 30 days.

See CLIN 6389 for trailer rental.

Provide Container, Filter Box/Container Meeting DOT Specifications, approximately 4'6" x 12" diameter.

Provide and Prepare Lab Packs, consisting of small quantity chemicals (55 gl) - The Contractor shall provide a 'Paper Pack', to include appropriate SDSs, spreadsheets, et. to customer five calendar days prior to removal [See 3.7]

Provide and Prepare Lab Packs, consisting of small quantity chemicals (20-30gl) - The Contractor shall provide a 'Paper Pack', to include appropriate SDSs, spreadsheets, et. to customer five calendar days prior to removal [See 3.7]

Provide and Prepare Lab Packs, consisting of small quantity chemicals (5-15 gl) - The Contractor shall provide a 'Paper Pack', to include appropriate SDSs, spreadsheets, et. to customer five calendar days prior to removal [See 3.7]

Expedited Removal - 5 days [See 1.2.11]

6300-6599 SPECIAL SERVICES

Lewis 24 Month Performance Period

Description

Expedited Removal - 3 days [See 1.2.11]

Expedited Removal - 1 day [See 1.2.11]

Expedited Removal - 24 Hours, for Bangor Water [See 3.13]

Expedited Removal - 7 days [See 1.2.11]

Provide Container, Poly Drum, New. 5 gl UN Pail w/Screw Lid

Provide Container, Cubic Yard Box, Meeting DOT Specifications w/o Pallet

Provide Cntainer, Cubic Yard Box, Meeting DOT Specifications with Pallet

Expedited Removal - 15 days [See 1.2.11]

Expedited performance - 1 day [See 1.2.11]

Tank Cleaning/Services – (Above Ground) < 5000 gl. [see 3.2]

Tank Cleaning/Services – (Below Ground) < 5000 gl. [see 3.2]

Expedited performance - 15 days [See 1.2.11]

Expedited performance - 10 days [See 1.2.11]

Expedited performance - 7 days [See 1.2.11]

Expedited performance - 5 days [See 1.2.11]

Expedited performance - 3 days [See 1.2.11]

Provide Container, Steel Drum, Reconditioned. 55 gl Open Top with Heavy Bolt Ring

Provide Container, Steel Drum, Reconditioned. 55 gl Closed Top w/Steel Bungs

Provide Container, Steel Drum, Reconditioned. 30 gl Closed Top w/Steel Bungs

Provide Container, Poly Drum, Reconditioned. 30 gl Closed Top

Provide Container, Steel Drum, New. 85 gl Overpack

Provide Container, Steel Drum, New. 55 gl Open Top w/Heavy Bolt Ring

Provide Container, Steel Drum, New. 55 gl Closed Top w/Steel Bungs

Provide Container, Poly Drum, New. 55 gl Open Top #1 w/Heavy Bolt Ring

Provide Container, 30 gl Poly Drum, New. 1A2/Y1.5/150

Provide Container, Poly Drum, New. 1.25 gl UN 1H2/Y6/S/13, Pail w/Screw Lid

Provide 4 ft. Tube Box (24 Tube Capacity)

Provide 8 ft. Tube Box (24 Tube Capacity)

Provide Container, 5 gl Metal Drum, New, 1H2, with Heavy Bolt Ring.

Provide Container, Poly Drum, New, 5 al, UN3H1/Y1.8/100/15, Closed Top. Dimensions:

14"H x 11"W x 9"D (Jerricans)

Provide Container, Steel Drum, Reconditioned. 30 gl Open Top with Heavy Bolt Ring

Provide Container, Poly Drum, New. 55 gl Closed Top w/Bungs

Provide Container, Poly Drum, New. 30 gl Closed Top

Expedited Removal - 10 days [See 1.2.11]

Provide Container, 30 gl Poly Drum, New UN 1A2/X235/S

Provide Containers, 5 gl Poly Drum, Reconditioned, w/Screw-Top Lid, 1H2/Y27

Provide Container, 8ft Fiber Fluorescent Tube Drum, UN (21" Diameter)

Tank Cleaning/Services - Surcharge for cleaning baffles [3.2]

Repackage Waste Up to 5 Gallon [See 1.2.12]

Repackage Waste Greater than 5 Gallon Up to 55 Gallon [See 1.2.12]

Provide and Prepare Lab Packs, consisting of small quantity chemicals (55 gl) [See 3.7]

Provide and Prepare Lab Packs, consisting of small quantity chemicals (20-30 gl) [See 3.7]

Provide and Prepare Lab Packs, consisting of small quantity chemicals (5-15 gl) [See 3.7]

Lewis 24 Month Performance Period

6352 6 ea -$ 6353ZZ 8 ea -$

6354ZW

8 ea -$

6354ZX

8 ea -$

6354ZZ

8 ea -$ 6372 20 ea -$ 6372AR 30 ea -$ 6375 10 ea -$ 6375AR 30 ea -$

24 ea -$ 6391VT 8 ea -$

6 ea -$ 6400AA 16 ea -$ 6400AB 10 ea -$

14 ea -$ 6402 10 ea -$ 6403 26 ea -$ 6404 10 ea -$

8 ea -$ 6406 4 ea -$ 6408 2 ea -$ 6409 4 ea -$ 6410 2 ea -$ 6411 10 ea -$ 6414 2 ea -$ 6418 10,000 lb -$ 6421 2 ea -$ 6422 2 ea -$ 6423 2 ea -$ 6424 2 ea -$ 6425 2 ea -$ 6500MM 10,000 lb -$

500 ea -$ 6502CD 6 ea -$ 6502SB 10 ea -$ 6502BT 20 ea -$ 6502FR 2 ea -$ 6502FC 4 ea -$ 6502FM 8 ea -$ 6502SP 5 ea -$ 6502TT 4 ea -$ 6502ZD 400 ea -$ 6503 80 ea -$ 6601 2 ea -$

2 ea -$

6609AA

2 ea -$ 6609BB 2 ea -$ 6681 30 ea -$

CLIN Est. Qty. Unit Unit Price Amount

Tank Cleaning/Services - (Above Ground) 10,001 gl up to and including 25,000 gl [See 3.2]

Rental - Storage Containers, trailer holding containers provided under CLIN 6311DX [See 3.6].

Provide Vacuum Truck with Operator [3.15].

