This is a Scope of Work document for FY 2026 facility upgrades at 11 military recruiting stations across central and southern New Jersey.

The contractor must provide all labor, materials, equipment, and supervision to complete work at Army, Navy, Marine, and Air Force recruiting facilities by June 30, 2026, with a 90-day completion deadline from contract award. Work includes carpet tile replacement at the Army Recruiting Company Headquarters in Blackwood; mini-blind installation at the Navy station in Cherry Hill; video intercom entry control systems (Aiphone IXG) with keypads and desk-tenant stations at the Army Medical Recruiting Station in Cherry Hill and Marines station in New Brunswick; exterior perforated window graphics at the Marines station in Deptford; door sweeps at the Air Force station in East Brunswick; CCTV battery backup and 55-inch monitor installation at the Navy station in Mays Landing; electrified pushbar hardware at the Marines station in Mays Landing; Air National Guard wordmark wall graphics and exterior signage at the Mays Landing Air National Guard facility; acoustical ceiling tile replacement and dual roller shade repairs at the Marines station in Marlton; and Marines EGA/wordmark vinyl graphics and exterior window wraps at the Sicklerville Marines station. The contractor must visit each site before bidding, coordinate with Point of Contact Narciso A. Padilla Garcia (917-968-2891), work during normal business hours with authorized military personnel present, remove and dispose of existing materials, secure the work site, clean up upon completion, and obtain final inspection approval before payment release. The document specifies detailed technical requirements for security systems, video surveillance components, window treatments, and signage, with certifications required from manufacturers and system integrators. Payment may not be released until 60 days after work completion and inspection.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FY26 Upgrades to Contracting – New Jersey Page 1 of 39

SCOPE OF WORK

GENERAL DESCRIPTION: The contractor shall provide all labor, material, equipment, and supervision to accomplish this FY 2026 Upgrade Request for the following locations and military services:

(see below) Work must start at time of contract award.

a. Selected Contractor must visit site before submitting their Bid Price.

b. Selected Contractor must complete this job no later than 90 Days at contract award and must start work prior to 30 June 2026.

c. Selected Contractor must complete this job during normal business hours (9am – 5pm) in the presence of an authorized military personnel. Under no circumstances will a contractor be given keys or access codes to the facility.

d. Selected Contractor must remove and dispose (from premises) all existing materials.

e. Selected Contractor will contact Narciso A. Padilla Garcia at 917-968-2891 and provide a work schedule before gaining access to the Installation.

f. Selected Contractor will secure work site before, during and after work job.

g. Selected Contractor must clean up after completing the job.

h. Selected Contractor must have legal and authorized personnel to perform this job. However, no security clearance is required.

i. Selected Contractor must relocate furniture and other items, within the center of the office space, storage room and/or testing room; however, storage and testing room should not be blocked from future access.

Contractors are responsible for moving and replacing all furniture and equipment including the wall artwork back to their original location.

j. Upon request from the Army Corps of Engineers, Owners/Property Manager, the selected contractor must provide insurance bond. (AMOUNT TO BE DETERMINDED BY OWNER, IF REQUIRED OR REQUESTED) in the owner’s name.

k. Selected Contractor will contact Narciso A. Padilla Garcia at 917-968-2891 (the POC) for full inspection after completion. Payments will not be released until the work is fully done and inspected.

l. Selected Contractor must be aware that payment may not be received until 60 days after work is completed and inspected.

Line Item

Central and South New Jersey

Army Recruiting Company Headquarters

390 Woodbury Turnersville Rd, Blackwood, NJ (Gloucester County) NJ

0002 Navy Recruiting Station 818 Haddonfield Avenue, Cherry Hill, NJ (Camden County). NJ

0003 Army Medical Recruiting Station 2201 Route 38 – Suite 710, Cherry Hill, NJ (Camden County). NJ

0004 Marines Recruiting Station

1800 Clements Bridge Rd – Suite C, Deptford, NJ (Gloucester County). NJ

0005 Air Force Recruiting Station 691 Route 18, East Brunswick, NJ (Middlesex County) NJ

0006 Navy Recruiting Station 2274 S Wrangleboro Road -Unit # 405, Mays Landing, NJ (Atlantic County). NJ

0007 Air National Guard 2300 S Wrangleboro Road – Unit # 328, Mays Landing, NJ (Atlantic County NJ 0008 Marines Recruiting

Station 150 Route 73 North, Marlton, NJ (Burlington County) NJ

0009 Marines Recruiting Station 303 George Street – Suite # G, Marines, NJ (Middlesex County) NJ

0010 Army Recruiting Station 609A Berlin-Cross Keys Road, Sicklerville, NJ (Camden County) NJ

0011 Marines Recruiting Station 609A Berlin-Cross Keys Road, Sicklerville, NJ (Camden County) NJ

FY26 Upgrades to Contracting – New Jersey Page 2 of 39

Army Recruiting company HQs at 390 Woodbury-Turnersville Road, Room #112C, Blackwood, NJ

ITEM 0001A: REPLACE CARPET TILES IN ALL INTERIOR OFFICE AREA(S)

1. Flooring:

a. Army request to remove all old carpet tiles in office area(s) and install new carpet tiles in all office area(s).

Contractor will be responsible for removing and replacing all furniture as required.

b. Base Cove (for VCT & Carpet only): Johnsonite/Tarkett (https://distributor.tarkett.com), Rubber; Color: #40, Black, 4” H.

c. Carpet Schedule (office, test room and related areas): Carpet tiles with base cove shall be installed throughout the entire space except storage rooms, restrooms, common area lobbies, corridors, and exit areas. All carpet must be installed smoothly and evenly in accordance with manufacturer’s instructions and with the approved low Volatile Organic Compounds (VOC’s) release adhesive. One (1)extra box of carpet tiles (for the Army at this location) shall be left in the security closet for future use.

ARMY CARPET SCHEDULE

Manufacturer / Style: U.S. Army Recruiting Standard: # 802E5 Color (Name, Number): Duty, BB90D Product: Carpet Tile Installation Method: Quarter Turn Installation Adhesive: "LokDots" Adhesive System

Navy Recruiting Station located at 818 Haddonfield Avenue, Cherry Hill, NJ (Camden County).

