SOW_PRECISION PRESSURE CALIBRATOR_Redacted.pdf

PDF 274 KB Posted

Attached to
Precision Pressure Calibrators
Solicitation number
A019061
Issued by

About this file

This Statement of Work (SOW) details the procurement of Precision Pressure Calibrators for the Naval Surface Warfare Center, Corona Division. The contract is a five-year Indefinite Delivery/Indefinite Quantity (IDIQ) agreement to acquire between one and fifty calibration standards to modernize existing Navy Calibration Laboratories, replacing the current King Nutronics 3689A model. The new calibrators will offer a reduced footprint, enhanced logistical efficiency, and maintained capabilities while generating cost savings through reduced transportation, power consumption, and maintenance requirements.

Key contract requirements include providing operator/service manuals, a one-year manufacturer's warranty, calibration certificates traceable to the National Institute of Standards and Technology (NIST), calibration labels, repairable parts lists, software/firmware version descriptions, and comprehensive training materials. The deliverables will be provided in electronic media format on CD-ROM or DVD, with each system considered a Firm Fixed Price element. The required delivery timeline is 120 days after contract award, with the shipping address located in Beaufort, SC, and the technical point of contact at the NSWC Corona Division in Norco, CA.

View the file

Other files

File Type Posted
CSS 06-3236 Precision Pressure Calibrator_ver4.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 | 5

STATEMENT OF WORK

PRECISION PRESSURE CALIBRATOR

1. INTRODUCTION

2. BACKGROUND

3. SCOPE

4. APPLICABLE DOCUMENTS

Document Type/No.

Description Document Date

MIL-STD-

130N

Identification Marking of US Military Property https://quicksearch.dla.mil/qsDocDetails.aspx?ident_n umber=35521

November 2012

MIL-PRF-

28800G

Test Equipment for use with Electrical and Electronic Equipment https://quicksearch.dla.mil/qsDocDetails.aspx?ident_n umber=19684

November 2021

The Naval Surface Warfare Center, Corona Division, Measurement Science and Engineering Department perform Metrology, Test, and Monitoring Systems Assessment supporting the Naval Sea Systems Command Metrology and Calibration Program. Measurement Science and Engineering Department sets the measurement science and calibration standards to support proper weapons operation, interoperability and peak readiness for the fleet.

The existing Precision Pressure Calibrator across the Navy Calibration Laboratories are in need of modernization. The procurement of the Precision Pressure Calibrator is critical to address the logistical limitations of our current model, King Nutronics 3689A. New Precision Pressure Calibrators offer in lab configurations with reduced footprint that enhance logistical efficiency due to their size and weight reduction. This modernization maintains all existing capabilities of the current model while offering in lab convenience. This transition will enhance operational agility and flexibility, ultimately enabling greater mission success while generating cost savings through reduced transportation, power consumption, and maintenance requirements.

The scope of this effort is to procure via a five (5) year Indefinite Delivery/Indefinite Quantity (IDIQ) contract a minimum of one (1) and maximum of fifty (50) Precision Pressure Calibrators for the Navy fleet Calibration Laboratories.

2 | 5

MIL-PRF-

38793

Technical Manuals: Calibration Procedures - Preparation https://quicksearch.dla.mil/qsDocDetails.aspx?ident_n umber=22455

August 2008

MIL-

HDBK-

781A

Reliability Test Methods, Plans, and Environments for Engineering Development, Qualification, and Production.

https://quicksearch.dla.mil/qsDocDetails.aspx?ident n umber=54097

April 1996

NIST

Special Publication

Guide for the Use of the International System of Units (SI) https://www.nist.gov/pml/special-publication-811

March 2008

NIST

Technical Note 1297

Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results https://www.nist.gov/pml/nist-technical-note-1297

September 1994

3 | 5

5. REQUIREMENTS

Please refer to Attachment 1, CSS 06-3236 for specifications

5.1.1 The Contractor shall provide operator/service manual(s) required to be supplied with each calibration standard. At a minimum, these manual(s) shall contain information on operator/maintainer safety, theory of operation, troubleshooting, preventative maintenance, periodic maintenance, calibration, maintainability data, and operational instructions. The manuals can be either print or electronic media format on either CD-ROM or DVD disks.

(CDRL T001)

5.1.2 The Contractor shall ensure the units shall be provided with a manufacturer’s standard warranty, of one (1) year minimum after installation and acceptance by the Navy.

5.1.3 A calibration certificate with a report referencing actual data shall be provided by the vendor to the Government for each calibration standard installed. (CDRL A001)

5.1.4 Calibration of all new standards must be traceable to the National Institute of Standards and Technology (NIST) and result in an Accredited Certificate/Report of Calibration.

5.1.5 The Contractor shall provide a calibration label indicating the calibration interval shall be placed on each installed standard.

5.1.6 The Contractor shall provide a Repairable Parts list to the Government for each standard installed. (CDRL A002)

5.1.7 The Contractor shall provide a Software/Firmware Version Description to be provided with each system delivered. The Software/Firmware version shall be the same on all delivered systems. (CDRL A003)

5.1.8 The Contractor shall provide a step-by-step recorded training manual to be supplied with each calibration standard. Training shall include instructions on how to operate, maintain and calibrate the system. A complete review of all paragraphs in the operator/service manual provided under CDRL T001 shall be included in the training.

Instructions and demonstrations on all software functions and menu items resident on the system shall be included in the training. Instructions for periodic and incident based preventative maintenance shall be included. A demonstration of the calibration of the Precision Pressure Calibrator Standard shall be provided. The training manuals shall be an electronic media format on either CD-ROM or DVD disks. (CDRL A004)