Richmond_Renewal_Bid_Schedule_12JUN13.xlsx

XLSX spreadsheet 178 KB Posted

Attached to
hazardous waste disposal at Richmond and Ft. Belvoir
Solicitation number
SP4500-13-R-0012
Issued by

About this file

Richmond and Ft. Belvoir Bid Schedule

View the file

Other files

File Type Posted
PL_DETAIL_-_HLIS_WITH_OR_WITHOUT_MLIS.xls XLS spreadsheet
09D07_BA_SUMMARY.xls XLS spreadsheet
SP4500-13-R-0012.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Base Period

Richmond Bid Schedule
18 Month Base Period
6300-6599 SPECIAL SERVICES
CLINDescriptionEst. QTYU/MUnit CostTotal
6311AAProvide service to place waste in containers - up to one 5 gal container200ea
6311BBProvide service to place waste in containers - one non-bulk container greater than 5 gal200ea
6312A1Provide container, 1 gal, UN 1H2/Y6/S open screw-top plastic pail with locking lid, new100ea
6312B1Provide container, 2 gal, UN 1H2/Y open screw-top plastic pail with locking lid, new25
6312C1Provide container, 5 gal, UN 1H1/Y1.8/100 closed top, plastic, new10ea
6312C2Provide container, 5 gal, UN 1H2/Y30/S open screw-top plastic pail with locking lid, new50ea
6312D1Provide container, 15 gal, UN 1H2/Y100/S open head, plastic, new25ea
6312D2Provide container, 15 gal, UN 1H1/Y closed head, plastic, new1ea
6312E1Provide container, 20 gal, UN 1A2/Y, open top steel with epoxy phenolic lining, new5ea
6312E2Provide container, 20 gal, UN 1H2/Y, open top, plastic, new5ae
6312F1Provide container, 30 gal, 1H1, closed top, plastic, reconditioned1ea
6312F2Provide container, 30 gal. UN 1H2/Y open top, plastic, new5ea
6312F3Provide container, 30 gal, UN 1H1/Y closed top, plastic, new5ea
6312F4Provide container, 30 gal, UN 1A1/Y open top, steel with epoxy phenolic lining, new1ea
6312F5Provide container, 30 gal, UN 1A2/Y closed top, steel with epoxy phenolic lining, new1ea
6312G1Provide container, 55 gal, open top, plastic, reconditioned1ea
6312G2Provide container, 55 gal, 1A1, closed top, steel, reconditioned25ea
6312G3Provide container, 55 gal, 1A2, open top, steel, reconditioned100ea
6312G4Provide container, 55 gal, 1H1, closed top, plastic, reconditioned1ea
6312G5Provide container, 55 gal, UN 1H2/Y open top, plastic, new50ea
6312G6Provide container, 55 gal, UN 1H1/Y closed top, plastic, new50ea
6312G7Provide container, 55 gal, UN 1A2/Y open top steel with epoxy phenolic lining, new50ea
6312G8Provide container, 55 gal, UN 1A1/Y closed top steel with epoxy phenolic lining, new50ea
6312H1Provide container, 85 gal UN1A2/X435/S or UN1A2T/Y320/S removable head (dual rated liquid/solid) steel with epoxy phenolic lining, new1ea
6312H2Provide container, 85 gal UN1H2/X435/S or UN1H2T/Y320/S removable head (dual rated liquid/solid) plastic, new1ea
6312H3Provide container, 95 gal UN1A2/X340/S removable head, steel with epoxy phenolic lining, new1ea
6312H4Provide container, 95 gal UN1H2/X340/S removable head, plastic, new1ea
6312J1Provide pallet, 48”x 48” 2-way entry25ea
6312J2Provide pallet, 38”x38” 2-way entry25
6312K1Provide Lamp Recycling Box, 48" x 40" x 36" triple wall gaylord box with top and bottom, capacity 50010ea
6312K2Provide UN/DOT approve X-rated cardboard cubic yard box 36”x36”x36” with minimum 3 walls of corrugation, 6 mil LDPE liner, 38”x38” pallet 2-way entry and , assembly kit (6 flat head nails with caps)20ea
631L1Provide oil dri premium absorbent 40 lb bag20ea
6312L2Provide vermiculite, non-dusty grade 4A extra-coarse, in 4 cu ft bag10ea
6312L3Provide oil only sorbent 15x19”, absorption capacity 35 gal, qty 1005ea
6312L4Provide universal sorbents 15x19”, absorption capacity 26 gal, qty 1005ea
6312L5Provide hazmat sorbent for corrosive liquids, acids/bases, 15x19”, absorption capacity 30 gal, qty 1005ea
6312L6Provide extra large disposable nitrile gloves, powder free, 6 mil, Length 11.5-10.5", unlined, rolled cuff, special features ambidextrous, qty 1005ea
6312L7Provide large disposable nitrile gloves, powder free, 6 mil, length 11.5-10.5", unlined, rolled cuff, special features ambidextrous, qty 1005ea
6312L8Provide medium disposable nitrile gloves, powder free, 6 mil, length 10-10.5", unlined, rolled cuff, special features ambidextrous, qty 1005ea
6312M1Provide container, 8ft fiber fluorescent light tube (capacity 70) UN 1G/Y50/S1ea
6312M2Provide container, 4ft fiber fluorescent light tube (capacity 85) UN 1G/Y50/S1ea
6321Provide and prepare lab packs, consisting of small quantity chemicals (55 gal) (See 3.7)50ea
6322Provide and prepare lab packs, consisting of small quantity chemicals (20-30 gal) (See 3.7)25ea
6323Provide and prepare lab packs, consisting of small quantity chemicals (5-15 gal) (See 3.7)30ea
6330Expedited removal - 15 days (See 1.2.11)10ea
6331Expedited removal - 10 days (See 1.2.11)2ea
6332Expedited removal - 7 days (See 1.2.11)2ea
6333Expedited removal - 5 days (See 1.2.11)2ea
6334Expedited removal - 3 days (See 1.2.11)5ea
6335Expedited removal - 1 day (See 1.2.11)1ea
6340Expedited performance - 15 days (See 1.2.11)10ea
6341Expedited performance - 10 days (See 1.2.11)2ea
6342Expedited performance - 7 days (See 1.2.11)2ea
6343Expedited performance - 5 days (See 1.2.11)2ea
6344Expedited performance - 3 days (See 1.2.11)5ea
6345Expedited performance - 1 day (See 1.2.11)1ea
6350AATank cleaning/services – above ground, 1 to 999 gallon capacity (See 3.2)3ea
6350BBTank cleaning/cervices – above ground, 1,000 to 3,000 gal capacity (See 3.2)3ea
6350CCTank cleaning/services – above ground, 3,001 to 6,000 gal capacity (See 3.2)3ea
6350DDTank cleaning/services – above ground, 6,001 to 12,000 gal capacity (See 3.2)1ea
6351AATank cleaning/services – below ground, 1 to 999 gal capacity (See 3.2)3ea
5351BBTank cleaning/services – below ground, 1,000 to 3,000 gal capacity (See 3.2)3ea
6351CCTank cleaning/services – below ground, 3,001 to 6,000 gal capacity (See 3.2)3ea
6351DDTank cleaning/services – below ground, 6,001 to 12,000 gal capacity (See 3.2)1ea
6352AATank cleaning/services – oil/water separator, 1 to 999 gal capacity (See 3.2)3ea
6352BBTank cleaning/services – oil/water separator, 1,000 to 3,000 gal capacity (See 3.2)3ea
6352CCTank cleaning/services – oil/water separator, 3,001 to 6,000 gal capacity (See 3.2)3ea
6352DDTank cleaning/services – oil/water separator, 6,001 to 12,000 gal capacity (See 3.2)1ea
6355FBProvide service to inflate fuel bag (See 3.15)6ea
6371Provide rolloff (15 CD) (See 3.6)1ea
6372Provide rolloff (20 CD) (See 3.6)1ea
6373Provide rolloff (25 CD) (See 3.6)3ea
6374Provide rolloff (30 CD) (See 3.6)2ea
6375Provide rolloff (40 CD) (See 3.6)1ea
6400TSPerform appropriate analysis to properly identify unknown hazardous property and complete waste profile form (See 3.5)12ea
6400AAPrepare waste profile form (See 3.4)12ea
6401Perform hazardous waste characteristics analysis to determine ignitability (D001), corrosivity (D002), & reactivity (D003) (See 3.3)25ea
6402Perform total TCLP analysis (D0004-D043) (See 3.3)25ea
6403Perform TCLP metals analysis to determine 8 TCLP metals (D004-D011) (See 3.3)3ea
6404Perform TCLP analysis to determine D012-D017 (See 3.3)1ea
6405Perform TCLP analysis to determine volatile and semivolatile organics (D018-D043) (See 3.3)1ea