ITEM 0002A: INSTALL ONE (1) MINI-BLIND ON NAVY’S INTERIOR FRONT ENTRANCE GLASS DOOR

AND INTERIOR WINDOW GLASS

1. Mini-Blinds: NOT TO BE INSTALLED ON ANY EXTERIOR WINDOWS OR DOORS.

a. Install Mini-Blinds (interior front entrance door only): All interior front entrance door shall be equipped with mini-blinds having non-corroding mechanisms and synthetic tapes. Each window shall have its own individual mini-blind. Mini-blinds shall be Hunter Douglas Riviera Commercial Aluminum Horizontal Blinds (cordless), Color: Brushed Aluminum # G8-034, with 1” wide aluminum horizontal slat with beveled steel profile or approved equal. Note: To prevent swaying, mini blinds that are installed on interior doors must be secured at the bottom of the door with metal clips.

Army Medical Recruiting Station located at 2201 Route 38 – Suite 710, Cherry Hill, NJ (Camden County).

ITEM 0003A: INSTALL TWO (2) VIDEO INTERCOM ENTRY CONTROL SYSTEM – ONE (1) IXG-2C7 DESK TENANT STATION, ONE (1) IXG-DM7-HIDA AIPHONE IXG SYSTEM DOOR ENTRANCE STATION (WITH MOUNTING BRACKET), ONE (1) AIPHONE – SURFACE MOUNT BOX, INCLUDES RAIN HOOD AND ONE

(1) DK-26 SECURITRON – KEYPAD WITH ALL REQUIRED COMPONENTS

1. Install brand-new AiPhone IXG System and new Keypad.

VIDEO INTERCOM ENTRY CONTROL (EC) SYSTEM COMPONENTS TABLE

Application: Model / Skew #’s: Description: Qt y: Notes:

Primary Entrance and/or Secondary Egress Doors

IXG-DM7-HIDA

Aiphone - IXG System Door-Entrance Station (with mounting bracket)

E a

� See Note 1, 2, 3, 4, 5.

https://distributor.tarkett.com/

FY26 Upgrades to Contracting – New Jersey Page 3 of 39

Door-Entrance Station Mount SBX-IXGDM7 Aiphone - Surface Mount

Box, Includes Rain Hood

E a

Keypad DK-26 SS Securitron - Keypad with CPU Board/Controller

E a

� Optional Rear Egress Only See Note 4, 11

Each Military Service Space IXG-2C7 Aiphone - Desk-Tenant

Station

E a

� See Note 1, 6

Each Military Service Space MCW-S/B Aiphone - Desk-Tenant

Station – Stand

E a

Per Desk-Tenant Station

Security Board

IXG-MAA Aiphone - Network Door Release Relay Adaptor 1

� Selective door release (allows Military Services to release specific doors)

IXG-MK Aiphone - Guard Station (includes flush mount kit) 1 � See Note 12

FPO250-

C8D8E2

LSP - Power Supply (hardwired on security board)

1 � 8 Door / 8 Lock, 20A, 12VDC

Primary Entrance Doors DPS-M-GY

Securitron - Door Position Switch (Magnetic)

E a

� Use DPS-W-GY for Wood Doors. Only required for shared / common area egress doors.

Security Board (in Security Cabinet)

GS752TPP-

300NAS

NETGEAR – 48 Port Primary PoE+ Switch

E a

� 48 Port (expandable with another 24 or 48 port switch)

Security Board (in Security Cabinet)

GS524UP-

100NAS

NETGEAR – 24 Port Optional / Secondary PoE++ Switch

E a

� 24 Port PoE++ Switch (See Note 5)

VIDEO INTERCOM ENTRY CONTROL (EC) NOTES:

1) REQUIRED FOR CONTRACTORS:

a. Contractor MUST complete questionnaire form for Aiphone custom program configuration file, which will be provided to the contractor for each office via email.

b. Programming design questionnaire forms & information to be completed at:

https://www.aiphone.com/support/technical-support/aiphone-programming-questionnaire

2) See https://www.aiphone.com/products/ixg-series for IXG specifics and recruitingcenters@aiphone.com for installation details / questions at recruiting centers.

3) Certified Integrators / Installers (warranty):

a. Aiphone - https://www.aiphone.com/kbtopic/ix-series-integrations-hanwha

b. Hanwha Vision STEP Partner - https://hanwhavisionamerica.com/partner-portal/

c. ASSA ABLOY (Rockwood, Securitron, Accentra, AdamsRite, and Pemko components) -https://www.assaabloydss.com/en/support/installation-and-service-partners/certified-integrators

4) Door release time range: Default of 5-10 seconds for all electrified doors / key pads (IXG, DK-26).

5) Door-entrance station cameras to be connected to the CCTV system and shown on service specific open area television only. These cameras and desk-tenant stations require a PoE+ Switch connection. A license is needed to record door entrance station camera. Either recordability or viewability with be an option but not both. If more than 48 ports (or PoE++ ports) are required, add on the optional / secondary PoE+ Switch.

6) Door-entrance station mounting: If possible, mount door-entrance station on the side of the mullion flush to the exterior window. Purpose would be to try to limit the ability for the entrance station from being pulled off of the storefront.

7) Desk-tenant stations to be installed in each Military Service facility (minimum of 2, maximum of

8) for each Military Service recruiter identified in paragraph A.4. See Air Force Attachment “4a” for their desk-station requirements. Optional wall mounted desk-tenant stations should be placed free and clear of all Military Service accent walls (as identified on approved floor plan / AE drawings).

Wall Outlet (yellow data port jack) to desk-tenant station shall include an eight (8) foot yellow straight-blockedhttps://Blockedwww.aiphone.com/support/technical-support/aiphone-programming-questionnaire https://www.aiphone.com/products/ixg-series mailto:recruitingcenters@aiphone.com https://hanwhavisionamerica.com/partner-portal/

FY26 Upgrades to Contracting – New Jersey Page 4 of 39 through CAT 6 patch wire. In rare cases (as directed by a COE representative or on the approved floor plan / AE drawings) a wall mount for desk-tenant stations may be necessary (wall mount model = IXG-

FMK-2C7).

8) See paragraph G.7 for Door Hardware Schedule & release components.

9) All stranded low voltage wire (exit device, keypad, and door position switch) will be 18 AWG stranded wire with label / tag at each end for easy identification and troubleshooting. See ENCLOSURE #6a, 6b, 6c, and 6d for EC example components, wiring and layout diagrams.

10) See paragraph K. for PoE+ Switch & LSP Power supply requirements (hardwired on security board).

11) See communications paragraph E and ENCLOSURE #1a, 1b, 1c and 1d for locations and colors of data port jacks and CAT 6 wires.

12) No Public Access Secondary Doors: A secondary egress door that only Recruiting personnel use to enter the station. Typically, the public or potential recruits do not access thru this door. The “No public access doors” only requires the Securitron DK-26 Keypad with controller (vs the Aiphone door-entrance station). If the secondary egress is just an emergency only egress where no parties typically than neither the DK-26 or Aiphone door-station will be needed.