Provide Jet Cleaning Service to Clean Storm Drain, 1 EA = 50' [See 3.2]

High Mercury Surcharge [See 2.1.6]

Perform Management Services as described in clause. May include (but is not limited to) preparation of waste documentation, packing, labeling and marking containers, transportation of waste, pumping waste, spill response, reactives stabilization. [See 3.8]

Perform Volatile Organics Analysis (EPA Method 8240)

Perform Wastewater/Non Wastewater Determination in Accordance w/ 40 CFR Part 268.2

Surcharge for Mandatory Incineration [See 3.15]

Perform Test for Asbestos

Determine Benzene, Toluene, Ethylbenzene, and Xylene (BTEX) [See 3.3]

Perform TCLP analysis to determine volatile and semi-volatile organics (D018-D043) [See 3.3]

Perform 96 hour fish bioassay test [See 3.3]

Perform Services, may include repackaging the contents of one compressed gas cylinder that is not DoT transportable (non-inert gas) [See 2.3.3]

Perform Services, may include replacing a valve that is not operable [See 2.3.3]

Pickup/Transportation Services [ See 3.10]

Management Services for ODS removal [See 2.3.4]

Provide Certificates of Disposal [See 2.1.2]

Evaluate unknown compressed gas cylinder[See 2.3.1]

Perform appropriate sampling and analysis to properly identify the gas and complete the waste profile form [See 2.3.2 and 3.3]

Perform Transportation Services [See 3.8]

Perform cleaning services to remove lead from firing range bullet trap [See 3.11]

Perform cleaning services to clean floor at firing range [See 3.11]

Perform cleaning service to clean firing range [See 3.11]

Perform cleaning service to clean firing range [See 3.11]

Perform Analysis to Determine CRESOL (D026)

Perform Polychlorinated Biphenyl (PCB) analysis [See 3.3]

BATTERIES

Description

Tank Cleaning/Services – (Above Ground) 5,001 gl up to and including 10,000 gl [see 3.2]

Tank Cleaning/Services – (Below Ground) 5,001 gl up to and including 10,000 gl [see 3.2]

Management Services - Pumping at Naval Magazine Indian Island [3.17]

Perform F-series solvent analysis to determine EPA waste codes F001-F005 [See 3.3]

Perform Total Organic Halogens analysis [See 3.3]

Tank Cleaning/Services - (Below Ground) 10,001 gl up to and including 25,000 gl [See 3.2]

Provide Storage Container (20cy) [See 3.6.b]

Provide Storage Container (40cy) [See 3.6.b]

Tank Cleaning/Services - (Above Ground) 10,001 gl up to and including 50,000 gl [See 3.2]

Perform Total Petroleum Hydrocarbons (TPH) Analysis [3.3]

Testing unknown compressed gas cylinders [See 3.3]

Perform appropriate analysis to properly identify unknown hazardous property and complete waste profile form [See 3.3 and 3.5]

Perform Hazardous Waste Characteristics Analysis to determine ignitability (D001), corrosivity (D002), reactivity (D003) [See 3.3] Perform total TCLP analysis (D004-D043) [See 3.3]

Perform TCLP Metals analysis to determine 8 TCLP metals (D004-D011) [See 3.3]

Perform TCLP analysis to determine D012-D017 [See 3.3]

Rental - Storage Containers (20cy) Annual Rental [See 3.6.c]

Rental - Storage Containers (40cy) Annual Rental [See 3.6.c]

Prepare Waste Profile Form [See 3.4]

Prepare Waste Profile Form including ADWR form [See 3.4]

Provide Manifest Tracking Log [See 3.9]

BA01C7 42,000

lb

BA03C7 3,000

lb

BA04C7 15,000

lb

BA05C7 10,000

lb

BA06C7 3,000

lb

BA10C7 30,000

lb

BA11C7 500

lb

BA12C7 500

lb

BA13C7 3,000

lb

BA14C7 8,000

lb

BA15C7 2,800

lb

BA98C7 30,000

lb

BA99C7 42,000

lb

CLIN Waste Description CLIN Est. Qty. U/I Unit Price Total Price CY01ME 6 ea -$

CY01M1 120 ea -$

CY01M2 40 ea -$

CY01M3 6

ea

CY02ME 60 ea -$

CY02M1 100 ea -$

CY02M2 6 ea -$

CY02M3 6

ea

CY03ME 12 ea -$

CY03M1 20 ea -$

CY03M2 6 ea -$

CY03M3 6

ea

CY04ME 6 ea -$

CY04M1 6 ea -$

CY04M2 6 ea -$

Lithium Batteries, Mixed Types (Except Red Eye and Stinger), Deactivated if Applicable, may be managed as UW/HW for Recycling or Destruction & Disposal.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002-11.

Magnesium (Mg) Batteries, may be managed as UW/HW for Recycling or Destruction and Disposal.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002, D004-11.

Mercury (Hg) Batteries, may be managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002, D004-11.

Nickel Metal Hydride (NiMh) Batteries, may be managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002, D004-11.

Nickel-Cadmium (NiCd) Batteries, may be managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002, D004-11.

Silver-Zinc (AgZn), Zinc Silver Oxide(ZnAgO), Carbon Zinc, and Zinc Air Batteries, may be managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002, D004-11.

Lithium Batteries, Mixed Types, Deactivated if Applicable, may be managed as UW/HW for Mandatory Recycling.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002-11.

Alkaline Batteries, may be managed as UW for Mandatory Recycling.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002.

CY03 Cylinders, Category 3, for Disposal/Recycle/Reuse.

Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

CY04 Cylinders, Category 4, for Disposal/Recycle/Reuse.

Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp Gas

Compressed Gas Cylinders

CY01 Cylinders, Category 1, for Disposal/Recycle/Reuse.

Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

CY02 Cylinders, Category 2, for Disposal/Recycle/Reuse.

Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

Lithium Ion (Li-Ion) Batteries, may be managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: Universal waste, D002-11.

Lithium Iron Disulfide (Li2FeS2) Thermal Batteries (Red Eye and Stinger), Deactivated, Managed as UW/HW for Recycling or Destruction & Disposal.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002-11.

Lead Acid Batteries, may be managed as UW/HW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: D002, D004-11.

Alkaline Batteries, may be managed as Universal Waste (UW) for Recycling or Direct Landfill Disposal.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002.