6406Perform F-series solvent analysis to determine EPA waste codes F001-F005 (See 3.3)1ea
6407Perform halogenated organic compound analysis to determine 106 HOCs listed in 22 CCR 66268, Appendix III (See 3.3)5ea
6408Perform total organic halogens analysis (See 3.3)1ea
6409Perform total petroleum hydrocarbons analysis (See 3.3)12ea
6411Perform volatile organics analysis (EPA Method 8240) (See 3.3)1ea
6412Perform analysis to determine physical characteristics (physical state, color, and density) (See 3.3)1ea
6413Perform analysis to determine halogenated volatile organics (EPA Method 8101) (See 3.3)1ea
6414Perform wastewater/nonwastewater determination in accordance with 40 CFR Part 268.2 (See 3.3)1ea
6415Perform BTU and % chlorine analysis (See 3.3)1ea
6416Perform test for the percentage of total chlorine (See 3.3)1ea
6417Perform test for semi-volatile organics as listed in 22 CCR 66268, Appendix III (See 3.3)1ea
6418Provide incineration and stabilization of lab packs, non-lab packed wastes, non-regulated wastes, and soil samples (in accordance with 40 CFR 268 Appendix IV and for solid wastes not subject to regulations under 40 CFR 261) (See 3.3)1ea
6419Perform paint filter test (EPA Method 9095) (See 3.3)1ea
6420Perform the following tests: EPA 8080 PCBs and organochlorine pesticides, EPA 8140 organophosphorous pesticides, EPA 8240 volatile organics, EPA 8270 semi-volatile organics, EPA 9010 cyanides, TCLP metals (8), & CCR TTLC (17) metals. If results of TTLC are 10 times greater than STLC, then run STLC (See 3.3)1ea
6421Perform test for asbestos (See 3.3)1ea
6422Perform analysis to determine benzene, toluene, ethylbenzene, and xylene (See 3.3)1ea
6423Perform analysis to determine cresol (D026) (See 3.3)2ea
6424Perform polychlorinated biphenyl analysis (See 3.3)6ea
6450Provide liquid sample kit for analysis to determine ignitability (D001), corrosivity (D002), reactivity (D003), total TCLP analysis (D004-D043), and complete waste profile form. Analysis results and copy of completed chain of custody shall be returned within 21 days from receipt. Kit includes: sampling bottles/containers, preservatives, temperature blank, shipping cooler/ice chest, sample bags, chain of custody, & overnight prepaid shipping return label.5ea
6451Provide oil/solvent sample sample kit for analysis to determine ignitability (D001), corrosivity (D002), reactivity (D003), F-series solvent to determine EPA waste codes F001-F005, PCB analysis, and complete waste profile form. Analysis results and copy of completed chain of custody shall be returned within 21 days from receipt. Kit includes: sampling bottles/containers, preservatives, temperature blank, shipping cooler/ice chest, sample bags, chain of custody, & overnight prepaid shipping return label.5ea
6452Provide solids sample kit for analysis to determine ignitability (D001), corrosivity (D002), reactivity (D003), and total TCLP analysis (D004-D043). Analysis results and copy of completed chain of custody shall be returned within 21 days from receipt. Kit includes: sampling bottles/containers, preservatives, temperature blank, shipping cooler/ice chest, sample bags, chain of custody, & overnight prepaid shipping return label.5ea
6453Provide sample kit for PCB analysis and hazardous waste characteristics analysis to determine ignitability (D001), corrosivity (D002), reactivity (D003), and total TCLP (D004-D043). Analysis results and copy of completed chain of custody shall be returned within 21 days from receipt. Kit includes: sampling bottles/containers, preservatives, temperature blank, shipping cooler/ice chest, sample bags, chain of custody, & overnight prepaid shipping return label.5ea
6454Provide solids sample kit for analysis to determine ignitability (D001), corrosivity (D002), and reactivity (D003). Analysis results and copy of completed chain of custody shall be returned within 21 days from receipt. Kit includes: sampling bottles/containers, preservatives, temperature blank, shipping cooler/ice chest, sample bags, chain of custody, & overnight prepaid shipping return label.1ea
6455Provide solids sample kit for TCLP metals analysis to determine 8 TCLP metals (D004-D011). Analysis results and copy of completed chain of custody shall be returned within 21 days from receipt. Kit includes: sampling bottles/containers, preservatives, temperature blank, shipping cooler/ice chest, sample bags, chain of custody, & overnight prepaid shipping return label.1ea
6456Provide solids sample kit for total TCLP analysis (D004-D043). Analysis results and copy of completed chain of custody shall be returned within 21 days from receipt. Kit includes: sampling bottles/containers, preservatives, temperature blank, shipping cooler/ice chest, sample bags, chain of custody, & overnight prepaid shipping return label.1ea
6457Provide solids sample kit for TCLP analysis to determine D012-D017. Analysis results and copy of completed chain of custody shall be returned within 21 days from receipt. Kit includes: sampling bottles/containers, preservatives, temperature blank, shipping cooler/ice chest, sample bags, chain of custody, & overnight prepaid shipping return label.1ea
6458Provide solids sample kit for TCLP analysis to determine volatile and semi-Volatile organics (D018 - D043). Analysis results and copy of completed chain of custody shall be returned within 21 days from receipt. Kit includes: sampling bottles/containers, preservatives, temperature blank, shipping cooler/ice chest, sample bags, chain of custody, & overnight prepaid shipping return label.1ea
6459Provide sample kit for PCB analysis. Analysis results and copy of completed chain of custody shall be returned within 21 days from receipt. Kit includes: sampling bottles/containers, preservatives, temperature blank, shipping cooler/ice chest, sample bags, chain of custody, & overnight prepaid shipping return label.5ea
6460Provide sample kit for atomic absorption analysis for Lead, analysis method for flame, air, wipes, paints, and soils/solids. EPA 600/R-93/200 (M)-7000B. Analysis results and copy of completed chain of custody shall be returned within 21 days from receipt. Kit includes: sampling bottles/containers, preservatives, temperature blank, shipping cooler/ice chest, sample bags, chain of custody, & overnight prepaid shipping return label.5ea
6461Provide sampling kit for analysis to perform TPH DRO (8015M) in soil. Analysis results and copy of completed chain of custody shall be returned within 21 days from receipt. Kit includes: sampling bottles/containers, preservatives, temperature blank, shipping cooler/ice chest, sample bags, chain of custody, & overnight prepaid shipping return label.10ea
6462Provide sampling kit for analysis to perform TPH GRO (8015M) in soil. Analysis results and copy of completed chain of custody shall be returned within 21 days from receipt. Kit includes: sampling bottles/containers, preservatives, temperature blank, shipping cooler/ice chest, sample bags, chain of custody, & overnight prepaid shipping return label.
10ea
6463Provide sampling kit to perform % Water by Karl Fischer.