13) Door position switches to activate shared egress door(s) chime(s). Primary shared egress doors shall have a single-tone (e.g. - “ding”), and secondary shared egress door(s) shall have two-tones (e.g. - “ding-dong”).

FY26 Upgrades to Contracting – New Jersey Page 5 of 39

ENCLOSURE #6a, 6b, 6c and 6d

GENERAL STANDARD (GS)

Video Intercom Entry Control (EC) - IXG System Wiring Diagrams & Example Setup

FY26 Upgrades to Contracting – New Jersey Page 6 of 39

Security Hardware / Application Requirements (EC & CCTV/NVR Systems): Contractor will advise the COE Representative on any unique site / office requirement(s) which will require any modifications to these specified security components.

FY26 Upgrades to Contracting – New Jersey Page 7 of 39

a. Off network / offline Hardware.

b. Certified Integrators / Installers (warranty):

1. Aiphone - https://www.aiphone.com/kbtopic/ix-series-integrations-hanwha

2. Hanwha Vision STEP Partner - https://hanwhavisionamerica.com/partner-portal/

3. ASSA ABLOY (Rockwood, Securitron, Accentra, AdamsRite, and Pemko components) -https://www.assaabloydss.com/en/support/installation-and-service-partners/certified-integrators

c. EC and CCTV / NVR systems to be installed at the same time as they are integrated. Aiphone: IXG support tool file and IXG site specific configuration file to be loaded on the NVR (operating system drive).

d. NVR Computer Bios / Auto Start: Contractor to set / confirm NVR system BIOS settings are set to reboot automatically on power loss with MS Windows Auto Login (NO login password).

Bios instructions are as follows:

1. Power On the NVR and press "DEL" or "F1" or "F2" or "F10" to enter BIOS (CMOS) setup utility (the way to enter into BIOS Settings depends on the computer board manufacturer).

2. Inside BIOS menu, look under the following menus to find for a setting named “Restore on AC/Power Loss” or “AC Power Recovery” or "After Power Loss", “Advanced” or “ACPI” or "Power Management Setup".

3. Note: The “Restore on AC/Power Loss” setting can be found under different places inside BIOS setup according to computer manufacturer.

4. Set the “Restore on AC/Power Loss” setting to “Power On”.

5. Save and exit from BIOS settings.

e. Static IP Address Schedule: Manually set / confirmed by contractor.

1. Network PoE+ Switch(s) = 192.168.1.1-25 range.

2. Aiphone = 192.168.1.100-199 range – pre-set by Aiphone programming file.

3. CCTV / NVR = 192.168.1.200-255 range.

f. User IDs, Passwords and Door Access Codes: Contractor to coordinate with the COE Representative for setting / integrating user IDs, passwords, and temporary door access codes, including controlled distribution.

Contractor to ONLY assist the Military Services facility managers / ATO’s with programming the final door access codes.

1. Both the Aiphone IXG and Hanwha CCTV/NVR systems each require two (2) user / login levels each:

i.Aiphone IXG Support Tool:

• Administrator for installer (Recruiters will not have access).

• Property Manager for facility managers / ATOs (Recruiters will not have access).

ii.Hanwha / Wisenet Device Manager (CCTV): With these predefined user roles.

• Owner for installer / facility managers / ATOs (Recruiters will not have access).

• Viewer for onsite Recruiters / personnel.

iii.No MS Windows login passwords. Windows Auto Login only.

2. System User IDs & Passwords (EC, CCTV/NVR/Decoder, PoE+ Switch): User IDs / passwords shall be reset from defaults and set / integrated to match / align with each other. Admin and Owner user login level(s) & passwords to be set / integrated to match / align with each login level for all systems. Local Personnel / Recruiters will only have access to the Wisenet “Viewer” user.

3. Door Access Codes with Controlled Distribution: Contractor to program two (2) temporary and unique access codes for each Military Service present. The EC door-entrance station(s) (e.g. – A4611), and optional Securitron DK-26 individual keypad(s) codes to match #’s (e.g. – 4611) if both units are present.

Two (2) separate and unique access codes are necessary for each Military Service.

g. Camera & Door-Entrance Station Tools (Torx Tool): To be stored in a clear sleeve inside the Security cabinet at the Security Board.

h. System Documentation for CCTV/NVR Setup & License Tracking by Contractor (activated licenses for all cameras, EC door-entrance station cameras, etc.):

1. One copy of the system(s) hardware documentation / manuals / login details, and camera licenses are to be stored in a clear sleeve (along with the door-entrance station / camera tool (Torx tool) inside the Security cabinet at the Security Board.

2. Save the following files on the NVR (operating system drive):

i.Screen shots of all license keys and #’s (email second copy to the COE representative).

ii.Create Wisenet project file with current date.

iii.Run Wisenet camera / encoder report “ALL” (email second copy to the COE representative).

iv.Create camera config backup file.

i. Printed Exporting Video Instructions: Provide “how to” instructions on exporting video footage from NVR, via USB extension wire located next to keyboard. Printed instructions to be placed in clear plastic sleeve and mounted above NVR monitor on Security Board.

j. System Training:

FY26 Upgrades to Contracting – New Jersey Page 8 of 39

1. A Training event will be scheduled and coordinated with the COE Representative for all Military Services / personnel (see paragraph A.4. for recruiter numbers). Installer(s) will submit to the COE a legible, dated roster with the trainer’s contact information, each Trainee’s name/rank, along with systems covered.

2. Minimum of a 1-hour training session MUST be provided as part of the installation by the contractor to ALL Military Services where the system(s) is installed.

3. On-site training to use “temporary” door access codes with Military Service personnel. Temporary access codes to be deleted / reprogrammed by Service Facility Managers / ATO’s after training is accomplished.

4. The training will cover minimum items:

i.EC System:

• Individual Service access codes with controlled distribution to the Facility Manager / ATO.

• System Features and operation of door-entrance station(s), keypads, desk-tenant stations.

• RJ45 port and wire colors.

• How to disconnect and reconnect desk-tenant stations.

• Basic troubleshooting options / methods.

• Ensure door release time range is set to 5-10 seconds for electrified doors / keypads.

ii.CCTV/NVR/Decoder with monitor displays:

• Review camera placements and system features / settings.

• Adjust each camera and Military Branch display for optimal egress / camera views.

• What to do if the CCTV system shuts down, or display monitors stop displaying.

• Demonstrate automatic restart / reboot NVR and display monitors in each office.

• Discuss and provide location of printed “how to” instructions on exporting video footage from NVR.

iii.Facility Managers / ATO’s: When present, detailed training for required (names / emails previously given by COE representative):

• Individual system software (Aiphone, Wisenet) instructional demo for logging in.