Carbon-Zinc (CZn) Batteries, may be managed as UW/HW for Recycling or Disposal.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D002, D004-11.

CY04M3 6

ea

CY05M1 30 ea -$

CY05M2 10 ea -$

CY05M3 6

ea

CY06ME 6 ea -$

CY06M1 6 ea -$

CY06M2 6

ea

CY07M1 6 ea -$

CY07M2 6

ea

CY08ME 6 ea -$

CY08M1 6 ea -$

CY08M2 6 ea -$

CY08M3 6

ea

CY09ME 10 ea -$

CY09M1 10 ea -$

CY09M2 10 ea -$

CY09M3 6

ea

CY10ME 6 ea -$

CY10M1 6 ea -$

CY10M2 6 ea -$

CY10M3 6

ea

CY11 Cylinders, Propane, 20-Lb "Grill Size", for Disposal/Recycle/Reuse. Typically 13" x 17". "ME" = 1 EA Grill-Size Cylinder.

● Physical State: Comp. Gas

● Permissible Waste Codes: D001.

CY11ME 10

ea

CY12ME 300 ea -$

CY12M3 12

ea

CY13 Cartridges, Inert Gas, for Disposal/Recycle/Reuse.

Diameter up to 1", Length up to 6". "ME" = 1 EA Cartridge.

● Physical State: Comp. Gas

● Permissible Waste Codes: N/A.

CY13ME 100

ea

CLIN Waste Description CLIN Est. Qty. U/I Unit Price Total Price PC01 PCB and PCB/RCRA-Mixed Waste Contaminated with or Containing >50 ppm Source, i.e. Debris, Sludge, Water, Leaking Capacitors, Fluids other than Transformer Mineral Oil. Certificate of Destruction Required. [See 2.2].

● Physical State: Various

● Permissible Waste Codes: Characteristic, Listed.

PC01C7 1,000

lb

PC02 PCB Mineral Oil from Transformers, 1-49 ppm PCBs, Non-RCRA. [See 2.2].

● Physical State: Liquid

● Permissible Waste Codes: N/A.

PC02C7 1,000

lb

PC03 PCB Mineral Oil from Transformers, 50-4,000 ppm PCBs. Non-RCRA, Certificate of Recycling or Destruction Required [See 2.2].

● Physical State: Liquid

● Permissible Waste Codes: N/A.

PC03C7 1,000

lb

CY12 Cartridges, Flammable Gas, AVGAS, Gas/Diesel Starting, for Disposal/Recycle. Diameter up to 3", Length up to 10". Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: D001.

Polychlorinated Biphenyls (PCBs)

CY10 Cylinders, Acetylene, for Recycle/Reuse.

Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: D001.

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

CY05 Cylinders, Category 5, for Disposal/Recycle/Reuse.

Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

Cylinders, Category 6, for Disposal/Recycle/Reuse.

Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

CY07 Cylinders, Category 7, for Disposal/Recycle/Reuse.

Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

CY06

Cylinders, Category 8, for Disposal/Recycle/Reuse.

Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.

CY08

CY09 Cylinders, Acetylene, Contains Asbestos, for Purge and Landfill. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: D001.

PC04 PCB Mineral Oil , Water, Other Fluids, >4,000 ppm PCBs. Certificate of Destruction Required [See 2.2].

● Physical State: Liquid

● Permissible Waste Codes: Characteristic, Listed.

PC04C7 1,000

lb

PC05 PCB Oil-Filled Capacitors/Equipment other than Transformers, 1-49 ppm PCBs, Non-RCRA [See 2.2].

● Physical State: Various

● Permissible Waste Codes: N/A.

PC05C7 1,000

lb

PC06 PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, >50 ppm PCBs, Non-RCRA, Certificate of Recycling or Destruction Required. [See 2.2].

● Physical State: Various

● Permissible Waste Codes: N/A.

PC06C7 3,000

lb

PC07 PCB Oil-Filled Transformers, 1-49 ppm PCBs, Non- RCRA. [See 2.2].

● Physical State: Various

● Permissible Waste Codes: N/A.

PC07C7 3,000

lb

PC08 PCB Oil-Filled Transformers, >50 ppm PCBs.

Certificate of Recycling or Destruction Required. [See 2.2].

● Physical State: Various

● Permissible Waste Codes: N/A.

PC08C7 1,000

lb

PC09 PCB Solids/Debris Contaminated with 1-49 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Non- RCRA. [See 2.2].

● Physical State: Solid

● Permissible Waste Codes: N/A.

PC09C7 1,000

lb

PC10 PCB Solids/Debris Contaminated with >50 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Non- RCRA. Certificate of Disposal, Recycling or Destruction Required. [See 2.2].

● Physical State: Solid

● Permissible Waste Codes: N/A.

PC10C7 1,000

lb

CLIN Est Qty Unit Unit Price Amount 9101 76,000 lbs -$ 9101RR 300 lbs -$ 9102 188,000 lbs -$ 9102RR 30,000 lbs -$ 9104 124,000 lbs -$ 9104BA 500 lbs -$ 9104FL 1,000 lbs -$ 9105 25,000 lbs -$ 9106 233,000 lbs -$ 9106RR 30,000 lbs -$ 9107PL 38,000 lbs -$ 9108CD 1,000 lbs -$

CLIN Est Qty Unit Unit Price Amount 9201 13,400 lbs - 9202 34,000 lbs - 9205 400 lbs - 9206 72,000 lbs - 9208CD 100 lbs -

CLIN Est Qty Unit Unit Price Amount 9301 650 lbs - 9302 1,050 lbs - 9304 6,800 lbs - 9304BA 3,500 lbs - 9305 13,250 lbs - 9306 Bulk Liquids (pumpable), Otto fuel 68,800 lbs -

Containerized Solids, Fully Drained Fuel Filters, Mandatory Recycling [See 2.4.2]

Small Containers [See 1.2.8.3]

Containerized Liquids/Multi-phase

Containerized Solids

Containerized Solids, OBA canisters

Aerosols

9101-9199 IGNITABLE WASTES [40 CFR 261.21] D001

Description

9200-9299 CORROSIVE WASTES [40 CFR 261.22] D002

9300-9399 REACTIVE WASTES [40 CFR 261.23] D003

Small Containers [See 1.2.8.3]

