PRODUCT PRESSURE AND FLOW RATE/TANK DESCRIPTION
ATTACHMENT 1
PRODUCT STORAGE
CAPACITY
# OF
STORAGE
TANKS
ROUTINE DELIVERY
– MINIMUM psig
AT TIME OF OFF-
LOAD
MAWP MINIMUM
PRESSURE TO
SIGNAL
REPLENISHMENT
DESCRIPTION OF STORAGE
TANK
HOSES/CONNECTOR
INFORMATION
Liquid Oxygen, LOX
900 gallons (approx.
4.29 tons)
2 Filled to operating capacity when filled
500 psig 50 “inches of water”
a. Designed as a cryogenic tanks.
b. The tanks are no higher than 11.5 feet above grade.
c. Tanks are compliant with ASME UPV Code Section VIII, Division 1.
d. The tanks are supplying 1,400 SCFH of oxygen on a 5 day a week/ 16 hour basis.
e. Located in Bldg 3001
a. Contractor shall provide off-load hoses with a minimum length of 25 feet.
b. The fill connections available to the Contractor are standard industrial CGA bulk fittings.
c. Contractor shall ensure proper interface between tanks and offloading unit.
FXS0199
Typewritten Text
FXS0199
Typewritten Text
FXS0199
Typewritten Text
FXS0199
Typewritten Text
# OF
STORAGE
TANKS
ROUTINE DELIVERY
– MINIMUM psig
AT TIME OF OFF-
LOAD
MAWP MINIMUM
PRESSURE TO
SIGNAL
REPLENISHMENT
DESCRIPTION OF STORAGE
TANK
HOSES/CONNECTOR
INFORMATION
Gaseous Hydrogen, GH2
120,000 scf 1 2,000 psig 4,000 psig
Start with 1000 psi and adjust if needed from historical data.
Delivery time will also impact the pressure fill setting.
a. Designed as a series of high pressure tanks.
b. Approximately 20 feet in length, mounted horizontally and no greater than 11 feet high.
c. Tanks are compliant with ASME UPV Code Section VIII, Division 1, and Appendix 22
d. Compatible with operation at minus 20 degrees F to 200 degrees F.
e. Tanks are connected to two separate regulated supplies to the building, one of the supplies is regulated to 250 psig and the other is regulated to 150 psig.
with a minimum length of 25 feet.
b. The fill connections available to the Contractor are standard industrial CGA bulk fittings.
c. Contractor shall ensure proper interface between tanks and offloading unit.
# OF
STORAGE
TANKS
ROUTINE DELIVERY
– MINIMUM psig
AT TIME OF OFF-
LOAD
MAWP MINIMUM
PRESSURE TO
SIGNAL
REPLENISHMENT
DESCRIPTION OF STORAGE
TANK
HOSES/CONNECTOR
INFORMATION
Liquid Nitrogen, LN2
900 gallons (approx.
3.04 tons)
Filled to operating capacity when filled
250 psig 30 “inches of water”
a. Designed as a cryogenic tanks.
b. The tanks are no higher than 11.5 feet above grade.
c. Tanks are compliant with ASME Code Section VIII, Division 1.
d. The tank is supplying 556 SCFH of nitrogen on a 5 day a week/ 16 hour basis.
with a minimum length of 25 feet.
b. The fill connections available to the Contractor are standard industrial CGA bulk fittings.
c. Contractor shall ensure proper interface between tanks and offloading unit.
**MAWP (Maximum Allowable Working Pressure)
Other files
| File | Type | Posted |
|---|---|---|
| Transport Equip Delay Cert H-14 | — | |
| CGA G-10.1_7 Nitrogen | — | |
| Past Performance Data Sheet | — | |
| CGA G-5.3 2004 Hydrogen | — | |
| LOX MIL-PRF-25508G | — | |
| TAFB Solicitation.pdf |