SOW Bowling Ball Return_19 Mar 26.pdf
PDF 175 KB Posted
- Attached to
- Bowling Ball Return
- Solicitation number
- FA480326Q0032
About this file
This is a Statement of Work (SOW) for the removal and installation of ball returns and masking units at the bowling center located in Building 1401 at Shaw Air Force Base in South Carolina, effective March 19, 2026. The contractor must provide all personnel, equipment, tools, materials, vehicles, supervision, and services necessary to complete the installation work.
The scope includes installation of eight ball return units that must meet specific minimum requirements: each unit must hold 12 balls in the upper tray with a lower rack system holding 8 additional balls positioned at least 2 inches above lane level, feature alternating left/right ball distribution, include high-speed hand dryers, provide single-point mechanical attachment for quick hood removal, offer multiple color options, incorporate hand intrusion safety devices with audible warnings, secure motors under hoods, include energy efficiency features, position motors and control boxes above lane level for maintenance access, provide reset buttons and spare parts kits, utilize existing electrical infrastructure, and maintain compatibility with Brunswick GSX Pinsetters and NEXGEN control boxes. The contractor must also install masking unit assemblies covering all 16 lanes with clearly indicated lane numbers, upper and lower graphic panels using industrial hook-and-loop attachment systems for customizable graphics, manual raise-and-lower capability operable by one person, standard frame dimensions of 89 feet by 114 inches, pinspotter coverage with LED lights for first and second ball registration, and existing electrical integration with Brunswick GSX and NEXGEN compatibility. The contractor must remove and dispose of all debris in accordance with local, state, and federal guidelines, shut down only one lane at a time during installation, maintain a one-year warranty and lifetime technical support, work during standard duty hours of 0730 to 1630 Monday through Friday excluding federal holidays, comply with all federal, state, and base safety regulations, coordinate with the 20th Force Support Squadron Bowling Center Manager (Ms. Terri Chapman), and submit written estimates for any repairs not listed in the scope of work prior to proceeding with additional work. Security requirements include employee listings, pass and identification items, criminal background checks taking 7-10 days minimum, compliance with FOUO regulations, physical security responsibility for government property, restricted area badge procedures requiring NACI investigations, and strict key control protocols with potential cost deductions for lost or duplicated keys.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFI_ Sources Sought.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CUI
STATEMENT OF WORK
FOR
Ball Returns and
Masking Units
19 March 2026
TABLE OF CONTENTS
PARAGRAPH
1.0
TITLE
DESCRIPTION OF SERVICES
PAGE(S)
2.0 GOVERNMENT FURNISHED PROPERTY 3
3.0 GENERAL INFORMATION 4
4.0
5.0
6.0
7.0
8.0
9.0
SECURITY REQUIREMENTS
FOR OFFICIAL USE ONLY (FOUO)
REPORTING REQUIREMENTS
PHYSICAL SECURITY
CONTROLLED/RESTRICTED AREAS
KEY CONTROL
STATEMENT OF WORK (SOW)
REMOVAL AND INSTALLION BALL RETURNS AND MASKING UNITS AT THE
BOWLING CENTER
DESCRIPTION OF SERVICES - The contractor shall provide all personnel, equipment, tools, materials, vehicles, supervision, and other items and services to install the Ball Returns and Masking Units in the bowling center, Building 1401 located at 416 Recreation Street Shaw AFB, SC 29152
1.1. Scope of Work - The contractor shall perform installation of the items listed below:
1.1.1: Ball Return Specifications "The 8 ball returns provided must meet the following minimum requirements:"
a. Ball return trays must hold 12 balls and has a lower rack system that must hold 8 additional balls and be at least 2” above lane level for ease of floor cleaning.
b. Ball returns must have mechanism for delivering alternating left/right distribution on rack. Ball Returns must have high-speed blower for hand dryer.
c. Ball return hoods must use a single mechanical attachment point to the lift, enabling quick, easy removal and access to motor, belts, and control box.
d. Ball return hoods must have multiple color options to compliment furniture design.
e. Ball returns must have a hand intrusion safety device that turns power off to the unit whenever a foreign object, such as a hand, is inserted into the ball exit. This safety device must also emit beeping noise when a foreign object, such as a hand, is inserted into the ball lift.
f. Ball return motors must be secured under the hood to prevent customer access.
g. Ball returns must have an energy efficiency feature that turns return motor on only when ball approaches and turns off as soon as ball exits.
h. Ball return motors and control boxes must be above lane level for easier access for repair and maintenance.
i. Must have a reset button and a spare parts kit.
j. Contractor will utilize the existing electrical from the circuit breaker box to the ball returns and ensure ball returns are fully operational upon completion of work.
k. Bowling ball lifts and masking units must be compatible with Brunswick GSX Pinsetters and NEXGEN control boxes.
1.1.2: Masking Unit Specifications
"The masking unit assembly provided must cover all 16 lanes and meet the following minimum requirements:"
a. Masking panels must clearly indicate lane numbers.
b. Must have a masking upper and lower graphic panel that must use industrial “hook and loupe” attachment method to secure the panels to the frames for ease of removal. Masking unit graphics must be fully customizable.
c. Masking units must be capable of being raised and lowered manually by one person.
d. Include upper and lower tier masking units must cover 16 lanes, each panel covering 2 lanes each. Frame must be standard size:
Length must measure 89’ x 114” from capping to top of masking unit.
e. Masking units must cover the pinspotters and visibly register first ball/second ball with LED lights.
f. Contractor will utilize the existing electrical from the circuit breaker box to the masking units and assure masking units are fully operational upon completion of work.
g. Bowling ball lifts and masking units must be compatible with Brunswick GSX Pinsetters and NEXGEN control boxes.