Analysis results and copy of completed chain of custody shall be returned within 21 days from receipt. Kit includes: sampling bottles/containers, preservatives, temperature blank, shipping cooler/ice chest, sample bags, chain of custody, & overnight prepaid shipping return label.

5ea
6502MVManagement services (See 3.10)75ea
6502ACManagement services (See 3.11)75ea
6502ADManagement services (See 3.12)75ea
6502AEManagement services (See 3.13)5ea
6502AFManagement services (See 3.14)5ea
6503Provide certificate of disposal (See 2.1.2)2ea
6601Evaluate unknown compressed gas cylinder (See 2.3.1)4ea
6608Perform appropriate sampling and analysis to properly identify the gas and complete the waste profile form (See 2.3.2)4ea
6609AAPerform management services, may include repackaging the contents of one compressed gas cylinder that is not DoT transportable (non-inert gas) (See 2.3.3)4ea
6609BBPeform management services, may include replacing a valve that is not operable (See 2.3.3)4ea
6609BTTransportation surcharge (See 3.9)2ea
6609LSLabor charges for project management/supervision for emergency response (See 3.8)1hr
6609LPLabor charges for professional services emergency response (See 3.8)1hr
6609LQLabor charges for equipment operator for emergency response (See 3.8)1hr
6609LGLabor charges, general, for emergency response (See 3.8)1hr
6609MEEquipment and supplies reimbursment for emergency response (See 3.8)1ea/NTE$ 10,000.00
6610PAPoison, hazard zone "A" surcharge (See 2.3.4)1ea
Profile Based CLINs
Base CLINDescriptionSuffixEst. Qty.U/MUnit CostTotal
Batteries for Recycle/Disposal

BA01 Alkaline Batteries, Managed as Universal Waste for Recycling or Direct Landfill Disposal Physical State: Solid

Permissible Waste Codes: N/AC74,850LB
BA02Calcium Chromate (CaCrO4) Thermal Batteries, Deactivated, Managed as Universal Waste for Recycling or Disposal

Physical State: Solid Permissible Waste Codes: D003, D007

C710LB
BA03Carbon-Zinc (CZn) Batteries, Managed as Universal Waste for Recycling

Physical State: Solid Permissible Waste Codes: N/A

C71,080LB
BA04Lead Acid Batteries, Managed as Universal Waste for Recycling

Physical State: Solid Permissible Waste Codes: N/A

C727,000LB
BA05Lithium Ion (Li-Ion) Batteries, Managed as Universal Waste for Recycling

Physical State: Solid Permissible Waste Codes: N/A

C78,000LB
BA06Lithium Iron Sulfide (Li2FeS2) Thermal Batteries, Deactivated, Managed as Universal Waste for Recycling or Destruction & Disposal

Physical State: Solid Permissible Waste Codes: D003

C75,000LB
BA07Lithium Manganese (LiMn) Batteries, Managed as Universal Waste for Recycling or Destruction & Disposal

Physical State: Solid Permissible Waste Codes: D003

C75,000LB
BA08Lithium Sulfur Dioxide (LiSO2) Batteries, Managed as Universal Waste for Recycling or Destruction & Disposal

Physical State: Solid Permissible Waste Codes: D003

C725,000LB
BA09Lithium Thionyl Chloride (LiSCl) Batteries, Managed as Universal Waste for Recycling or Destruction & Disposal

Physical State: Solid Permissible Waste Codes: D003

C72,000LB
BA10Lithium Batteries, Mixed Types, Deactivated if Applicable, Managed as Universal Waste for Recycling or Destruction & Disposal

Physical State: Solid Permissible Waste Codes: D003

C726,000LB
BA11Magnesium (Mg) Batteries, Managed as Universal Waste for Recycling

Physical State: Solid Permissible Waste Codes: N/A

C7500LB
BA12Mercury (Hg) Batteries, Managed as Universal Waste for Recycling

Physical State: Solid Permissible Waste Codes: N/A

C71,000LB
BA13Nickel Metal Hydride (NiMh) Batteries, Managed as Universal Waste for Recycling

Physical State: Solid Permissible Waste Codes: N/A

C7500LB
BA14Nickel-Cadmium (NiCd) Batteries, Managed as Universal Waste for Recycling

Physical State: Solid Permissible Waste Codes: N/A

C72,500LB
BA15Silver-Zinc (AgZn) and Zinc Silver Oxide (ZnAgO) Batteries, Managed as Universal Waste for Recycling

Physical State: Solid Permissible Waste Codes: N/A

C7750LB
CORROSIVES

CS01 Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, <1% Total Metals, Cr+6 <100 ppm Physical State: Liquid

Permissible Waste Codes: D002, D004-11, Listed InorganicsC150EA
C250EA
C350EA
C425EA
C510EA

CS02 Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, >1% Total Metals, Cr+6 <100 ppm Physical State: Liquid

Permissible Waste Codes: D002, D004-11, Listed InorganicsC110EA
C25EA
C35EA
C45EA
C51EA

CS03 Corrosive Acids, Inorganic other than HF and HNO3, Concentrated, <1% Total Metals, Cr+6 <100 ppm Physical State: Liquid

Permissible Waste Codes: D002, D004-11, Listed InorganicsC110EA
C215EA
C315EA
C410EA
C510EA

CS04 Corrosive Acids, Chromic (H2Cr04 ), <1% Cr+6, Characteristic Liquids, Solids, Sludges, Debris Physical State: Mixed

Permissible Waste Codes: D001 (Oxidizer) D002, D004-11C13EA
C23EA
C33EA
C43EA
C53EA

CS05 Corrosive Acids, Chromic (H2Cr04 ), 1-10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris Physical State: Mixed