Containerized Liquids/Multi-phase

Aerosols

Bulk Liquids (pumpable)

Chemical Defense Equipment (CDE) Kits, liquid or solid [See 2.5.2]

Description

Description

Small Containers [See 1.2.8.3]

Small Containers, Fuels Blending [See 1.2.8.3 & 2.4.2]

Containerized Liquids/Multi-phase

Containerized Liquids/Multi-phase, Fuels Blending [See 2.4.2]

Containerized Solids

OBA/EEBD (Oxygen Cylinder)

Aerosols, Flammable

Bulk Liquids, Pumpable

Bulk Liquids, Pumpable, Fuels Blending

Bulk Solids, packed in large (>119 gl) boxes packed by generator

Chemical Defense Equipment (CDE) Kits, liquid or solid [See 2.5.2]

9308CD 100 lbs -

CLIN Est Qty Unit Unit Price Amount 9401 7,500 lbs - 9401MM 1,000 lbs - 9402 172,500 lbs - 9402RR 6,000 lbs - 9402MA 1,000 lbs - 9402ME 3,000 lbs - 9402MF 3,000 lbs - 9402MM 200 lbs - 9404 250,000 lbs - 9404FR 30,000 lbs - 9404FT 87,000 lbs - 9404MD 5,000 lbs - 9404MM 3,000 lbs - 9404RR 6,000 lbs - 9405 100 lbs - 9406 197,000 lbs - 9407 418,000 lbs - 9407BT 11,200 lbs - 9407DB 2,700 lbs - 9407PL 9,000 lbs - 9408CD 15,500 lbs -

CLIN Est Qty Unit Unit Price Amount 9501 2,000 lbs - 9501RR 2,000 lbs - 9502 104,000 lbs - 9502RR 5,600 lbs - 9504 164,000 lbs -

CLIN Est Qty Unit Unit Price Amount 9532 1,000 lbs - 9534 3,150 lbs -

CLIN Est Qty Unit Unit Price Amount 9701 10,000 lbs - 9701PI 88,000 lbs - 9702 1,000 lbs - 9704 1,000 lbs - 9708CD 1,000 lbs -

CLIN Est Qty Unit Unit Price Amount 9751 1,600 lbs - 9751RR 500 lbs - 9752 500 lbs - 9752RR 500 lbs - 9754 400 lbs - 9755 400 lbs - 9758CD 200 lbs -

CLIN Est Qty Unit Unit Price Amount 9801 63,000 lbs -$ 9801PI 400 lbs. -$ 9802 178,000 lbs -$ 9802RR 1,000 lbs -$ 9804 200,000 lbs -$ 9805 100 lbs -$ 9806 180,000 lbs -$ 9807 80,000 lbs -$ 9807PL 30,000 lbs -$

Small Containers, Pharmacy Waste for Mandatory Incineration [See 1.2.8.3 & 3.14]

Containerized Liquids/Multi-phase, Toxic Solvents, Required Recycling [See 2.4.2]

Containerized Liquids/Multi-phase, Manufactured Articles containing >260ppm Mercury

Containerized Liquids/Multi-phase, Elemental Mercury

Containerized Liquids/Multi-phase, Organic Compounds having >260ppm Mercury

Containerized Liquids, Inorganic Compounds containing >260ppm Mercury

Containerized Solids, lead bullets, mandatory recycling

Chemical Defense Equipment (CDE) Kits, liquid or solid [See 2.5.2]

9500-9529 SPENT SOLVENT WASTES [40 CFR 261.31] F001-F005

9530-9559 ELECTROPLATING RELATED WASTES [40 CFR 261.31] F006-12,19

9700-9729 ACUTELY HAZARDOUS WASTES [40 CFR 261.33] P- LISTED

9750-9799 TOXIC WASTES [40 CFR 261.33] U - LISTED

Chemical Defense Equipment (CDE) Kits, liquid or solid [See 2.5.2]

Chemical Defense Equipment (CDE) Kits, liquid or solid [See 2.5.2]

Containerized Solids

Containerized Solids, Fluorescent Light Tubes,HID lamps, mercury vapor, metal halide

9400-9499 TOXICITY CHARACTERISTIC WASTES [40 CFR 261.24] D004-43

Aerosols

Bulk Liquids (pumpable)

Bulk Solids

Description Small Container [See 1.2.8.3]

Small Container, High Mercury [See 1.2.8.3]

Containerized Liquids/Multi-phase

Containerized Solids, Debris meeting definition of 40 CFR 268.2, >260ppm Mercury

Containerized Solids and/or Liquids, Inorganic Compounds containing >260ppm Mercury

Containerized Solids, Required Recycling

STATE REGULATED WASTE

Bulk Solids, BondCote Tents/Fabrics [See 2.5.4]

Bulk Solids, Light Weight [See 2.1.5.1]

Bulk Solids, packed in large (>119 gl) boxes by generator

Small Containers [See 1.2.8.3]

Containerized Liquids/Multi-phase

Containerized Liquids/Multi-phase, Solvents for recycling (concentration individual

Containerized Solids

Description

Description

Description

Description Containerized Liquids/Multi-phase Containerized Solids

Small Containers

Pharmacy Waste Mandatory Incineration [See 3.14]

Containerized Liquids/Multi-phase

Containerized Solids

Chemical Defense Equipment (CDE) Kits, liquid or solid [See 2.5.2]

Small container, required recycling [See 1.2.8.3]

Description

Small Containers

Small Containers, Fuels Blending [See C.2.4.2]

Containerized Liquids/Multi-phase

Containerized Liquids/Multi-phase, Fuels Blendable [See 2.4.2]

Containerized Solids

Aerosols

Small Containers [See 1.2.8.3]

Containerized Liquids/Multi-phase

Containerized Liquids/Multi-phase, Fuels Blending [See 2.4.2]

Containerized Solids

Aerosols

Bulk Liquids (pumpable)