• Demonstrate features and operation on each system present.

• How to add/remove recruiter(s) door access code(s) on Aiphone IXG Support Tool and DK-26 control board.

• How to retrieve door entrance history / access control data from Aiphone IXG Support Tool.

• How to disconnect/reconnect desk-tenant stations.

• Demonstrate automatic reboot / restart on EACH System, basic trouble shooting options.

• How to search / retrieve / export data video from NVR.

• What to do if the CCTV system shuts down, or display monitors stop displaying.

Marines Recruiting Station at 1800 Clements Bridge Rd – Suite C, Deptford, NJ

ITEM 0004A: INSTALL EXTERIOR JOINT PERFORATED WINDOW GRAPHICS (ONLY ON EXTERIOR

STOREFRONT ENTRANCE

1. Exterior Signs Graphics General: Install Exterior Joint Perforated Window Wrap Graphics (Only on exterior main storefront entrance)

a. Perforated Window Wraps: The application of perforated window wraps is dependent upon the type of facility, along with other requirements. COE representative / Military Service(s) shall have control over what graphic is applied, what position the graphic will be placed and on which windows. Lessor / contractor will coordinate with the COE representative. ALL perforated window wraps to incorporate into the overall graphic a “Weapons Prohibited” graphic (8.5” W x 11” H) centered vertically on the door directly next to the handle (see below example and Box.com for the graphic file).

FY26 Upgrades to Contracting – New Jersey Page 9 of 39

Example Only – COE to Provide Link for Specific Graphics.

b. Collocated with a Shared Entrance Door (JRFC Graphic): When multiple Military Services are present and they share the same entrance door, a “JRFC Graphic” will be installed. Perforated window wrap installations shall have 100% coverage of all exterior glass, including common area windows (if applicable). If Military Service “exclusive” windows on the sides or rear of the premises (not front windows) are present, individual Military Service graphics can be applied to those windows (coordinate with the COE Representative). The JRFC Graphic image shown below is provided for reference purposes ONLY. This image will be included in a PDF “Style Guide” that the contractor MUST download with detailed instructions. The image needs to be put together with specified materials and look as close to the below image as possible. In the Style Guide, the black lines represent window / door mullions. ALL perforated window wraps to incorporate into the overall graphic a “Weapons Prohibited” graphic (8.5” W x 11” H) centered vertically on the door directly next to the handle (see example and Box.com for the graphic file). The COE representative will provide a link and folder name for the contractor to download ALL appropriate files necessary (36 in total) to create / install the JRFC Graphic:

The Lessor will provide all graphics examples and mockup elevations for COE approval, and when chosen, provide final proofs and storefront elevation renderings of the approved graphics.

c. The approved graphic(s) shall meet the following standard(s) or equivalent on all storefront window wrap applications (including all manufacturer installation requirements MUST be followed, especially for temperatures, for the installation of all perforated exterior graphics):

a.3M, 8170 – P40 (40% perforated), 4-mil, opaque, cast vinyl film with a high gloss finish.

b.Window graphic film will have a visual obscurity density of 60 / 40.

c.Apply 3M Scotchcal Optically Clear Gloss Overlaminate (8518) and shall be laminated prior to installation.

d.Apply 3M edge sealer tape 8914 at time of installation to all edges of the perforated film to prevent pealing.

e.The Lessor will coordinate with the Army Corps of Engineers (COE) representative regarding the correct graphic. The following are the types of graphics that might be installed at a location (as indicated in #1 and #2 above), and in rare cases both could be installed.

f.Military Service Individual Graphics (Stand-alone OR Collocated with separate entrance doors).

g.JRFC Graphic (Collocated with shared entrance door for all Military Services).

Note: Only the COE representative will make the final decision on the approved graphics.

FY26 Upgrades to Contracting – New Jersey Page 10 of 39

Air Force Recruiting Station at 691 Route 18, East Brunswick, NJ

ITEM 0005A: INSTALL DOOR SWEEPS; NOT ANTI-PRY PLATE AT THE TOP AND BOTTOM OF EXTERIO

SECOND DOOR

1. The Exterior second door needs door sweeps/weather stripping install at the top and bottom to close the gap and prevent things being put into office.

Navy Recruiting Station located at 2274 S. Wrangleboro Road, Mays Landing, NJ AKA: 2300 (405) Wrangleboro, Road, Mays Landing, NJ

ITEM 0006A: INSTALL BATTERY BACKUP FOR CLOSED CIRCUIT TELEVISION (CCTV) / DIGITAL VIDEO RECORDER (DVR) AND OR NETWORK VIDEO RECORDER (NVR); INSTALL CCTV 55” TV MONITOR IN

RECRUITER’S OFFICE AND RESET ACCESS CODES FOR CCTV/NVR

1. The Navy is requesting the installation of a brand-new BATTERY BACKUP FOR CLOSED CIRCUIT TELEVISION

(CCTV) / DIGITAL VIDEO RECORDER (DVR) AND OR NETWORK VIDEO RECORDER (NVR); INSTALL CCTV 55”

TV MONITOR IN RECRUITER’S OFFICE, RESET ACCESS CODES AND ISSUE NEW USERNAME AND

PASSOWRDS FOR THE CCTV/NVR SECURITY SYSTEM TO ALL ASSIGNED RECRUITING PERSONNEL.

2. Military Service Space: CCTV Display Monitors with Decoder:

a. Install One (1) Samsung DU8000 55” UHD LED Monitor: One (1) plus CCTV Display Monitors to be installed in the Navy Recruiting Office open office area as marked on the floor plan for dedicated CCTV viewing, via the SPD-152 PoE decoder. Centered in open office area to allow maximum visibility by recruiters, minimize glare or bright sunlight (which reduces visibility). NOT to be mounted near exterior windows.

b. User IDs, Passwords and Door Access Codes: Contractor to coordinate with the COE Representative for setting / integrating user IDs, passwords, and temporary door access codes, including controlled distribution. Contractor to ONLY assist the Military Services facility managers / ATO’s with programming the final door access codes.

1. The CCTV/NVR system require two (2) user / login levels each:

i.Hanwha / Wisenet Device Manager (CCTV): With these predefined user roles.

1. Viewer for onsite Recruiters / personnel.

ii.No MS Windows login passwords. Windows Auto Login only.

2. System User IDs & Passwords (EC, CCTV/NVR/Decoder, PoE+ Switch): User IDs / passwords shall be reset from defaults and set / integrated to match / align with each other. Admin and Owner user login level(s) & passwords to be set / integrated to match / align with each login level for all systems. Local Personnel / Recruiters will only have access to the Wisenet “Viewer” user.