Permissible Waste Codes: D001 (Oxidizer) D002, D004-11C13EA
C23EA
C33EA
C43EA
C53EA

CS06 Corrosive Acids, Chromic (H2Cr04), >10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris

Permissible Waste Codes: D001 (Oxidizer) D002, D004-11C13EA
C23EA
C33EA
C43EA
C53EA

CS07 Corrosive Acids, Chromic (H2Cr04 ), >100 ppm Cr+6, F-Listed Liquids, Solids, Sludges, Debris

Permissible Waste Codes: D001 (Oxidizer), D002, D004-11, F-ListedC13EA
C23EA
C33EA
C43EA
C53EA

CS08 Corrosive Acids, Hydrofluoric (HF) and Nitric (HNO3), <50% in Water, <1% Total Metals, Cr+6 <100 ppm

Permissible Waste Codes: D002, D004-11, Listed InorganicsC110EA
C210EA
C310EA
C410EA
C510EA

CS09 Corrosive Acids, Hydrofluoric (HF) and Nitric (HNO3), >50% in Water, <1% Total Metals, Cr+6 <100 ppm Physical State: Liquid

Permissible Waste Codes: D002, D004-11, Listed InorganicsC110EA
C210EA
C310EA
C410EA

CS10 Corrosive Alkalines, Inorganic, <50% in Water, <1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines

Permissible Waste Codes: D002, D004-11, Listed InorganicsC110EA
C220EA
C325EA
C420EA
C510EA

CS11 Corrosive Alkalines, Inorganic, <50% in Water, >1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines Physical State: Liquid

Permissible Waste Codes: D002, D004-11, Listed InorganicsC115EA
C220EA
C315EA
C410EA

CS12 Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/Sludges/Solids/Debris, Non-Flammable

Permissible Waste Codes: D002, D004-11, ListedC1125EA
C250EA
C325EA
C450EA

CS13 Corrosive Organic Acids or Bases, Liquids/Sludges/Solids/Debris, No Ammonia/Amines, Non-Flammable

Permissible Waste Codes: D002, D004-11, ListedC134EA
C250EA
C325EA
C450EA

CS14 Corrosive Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries

Permissible Waste Codes: D002, D004-11, ListedC126EA
C225EA
C320EA
C410EA
C510EA
CS15Corrosive Aerosols, Non-Flammable

Physical State: Mixed

Permissible Waste Codes: D002, D004-11, ListedC15EA
C25EA
C35EA
C41EA

COMPRESSED GAS CYLINDERS

CY01 Cylinders, Category 1, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12", Small (M1) = 4"x 24", Medium (M2) = 12"x 36", Large (M3) = 16"x 56"

Permissible Waste Codes: See Cylinder CLIN Reference List

ME500EA
M1200EA
M2250EA
M320EA
M3EA
CY02Cylinders, Category 2, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12", Small (M1) = 4"x 24", Medium (M2) = 12"x 36", Large (M3) = 16"x 56"

Physical State: Solid Permissible Waste Codes: See Cylinder CLIN Reference List

ME400EA
M1300EA
M2150EA
M31EA
CY03Cylinders, Category 3, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12", Small (M1) = 4"x 24", Medium (M2) = 12"x 36", Large (M3) = 16"x 56"

Physical State: Solid Permissible Waste Codes: See Cylinder CLIN Reference List

ME5EA
M15EA
M25EA

CY04 Cylinders, Category 4, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12", Small (M1) = 4"x 24", Medium (M2) = 12"x 36", Large (M3) = 16"x 56" Physical State: Solid Permissible Waste Codes: See Cylinder CLIN Reference List

ME5EA
M15EA
M25EA

CY05 Cylinders, Category 5, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12", Small (M1) = 4"x 24", Medium (M2) = 12"x 36", Large (M3) = 16"x 56" Physical State: Solid Permissible Waste Codes: See Cylinder CLIN Reference List

ME5EA
M15EA
M25EA

CY06 Cylinders, Category 3, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12", Small (M1) = 4"x 24", Medium (M2) = 12"x 36", Large (M3) = 16"x 56" Physical State: Solid Permissible Waste Codes: See Cylinder CLIN Reference List

ME5EA
M15EA
M25EA

CY07 Cylinders, Category 7, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12", Small (M1) = 4"x 24", Medium (M2) = 12"x 36", Large (M3) = 16"x 56" Physical State: Solid Permissible Waste Codes: See Cylinder CLIN Reference List

ME1EA
M11EA
M21EA

CY08 Cylinders, Category 8, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12", Small (M1) = 4"x 24", Medium (M2) = 12"x 36", Large (M3) = 16"x 56" Physical State: Solid Permissible Waste Codes: See Cylinder CLIN Reference List

ME1EA
M11EA
M21EA

CY09 Cylinders, Acetylene, for Purge and Landfill. Lecture (ME) = 3"x 12", Small (M1) = 4"x 24", Medium (M2) = 12"x 36", Large (M3) = 16"x 56" Physical State: Solid Permissible Waste Codes: D001

ME20EA
M17EA
M25EA
M36EA
CY10Cylinders, Acetylene, for Recycle/Reuse. Lecture (ME) = 3"x 12", Small (M1) = 4"x 24", Medium (M2) = 12"x 36", Large (M3) = 16"x 56"

Physical State: Solid Permissible Waste Codes: D001

ME20EA
M15EA
M25EA

CY11 Cylinders, Propane, 20-Lb "Grill Size", for Disposal/Recycle/Reuse. Typically 13" x 17" Physical State: Solid Permissible Waste Codes: D001

ME20EA
CY12Cartridges, Flammable Gas, AVGAS, Gas/Diesel Starting, for Disposal/Recycle. Diameter up to 3", Length up to 10"

Physical State: Solid Permissible Waste Codes: D001

ME20EA
CY13Cartridges, Inert Gas, for Disposal/Recycle/Reuse. Diameter up to 1", Length up to 6"

Physical State: Solid Permissible Waste Codes: N/A

ME100EA
FLAMMABLE/COMBUSTIBLE/IGNITABLE

FL01 Flammable Aerosols, Non-Foaming, No Isocyanates

Permissible Waste Codes: D001 (IGN), D004-43, ListedC1100EA
C220EA
C310EA
C429EA
C52EA
C65EA
FL02Flammable Debris, Contaminated with Common Solvents, Shreddable, No Free Liquids, No large metal, rock, or masonry components

Physical State: Solid

Permissible Waste Codes: D001, D004-43, ListedC115EA
C25EA
C317EA
C451EA
C51EA
C61EA

FL03 Flammable Liquids/Solids/Sludges/Debris, i.e. tank sludge, lubricants, paint-related waste, adhesives, rags, filters, PPE

Permissible Waste Codes: D001-2, D004-43, ListedC110EA
C220EA
C330EA
C4100EA
C51EA

FL04 Flammable Corrosive Liquids/Solids/Sludges/Debris

Permissible Waste Codes: D001 (IGN), D002, D004-43, ListedC11EA
C21EA
C31EA
C45EA

FL05 Flammable Liquids, Pumpable, Rich, >7,000 BTU/Lb, <5% Total Chlorine Physical State: Liquid