Bulk Solids

Bulk Solids, packed in large (>119 gl) boxes by generator

9808CD 500 lbs -$

CLIN Est Qty Unit Unit Price Amount 9901 45,000 lbs -$ 9901LP 5,000 lbs -$ 9901RR 3,000 lbs -$ 9902 133,000 lbs -$ 9902AF 62,000 lbs -$ 9902FA 88,000 lbs -$ 9902LP 5,000 lbs -$ 9902RR 156,000 lbs -$ 9904 450,000 lbs -$ 9904AS 5,000 lbs -$ 9904BX 200,000 lbs -$ 9904CM 5,500 lbs -$ 9905 100 lbs -$ 9906 1,336,000 lbs -$ 9906AF 50,000 lbs -$ 9906RR 50,000 lbs -$ 9907 158,000 lbs -$ 9907PL 150,000 lbs -$ 9908CD 6,750 lbs -$

Total Estimated Price (24 Month Performance Period) Total

Bulk Liquids (pumpable) Multi-phase, Fuels Blending [See 2.4.2]

9900-9999 NON RCRA, NON STATE REGULATED WASTES

Chemical Defense Equipment (CDE) Kits, liquid or solid [See 2.5.2]

Chemical Defense Equipment (CDE) Kits, liquid or solid [See 2.5.2]

Description

Aerosols

Bulk Liquids (pumpable)

Bulk Liquids, Antifreeze for required recycling [See 2.4.2]

Bulk Solids

Bulk Solids, packed in large (>119 gl) boxes by generator

Containerized Solids, Asbestos

Containerized Solids, BDUs requiring incineration [See 2.5.3]

Containerized Solids, Passive Countermeasure System Material [See 2.5.1]

Small Containers

Small Containers, Latex Paint

Containerized Liquids/Multi-phase

Containerized Liquids/multi-phase, Anti-freeze for mandatory recycling [See 2.4.2]

Containerized LiquidsMulti-phase, Oil Filters (drained w/some oil remaining) [See 2.4.2]

Containerized Liquids/Multi-phase, Latex Paint [See 2.4.2]

Containerized Liquids/Multi-phase, Fuels Blending [See 2.4.2]

Containerized Solids

Small containerized, Required Recycling

Pick Up Points The Contractor shall perform in and around the following sites:

Fleet and Industrial Supply Center Manchester Fuel Department 7501 Beach Drive East Port Orchard, WA 98366

Mobile Inshore Undersea Warfare Unit 10 5909 North Cotter Circle Portland, OR 97217

Fort Lawton (includes AMSA 79 and OMS) 4555 Texas Way W Seattle, WA 98199

Pier 23 US Army Reserve Center / AMSA 137 401 E. Alexander Avenue, Pier 23 Tacoma, WA 98421

Hopper U.S. Army Reserve Center

130 ½ 228th Street SW Bothell, WA 98021

Oswald U.S. Army Reserve Center 1110 Rainer Avenue Everett, WA 98201

Kandle Hall U.S. Army Reserve Center 5119 Portland Avenue Tacoma, WA 98404

Renton U.S. Army Reserve Center

14631 SE 192nd Street Renton, WA 98058

Nuttal U.S. Army Reserve Center

921 South 4th Ave SW

Tumwater, WA 98512

Wagenaar U.S. Army Reserve Center 1101 E. Ainsworth Street Pasco, WA 99301

Sharff Hall U.S. Army Reserve Center 8801 N. Chatauqua Avenue Portland, OR 97217

Webb Hall U.S. Army Reserve Center 1355 Chambers Street Eugene, OR 97402

NMCRC Eugene

1520 West 13th Avenue Eugene, OR 97402

Mann U.S. Army Reserve Center / AMSA 80 4155 N. Market Street Spokane, WA 99207

Walker U.S. Army Reserve Center N 3800 Sullivan Road Spokane, WA 99216

Camp Withycombe 10101 SE Clackamas Rd Clackamas, OR 97015

Camp Rilea 91426 Rilea McCarter Rd Warrenton, OR 97416

Central Oregon Unit Training Equipment Site

(COUTES)

2899 E. Hwy 126 Redmond, OR 97756

Salem OMD 1776 Militia Way SE

Salem, OR 97309

Medford FMS 1701 S. Pacific Hwy Medford, OR 97501

Portland FMS

10000 NE 33rd Drive Portland, OR 97211

La Grande FMS 64082 Airport Ln La Grande, OR 97850

Lebanon FMS 36646 Oak Drive Lebanon, OR 97355

U.S. Coast Guard - Seattle Integrated Support Command 1519 Alaskan Way South Seattle, WA 98134

659th Engineering Company

Construction Support 3800 North Sullivan Road Spokane, WA 99216

OMS #2

426 A Street East Ephrata, WA

OMS #10

2408 North Government Way Spokane, WA

Army Aviation Support Facility #2 8700 West Electric Road, Bldg. 2504 Geiger Field Spokane, WA

Port of Tacoma Tacoma, WA

Samson Tug and Barge Seattle, WA

Camp Murray Air National Guard

254th RHS 109 Engineer Dr.

Camp Murray, WA 98430-5022 (Tillicum, WA across I-5 from Ft. Lewis)

Seattle Air National Guard 6736 Ellis Avenue S.

Seattle, WA 98108-3597

Paine Field Air National Guard

2701 12th Street, S.W.

Everett, WA 98032 (South End of Paine Field)

Oregon ANG Base 6801 NE Cornfoot Road Portland, OR 97218-2797

Hubert Hall U.S. Army Reserve Center 701 N. Columbus Avenue Medford, OR

Camp Wesley Harris Naval Reservation 4673 Seabeck Highway, NE Bremerton, WA 98312

Naval Base Kitsap - Bangor Bldg 6079 Silverdale, WA 98315

Naval Ordnance Center Pacific Division Detachment 100 Indian Island Road, Bldg. 300

Port Hadlock, WA 98339

Umatilla Chemical Depot 78798 Ordnance Road, Bldg. 203 Hermiston, OR 97838

Military Traffic Management Command (MTMC) Pierce County Terminal Tacoma, WA

Navy and Marine Corps Reserve Center 1100 Alexander Ave Tacoma, WA 98421

Naval & Marine Corps Reserve Center Portland, OR

Detach Phase Engineer Renovation Alteration Aircraft Carrier Warehouse 8 Auburn, WA

USAF Coos Bay Head ANG Station 4300 Coos Head Rd Coos Bay, OR 97420-2978

Yakima Air Force Reserve Center 1708 Tahoma Avenue Yakima, WA

U.S. Naval Hospital 1 Boone Road, Bldg. HP20 Bremerton, WA 98312

Naval Undersea Warfare Center Bradley Rd, Bldg. 1051 Keyport, WA 98345

Naval Station Everett 2150 Nimitz Ave.

