SOW_Replace_Quarters_18_Windows.pdf
PDF 221 KB Posted
- Attached to
- WY-JACKSON NFH-QRTS 18 DOOR WINDOW RPLCM
- Solicitation number
- 140FGA26R0043
About this file
This is a Statement of Work (SOW) for the replacement of windows and front/back doors at Jackson National Fish Hatchery located at 1500 E Fish Hatchery Rd, Jackson, WY 83001. The project objective is to provide a more efficient climate-controlled living space for an employee by removing existing windows and doors and installing new units with storm doors.
The contractor must be appropriately licensed and certified within Wyoming and comply with all federal, state, and county regulations and laws. Work must be completed by November 15, 2026, during normal duty hours (Monday-Friday, 8:00 a.m. to 4:30 p.m.). The scope includes removal and legal disposal of current windows and doors, and installation of nine specified V400 Tuscany windows with precise dimensions and performance specifications (U-Factor: .25-.28, SHGC: .25-.27, Low-E coatings, STC ratings 29-30) in various configurations totaling 3 units at 72" x 47¾", 1 unit at 98" x 47¾", 1 unit at 27¾" x 38¾", 1 unit at 31¾" x 47", 3 units at 35⅞" x 47¾", and 1 unit at 71¾" x 47¾". The contractor shall replace the front door with a 3/0 x 6/8 Therma-Tru S206-LE left-hand inswing door with Tru-D composite sill and install an Andersen 3000 storm door with retractable screen (left-hand opening). The back door shall be replaced with a 2/8 x 6/8 Therma-Tru S601-LE right-hand inswing door with similar specifications and an Andersen 3000 storm door (right-hand opening). The contractor must provide all materials required for proper installation. Jackson NFH will furnish restrooms, electricity, and water. Technical coordination is provided by Travis Anderson (Hatchery Manager) and Kristopher Johnson (Facility Management Coordinator).
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Notice_to_Offerors_.pdf | ||
| Wage_Determination.pdf | ||
| Sol_140FGA26R0043.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK (2026 06 24)
Jackson National Fish Hatchery
Replacement of Windows and Front/Back Doors
1. General:
1.1 Jackson NFH 1500 E Fish Hatchery Rd Jackson WY 83001. Service, remove and dispose of current windows, and install new windows. Remove and install new front and back doors. Install storm doors on the front and back doors.
1.2 Purpose/End Application: This project is to provide a more efficient climate-controlled living space for the employee.
1.3 Contractor Qualifications: The contractor must be appropriately licensed and certified within the state of Wyoming for the specified services.
1.4 Other: The contractor must follow all associated regulations and laws including: Federal, State, and County.
2. Place of Performance and Period of Performance
2.1 Work is to be performed at Jackson NFH 1500 E Fish Hatchery Rd Jackson WY 83001
2.2 This project needs to be completed prior to November 15, 2026.
2.3 Normal duty hours Monday thru Friday 8:00 a.m. - 4:30 p.m. In the event of emergencies, Contractor shall provide contact information.
2.4 Non-duty hours include weeknights, weekends, and Government holidays (New Year’s Day, Martin Luther King JR.s’s Birthday, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veteran’s Day, Thanksgiving Day, Christmas Day).