Permissible Waste Codes: D001 (IGN), D004-43, ListedC16EA
C25EA
C38EA
C487EA
C517EA
B55,000GL
FL06Flammable Liquids, Pumpable, Lean, 2,500-7,000 BTU/Lb, <5% Total Chlorine

Permissible Waste Codes: D001 (IGN), D004-43, Listed C4 20 EA

B5 5,000 GL

FL07 Flammable Liquids, Pumpable, Lean to Rich, >2,500 BTU/Lb, 5-10% Total Chlorine

Permissible Waste Codes: D001 (IGN), D004-43, ListedC45EA
B52,000GL

FL08 Flammable Resuspendable Solids/Sludges, Rich, >7,000 BTU/Lb, <5% Total Chlorine

Permissible Waste Codes: D001 (IGN), D004-43, ListedC11EA
C21EA
C31EA
C410EA

FL09 Flammable Resuspendable Solids/Sludges, Lean, 2,500-7,000 BTU/Lb, <5% Total Chlorine Physical State: Mixed

Permissible Waste Codes: D001 (IGN), D004-43, ListedC11EA
C21EA
C31EA
C410EA

FL10 Flammable Resuspendable Solids/Sludges, Lean to Rich, >2,500 BTU/Lb, 5-10% Total Chlorine Physical State: Mixed

Permissible Waste Codes: D001 (IGN), D004-43, ListedC11EA
C21EA
C31EA
C45EA

FL13 Oxidizers, Non-Reactive, other than chromic acid (see Corrosives), Liquids/Sludges/Solids/Debris Physical State: Mixed

Permissible Waste Codes: D001-2, D004-43, ListedC11EA
C21EA
C31EA
C415EA
C51EA

FL14 Paints, Loose-Packed, Latex and/or Oil-Based, >2,500 BTU/Lb (See Non-Reg CLIN for 100% Latex)

Permissible Waste Codes: D001 (IGN), D004-43, ListedC15EA
C22EA
C32EA
C4100EA
C51EA
C630EA
LAB PACKS/LOOSE PACKS

LP01 Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable

Permissible Waste Codes: D002, D004-11, Listed CorrosivesC121EA
C220EA
C320EA
C415EA
C52EA
C610EA
LP02Mercury, Elemental Liquid

Physical State: Mixed

Permissible Waste Codes: D004-11, Listed InorganicsC110EA
LP03Flammables other than Paints

Physical State: Mixed

Permissible Waste Codes: D001-2, D004-43, Listed FlammablesC120EA
C25EA
C35EA
C420EA
C53EA
C610EA
LP04Non-RCRA, State-Regulate/Non-State Regulated, other than paints, including pharmaceuticals

Physical State: Mixed

Permissible Waste Codes: N/AC125EA
C230EA
C330EA
C430EA
C55EA
C625EA
LP05Non-Reactive Oxidizers

Permissible Waste Codes: D001 (Oxidizer), D004-11, Listed C1 5 EA

C41EA
C51EA
C61EA
LP06Reactive Oxidizers, Includes Organic Peroxides, Special Packaging Required

Permissible Waste Codes: D001 (Oxidizer), D003-11, Listed C1 6 EA

C41EA
C51EA
C61EA
LP07Reactive Metals, Wet/Dry, Includes Broken Sodium Lamps, Special Packaging Required

Permissible Waste Codes: D001, D003-11, Listed C1 4 EA

C41EA
C51EA
C61EA
LP08Reactives, Non-Metals, Non-Oxidizing, Special Packaging Required

Physical State: Mixed

Permissible Waste Codes: D001-43, ListedC11EA
C21EA
C31EA
C41EA
C51EA
C61EA
LP09Toxic Metals

Permissible Waste Codes: D004-11, Listed Inorganics C1 8 EA

C41EA
C51EA
C61EA
LP10Toxic Organics

Permissible Waste Codes: D004-43, Listed C1 2 EA

C41EA
C51EA
C61EA
LP11Toxic, Acutely Hazardous, P-Listed, including pharmaceuticals

Permissible Waste Codes: D004-43, P-Listed Codes C1 4 EA

C41EA
C51EA
C61EA
LP12Toxic, U-Listed, including pharmaceuticals

Permissible Waste Codes: D004-43, U-Listed Codes C1 10 EA

C410EA
C51EA
C61EA
NON-RCRA, STATE AND NON-STATE REGULATED

NR01 Solids, Direct Landfill Ready (Subtitle D or Equivalent). No Free Liquids.

Permissible Waste Codes: N/AC116EA
C210EA
C315EA
C487EA
C51EA
C61EA
B12,000LB

NR02 Solids with Asbestos, Direct Landfill Ready (Subtitle D or Equivalent). Special Packaging Required. No Free Liquids.

Permissible Waste Codes: N/AC125EA
C220EA
C310EA
C410EA
C51EA
B11,200LB
B220,000LB

NR03 Liquids, Pumpable, Aqueous (Water-Based)

Permissible Waste Codes: N/AC1100EA
C225EA
C310EA
C4100EA
C57EA
B52,000GL
NR04Liquids, Pumpable, Organic-Based

Physical State: Liquid

Permissible Waste Codes: N/AC120EA
C25EA
C310EA
C420EA
C51EA
B51,000GL
NR05Sludges/Solids/Debris with Free Liquids

Physical State: Mixed

Permissible Waste Codes: N/AC115EA
C210EA
C311EA
C465EA
C53EA
B12,000LB

NR06 Loose-Packed Paints, 100% Water-Based (Latex)

Permissible Waste Codes: N/AC181EA
C230EA
C320EA
C430EA
C55EA
C620EA
NR07Pharmaceuticals for Thermal Destruction, Prescription and Non-Prescription. No DEA Restricted Meds. Certificate of Destruction Required.

Permissible Waste Codes: N/A C1 1 EA

C41EA
C51EA
C61EA
NR08RCRA-Empty Containers, Metal & Plastic/Poly, Crushed, Recycle or Disposal

Physical State: Solid

Permissible Waste Codes: N/AB15,000LB
NR09RCRA-Empty Containers, Metal, Intact, Recycle or Disposal

Physical State: Solid

Permissible Waste Codes: N/AC15EA
C25EA
C35EA
C45EA
C55EA
NR10RCRA-Empty Containers, Plastic/Poly, Intact, Recycle or Disposal

Physical State: Solid

Permissible Waste Codes: N/AC15EA
C25EA
C35EA
C45EA
C55EA
NR96Liquids, Pumpable, Non-Regulated, for RCRA Incineration. Certificate of Disposal Required.

Permissible Waste Codes: N/A

C4 15 EA

NR98 Military Articles, Non-RCRA, i.e. Boots, Gloves, CDE Kits, Filters, Masks, MOPP Suits, etc. for Demil via Thermal Destruction. Certificate of Disposal/Destruction Required.

Permissible Waste Codes: N/A B1 2,000 LB

PCBs

PC03 PCB Mineral Oil from Transformers, 50-4,000 ppm PCBs. Non-RCRA, Certificate of Recycling or Destruction Required.

