MIL-PRF-27415B 1 .pdf

Performance Specification Rev. B PDF 270 KB Posted

Attached to
LIQUID ARGON
Solicitation number
SP0600-10-R-0319
Issued by

About this file

Performance Specification Propellant Pressurizing Agent Argon MIL-PRF-27415B (Attachment 1)

View the file

Other versions and copies of MIL-PRF-27415B

Who attaches MIL-PRF-27415B

Other files

File Type Posted
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
SP0600-10-R-0319 Liquid Argon.pdf PDF
small business subcontracting plan.pdf PDF
H-14 TRANSPORT EQUIPMENT DELAY CERTIFICATE.pdf PDF
Contractor Performance.doc DOC document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MIL-PRF-27415B

08 February 2007

SUPERSEDING

METRIC

MIL-PRF-27415A

11 December 1997

PERFORMANCE SPECIFICATION

PROPELLANT PRESSURIZING AGENT, ARGON

This specification is approved for use by all Departments and Agencies of the Department of Defense.

Comments, suggestions, or questions on this document should be addressed to HQ-AFPET/AFTT, 2430 C Street, Bldg 70, Area B, Wright-Patterson AFB, OH, 45433-7632 or e-mailed to AFPET.AFTT@wpafb.af.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at http://assist.daps.dla.mil.

AMSC N/A FSC 9135

DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.

ATTACHMENT 1

mailto:AFPET.AFTT@wpafb.af.mil http://assist.daps.dla.mil/

1. SCOPE

1.1 Scope. This specification covers the requirements for two grades and two types of argon.

1.2 Classification. The argon will be of the following types and grades as specified (see 6.2):

1.2.1 Types. The types of argon are as follows:

Type I - Gaseous

Type II - Liquid

1.2.2 Grades. The grades of argon are as follows:

Grade A - 99.998 percent purity

Grade B - 99.985 percent purity

2. APPLICABLE DOCUMENTS

2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed.

2.2 Government documents.

2.2.1 Other Government documents, drawings, and publications. The following Government document forms a part of this document to the extent specified herein. Unless otherwise specified, the issue of this document is the one cited in the solicitation or contract (see 6.2).

NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY (NIST) Formerly the National Bureau of Standards (NBS)

Technical Publication Thermodynamic Properties of Argon from the Triple Point to NSRDS-NBS 27 300K at Pressures to 1000 Atmospheres

(Copies of this document are available online at http://www.nist.gov or the National Institute of Standards and Technology (NIST), 100 Bureau Drive, Stop 1070, Gaithersburg, MD 20899-1070.)

2.3 Non-government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.

ASTM INTERNATIONAL

ASTM E 29 Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications

ASTM F 307 Standard Practice for Sampling Pressurized Gas for Gas Analysis

ASTM F 310 Standard Practice for Sampling Cryogenic Aerospace Fluids

(Copies of these documents are available online at http://www.astm.org or the American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken PA 19428-2959)

ATTACHMENT 1

http://www.nist.gov/ http://www.astm.org/

COMPRESSED GAS ASSOCIATION (CGA)

CGA G-11.1 Commodity Specification for Argon

CGA P-15 Filling of Industrial and Medical Nonflammable Compressed Gas Cylinders

(Copies of these documents are available online at http://www.cganet.com or the Compressed Gas Association, Inc., 4221 Walney Road, 5th floor, Chantilly, VA 20151-2923)

2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein (except for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.

3. REQUIREMENTS

3.1 Composition. The composition of the argon shall conform to the limits in Table I when tested in accordance with the applicable test methods (see 4.4). Other limits and tests may be specified by the procuring activity (see 6.2).

3.2 Limiting values. The following applies to all specified limits in this specification: For purposes of determining conformance with these requirements, an observed value or a calculated value shall be rounded off "to the nearest unit" in the last right-hand digit used in expressing the specification limit according to the rounding-off method of ASTM E 29, Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications.

3.3 Filter. A filter with a rating of at least 10-micrometer nominal and 40-micrometer absolute or better shall be installed between the manufacturer’s plant system and the manifold used to fill the gas or liquid containers for delivery.

3.4 Filled containers (Type I only).

3.4.1 Pressure. The container filling pressure shall not differ from that required by the contract by more than 1% at 70°F when tested as specified in 4.5.1. In no case shall the filling pressure exceed the rated service pressure of the container. Gas cylinders shall be filled to within 99 to 100 percent of their rated service pressure when tested as specified in 4.5.1. Pressure-Temperature Filling Charts in CGA P-15 or the pressure-temperature table in Section 6 may be used.