3. Scope
3.1 The contractor shall remove and legally dispose of current windows.
3.2 The contractor shall replace the windows with the following or equivalent windows:
a. Net Frame: 72” x 47 ¾” (3 each) V400 Tuscany, 8220T, DSH, 1 3/8" Setback, Ext Espresso / Int White 1/8" SunCoat (Low-E) over 1/8" 4th
Surface HP Coating with Gray
EdgeGardMAX Spacer U-Factor: .28, SHGC: .27, VT: .51
STC: 29, OITC: 24, PG: R-PG30
b. Net Frame: 98” x 47 ¾” (1 each)
V400 Tuscany, 8220T, DSHPW, 1 3/8" Setback, Ext Espresso / Int White 1/8" SunCoat (Low-E) over 1/8" 4th Surface HP Coating with Gray EdgeGardMAX Spacer
STC: 29, OITC: 24, PG: LC-PG25
c. Net Frame: 27 3/4” x 38 3/4” (1 each)
V400 Tuscany, 8520T2, FC, 1 3/8" Setback, Ext Espresso / Int White 1/8" SunCoat (Low-E) over 1/8" 4th Surface HP Coating with Gray EdgeGardMAX Spacer U-Factor: .25, SHGC: .25, VT: .46
STC: 30, OITC: 24, PG: LC-PG60
d. Net Frame: 31 3/4"” x 47” (1 each)
V400 Tuscany, 8220T, SH, 1 3/8" Setback, Ext Espresso / Int White 1/8" SunCoat (Low-E) over 1/8" 4th Surface HP Coating with Gray EdgeGardMAX Spacer
STC: 29, OITC: 24, PG: LC-PG40
e. Net Frame: 35 7/8” x 47 3/4” (3 each)
V400 Tuscany, 8220T, SH, 1 3/8" Setback, Ext Espresso / Int White 1/8" SunCoat (Low-E) over 1/8" 4th Surface HP Coating with Gray EdgeGardMAX Spacer
STC: 29, OITC: 24, PG: LC-PG40
f. Net Frame: 71 3/4” x 47 3/4” (1 each)
V400 Tuscany, 8220T, DSH, 1 3/8"
Setback, Ext Espresso / Int White 1/8" SunCoat (Low-E) over 1/8" 4th Surface HP Coating with Gray EdgeGardMAX Spacer
STC: 29, OITC: 24, PG: R-PG30
3.3 The contractor shall remove and legally dispose of front and back doors.
3.4 The contractor shall replace the front door same or equivalent to:
a. 3/0 x 6/8 - Left Hand Inswing (1A) - S206-LE - Exterior Therma-Tru Single Prehung
b. 3/0 x 6/8 Smooth-Star Half Lite 2 Panel Clear Lite No Grilles Scrolled Lite Frame
c. Low-E - Double Bore (Lockset w/ Deadbolt) 2 3/4" - Mortise (Radius Corner) Edge
d. Prep - Deadbolt Frame Prep 1-1/8" x 2-3/4" (660) - Custom Jamb Width 7" – 7
e. 1/4" Primed Jamb - Bronze Weatherstrip - Primed Brickmould - Apply Brickmould
f. Mill Tru-D Composite Adjustable Sill - Brushed Nickel (US15) 5/8" Radius x Square
LH
g. Self Aligning Ball-Bearing Hinges
3.5 The contractor shall install a storm door at the back door same as or equivalent to:
a. Andersen 3000 Storm door with retractable screen
b. Left hand opening
3.6 The contractor shall replace the back door same or equivalent to:
a. 2/8 x 6/8 - Right Hand Inswing (1B) - S601-LE - Exterior Therma-Tru Single Prehung
b. 2/8 x 6/8 Smooth-Star Craftsman Lite 2 Panel Craftsman Clear Lite No Grilles
c. Scrolled Lite Frame Low-E - Double Bore (Lockset w/ Deadbolt) 2 3/4" - Mortise
d. (Radius Corner) Edge Prep - Deadbolt Frame Prep 1-1/8" x 2-3/4" (660) - 6 9/16"
e. Primed Jamb - Bronze Weatherstrip - Primed Brickmould - Apply Brickmould - Mill
f. Tru-D Composite Adjustable Sill - Brushed Nickel (US15) 5/8" Radius x Square RH
g. Self-Aligning Ball-Bearing Hinges
3.7 The contractor shall install a storm door at the back door same as or equivalent to:
c. Andersen 3000 Storm door with retractable screen
d. Right hand opening
4. Deliverables and/or Delivery Schedule:
4.1 The contactor shall provide windows and doors same as or equivalent to the ones mentioned above.
4.2 The contractor shall provide all associated materials required for proper installation.
5. Data Management Plan (DMP) N/A
6. Government-Furnished Equipment (GFE) / Government-Furnished Information
(GFI)
6.1 Jackson NFH will provide restrooms, electricity, and water for the contractor to use while the contracted work is being completed.
6.2 Identify any limitations. N/A
7. Technical Coordinator:
Primary individual responsible for the final product or service.
Travis Anderson Hatchery Manager 1500 E Fish Hatchery Rd Jackson, WY 83001 Office: 435-219-1672 travis_anderson@fws.gov
Secondary individual responsible for the final product or service.
Kristopher “Kris” Johnson Facility Management Coordinator (FMC) Asset Management Coordinator (AMC) U.S. Fish and Wildlife Service Fish and Aquatic Conservation (FAC) 1380 South 2350 West Vernal, UT 84078 Cell: 435-299-5150 Office: 435-789-0351 ext. 16 kristopher_b_johnson@fws.gov
File details come from the government source that posted it. Updated .