Permissible Waste Codes: N/AC73,115LB
PC05PCB Oil-Filled Capacitors/Equipment other than Transformers, 0-49 ppm PCBs, Non-RCRA, Certificate of Recycling or Destruction Required

Physical State: Mixed

Permissible Waste Codes: N/AC71,000LB
PC06PCB Oil-Filled Capacitors/Equipment other than Transformers, >50 ppm PCBs, Non-RCRA, Certificate of Recycling or Destruction Required.

Physical State: Mixed

Permissible Waste Codes: N/AC71,000LB
PC07PCB Oil-Filled Transformers, 0-49 ppm PCBs. Certificate of Recycling or Destruction Required.

Physical State: Mixed

Permissible Waste Codes: N/AC78,700LB
PC08PCB Oil-Filled Transformers, >50 ppm PCBs. Certificate of Recycling or Destruction Required.

Physical State: Mixed

Permissible Waste Codes: N/AC74,000LB
PC09PCB Solids/Debris Contaminated with 1-50 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Certificate of Disposal Required.

Physical State: Solid

Permissible Waste Codes: N/AC7200LB
PC10PCB Solids/Debris Contaminated with >50 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Certificate of Disposal Required.

Physical State: Solid

Permissible Waste Codes: N/AC72,000LB
RECYCLE/RECOVER

RE01 Lamps, Fluorescent, Intact, CFLs and <4 ft = Each (ME), U-Bent, Circulars and 4-6 ft Linears = Small (M1), 6-8 ft = Medium (M2), >8 ft = Large (M3)

Permissible Waste Codes: Universal WasteME2,220EA
M117,000EA
M2300EA
M3100EA
RE02Lamps, Fluorescent, Crushed/Broken, with Filters

Permissible Waste Codes: Universal Waste C1 1,000 EA

C415EA
RE03Lamps, Halogen

Physical State: Solid

Permissible Waste Codes: Universal WasteME25EA
RE04Lamps, High Intensity Discharge (HID)

Physical State: Solid

Permissible Waste Codes: Universal WasteME250EA
RE05Lamps, Mercury/Mercury Vapor

Physical State: Solid

Permissible Waste Codes: Universal WasteME300EA
RE06Lamps, Metal Halide and Metal Hydride, including Sodium

Physical State: Solid

Permissible Waste Codes: Universal WasteME425EA
RE07Mercury, High, COD Vials, Hg >260 mg/Kg

Permissible Waste Codes: Universal Waste C1 2 EA

RE08 Mercury, High, Dental Amalgams, Hg >260 mg/Kg

Permissible Waste Codes: Universal Waste C1 26 EA

RE09 Mercury, High, Liquid Mercury/Devices, Debris & Residues, Hg >260 mg/Kg

Permissible Waste Codes: Universal WasteC125EA
C220EA

RE10 Antifreeze, Used and Unused for Recycling or Fuels Blending. RE10ME refers to 55-GL drums pumped/vacuumed/stung onsite and includes recycling and service (drums not removed).

Permissible Waste Codes: Universal WasteC110EA
C225EA
C325EA
C4100EA
C51EA

RE11 Used Oil, <10% Water, <1,000 ppm Total Organic Halides. RE11ME refers to 55-GL drums pumped/vacuumed/stung onsite and includes recycling and service (drums not removed).

Permissible Waste Codes: Universal WasteC12EA
C23EA

C4 6 EA

RE12 Used Oil, >10% Water, <1,000 ppm Total Organic Halides. RE12ME refers to 55-GL drums pumped/vacuumed/stung onsite and includes recycling and service (drums not removed).

Permissible Waste Codes: Universal Waste C1 55 EA

C4 38 EA

RE13 Used Oil Filters, Drained and Undrained

Permissible Waste Codes: Universal WasteC33EA
C430EA

REACTIVES

RX01 Aerosols, Foaming, Isocyanates or other reactives

Permissible Waste Codes: D001, D003, D004-43, ListedC110EA
C210EA
C35EA
C45EA

RX06 Oxidizers, i.e. Nitrates, Nitites, Persulfates, Inorganic Peroxides, No Organic Peroxides

Permissible Waste Codes: D001, D003, D004-11, ListedC110EA
C210EA
C310EA
C41EA

RX07 Polymerizing Materials, i.e. Styrene, Isocyanates, Acrylates Physical State: Mixed

Permissible Waste Codes: D001, D003, D004-11, ListedC12EA
C25EA
C32EA
C42EA

RX08 Reactive Metals, i.e. Powders, Dusts, Fines. Air/Water Reactive. Shipped Under Oil and/or Special Packaging.

Physical State: Solid

Permissible Waste Codes: D001, D003, D004-11, ListedC15EA
C21EA
C31EA

RX09 Reactive Metals, Debris. Air/Water Reactive. Shipped Under Oil and/or Special Packaging.

Permissible Waste Codes: D001, D003, D004-11, ListedC15EA
C21EA
C31EA

RX10 Reactives, Non-Metals, i.e. P-Coded, Temperature Sensitive, PIHs, Air/Water Reactive

Permissible Waste Codes: D001, D003, D004-11, ListedC15EA
C21EA
C31EA

TOXIC

TX01 Chromium, Hexavalent, <1% Cr+6, Characteristic Liquids, Solids, Sludges

Permissible Waste Codes: D001 (Oxidizer), D004-11C13EA
C21EA
C31EA
C45EA

TX02 Chromium, Hexavalent, 1-10% Cr+6, Characteristic Liquids, Solids, Sludges

Permissible Waste Codes: D001 (Oxidizer), D004-11C21EA
C31EA
C43EA

TX03 Chromium, Hexavalent, >10% Cr+6, Characteristic Liquids, Solids, Sludges

Permissible Waste Codes: D001 (Oxidizer), D004-11C21EA
C31EA
C42EA

TX04 Chromium, Hexavalent, <1% Cr+6, Listed Liquids, Solids, Sludges

Permissible Waste Codes: D004-11, F006-12, F019C21EA
C31EA
C45EA

TX05 Chromium, Hexavalent, Wastewater, Pumpable, <1% Total Metals

Permissible Waste Codes: D004-11, Listed InorganicsC21EA
C31EA
C44EA

TX06 Debris, Inorganic Constituents Only. >50% debris by volume, >60 mm (~2.5") particle size. No free liquids unless incidental rainwater/condensation.

Physical State: Debris

Permissible Waste Codes: D004-11, Listed InorganicsC11EA
C22EA
C32EA
C411EA
C51EA

TX07 Debris, Organic and/or Inorganic Constituents. >50% Debris by volume, >60 mm (~2.5") Particle size. No free liquids unless incidental rainwater/condensation.

Permissible Waste Codes: D004-43, Listed, but no F020-32.C13EA
C21EA
C31EA
C46EA
C52EA
C62EA
B11,200LB

TX08 Dioxins, Furans, and Precursors. Liquids, Solids, Sludges, Debris.

