This Statement of Work describes the acquisition requirements for medical telemetry equipment by the Robert J. Dole VA Medical Center in Wichita. The procurement is for 18 Philips IntelliVue MX-40 1.4 GHz Smart Hopping Telemetry Packs, wearable patient monitors designed to interface with the facility's existing Philips Patient Information Center (PIC) iX monitoring system (Revision C.02). This is a Name Brand Only acquisition, and like items will not be accepted due to the specific system compatibility requirements.

The MX-40 units must feature a 2.8-inch color touch-sensitive display, smart multi-measurement cable systems compatible with both reusable and single-patient use supplies, FAST or Masimo SET SpO2 measurement capability, configurable ECG lead systems (Standard, EASI, or Hexad), impedance-based respiration measurement, and a rechargeable lithium-ion battery pack. The devices must support 6-lead ECG with two V-leads for diagnosing cardiac abnormalities, local measurement trending and alarm history with graphical display, integrated radio for connection to the Information Center, and short-range radio communication with IntelliVue Patient Monitors. Installation is not required, but the contractor must provide technical support to VA staff for system connectivity. A minimum one-year manufacturer's warranty covering all parts, labor, accessories, and software is required, with the warranty period beginning only after the Wichita VA point of contact or designee accepts delivery, installation verification, and functionality confirmation.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK (SOW)

Philips IntelliVue MX-40 1.4 Ghz Smart Hopping Telemetry Packs

1. INTRODUCTION

The Robert J. Dole VA Medical Center seeks to acquire 18 Philips MX-40 IntelliVue 1.4 Ghz Smart Hopping Telemetry Packs. These wearable patient monitors/devices are needed to interface with the Philips Patient Information Center (PIC) iX monitoring system.

2. TECHNICAL REQUIREMENTS

This is a Name Brand Only acquisition. Items must be able to connect to Philips monitoring system (PIC iX, Rev C.02) currently in place in the Wichita VA Medical Center. Due to these specific requirements, like items will not be accepted.

Item Product Model

Product Description Quantity

Philips IntelliVue MX-40

1.4 Ghz Smart Hopping

Telemetry Pack

MX-40 MX-40 1.4 GHz Smart Hopping, C01 Enhanced Arrhythmia, M02 Impedance Respiration, S02 ECG + Fast SpO2 Enabled

Salient Characteristics/Requirements

• 2.8" color, touch sensitive display.

• Smart, multi-measurement cable systems are available for use with reusable and single-patient use supplies.

• FAST or Masimo SET SpO2 (continuous, automatic or manual measurement).

• Standard, EASI or Hexad ECG lead system selection.

• Impedance-based Respiration measurement

• Alarm generation from Pulse measurement.

• 6-lead with two V-leads for diagnosing multiple cardiac abnormalities, including wide-QRS complex tachycardias and acute myocardial ischemia/infarction.

• Local measurement trend/alarm history, graphical trend, trend upload.

• Local alarming for measurements

• Integrated radio for connection to an Information Center

• Integrated short-range radio.

• Communication with IntelliVue Patient Monitors and Cableless Measurements via short-range radio connection

• Rechargeable lithium-ion battery pack.

3. INSTALLATION AND CLEANUP: Installation not required. Technical support will be provided to VA staff to ensure that MX-40s connect to the current telemetry system.

4. WARRANTY AND MAINTENANCE SERVICE: Minimum of 1 yr warranty. All manufacturers’ warranty with products upon acceptance by the VA Medical Center and will cover the system, all accessories, and all software and shall include all parts and labor. The warranty period shall not begin until after the Wichita VA POC or designee has accepted the products delivery, installation, and functionality.