Bldg 2150

Everett, WA 98207

Pacific Beach Resort

108 N. 1st Street Pacific Beach, WA 98571

Smokey Point Support Complex

13900 45th Avenue NE Marysville, WA 98271

Naval Radio Station Jim Creek 21027 Jim Creek Road, Bldg. 75 Arlington, WA 98223

Yakima U. S. Training Center One-Stop HW Yard, Bldg 450 Yakima, WA 98901

MATES/ OMS #8

1211 Firing Center Road Yakima Training Center, Bldg. 951 Yakima, WA

Ashland Readiness Center 1420 East Main Street Ashland, OR 97520

Bend AFRC 875 SW Simpson Avenue Bend, OR 97702

Cottage Grove Readiness Center 628 Washington Street Cottage Grove, OR 97424

Klamath Falls Readiness Center 2501 Shasta Way Klamath Falls, OR 97601

Lake Oswego Readiness Center

1915 S. Shore Blvd.

Lake Oswego, OR 97034

Lebanon Readiness Center 350 Maple Street Lebanon, OR 97355

McMinnville Readiness Center 333 Armory Way McMinnville, OR 97128

McNary Field 1921 Turner Road SE Salem, OR 97302

Pendleton Armory

2100 NW 56th Drive Pendleton, OR 97801

116th Air Control Squadron

Route 2 Box 499 Warrenton, OR 97146

Vancouver Barracks Vancouver, WA 98661

BMA – 10

400 E Fifth St Vancouver, WA 98661

Sears U.S. Army Reserve Center 2731 SW Multnomah Blvd.

Portland, OR 97219

Pendleton U.S. Army Reserve Center 141 Tipp Road Yakima, WA

NAS Whidbey Island Seaplane Base/Env. Affairs Dept., Bldg. 113

1155 W. Lexington St.

Oak Harbor, WA 98378

NWS Training Facility Bombing Range Rd.

Boardman, OR 97818

NAS Whidbey Island Forestall Road, Bldg. 2757 Oak Harbor, WA 98278

NAS Whidbey Island Maui Ave, Bldg. 60 Oak Harbor, WA 98278

DLA, Disposition Services Site Lewis Bldg 9674 Fort Lewis, WA 98433

Kingsley Field Air National Guard Klamath Falls, OR

U.S. Army Recruiting Battalion Seattle 4735 E. Marginal Way S.

Seattle, WA 98134

Grand Armory Grandview, WA

Buckley Armory Buckley, WA

Kent Armory Kent, WA

Moses Lake Armory Moses Lake, WA

Corps of Engineers, McNary Dam PO Box 1230, 82925 Devore Rd.

Umatilla, OR 97882

Camp Bonneville 23201 N.E. Pluss Road Vancouver, WA 98682

Tigard FMS 6700 SW Oak Tigard, OR 97223

Salem AASF 1921 Turner Rd SE Salem, OR 97301

Salem FMS 1025 Airport Rd SE

Pendleton AASF

2110 NW 56th Pl Pendleton, OR 97801

Springfield FMS 3110 Pierce Parkway Springfield, OR 97477

Albany Readiness Center 3800 Knox Butte Rd Albany, OR 97321

Baker City Readiness Center 1640 Campbell St Baker City, OR 97814

BIAK Training Center 8540 SW Cavalry Way Powell Butte, OR 97753

Burns Readiness Center 619 S Fairview St Burns, OR 97720

Camp Adair 39432 Rifle Range Rd Corvallis, OR 97330

Central OR Readiness Center (CORC) 3852 SW Tom McCall Rd Prineville, OR 97754

Coos Bay Readiness Center 255 N Norman Ave Coos Bay, OR 97420

Corvallis Readiness Center 1100 NW Kings Blvd Corvallis, OR 97330

Dallas Readiness Center 817 SW Church St Dallas, OR 97338

Eugene Readiness Center 2515 Martin Luther King Jr Blvd Eugene, OR 97401

Forest Grove Readiness Center 2950 Taylor Way Forest Grove, OR 97116

Grants Pass Readiness Center 666 Brookside Blvd Grants Pass, OR 97526

Gresham Readiness Center 500 NE Division St Gresham, OR 97030

Hermiston Readiness Center 900 SE Columbia Dr Hermiston, OR 97838

Hillsboro Readiness Center

848 NE 28th Ave Hillsboro, OR 97123

Hood River Readiness Center

1520 12th St Hood River, OR 97031

Jackson Readiness Center 6255 NE Cornfoot Rd Portland, OR 97218

Klamath Falls Readiness Center 404 Rand Way Klamath Falls, OR 97601

La Grand Readiness Center

404 12th Ave La Grande, OR 97850

Lake Oswego Readiness Center 1915 South Shore Blvd Lake Oswego, OR 97034

McMinnville Readiness Center 333 Armory Way McMinnville, OR 97128

Milton-Freewater Readiness Center 149 S Main St Milton-Freewater, OR 97862

Newport Readiness Center 541 SW Coast Hwy Newport, OR 97365

Ontario Readiness Center

720 NW 8th Ave Ontario, OR 97914

Redmond Readiness Center 822 Highland Ave Redmond, OR 97756

Roseburg Readiness Center 111 NW General Ave Roseburg, OR 97470

RTI

701 Monmouth Ave Monmouth, OR 97361

Salem Armory

2310 17th St NE Salem, OR 97303

Salem ARC 3225 State St Salem, OR 97301

St. Helens Readiness Center

474 South 7th St St. Helens, OR 97051

The Dalles Readiness Center 713 Webber St The Dalles, OR 97058

Woodburn Readiness Cetner 1630 Park Ave Woodburn, OR 97071

USN Jackson Park Naval Housing 1400 Farragut Ave Bremerton, WA 98314-5001

Salem Reserve Center 775 Airport Rd SE

McCarter U.S. Army Reserve Center 1601 W. Wyoming Ave.

Hayden Lake, ID 83835

DLA, Disposition Services Site Fairchild 120 N. Foulois Fairchild AFB, WA 99011

Fairchild AFB 90-Day Site, Bldg 2411 550 N. Depot Ave.