FY26 Upgrades to Contracting – New Jersey Page 11 of 39

ITEM 0006B: INSTALL ADAMSRITE 8000 SERIES - ELECTRIFIED PUSHBAR, NEW LOCKSET WITH MOST UP-TO-

DATE HARDWARE ON EXTERIOR SECONDARY EGRESS DOOR

1. Install a brand-new Adamsrite 8000 series – electrified push-bar and new lockset with the most up to date hardware as listed below:

Marines Recruiting Station located at 2274 S. Wrangleboro Road, Mays Landing, NJ AKA: 2300 (405 Consumer Square) Wrangleboro, Road, Mays Landing, NJ

ITEM 0006C: INSTALL EXTERIOR JOINT PERFORATED WINDOW GRAPHICS (ONLY ON EXTERIOR

STOREFRONT ENTRANCE

1. Exterior Signs Graphics General: Install Exterior Joint Perforated Window Wrap Graphics (Only on exterior main storefront entrance)

a. Perforated Window Wraps: The application of perforated window wraps is dependent upon the type of facility, along with other requirements. COE representative / Military Service(s) shall have control over what graphic is applied, what position the graphic will be placed and on which windows. Lessor / contractor will coordinate with the COE representative. ALL perforated window wraps to incorporate into the overall graphic a “Weapons Prohibited” graphic (8.5” W x 11” H) centered vertically on the door directly next to the handle (see below example and Box.com for the graphic file).

Application: Model / Skew #’s: Description: Size: Finish: Qt y:

Set Codes: Notes:

Exterior Secondary Egress Door

8701EL36-24 Adams Rite - Rim Exit Device

2-5/8” x 36”

Satin Aluminum 1

E3

Electrified - 3701-36 for fire rated doors

A620-626 Yale – Cylinder Housing & Interchangeable Core N/A Satin

Chrome 1

MS4043-00-

130 Adams Rite - Guard Ring N/A Clear

Anodized 1

4612-1 Adams Rite - Power Transfer N/A Chrome 1 �Electrified

BF158-630 Rockwood - Door Pull 1” x 12” Satin SS 1 Match Existing building color

3531-689 Yale - Automatic Door Closer

2-1/8” x 12” Aluminum 1

BLP-210

(outswing)

DON-JO - Security Latch Guard (Anti-Pry Plate)

10” x 3.25” (outswin g)

Match Existing 1

Conform to existing door configuration (e.g., offset, door handle, etc.)

FY26 Upgrades to Contracting – New Jersey Page 12 of 39

Example Only – COE to Provide Link for Specific Graphics.

b. Collocated with a Shared Entrance Door (JRFC Graphic): When multiple Military Services are present and they share the same entrance door, a “JRFC Graphic” will be installed. Perforated window wrap installations shall have 100% coverage of all exterior glass, including common area windows (if applicable). If Military Service “exclusive” windows on the sides or rear of the premises (not front windows) are present, individual Military Service graphics can be applied to those windows (coordinate with the COE Representative). The JRFC Graphic image shown below is provided for reference purposes ONLY. This image will be included in a PDF “Style Guide” that the contractor MUST download with detailed instructions. The image needs to be put together with specified materials and look as close to the below image as possible. In the Style Guide, the black lines represent window / door mullions. ALL perforated window wraps to incorporate into the overall graphic a “Weapons Prohibited” graphic (8.5” W x 11” H) centered vertically on the door directly next to the handle (see example and Box.com for the graphic file). The COE representative will provide a link and folder name for the contractor to download ALL appropriate files necessary (36 in total) to create / install the JRFC Graphic:

The Lessor will provide all graphics examples and mockup elevations for COE approval, and when chosen, provide final proofs and storefront elevation renderings of the approved graphics.

c. The approved graphic(s) shall meet the following standard(s) or equivalent on all storefront window wrap applications (including all manufacturer installation requirements MUST be followed, especially for temperatures, for the installation of all perforated exterior graphics):

a.3M, 8170 – P40 (40% perforated), 4-mil, opaque, cast vinyl film with a high gloss finish.

b.Window graphic film will have a visual obscurity density of 60 / 40.

c.Apply 3M Scotchcal Optically Clear Gloss Overlaminate (8518) and shall be laminated prior to installation.

d.Apply 3M edge sealer tape 8914 at time of installation to all edges of the perforated film to prevent pealing.

e.The Lessor will coordinate with the Army Corps of Engineers (COE) representative regarding the correct graphic. The following are the types of graphics that might be installed at a location (as indicated in #1 and #2 above), and in rare cases both could be installed.

f.Military Service Individual Graphics (Stand-alone OR Collocated with separate entrance doors).

g.JRFC Graphic (Collocated with shared entrance door for all Military Services).

Note: Only the COE representative will make the final decision on the approved graphics.

FY26 Upgrades to Contracting – New Jersey Page 13 of 39

Air National Guard Recruiting Station located at 2274 S. Wrangleboro Road, Mays Landing, NJ AKA: 2300 (328 Consumer Square) Wrangleboro, Road, Mays Landing, NJ

ITEM 0007A: INSTALL BRAND NEW AIR NATIONAL GUARD WORDMARK WALL GRAPHIC

1. Install brand-new Air National Guard “Wordmark” wall graphic.

a. Interior Signage and Wall Graphics:

The Air National Guard's "Wordmark" wall graphic. The blue accent wall should be as designated on the approved floor plan / AE drawing.

The Air National Guard Wordmark wall graphic is always placed on a painted blue wall. It is surface-applied, self-adhesive vinyl, color to match PMS 11-4001 TCX, Brilliant White, matte finish. Approved ANG Wordmark printed vinyl:

3M 180CV3-10 opaque white vinyl surface ink jet print to match PMS 11-4001 TCX, Brilliant White, and adjust as needed for accurate match. Surface laminated with 3M 8520 UV resistant matte clear overlay. Alternate manufacturers (e.g., Arlon, Avery, GSP, OraCal, LG or other) sign vinyl materials equivalent to 3M 180 Series, rated for high bond wall application, and the minimum use 5-year warranty may be provided based on contractor recommendation.

Wordmark is to be scaled as large as possible with the top of the Wordmark high on the wall, but at least 2’-0” from the ceiling. Generally, the bottom is at least 4’-0” AFF.

Note 1: The painted blue wall requires a minimum of four days (96 hours) for complete curing and drying time before application of vinyl wall graphics can occur. Paint drying time will need to be extended in cool or cold climates. Graphics contractor is to be advised of this requirement.