3.4.2 Leakage. Cylinders shall not leak when tested according to 4.5.2.

ATTACHMENT 1

http://www.cganet.com/

TABLE I Composition

Grades Test Paragraph

Composition

A B

Assay (purity), Argon (Ar) percent by volume, min

99.998 99.985 4.4.1

Water, ppm by volume, max

Dewpoint, °C (°F)

Oxygen, ppm by volume, max

Hydrogen, ppm by volume, max

Nitrogen, ppm by volume, max

Total hydrocarbons (as methane), ppm by volume, max

Carbon dioxide, ppm by volume, max

3.5

-68 (-90)

0.5

0.5

-54 (-65)

Not specified

Not specified

4.4.2

4.4.2

4.4.2

4.4.2

4. VERIFICATION

4.1 Points of inspection (see 6.2).

4.1.1 Containers. Unless otherwise specified, acceptance tests shall be conducted at the site of filling prior to shipment or departure.

4.2 Conformance inspection. Quality conformance tests shall consist of the following:

a. Individual tests (Type I only)................................ 4.2.1

b. Sampling tests .................................................... 4.2.2

4.2.1 Individual tests (Type I only). Each container shall be subjected to the following tests as described under 4.5:

a. Filling pressure .................................................... 4.5.1

b. Leakage .............................................................. 4.5.2

4.2.2 Sampling test. The number of argon containers shall be selected in accordance with Table II and subjected to the tests required by Table I.

TABLE II. Sampling for test.

Number of containers in lot Number of containers to be sampled

1 1

2 – 40 2

41 – 70 3

71 – over 4

4.2.3 Lot definitions.

4.2.3.1 Type I. A lot is defined as all of the argon supplied in one or more container(s) filled from a single manifold at the same time.

4.2.3.2 Type II. Each filled container shall constitute a lot.

4.2.3.3 Container Assemblies. A shipping conveyance consisting of multiple cylinders or tubes that are interconnected by a single manifold that equalizes the pressure across all cylinders/tubes to form a single unit is considered a single container.

4.2.4 Sample. Each sample shall be of sufficient size to conduct all the quality conformance tests as specified herein. Unless otherwise specified, the quality conformance tests shall be performed on each required sample (see 6.2). When required, an equivalent sample shall be forwarded to a laboratory designated by the procuring activity for subjection to the quality conformance tests specified herein.

4.2.4.1 Sampling methods. Each sample taken for analysis shall be representative of the entire contents of the container being sampled. All equipment used shall be made of suitable materials. Unless otherwise specified in the acquisition requirements (see 6.2), sampling shall be accomplished by one of the following methods.

a. Type I, gaseous argon may be sampled in accordance with ASTM F 307 and Type II, liquid argon may be sampled in accordance with ASTM F 310. It is critical that the sampling port be clean and free of contaminants.

b. Connect the shipping container being sampled directly to the analytical equipment using suitable pressure regulation as required to prevent over-pressurization of the equipment.

4.2.5 Non-Bulk Containers. The number of containers filled with Type I (gaseous) argon selected for sampling from each lot shall be in accordance with Table II. The first and last containers to be filled within a given lot are typically sampled. Other samples may be selected at random. Every container filled with Type II (liquid) argon shall constitute a lot and will be sampled.

4.2.6 Bulk transports. For bulk shipments, each container filled with Type I (gaseous) or Type II (liquid) argon constitute a lot and shall be sampled.

4.3 Rejection. When any sample tested in accordance with 4.4 fails to conform to the requirements specified herein, the entire lot represented by the sample shall be rejected.

4.4 Analytical procedures. Unless otherwise specified (see 6.2), samples shall be analyzed according to the procedures described in 4.4.2. Calibration gas standards may be required to calibrate (zero and span) analytical instruments used to determine the purity and impurity contents of the argon.

The accuracy of the calibration gas standards is to be traceable to the National Institute of Standards and Technology (NIST).

4.4.1 Argon content. The argon content in percent shall be found by determining the aggregate impurities by the methods described in 4.4.2. The aggregate impurities shall include all the impurities listed in Table I, regardless of Grade. The percent argon is the value obtained when the aggregate impurities, expressed as volume percent, are subtracted from 100 percent.

4.4.2 Impurities. The analytical procedures described in CGA G-11.1 shall be used to determine the concentrations of those impurities listed in Table I.

4.5 Filled container tests (Type I only).

4.5.1 Filling pressure. Containers shall be tested for proper filling pressure by attaching a calibrated Bourdon-tube or equivalent gauge to the valve outlet and by attaching either a thermocouple or thermometer to the container wall. The gauge shall have scale divisions not greater than 100 kPa (15 psi) for service pressures of less than or equal to 25 MPa gauge (3626 psig). For service pressures greater than 25 MPa gauge (3626 psig), a maximum of 700 kPa (100 psi) per scale division is acceptable.

If a thermometer is used, tape or putty shall be applied to the bulb to protect it from extraneous temperatures. Putty shall not be applied between the bulb and the container wall. The thermometer shall not have scale divisions greater than 1°C (2°F). The containers shall be stabilized to ambient temperature. Then the valve shall be opened and the internal pressure observed on the gauge.

4.5.2 Leakage. Each Type I argon container shall be tested for leaks at the neck threads, stem packing, and safety device of the valve with leak-detection fluid. Valve seat leakage shall be tested after filling has been completed by connecting a hose to the valve outlet and placing the other end of the hose under the surface of a liquid.