Fairchild AFB, WA 99011

Battery A, 1st Battalion, 14th Marine Reserves

5101 N. Assembly Street Spokane, WA 99206

Mobile Inshore Undersea Warfare Unit 102 5101 N. Assembly Street Spokane, WA 99206

Washington ANG 242 Combat Communications Squadron Spokane International Airport Spokane, WA

Table of Contents

0. PERFORMANCE WORK STATEMENT

1. REMOVAL

1.1 PRE-REMOVAL

1.1.1 PERMIT/SPECIAL REQUIREMENTS

1.1.2 SHIPPING DOCUMENTATION

1.1.3 NOTIFICATIONS

1.1.4 TRAILER SECURITY, PADLOCKS

1.1.5 HOURS OF OPERATION

1.1.6 PUBLIC AFFAIRS COORDINATION

1.1.7 RAPID GATE SECURITY

1.1.8 ENVIRONMENTAL MANAGEMENT SYSTEM

1.2 REMOVAL

1.2.1 SPILL RESPONSIBILITY

1.2.2 SEGREGATION OF HAZARDOUS WASTE

1.2.3 STATEMENT ON CONTAINERS

1.2.4 GOVERNMENT EQUIPMENT & PERSONNEL

1.2.5 TREATMENT OF HAZARDOUS WASTE ON GOVERNMENT

FACILITY

1.2.6 LOADING

1.2.7 WEIGHING OF ITEMS

1.2.8 DEFINITIONS, BULK & CONTAINERIZED WASTE

1.2.9 BULK LIQUID PUMPING

1.2.10 BULKING & CONSOLIDATION

1.2.11 CHARGES FOR EXPEDITES

1.2.12 PACKAGING FOR COMPLIANCE

1.3 POST REMOVAL

1.3.1 RETURN OF SHIPPING DOCUMENTATION

2. DISPOSAL/RECYCLING

2.1 RCRA/NON-RCRA ITEMS

2.1.1 TSCA/RCRA/NON-RCRA/STATE/NON-STATE REGULATED ITEMS

2.1.2 CERTIFICATES OF DISPOSAL, DESTRUCTION, & RECYCLING

2.1.3 DETAILED ANALYSIS

2.1.4 ALTERNATE DOCUMENTATION OPTION FOR FUELS

BLENDING, ANTIFREEZE RECYCLING, BATTERY

RECYCLING/RECLAMATION, & FLUORESCENT LIGHT

TUBES & HIGH INTENSITY DISCHARGE LAMPS

2.1.5 RESERVED

2.1.6 EMPTY CONTAINERS

2.1.7 DISPOSAL FOR HIGH LEVEL MERCURY

2.2 DISPOSAL OF PCB, PCB-RELATED WASTE

2.3 COMPRESSED GAS CYLINDERS

2.3.1 EVALUATION/IDENTIFICATION OF CYLINDERS

2.3.2 ANALYSIS TO IDENTIFY CYLINDER CONTENTS

2.3.3 RECONTAINERIZATION/REPLACEMENT OF VALVES

2.3.4 ODS REMOVAL

2.4 RECYCLING

2.4.1 RECYCLE/RECOVERY/RE-USE/RECLAIM

2.4.2 COMMODITY SPECIFIC RECYCLING REQUIREMENTS

2.5 DEMILITARIZATION

2.5.1 DEMILITARIZATION OF SUBMARINE TILES

2.5.2 OTHER MILITARY ITEMS

2.5.3 DEMILITARIZATION OF MILITARY CLOTHING

3. SPECIAL SERVICES

3.1 RESERVED

3.2 TANK & WASH RACK CLEANING

3.3 PERFORM ANALYSIS

3.4 PREPARE WASTE PROFILE SHEET

3.5 IDENTIFY UNKNOWN WASTE STREAMS & PREPARE WASTE

PROFILE SHEETS

3.6 PROVIDE ROLLOFF AND STORAGE CONTAINERS & RENTAL CHARGES

3.7 LAB PACKING SERVICES

3.8 MANAGEMENT SERVICES

3.9 PROVIDE MANIFEST TRACKING LOG

3.10 PICKUP/TRANSPORTATION SERVICES

3.11 CLEANING OF FIRING RANGE AREAS

3.12 RESERVED

3.13 BANGOR WATER

3.14 MANDATORY INCINERATION FOR PHARMACEUTICAL WASTE

3.15 PROVIDE VACUUM TRUCK AND OPERATOR

3.16 DISPOSAL SURCHARGE FOR MANDATORY INCINERATION

3.17 OFF HOURS PUMPING OF SUBMARINES

4. ACCEPTABLE PERFORMANCE LEVELS

5. USE OF FACILITIES AND TRANSPORTERS

5.1 QUALIFIED FACILITIES

5.2 QUALIFIED TRANSPORTERS

5.3 ADDITIONAL TSDFS AND TRANSPORTERS

6. ADDITIONAL REQUIREMENTS

6.1 INDEMNIFICATION

6.2 REPORTING REQUIREMENTS

6.3 PACKING, MARKING AND LABELING

6.4 PLACES OF GOVERNMENT INSPECTION

6.5 CONTRACTOR REPRESENTATIVE

6.6 INCIDENTAL FEES

6.7 MANPOWER REPORTING REQUIREMENTS

7. PERIOD OF PERFORMANCE- INCLUDING DISPOSAL AND REMOVAL

8. DOCUMENTATION REQUIREMENTS, DLA DISPOSITION SERVICES ACCEPTANCE,

INVOICING AND TRACKING

8.1 SUBMISSION OF DOCUMENTATION TO FACILITATE ACCEPTANCE FOR

PAYMENT

8.1.1 ACCEPTANCE AND INVOICING

8.2 POST-PAYMENT TRACKING

8.3 REMEDIES FOR NON-COMPLIANCE

0. PERFORMANCE WORK STATEMENT

a. The Government agrees that all items placed on a Task Order (TO) on this contract will be accompanied by documentation and markings that comply with all applicable local, state, and federal laws and regulations relating to the generation and storage of waste.

b. The Contractor agrees to provide all services necessary for the transportation, final treatment, disposal, and/or recycling of the items listed in the schedule in accordance with (IAW) all local, state, and federal laws and regulations, and the terms and conditions of this contract.