Note 2: Wall mounted fixtures such as thermostats, wall switches, emergency lighting, and light sensors, etc., should be placed free and clear of all Military Service accents walls.

Note 3: If Wordmark is installed on a painted white wall, the Wordmark should have blue wings and text, and no background (wings and text are individual pieces of the vinyl logo). It is surface-applied, self-adhesive vinyl, color to match PMS 287, matte finish, a darker blue non-metallic color. Approved ANG Wordmark printed vinyl: 3M 180CV3-10 opaque white vinyl surface ink jet print to match PMS 287 (a darker blue non-metallic color) adjust as needed for accurate match to PMS 287.

ANG Wordmark Interior Wall Graphic Options (blue color represents the blue accent wall) – Stacked (Preferred) & Linear / Horizontal (Alternate) Versions:

AIR NATIONAL GUARD – SIGNAGE & GRAPHIC COLOR DESIGNATIONS

RGB

Example:

0, 82, 143

RGB

Example:

0, 0, 0

RGB

Example:

143,143,140

RGB

Example:

166, 166, 168

RGB Example:

237, 241, 255

PMS

Colors

PMS

PMS

Black

PMS

Silver 877c

PMS

Cool Grey 7

PMS

11-4001 TCX

FY26 Upgrades to Contracting – New Jersey Page 14 of 39

Brilliant White

CMYK

Colors

C 100 M 69 Y 01 K 11

C 0 M 0 Y 0 K 100

C 38 M 27 Y 26 K 9

C 0 M 0 Y 0 K 50

C 7 M 5 Y 0 K 0

RGB

Colors

RGB

0, 82, 143

RGB

0, 0, 0

RGB

143, 143, RGB

166, 166, RGB

237, 241, 255

HEX

Colors

HEX

00528f

HEX

000000

HEX

8c9091

HEX

a6a6a8

HEX

EDF1FF

FY26 Upgrades to Contracting – New Jersey Page 15 of 39

ITEM 0007B: REMOVE EXISTING EXTERIOR SIGNAGE AND INSTALL BRAND-NEW EXTERIOR SIGNAGE PER

FY26 CONSTRUCTION SPECS PROVIDED

1. Remove existing Exterior Signage and install a bran-new Exterior Signage per FY26 Construction Specs.

Signage:

a. Exterior Signage: Lessor to confirm approved sign for use. Upon approval, the COE will provide an EPS file to the Lessor with appropriate sign design standards. Box Signage (Stand-Alone Location) – Stacked (Preferred) & Linear / Horizontal (Alternate) Versions:

b. Channel Letter LED (Stand-Alone Location) – Stacked (Preferred) & Linear / Horizontal (Alternate) Versions.

Channel letter returns and raceway color to match building façade:

AIR NATIONAL GUARD – SIGNAGE & GRAPHIC COLOR DESIGNATIONS

RGB

Example:

0, 82, 143

RGB

Example:

0, 0, 0

RGB

Example:

143,143,140

RGB

Example:

166, 166, 168

RGB Example:

237, 241, 255

PMS

Colors

PMS

PMS

Black

PMS

Silver 877c

PMS

Cool Grey 7

PMS

11-4001 TCX

Brilliant White

CMYK

Colors

C 100 M 69 Y 01 K 11

C 0 M 0 Y 0 K 100

C 38 M 27 Y 26 K 9

C 0 M 0 Y 0 K 50

C 7 M 5 Y 0 K 0

RGB

Colors

RGB

0, 82, 143

RGB

0, 0, 0

RGB

143, 143, RGB

166, 166, RGB

237, 241, 255

HEX

Colors

HEX

00528f

HEX

000000

HEX

8c9091

HEX

a6a6a8

HEX

EDF1FF

FY26 Upgrades to Contracting – New Jersey Page 16 of 39

Marines Recruiting Station located at 150 Route 73 North, Marlton, NJ

ITEM 0008A: SPOT REPLACE FIVE (5) ACOUSTICAL CEILING TILES

1. Replace Five (5) damaged and or stained acoustical ceiling tiles.

ITEM 0008B: REPAIR FOUR (4) DUAL ROLLER SHADES THAT ARE NOT WORKING PROPERLY

1. Roller Shades: ALL exterior windows shall have roller shades installed. WHEN INSTALLED, SHADES

SHALL NOT ALLOW

FOR ANY VISUAL GAPS.

a.Roller Shades (windows only): The Lessor will coordinate with the COE as to whether single roller shades are required. Single or Dual shades to be Hunter Douglas Architectural, Contract Roller Shade: Model #RB500 or equivalent. Fascia & End Cap finishes to be “anodized aluminum”. These shades will not require military logos.

To ensure a uniform appearance, all window shades will be motorized, with an appropriate electric wall keypad / switch control(s) for multiple shades, as identified on the floor plan / AE drawing (installed at the front and rear of each Military Service facility). Each switch / keypad to be labeled.

NOTE: BATTERY OPERATED KEYPADS ARE NOT ALLOWED. Roller Shade couplers will be used to minimize the number of motors and electrical drop(s) required (up to 300” in length and/or 6 roller shades). All electrical power to be hardwired within conduit inside walls. Shades shall NOT be installed inside the window frame (in order to connect multiple roller shades together with a single motor). Motor to be, Sonesse Ultra model # 50 RA with a sound level equivalent to an office conversation. Installation shall be as per manufacturer’s written instructions ~ to include all necessary blocking and structural supports. Shades to include the required number of Individual Group Control (IGC) 4N1 motor controls (mounted above window, within ceiling, near front door when possible) with a HARDWIRED DecoFlex dry contact keypad / switch to be located at rear of space, by storage room door (as identified on floor plan / AE drawing). Shades will have a lifetime warranty and pass the NFPA 701 Small Scale test. If window(s) cannot be equipped with roller shades, either because of their unique shape and/or the inability to install the shade correctly, then only with expressed prior approval of the COE, a fixed panel shade shall be applied in accordance with fixed panel specifications below. If already installed, existing glass block requires no window covering. For wiring diagrams, see ENCLOSURES #4.

b.Dual Roller Shades (windows only): Dual Roller shades will be installed when an exterior perforated window wrap IS NOT or WILL NOT be applied to the exterior windows. Shades to have both ‘Sheer’ and ‘Privacy’ fabrics. The ‘Sheer Shade’ shall be of a fabric equal to Hunter Douglas E Screen 3% White / White to be closest to the window.

The ‘Privacy Shade’ shall be fabric equal to Hunter Douglas SheerWeave 7100 P12 Oyster. If the 7100 fabric is not available, the alternate fabric to be SheerWeave 7400 Cotton. Note: If a dual shade application is required, it may be necessary to install two individual shades if existing window conditions do not allow enough room to accommodate a dual shade bracket.