Permissible Waste Codes: D004-43, ListedC21EA
C31EA
C41EA

TX09 High Halogen Liquids/Sludges/Solids/Debris, Non-Flammable, Includes Solvents, Herbicides and Pesticides, Characteristic/Listed

Permissible Waste Codes: D004-43, ListedC11EA
C21EA
C31EA
C41EA
C52EA

TX10 Metals in Wastewater, <5% Suspended Solids, <1% Total Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/Listed

Permissible Waste Codes: D004-11, Listed InorganicsC21EA
C31EA
C41EA

TX11 Metals in Wastewater, <5% Suspended Solids, >1% Total Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/Listed

Permissible Waste Codes: D004-11, Listed InorganicsC21EA
C31EA
C41EA

TX12 Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Characteristic

Permissible Waste Codes: D004-11C12EA
C21EA
C31EA
C45EA

TX13 Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Listed

Permissible Waste Codes: D004-11, ListedC21EA
C31EA
C45EA
C51EA

TX14 Metals-Bearing Liquids, High, >1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Characteristic

Permissible Waste Codes: D004-11C25EA
C31EA
C45EA

TX15 Metals-Bearing Liquids, High, >1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Listed

Permissible Waste Codes: D004-11, ListedC21EA
C31EA
C46EA

TX16 Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic

Permissible Waste Codes: D004-11C11EA
C21EA
C31EA
C45EA

TX17 Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Listed

Permissible Waste Codes: D004-11, ListedC21EA
C31EA
C42EA

TX18 Metals-Bearing Solids/Sludges/Some Free Liquids, High (>1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic

Permissible Waste Codes: D004-11C21EA
C31EA
C44EA

TX19 Metals-Bearing Solids/Sludges/Some Free Liquids, High (>1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Listed

Permissible Waste Codes: D004-11, ListedC21EA
C33EA
C45EA

TX20 Metals-Bearing Debris/Solids/Sludges with Free Liquids, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/Listed

Permissible Waste Codes: D004-11, ListedC21EA
C31EA
C45EA

TX21 Organics in Water, Pumpable, <10% Suspended Solids, <10% Organics, i.e. Toluene, Phenol in water. Not more toxic than common solvents.

Permissible Waste Codes: D004-43, ListedC21EA
C32EA
C44EA

TX22 Organics in Solids/Sludges/Debris, i.e. Soil, Tank & Still Bottoms, Adhesives, Filtercake. Not more toxic than common solvents.

Permissible Waste Codes: D004-43, ListedC21EA
C31EA
C42EA

TX23 Toxic/Hazardous Solids and Debris Meeting Universal Treatment Standards (UTS). Subtitle C Landfill Ready. No Free Liquids or PCBs.

Permissible Waste Codes: ListedC15EA
C21EA
C33EA
C44EA

B1 2,000 LB

TX98 Military Items, RCRA Toxic, i.e. CDE Kits, Tents, Filters, PPE, etc. for RCRA Incineration.

Permissible Waste Codes: D004-43, ListedC22EA
C32EA
C45EA
CLIN TypeUnit CLIN/Unit of Issue DesignationsSuffixU/M
Containerized0-5 Gal (DM/DF)C1EA
6-15 Gal (DM/DF)C2EA
16-30 Gal (DM/DF)C3EA
31-55 Gal (DM/DF)C4EA
56-95 Gal (DM/DF)C5EA
Cubic Yard Box, Cubic Yard Bag, Tri-Wall, or PalletC6EA
Pounds (Containerized)C7LB
BulkPounds (Bulk) For Loads <10,000 Lbs Net WeightB1LB
Pounds (Bulk) For Loads 10,000-20,000 Lbs Net WeightB2LB
Pounds (Bulk) For Loads 20,000-30,000 Lbs Net WeightB3LB
Pounds (Bulk) For Loads >30,000 Lbs Net WeightB4LB
GallonsB5GL
Cubic Yards for Lightweight Solids/Debris <600 LB/CYB6CD
Miscellaneous Lamps, CylindersEach or Lecture (≤ 3" diameter x 12" height for cylinders)MEEA
Small (≤ 4" diameter x 24" height for cylinders)M1EA
Medium (≤ 12" diameter x 36" height for cylinders)M2EA
Large (≤ 16" diameter x 56" height for cylinders)M3EA