These services shall include all necessary personnel, including applicable Subcontracts, labor, transportation, equipment, and the compilation and submission of all documentation required by this contract. All items, regardless of the condition, are being discarded by the Government and will require recycling or disposal as identified via the ordered Contract Line Item Number

(CLIN).

1. REMOVAL

The requirements for removal of wastes under this contract are divided into three main phases:

Pre-Removal (1.1), Removal (1.2), and Post-Removal (1.3). The Contractor and their Sub-contractors must perform at all times in a prudent, conscientious, safe, and professional manner.

The Contractor shall ensure that its agents, employees, and Sub-contractors involved in handling and packaging the hazardous waste be trained for the level of expertise required for the proper performance of the task and, in particular, in the areas of chemical incompatibility, general first aid procedures, and spills. Handling equipment and Personal Protective Equipment (PPE) shall be provided by the Contractor, unless otherwise stated, and must be appropriate to ensure safe handling of the hazardous waste. While operating on a Department of Defense (DOD) facility, the Contractor may be required to use forklifts. Contractor-operated forklifts must meet specifications listed in the applicable permit. The Contractor agrees that all personnel and equipment used in the performance of this contract are subject to safety inspections by Government personnel while on federal property.

1.1 PRE-REMOVAL

1.1.1 PERMIT/SPECIAL REQUIREMENTS

a. The Contractor shall, without additional expense to the Government, be responsible for paying all fees, preparing or obtaining any necessary licenses, permits, notifications, waste profiles, or reports, which result from a Contractor’s transportation, recycling, or disposal decision. This includes acquiring any required permits or registrations necessary to operate on any installation listed in this contract and completing the Notification of Regulated Waste Activity form for the Generator(s) of hazardous waste to sign and file with the applicable state regulators for waste disposal. This includes signing (on behalf of the Government) waste profiles requested by Treatment, Storage, and Disposal Facilities (TSDF). All Contractor-signed waste profile sheets shall be written for the actual wastestream using the Generator’s profile for backup documentation. All Generator forms or other means of notifications including correspondence with federal or state agencies on behalf of a Generator must be coordinated with and concurred with by the affected Generator prior to submission to any federal or state agency. A copy of all forms and relevant documentation, including correspondence shall be provided to the COR.

b. The Contractor may be required to attend special training, seminars, instructions, classes, safety orientations, etc., provided by the Government or to provide information to perform work or gain access to the installation. Example: pass and ID requirements, antiterrorist training, Environmental Management System (EMS) policies, and/or forklift training.

c. The Contractor and any Sub-contractor(s) shall use only the facilities and transporters currently (at the time) listed in the DLA Disposition Services Qualified Facilities List (QFL) and Qualified Transporters List (QTL), see Section 5.

d. Any import or export shipment outside the United States must comply with all international agreements and all applicable foreign laws. If the Contractor will be exporting directly from the DOD activity, the Contractor is required to provide a current copy of the Acknowledgment(s) of Consent to the Contracting Officer Representative (COR) with the shipping documentation IAW Section 1.1.2.

e. The Contractor may not ship waste outside of the United States to circumvent Environmental Protection Agency (EPA) Land Disposal Restrictions (LDR) unless domestic treatment capability does not exist or domestic facilities are unable to meet EPA LDR requirements within the United States (e.g., Lithium batteries). High level mercury (>260 mg/kg) will not be exported outside the United States.

1.1.2 SHIPPING/DISPOSAL DOCUMENTATION

a. All references to manifests in this provision refer to the appropriate shipping papers.

Prior to removal from a site identified as a pickup point in this contract, completed copies of all manifests and LDR notifications shall be furnished to the Disposition Services Field Activity coordinating the waste disposal. All documentation shall be clearly marked with the name of the servicing Disposition Services Field Activity in addition to the Generator, contract, and TO number, as applicable. Emergency response information and 24-hour emergency phone numbers shall be listed on the manifest. If blocks for emergency information are not provided, this information shall be placed in the upper right-hand corner of each document.

b. The Contractor shall provide the COR or the Contracting Officer Technical Representative (COTR) with a copy of the completed form(s) for review by the appropriate Government official at least five (5) business days prior to removal. Notifications for expedited orders shall be performed IAW timeframes as listed in Section 1.2.11.

c. Mock EPA ID numbers created by DLA Disposition Services for use at non-RCRA TSDFs must be entered on all applicable shipping documentation such as non-hazardous waste manifests and bills of lading (BOL). The same mock EPA ID number must be used on DLA Disposition Services Form 2505, Manifest Tracking Log. The number format for the Bill of Lading shall be as follows: Site ID (RCWL) + BOL# + zeros filling the 12-character requirement. Example:

RCWL88888000. The EPA ID format for Conditionally Exempt Small Quantity Generators (CESQG) shall be as follows: State Abbreviation + Site DODAAC + “SMAL”. Example:

WAW68MD9SMAL.

d. For Naval Submarine Base, Bangor, Camp Wesley Harris, and Jackson Park, the following apply:

1. The Generator may mark and label all shipping containers.

2. The Generator requires the manifest number three (3) business days prior to pick-up.

1.1.3 NOTIFICATIONS

Except as may otherwise be specified herein, the Contractor shall notify the COR for each location, at least five (5) business days BEFORE attempting site visits, analyses, or pickups.

(1) In addition to the notification above for pickups, the Contractor shall provide the name of the driver, the driver’s Commercial Driver License (CDL) number and its expiration date, to the COR or other Government representative at least 24 hours prior to removal. The Contractor may also opt to provide a list of approved, multiple drivers designated for pickups under this specific contract to the COR or other Government representative prior to any attempted removals. If this option is elected and the list is approved by the Government and maintained by the Contractor, the 24-hour notification requirement is mute for the remainder of the contract unless otherwise modified except for Portland Air National Guard and Naval Magazine Indian Island.

(2) If a driver, other than the one specified 24 hours in advance for the specific TO; or, one whose name does not appear on the optional list of approved, multiple drivers arrive for pickup, the COR or other designated Government representative will verify the personnel switch with the Contractor before the pickup commences. This may require a written notice or fax from the Contractor. 24-hour advance notification in Paragraph

1.1.3 is required for Naval Magazine Indian Island and Portland Air National Guard.

NOTE: Rapid Gate may be mandatory for access to some DOD…