FY26 Upgrades to Contracting – New Jersey Page 17 of 39

ENCLOSURE #4a, 4b, 4c, 4d and 4e

Dual Roller Shade Wiring Diagrams

FY26 Upgrades to Contracting – New Jersey Page 18 of 39

FY26 Upgrades to Contracting – New Jersey Page 19 of 39

303 George Street – Suite # G, New Brunswick, NJ (Middlesex County)

ITEM 0009A: INSTALL TWO (2) VIDEO INTERCOM ENTRY CONTROL SYSTEM – ONE (1) IXG-2C7 DESK TENANT STATION, ONE (1) IXG-DM7-HIDA AIPHONE IXG SYSTEM DOOR ENTRANCE STATION (WITH MOUNTING BRACKET), ONE (1) AIPHONE – SURFACE MOUNT BOX, INCLUDES RAIN HOOD AND ONE

(1) DK-26 SECURITRON – KEYPAD WITH ALL REQUIERD COMPONENTS

1. Install brand-new AiPhone IXG System and new Keypad.

VIDEO INTERCOM ENTRY CONTROL (EC) SYSTEM COMPONENTS TABLE

Application: Model / Skew #’s: Description: Qt y: Notes:

Primary Entrance and/or Secondary Egress Doors

IXG-DM7-HIDA

Aiphone - IXG System Door-Entrance Station (with mounting bracket)

E a � See Note 1, 2, 3, 4, 5.

Door-Entrance Station Mount SBX-IXGDM7 Aiphone - Surface Mount

Box, Includes Rain Hood E a

Keypad DK-26 SS Securitron - Keypad with CPU Board/Controller

E a

� Optional Rear Egress Only See Note 4, 11

Each Military Service Space IXG-2C7 Aiphone - Desk-Tenant

Station 2+ � See Note 1, 6

Each Military Service Space MCW-S/B Aiphone - Desk-Tenant

Station – Stand E a Per Desk-Tenant Station

Security Board

IXG-MAA Aiphone - Network Door Release Relay Adaptor 1

� Selective door release (allows Military Services to release specific doors)

IXG-MK Aiphone - Guard Station (includes flush mount kit) 1 � See Note 12

FPO250-

C8D8E2

LSP - Power Supply (hardwired on security board)

1 � 8 Door / 8 Lock, 20A, 12VDC

Primary Entrance Doors DPS-M-GY

Securitron - Door Position Switch (Magnetic)

E a

� Use DPS-W-GY for Wood Doors. Only required for shared / common area egress doors.

Security Board (in Security Cabinet)

GS752TPP-

300NAS

NETGEAR – 48 Port Primary PoE+ Switch

E a

� 48 Port (expandable with another 24 or 48 port switch)

Security Board (in Security Cabinet)

GS524UP-

100NAS

NETGEAR – 24 Port Optional / Secondary PoE++ Switch

E a

� 24 Port PoE++ Switch (See Note 5)

VIDEO INTERCOM ENTRY CONTROL (EC) NOTES:

14) REQUIRED FOR CONTRACTORS:

a. Contractor MUST complete questionnaire form for Aiphone custom program configuration file, which will be provided to the contractor for each office via email.

b. Programming design questionnaire forms & information to be completed at:

https://www.aiphone.com/support/technical-support/aiphone-programming-questionnaire

15) See https://www.aiphone.com/products/ixg-series for IXG specifics and recruitingcenters@aiphone.com for installation details / questions at recruiting centers.

16) Certified Integrators / Installers (warranty):

a. Aiphone - https://www.aiphone.com/kbtopic/ix-series-integrations-hanwha

b. Hanwha Vision STEP Partner - https://hanwhavisionamerica.com/partner-portal/

c. ASSA ABLOY (Rockwood, Securitron, Accentra, AdamsRite, and Pemko components) -https://www.assaabloydss.com/en/support/installation-and-service-partners/certified-integrators

17) Door release time range: Default of 5-10 seconds for all electrified doors / key pads (IXG, DK-26).

blockedhttps://Blockedwww.aiphone.com/support/technical-support/aiphone-programming-questionnaire https://www.aiphone.com/products/ixg-series mailto:recruitingcenters@aiphone.com

FY26 Upgrades to Contracting – New Jersey Page 20 of 39

ENCLOSURE #6a, & 6b

Video Intercom Entry Control (EC) - IXG System Wiring Diagrams & Example Setup

18) Door-entrance station cameras to be connected to the CCTV system and shown on service specific open area television only. These cameras and desk-tenant stations require a PoE+ Switch connection. A license is needed to record door entrance station camera. Either recordability or viewability with be an option but not both. If more than 48 ports (or PoE++ ports) are required, add on the optional / secondary PoE+ Switch.

19) Door-entrance station mounting: If possible, mount door-entrance station on the side of the mullion flush to the exterior window. Purpose would be to try to limit the ability for the entrance station from being pulled off of the storefront.

20) Desk-tenant stations to be installed in each Military Service facility (minimum of 2, maximum of

8) for each Military Service recruiter identified in paragraph A.4. See Air Force Attachment “4a” for their desk-station requirements. Optional wall mounted desk-tenant stations should be placed free and clear of all Military Service accent walls (as identified on approved floor plan / AE drawings).

Wall Outlet (yellow data port jack) to desk-tenant station shall include an eight (8) foot yellow straight-through CAT 6 patch wire. In rare cases (as directed by a COE representative or on the approved floor plan / AE drawings) a wall mount for desk-tenant stations may be necessary (wall mount model = IXG-

FMK-2C7).

21) See paragraph G.7 for Door Hardware Schedule & release components.

22) All stranded low voltage wire (exit device, keypad, and door position switch) will be 18 AWG stranded wire with label / tag at each end for easy identification and troubleshooting. See ENCLOSURE #6a, 6b, 6c, and 6d for EC example components, wiring and layout diagrams.

23) See paragraph K. for PoE+ Switch & LSP Power supply requirements (hardwired on security board).

24) See communications paragraph E and ENCLOSURE #1a, 1b, 1c and 1d for locations and colors of data port jacks and CAT 6 wires.

25) No Public Access Secondary Doors: A secondary egress door that only Recruiting personnel use to enter the station. Typically, the public or potential recruits do not access thru this door. The “No public access doors” only requires the Securitron DK-26 Keypad with controller (vs the Aiphone door-entrance station). If the secondary egress is just an emergency only egress where no parties typically than neither the DK-26 or Aiphone door-station will be needed.