5. PACKAGING

5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When actual packaging of materiel is to be performed by DoD or in-house contractor personnel, these personnel need to contact the responsible packaging activity to ascertain packaging requirements. Packaging requirements are maintained by the Inventory Control Point’s packaging activities within the Military Service or Defense Agency, or within the military service’s system commands. Packaging data retrieval is available from the managing Military Department’s or Defense Agency’s automated packaging files, CD-ROM products, or by contacting the responsible packaging activity.

6. NOTES

(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)

6.1 Intended use. The argon is used as a welding, purging, pressurizing, atmospheric inerting agent, or missile checkout gas in various systems.

6.2 Acquisition requirements. Acquisition documents must specify the following:

a. Title, number, and date of this specification.

b. Type and grade of argon required (see 1.2).

c. If required, the specific issue of individual documents referenced (see 2.2.1).

d. When other limits or tests are required (see 3.1).

e. When a variation in the points of inspection is required (see 4.1).

f. When a variation of the quality conformance tests to be performed on a sample is required (see 4.2.4).

g. When a variation to the sampling method is required (see 4.2.4.1).

h. When a variation of the analytical procedures is required (see 4.4).

i. Packaging requirements (see 5.1).

6.3 Packaging requirements. Guidance for cylinders may be found in the following documents:

a. MIL-DTL-2/11 Valve, Cylinder, Gas: Argon, Helium, Nitrogen, Neon, and Xenon, (Inert-Oil Free), Outlet 580

b. MIL-DTL-2/51 Valve, Cylinder, Gas: Argon, Helium, Nitrogen, Neon, Xenon, and Krypton (Inert-Oil Free), Outlet 677

c. MIL-STD-101 Color Code for Pipelines and for Compressed Gas Cylinders

d. MIL-STD-1411 Inspection and Maintenance of Compressed Gas Cylinders

e. 49 CFR 171 – 199 Code of Federal Regulations

6.4 Field use limits. The requirements established by this specification are applicable for procurement purposes only and are valid solely as utilized by vendor and the procuring activity. They are not intended for each application.

6.5 Particulate contamination. Long term storage of filled argon containers may allow particulate contaminants to accumulate. For this reason, the installation of in-line filters between the containers and system if applicable, is recommended prior to use. Filters with a rating of five micrometer nominal and 25 micrometer absolute rating or better for Type I (gaseous) and with a 10 micrometer nominal and 40 micrometer absolute rating or better for Type II (liquid) are suggested.

6.6 Part or identifying number. The PINs to be used for argon acquired to this specification are created as follows:

M 27415 - X X Example of PIN: M27415-2B

Grade (1.2.2).

Type (1.2.1). Use 1 for Type I, 2 for Type II.

Specification number.

Prefix for military specification.

6.7 Subject term (key word) listing.

Aerospace Cylinders Argon Propellant Missile checkout Welding gas Inerting agent

6.8 International standardization agreement implementation. This specification serves as the implementing document for STANAG 7127 GGS. MIL-PRF-27415, Grade A, argon, meets the requirements of the argon specified in STANAG 7127. When the amendment, revision, or cancellation of this specification is proposed, the preparing activity must coordinate the action with the U.S. National Point of Contact for the international standardization agreement, as identified in the ASSIST database at http://assist.daps.dla.mil.

6.9 Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes.

TABLE III. Pressure temperature conversion chart container service pressure – 6000 psig. 1

TEMP °F PSIG TEMP °F PSIG TEMP °F PSIG

0 4567 44 5469 88 6366 2 4608 46 5510 90 6407 4 4649 48 5551 92 6448 6 4690 50 5592 94 6488 8 4731 52 5633 96 6529 10 4772 54 5674 98 6570 12 4813 56 5714 100 6610 14 4854 58 5755 102 6651 16 4895 60 5796 104 6691 18 4936 62 5837 106 6732 20 4978 64 5878 108 6772 22 5019 66 5918 110 6813 24 5060 68 5959 112 6853 26 5101 70 6000 114 6894 28 5142 72 6041 116 6935 30 5183 74 6081 118 6975 32 5224 76 6122 120 7016 34 5265 78 6163 122 7056 36 5305 80 6204 124 7096 38 5346 82 6244 126 7137 40 5387 84 6285 128 7177 42 5428 86 6326 130 7218 Note 1: Calculated from the equation of state for argon of A. L. Gosman, et al. See NBS Technical Publication NSDRS-NBS 27 (Available through NIST).

http://assist.daps.dla.mil/

CONCLUDING MATERIAL

Custodians: Preparing activity:

Army – MI Air Force – 68 Navy – AS (Project 9135-2005-005) Air Force – 68

DLA – PS

Review activities:

Air Force – 19

Note: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information using the ASSIST Online database at http://assist.daps.dla.mil.

http://assist.daps.dla.mil/

TABLE I Composition
TABLE II. Sampling for test.
TABLE III. Pressure temperature conversion chart� container

File details come from the government source that posted it. Updated .