1st Option

Richmond Bid Schedule
18 Month 1st Option Period
6300-6599 SPECIAL SERVICES
CLINDescriptionEst. QTYU/MUnit CostTotal
6311AAProvide service to place waste in containers - up to one 5 gal container200ea
6311BBProvide service to place waste in containers - one non-bulk container greater than 5 gal200ea
6312A1Provide container, 1 gal, UN 1H2/Y6/S open screw-top plastic pail with locking lid, new100ea
6312B1Provide container, 2 gal, UN 1H2/Y open screw-top plastic pail with locking lid, new25
6312C1Provide container, 5 gal, UN 1H1/Y1.8/100 closed top, plastic, new10ea
6312C2Provide container, 5 gal, UN 1H2/Y30/S open screw-top plastic pail with locking lid, new50ea
6312D1Provide container, 15 gal, UN 1H2/Y100/S open head, plastic, new25ea
6312D2Provide container, 15 gal, UN 1H1/Y closed head, plastic, new1ea
6312E1Provide container, 20 gal, UN 1A2/Y, open top steel with epoxy phenolic lining, new5ea
6312E2Provide container, 20 gal, UN 1H2/Y, open top, plastic, new5ae
6312F1Provide container, 30 gal, 1H1, closed top, plastic, reconditioned1ea
6312F2Provide container, 30 gal. UN 1H2/Y open top, plastic, new5ea
6312F3Provide container, 30 gal, UN 1H1/Y closed top, plastic, new5ea
6312F4Provide container, 30 gal, UN 1A1/Y open top, steel with epoxy phenolic lining, new1ea
6312F5Provide container, 30 gal, UN 1A2/Y closed top, steel with epoxy phenolic lining, new1ea
6312G1Provide container, 55 gal, open top, plastic, reconditioned1ea
6312G2Provide container, 55 gal, 1A1, closed top, steel, reconditioned25ea
6312G3Provide container, 55 gal, 1A2, open top, steel, reconditioned100ea
6312G4Provide container, 55 gal, 1H1, closed top, plastic, reconditioned1ea
6312G5Provide container, 55 gal, UN 1H2/Y open top, plastic, new50ea
6312G6Provide container, 55 gal, UN 1H1/Y closed top, plastic, new50ea
6312G7Provide container, 55 gal, UN 1A2/Y open top steel with epoxy phenolic lining, new50ea
6312G8Provide container, 55 gal, UN 1A1/Y closed top steel with epoxy phenolic lining, new50ea
6312H1Provide container, 85 gal UN1A2/X435/S or UN1A2T/Y320/S removable head (dual rated liquid/solid) steel with epoxy phenolic lining, new1ea
6312H2Provide container, 85 gal UN1H2/X435/S or UN1H2T/Y320/S removable head (dual rated liquid/solid) plastic, new1ea
6312H3Provide container, 95 gal UN1A2/X340/S removable head, steel with epoxy phenolic lining, new1ea
6312H4Provide container, 95 gal UN1H2/X340/S removable head, plastic, new1ea
6312J1Provide pallet, 48”x 48” 2-way entry25ea
6312J2Provide pallet, 38”x38” 2-way entry25
6312K1Provide Lamp Recycling Box, 48" x 40" x 36" triple wall gaylord box with top and bottom, capacity 50010ea
6312K2Provide UN/DOT approve X-rated cardboard cubic yard box 36”x36”x36” with minimum 3 walls of corrugation, 6 mil LDPE liner, 38”x38” pallet 2-way entry and , assembly kit (6 flat head nails with caps)20ea
631L1Provide oil dri premium absorbent 40 lb bag20ea
6312L2Provide vermiculite, non-dusty grade 4A extra-coarse, in 4 cu ft bag10ea
6312L3Provide oil only sorbent 15x19”, absorption capacity 35 gal, qty 1005ea
6312L4Provide universal sorbents 15x19”, absorption capacity 26 gal, qty 1005ea
6312L5Provide hazmat sorbent for corrosive liquids, acids/bases, 15x19”, absorption capacity 30 gal, qty 1005ea
6312L6Provide extra large disposable nitrile gloves, powder free, 6 mil, Length 11.5-10.5", unlined, rolled cuff, special features ambidextrous, qty 1005ea
6312L7Provide large disposable nitrile gloves, powder free, 6 mil, length 11.5-10.5", unlined, rolled cuff, special features ambidextrous, qty 1005ea
6312L8Provide medium disposable nitrile gloves, powder free, 6 mil, length 10-10.5", unlined, rolled cuff, special features ambidextrous, qty 1005ea
6312M1Provide container, 8ft fiber fluorescent light tube (capacity 70) UN 1G/Y50/S1ea
6312M2Provide container, 4ft fiber fluorescent light tube (capacity 85) UN 1G/Y50/S1ea
6321Provide and prepare lab packs, consisting of small quantity chemicals (55 gal) (See 3.7)50ea
6322Provide and prepare lab packs, consisting of small quantity chemicals (20-30 gal) (See 3.7)25ea
6323Provide and prepare lab packs, consisting of small quantity chemicals (5-15 gal) (See 3.7)30ea
6330Expedited removal - 15 days (See 1.2.11)10ea
6331Expedited removal - 10 days (See 1.2.11)2ea
6332Expedited removal - 7 days (See 1.2.11)2ea
6333Expedited removal - 5 days (See 1.2.11)2ea
6334Expedited removal - 3 days (See 1.2.11)5ea
6335Expedited removal - 1 day (See 1.2.11)1ea
6340Expedited performance - 15 days (See 1.2.11)10ea
6341Expedited performance - 10 days (See 1.2.11)2ea
6342Expedited performance - 7 days (See 1.2.11)2ea
6343Expedited performance - 5 days (See 1.2.11)2ea
6344Expedited performance - 3 days (See 1.2.11)5ea
6345Expedited performance - 1 day (See 1.2.11)1ea
6350AATank cleaning/services – above ground, 1 to 999 gallon capacity (See 3.2)3ea
6350BBTank cleaning/cervices – above ground, 1,000 to 3,000 gal capacity (See 3.2)3ea
6350CCTank cleaning/services – above ground, 3,001 to 6,000 gal capacity (See 3.2)3ea
6350DDTank cleaning/services – above ground, 6,001 to 12,000 gal capacity (See 3.2)1ea
6351AATank cleaning/services – below ground, 1 to 999 gal capacity (See 3.2)3ea
5351BBTank cleaning/services – below ground, 1,000 to 3,000 gal capacity (See 3.2)3ea
6351CCTank cleaning/services – below ground, 3,001 to 6,000 gal capacity (See 3.2)3ea
6351DDTank cleaning/services – below ground, 6,001 to 12,000 gal capacity (See 3.2)1ea
6352AATank cleaning/services – oil/water separator, 1 to 999 gal capacity (See 3.2)3ea
6352BBTank cleaning/services – oil/water separator, 1,000 to 3,000 gal capacity (See 3.2)3ea
6352CCTank cleaning/services – oil/water separator, 3,001 to 6,000 gal capacity (See 3.2)3ea
6352DDTank cleaning/services – oil/water separator, 6,001 to 12,000 gal capacity (See 3.2)1ea
6355FBProvide service to inflate fuel bag (See 3.15)6ea
6371Provide rolloff (15 CD) (See 3.6)1ea
6372Provide rolloff (20 CD) (See 3.6)1ea
6373Provide rolloff (25 CD) (See 3.6)3ea
6374Provide rolloff (30 CD) (See 3.6)2ea
6375Provide rolloff (40 CD) (See 3.6)1ea
6400TSPerform appropriate analysis to properly identify unknown hazardous property and complete waste profile form (See 3.5)12ea
6400AAPrepare waste profile form (See 3.4)12ea
6401Perform hazardous waste characteristics analysis to determine ignitability (D001), corrosivity (D002), & reactivity (D003) (See 3.3)25ea
6402Perform total TCLP analysis (D0004-D043) (See 3.3)25ea
6403Perform TCLP metals analysis to determine 8 TCLP metals (D004-D011) (See 3.3)3ea
6404Perform TCLP analysis to determine D012-D017 (See 3.3)1ea
6405Perform TCLP analysis to determine volatile and semivolatile organics (D018-D043) (See 3.3)1ea
6406Perform F-series solvent analysis to determine EPA waste codes F001-F005 (See 3.3)1ea
6407Perform halogenated organic compound analysis to determine 106 HOCs listed in 22 CCR 66268, Appendix III (See 3.3)5ea
6408Perform total organic halogens analysis (See 3.3)1ea
6409Perform total petroleum hydrocarbons analysis (See 3.3)12ea
6411Perform volatile organics analysis (EPA Method 8240) (See 3.3)1ea
6412Perform analysis to determine physical characteristics (physical state, color, and density) (See 3.3)1ea
6413Perform analysis to determine halogenated volatile organics (EPA Method 8101) (See 3.3)1ea
6414Perform wastewater/nonwastewater determination in accordance with 40 CFR Part 268.2 (See 3.3)1ea
6415Perform BTU and % chlorine analysis (See 3.3)1ea
6416Perform test for the percentage of total chlorine (See 3.3)1ea
6417Perform test for semi-volatile organics as listed in 22 CCR 66268, Appendix III (See 3.3)1ea
6418Provide incineration and stabilization of lab packs, non-lab packed wastes, non-regulated wastes, and soil samples (in accordance with 40 CFR 268 Appendix IV and for solid wastes not subject to regulations under 40 CFR 261) (See 3.3)1ea
6419Perform paint filter test (EPA Method 9095) (See 3.3)1ea
6420Perform the following tests: EPA 8080 PCBs and organochlorine pesticides, EPA 8140 organophosphorous pesticides, EPA 8240 volatile organics, EPA 8270 semi-volatile organics, EPA 9010 cyanides, TCLP metals (8), & CCR TTLC (17) metals. If results of TTLC are 10 times greater than STLC, then run STLC (See 3.3)1ea
6421Perform test for asbestos (See 3.3)1ea
6422Perform analysis to determine benzene, toluene, ethylbenzene, and xylene (See 3.3)1ea

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .