This document is an Asbestos Management Plan containing an assessment of asbestos-containing building materials (ACBM) in Building 67 at the Defense Distribution Susquehanna Pennsylvania (DDSP) site. The assessment details the type, location, condition, and hazard ranking of the ACBM, which includes 600 square feet of friable 12"x12" floor tile. The overall hazard assessment ranking is 5, indicating the ACBM is damaged and has the potential for damage. The plan recommends applying a coat of wax to the floor tile.

This assessment is related to a federal contract opportunity for a Construction Requirements Contract at the DDSP site. The contract is a 5-year multiple award Indefinite Delivery/Indefinite Quantity (ID/IQ) contract with a total ceiling value of $45 million. The work will include various construction, alteration, maintenance, and repair efforts. The contract will be a 100% small business set-aside with reservations for WOSB, SDVOSB, and HUBZone concerns. Award is anticipated around August 2024.

View the file

Other files

File Type Posted
ATTACHMENT 1 - A0002 - Bldg 67 Revised Dwgs.pdf PDF
ATTACHMENT 3 - A0002 - 4232 Submittal Register Rev 01.pdf PDF
ATTACHMENT 2 - A0002 - BLDG 67 -Orig Constr Extract.pdf PDF
SP330024R0002 A0001.pdf PDF
Site Visit Notes 6-21-2024.pdf PDF
SP330024R0002 SITE VIST ATTENDANCE SHEET.pdf PDF
ATTACHMENT 8 - Blank Payment request.xlsx XLSX spreadsheet
ATTACHMENT 2 - Pre-enrollment Photos - 5 Pages.pdf PDF
ATTACHMENT 7 - Change Order Proposal Format.xlsx XLSX spreadsheet
ATTACHMENT 12 - Task Order 0001 Project Number 4232 Specifications - 457 Pages.pdf PDF
ATTACHMENT 1- - 1818 Pre-enrollment sample - 1 Page.pdf PDF
ATTACHMENT 3 - SF24-16e - BID BOND - 2025 - 2 Pages.pdf PDF
ATTACHMENT 13 - Task Order 0001 Project Number 4232 Submittal Registers - 4 Pages.pdf PDF
ATTACHMENT 10 - Construction Wage Requirement for Task Oder 0001 - 8 Pages.pdf PDF
SP330024R0002 6-6-2024.pdf PDF
ATTACHMENT 5 - SF25A-16e - PAYMENT - 2025 - 2 Pages.pdf PDF
ATTACHMENT 15 - Past Performance Questionnaire - 5 Pages.docx DOCX document
ATTACHMENT 6 - MASTER SPECIFICATIONS 11272023 - 2125 Pages.pdf PDF
ATTACHMENT 11 - Task Order 0001 Project 4232 Drawings - 22 Pages.pdf PDF
ATTACHMENT 4 - SF25-16e - PERFORMANCE - 2025 - 2 Pages.pdf PDF
ATTACHMENT 9 - Task Order 0001 Notice of Proposed Task Order Request For Proposal Form - 5 Pages.pdf PDF
ATTACHMENT 14 - 24-29 MATOC Eng_Form_4025_2017May - 2 Pages.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Defense Distribution Susquehanna Pennsylvania

Recording Form for ACBM Physical and Hazard Assessment Data

Date: 4/18/13 Inspector Initials: TJO/DJH

1 2 3 4 5 6 7

Building Number: 67 Building Use: Admin General Purpose

Functional Space: Admin/Common Areas Location: 1001

Type of ACBM/Assumed ACBM: Surfacing TSI Miscellaneous

Description: 12”x12” Floor Tile, White, Gray Streaks

Approximate Amount of Material (linear or square feet): 600 ft2

Friability: Friable Nonfriable

Condition:

Percent Damage: 0‐1% Localized Distributed

Type of Damage: Deterioration Water Physical

Description: None

Overall Rating: Good Damaged Significantly Damaged

Potential for Disturbance:

Frequency of Potential Contact: High Moderate Low

Description:

Influence Of Vibration: High Moderate Low

Potential for Air Erosion: High Moderate Low

Overall Rating: Potential for Potential for Low Potential Significant Damage Damage

AHERA Hazard Assessment Ranking:

(See back for key)

Comments: Apply coat of wax

Signed: Date: 5/7/13 x x x x x x x x

AHERA Hazard Assessment Rankings

Hazard Rank ACBM Condition ACBM Disturbance Potential

7 Significantly Damaged Any

6 Damaged Potential for Significant Damage

5 Damaged Potential for Damage

4 Damaged Low

3 Good Potential for Significant Damage

2 Good Potential for Damage

1 Good Low

D-51

DEFENSE DISTRIBUTION CENTER, SUSQUEHANNA | ASBESTOS MANAGEMENT PLAN

Table D.2 Confirmed/Assumed ACM in 57 Buildings: Pre-2000 through 2007 Construction (Continued)

BLDG 67 - DDSP Assessment Data 2013_081613
BLDG 67 - DDSP Assessment Dtrm_081613