26) Door position switches to activate shared egress door(s) chime(s). Primary shared egress doors shall have a single-tone (e.g. - “ding”), and secondary shared egress door(s) shall have two-tones (e.g. - “ding-dong”).

FY26 Upgrades to Contracting – New Jersey Page 21 of 39

FY26 Upgrades to Contracting – New Jersey Page 22 of 39

Security Hardware / Application Requirements (EC & CCTV/NVR Systems): Contractor will advise the COE Representative on any unique site / office requirement(s) which will require any modifications to these specified security components.

k. Off network / offline Hardware.

l. Certified Integrators / Installers (warranty):

1. Aiphone - https://www.aiphone.com/kbtopic/ix-series-integrations-hanwha

2. Hanwha Vision STEP Partner - https://hanwhavisionamerica.com/partner-portal/

3. ASSA ABLOY (Rockwood, Securitron, Accentra, AdamsRite, and Pemko components) -https://www.assaabloydss.com/en/support/installation-and-service-partners/certified-integrators

m. EC and CCTV / NVR systems to be installed at the same time as they are integrated. Aiphone: IXG support tool file and IXG site specific configuration file to be loaded on the NVR (operating system drive).

n. NVR Computer Bios / Auto Start: Contractor to set / confirm NVR system BIOS settings are set to reboot automatically on power loss with MS Windows Auto Login (NO login password).

Bios instructions are as follows:

2. Power On the NVR and press "DEL" or "F1" or "F2" or "F10" to enter BIOS (CMOS) setup utility (the way to enter into BIOS Settings depends on the computer board manufacturer).

3. Inside BIOS menu, look under the following menus to find for a setting named “Restore on AC/Power Loss” or “AC Power Recovery” or "After Power Loss", “Advanced” or “ACPI” or "Power Management Setup".

4. Note: The “Restore on AC/Power Loss” setting can be found under different places inside BIOS setup according to computer manufacturer.

5. Set the “Restore on AC/Power Loss” setting to “Power On”.

6. Save and exit from BIOS settings.

o. Static IP Address Schedule: Manually set / confirmed by contractor.

a. Network PoE+ Switch(s) = 192.168.1.1-25 range.

b. Aiphone = 192.168.1.100-199 range – pre-set by Aiphone programming file.

c. CCTV / NVR = 192.168.1.200-255 range.

p. User IDs, Passwords and Door Access Codes: Contractor to coordinate with the COE Representative for setting / integrating user IDs, passwords, and temporary door access codes, including controlled distribution.

Contractor to ONLY assist the Military Services facility managers / ATO’s with programming the final door access codes.

1. Both the Aiphone IXG and Hanwha CCTV/NVR systems each require two (2) user / login levels each:

i.Aiphone IXG Support Tool:

• Administrator for installer (Recruiters will not have access).

• Property Manager for facility managers / ATOs (Recruiters will not have access).

ii.Hanwha / Wisenet Device Manager (CCTV): With these predefined user roles.

• Owner for installer / facility managers / ATOs (Recruiters will not have access).

• Viewer for onsite Recruiters / personnel.

iii.No MS Windows login passwords. Windows Auto Login only.

2. System User IDs & Passwords (EC, CCTV/NVR/Decoder, PoE+ Switch): User IDs / passwords shall be reset from defaults and set / integrated to match / align with each other. Admin and Owner user login level(s) & passwords to be set / integrated to match / align with each login level for all systems. Local Personnel / Recruiters will only have access to the Wisenet “Viewer” user.

3. Door Access Codes with Controlled Distribution: Contractor to program two (2) temporary and unique access codes for each Military Service present. The EC door-entrance station(s) (e.g. – A4611), and optional Securitron DK-26 individual keypad(s) codes to match #’s (e.g. – 4611) if both units are present.

Two (2) separate and unique access codes are necessary for each Military Service.

q. Camera & Door-Entrance Station Tools (Torx Tool): To be stored in a clear sleeve inside the Security cabinet at the Security Board.

r. System Documentation for CCTV/NVR Setup & License Tracking by Contractor (activated licenses for all cameras, EC door-entrance station cameras, etc.):

1. One copy of the system(s) hardware documentation / manuals / login details, and camera licenses are to be stored in a clear sleeve (along with the door-entrance station / camera tool (Torx tool) inside the Security cabinet at the Security Board.

2. Save the following files on the NVR (operating system drive):

i.Screen shots of all license keys and #’s (email second copy to the COE representative).

ii.Create Wisenet project file with current date.

iii.Run Wisenet camera / encoder report “ALL” (email second copy to the COE representative).

iv.Create camera config backup file.

s. Printed Exporting Video Instructions: Provide “how to” instructions on exporting video footage from NVR, via USB extension wire located next to keyboard. Printed instructions to be placed in clear

FY26 Upgrades to Contracting – New Jersey Page 23 of 39 plastic sleeve and mounted above NVR monitor on Security Board.

t. System Training:

1. A Training event will be scheduled and coordinated with the COE Representative for all Military Services / personnel (see paragraph A.4. for recruiter numbers). Installer(s) will submit to the COE a legible, dated roster with the trainer’s contact information, each Trainee’s name/rank, along with systems covered.

2. Minimum of a 1-hour training session MUST be provided as part of the installation by the contractor to ALL Military Services where the system(s) is installed.

3. On-site training to use “temporary” door access codes with Military Service personnel. Temporary access codes to be deleted / reprogrammed by Service Facility Managers / ATO’s after training is accomplished.

4. The training will cover minimum items:

i.EC System:

• Individual Service access codes with controlled distribution to the Facility Manager / ATO.

• System Features and operation of door-entrance station(s), keypads, desk-tenant stations.

• RJ45 port and wire colors.

• How to disconnect and reconnect desk-tenant stations.

• Basic troubleshooting options / methods.

• Ensure door release time range is set to 5-10 seconds for electrified doors / keypads.

ii.CCTV/NVR/Decoder with monitor displays:

• Review camera placements and system features / settings.

• Adjust each camera and Military Branch display for optimal egress / camera views.

• What to do if the CCTV system shuts down, or display monitors stop displaying.

• Demonstrate automatic restart / reboot NVR and display monitors in each office.

• Discuss and provide location of printed “how to” instructions on exporting video footage from NVR.

iii.Facility Managers / ATO’s: When present, detailed training for required (names / emails previously given by COE representative):

• Individual system software (Aiphone, Wisenet) instructional demo for logging in.

• Demonstrate features and operation on each system present.

• How to add/remove recruiter(s) door access code(s) on Aiphone IXG Support Tool and DK-26 control board.

• How to retrieve door entrance history / access control data from Aiphone IXG Support Tool.

• How to disconnect/reconnect desk-tenant stations.

•…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .