This Statement of Work (SOW) details repair requirements for Cockpit Control Display Units (CCDUs) manufactured by Mercury Systems, specifically models ACP9543 and ACP9533, used for airborne flight testing at Eglin Air Force Base. The document outlines multiple repair needs for specific CCDU units, including issues such as power switch failures, LCD screen damage, units not powering up, and communication/configuration problems. The technical requirements mandate that the contractor perform repairs on the listed units, verify proper functionality, and return the repaired equipment to the government, with the specific serial-numbered units requiring interventions ranging from power switch replacement to board rework and LCD screen repairs. The repair list includes nine distinct CCDUs with varying technical issues, all associated with the ACP9543-P02001 model number, and the work is to be completed in accordance with attached estimates and documentation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| NOCA signed(1).pdf | ||
| single_source_justification.pdf-Redacted.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
for
ACP9543 and ACP9533 CCDU Repairs
28 May 2025
1.0 INTRODUCTION
1.1 Background
The Cockpit Control Display Unit (CCDU) are made by Mercury Systems and are known by the vendor as model #s ACP9543 and ACP9533; they are used extensively by for airborne flight testing, and are in need of repair.
1.2 Scope
The ACP9543 and ACP9533 CCDUs have a variety of failures and are in need of repair
. IAW the attached estimates, these CCDUs are a critical part of the control system for the flight test instrumentation system on the majority of the test fleet at Eglin
AFB, FL.
2.0 APPLICABLE DOCUMENTS
The applicable documents below will be used under this effort.
• Please refer to excel spreadsheet (attached)
3.0 TECHNICAL REQUIREMENTS
At a minimum, the Contractor shall accomplish the requirements of this order through fulfilling the following specifications:
• Perform repairs to units and verify proper working order before returning to as outlined in the list of repairs below.
Repairs:
Repair Item Description Model number
Serial number
POWER SWITCH ACP9543-306 ACP9543-
P02001
18099543CP2054
LCD SCREEN 4.3QVGALEDSHP-4-
BOND-E
ACP9543-
P02001
19129543CP2061
CD: WILL NOT
POWER UP
AKP9543-1 ACP9543-
P02001
18089543CP2019
BROKEN LCD
SCREEN
4.3QVGALEDSHP-4-
BOND-E
ACP9543-
P02001
18089543CP2018
POWER SWITCH
IS BENT
ACP9543-306 ACP9543-
P02001
18089543CP2042