SOW_Healy_Hangar_Doors.docx
DOCX document 29 KB Posted
- Attached to
- CGC Healy hangar door technical inspection
- Solicitation number
- 70Z08525Q0029069
About this file
This Statement of Work (SOW) details a technical inspection for the CGC Healy's port and starboard hangar doors at USCG Base Kodiak, AK. The objective is to have Original Equipment Manufacturer (OEM) technicians inspect corroded helicopter door components, conduct testing, submit a Corrective Finding Report (CFR), and provide measurements and replacement assembly estimates. The planned period of performance is 15-20 August 2025, with no parts to be provided by the USCG.
The procurement is a sole-source, firm-fixed-price contract intended for Curtiss Wright, with a North American Industry Classification System (NAICS) code of 336611 for Ship Building and Repairing. The United States Coast Guard Surface Forces Logistics Center is conducting the procurement using commercial item procedures, with interested parties able to submit evidence of competitive advantage by 8:00 AM PST on August 11, 2025, to the contracting point of contact, Ms. Oneal. The technical point of contact for the inspection is LTJG Igor Guerrero, who can be reached at (510) 460-8189 or igor.guerrero@uscg.mil.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| NOTICE OF INTENT TO SOLE SOURCE CGC Healy hangar door technical inspection.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PR #: 52000PR250029069
STATEMENT OF WORK
STATEMENT OF WORK (SOW)
FOR
Port and Starboard Hangar Doors – Inspect CGC Healy
Background: The door does not open reliably and is liable to become stuck, preventing ingress and egress of a helicopter due to corrosion on curtain on roller. The curtain might need to be replaced but will withstand all impacts of flight operations in current state. After conducting ice testing, SF noticed more corrosion and damage to the door from vibrations experience during operations.
1.1 OBJECTIVE
The goal is to supply CGC Healy is to supply OEM technicians to mobilize on site and conduct testing of the helo door components that are corroded. Post inspection, a CFR needs to be submitted to document inspection results. Technicians must make all correct measurements and supply Igor Guerrero with an estimate for replacement of new assemblies.
1) Parts: none will be provided by USCG.
2) Planned period of performance (PoP): 15 – 20 August 2025
a. The service of the CGC Healy’s door must occur in between the PoP dates.
Delivery Address: cutter will be at USCG Base Kodiak, AK at the following address
5th St, Kodiak Station, AK 99619
A list of all personnel traveling must be submitted to the contracting officer and Igor Guerrero prior to the PoP dates.
Please contact LTJG Igor Guerrero at (510) 460-8189 or igor.guerrero@uscg with questions regarding this SOW.
LAST UPDATED: 07/18/2024 PAGE 1/6
File details come from the government source that posted it. Updated .