1.2. Services Not Covered-. The contractor shall notify facility manager of any repairs required that are not listed in the scope of work and if any of the additional repairs that need to be completed before continuing with the maintenance outlined in the scope of work.
1.2.1 The contractor shall furnish the COR and Contracting Officer a written estimate containing an itemized listing of all additional repairs that are required to return the above listed equipment to a safe and operational condition. The report shall contain a cost estimate of all repair work to include a labor and parts breakdown. The work contained in the report shall be performed only if approved in writing by the Contracting Officer.
1.3. Quality Assurance. - The government will periodically evaluate the contractor’s performance by appointing a representative(s) to monitor performance to ensure services are received. The government representative will evaluate the contractor’s performance through intermittent on-site inspections of the contractor's quality control program and receipt of complaints from base personnel.
2.0 Government Furnished Property and Services - The Government shall only provide water and electricity from existing sources.
3.0. General Information
3.0.1.All required work shall be coordinated through the 20th Force Support Squadron Bowling Center Manager (Ms. Terri Chapman, building 1401 Ext 803-895-2731), and the contractor shall coordinate with the site representative prior to commencement of any inspections or work under this contract.
a. Need support that provides one-year warranty and lifetime technical support
b. Contractor must remove and dispose of all debris off base and in accordance with all local, state, federal guidelines.
c. Contractor will only shut down one lane at a time to install ball returns and masking units.
3.0.2 Safety - All work shall be in accordance with Federal, State and Base Safety regulations.
3.0.3HOURS OF OPERATION - All non-emergency work shall be accomplished during the normal duty hours of 0730 through 1630, Monday through Friday, excluding US Government holidays or as agreed upon by the contract representatives.
• Shaw AFB recognizes the following holidays:
New Year’s Day 1 January Martin Luther King’s Birthday Third Monday in January
President’s Day Third Monday in February Memorial Day Last Monday in May Independence Day 4 July Labor Day First Monday in September Columbus Day Second Monday in October Veterans Day 11 November Thanksgiving Day Fourth Thursday in November Christmas Day 25 December
NOTE: Any of the above holidays falling on a Saturday will be observed on the proceeding Friday. Holidays falling on a Sunday will be observed on the following Monday.
4.0. SECURITY REQUIREMENTS FOR UNCLASSIFIED CONTRACTS
4.0.1 Listing of Employees - The contractor shall maintain a current listing of employees. The list shall include the employee's name, social security number and type of investigation if contract work involves unescorted entry to Air Force restricted areas or other sensitive areas designated by the installation commander. The list shall be provided to the Program Manager and sponsoring agencies Security Manager. An updated listing shall be provided when an employee's status or information changes.
4.0.2 Pass and Identification Items - The contractor shall ensure the pass and identification items required for contract performance are obtained for employees.
4.0.3 Background Checks - All contractor employees not falling into one of the categories listed in the preceding paragraph shall submit to a criminal background check accomplished by Shaw Air Force Base Security Forces prior to the employee being issued base access credentials. Failure to submit requested Contractor Listing of Employees as indicated can result in denial or delay of issuing base access credentials.
Processing criminal background checks takes, at a minimum, 7-10 days from time of submission.
4.0.4 Retrieving Identification Media - The contractor is responsible for retrieving all government-issued identification media from employees who depart for any reason before the contract expires; e.g. terminated for cause, retirement, etc. The contractor shall return retrieved items to the Security Forces Pass and Registration Office.
4.0.5 Traffic Laws - The contractor and its employees shall comply with base traffic regulations.
4.0.6 Weapons - Contractor employees are prohibited from possessing weapons, firearms, or ammunition, on themselves or within their contractor-owned vehicle or privately-owned vehicle while on Shaw Air Force Base.
5.0 For Official Use Only (FOUO) - The contractor shall comply with DoD 5400-7-R, Chapter 4, DoD Freedom of Information Act (FOIA) Program, requirements. This regulation sets policy and procedures for the disclosure of records to the public and for marking, handling, transmitting, and safeguarding FOUO material.
6.0 Reporting Requirements - Contractor personnel shall report to an appropriate authority any information or circumstances of which they are aware may pose a threat to the security of DOD personnel, contractor personnel, resources, and classified or unclassified defense information. Contractor employees shall be briefed by their immediate supervisor upon initial on-base assignment.
7.0 Physical Security - The contractor shall be responsible for safeguarding all government property and controlled forms provided for contractor use. At the end of each work period, all government facilities, equipment, and materials shall be secured.
8.0 Controlled/Restricted Areas - The contractor shall implement local base procedures for entry to Air Force controlled/restricted areas where contractor personnel will work. An AF Form 2586, Unescorted Entry Authorization Certificate, must be completed and signed by the sponsoring agencies Security Manager before a Restricted Area Badge will be issued.
Contractor employees must have a completed National Agency Check with written inquiries (NACI) investigation before receiving a Restricted Area Badge.
9.0 Key Control - The contractor shall establish and implement methods of making sure all keys issued to the contractor by the Government are not lost or misplaced and are not used by unauthorized persons. The contractor shall not duplicate any keys issued by the government.
9.0.1 The contractor shall immediately report to the site representative or Program
Manager any occurrences of lost or duplicated keys.
9.0.2 In the event keys, other than master keys, are lost or duplicated, the contractor may be required, upon written direction of the Contracting Officer, to re-key or replace the affected lock or locks without cost to the government. The government may, however, at its option, replace the affected lock or locks or perform re-keying and deduct the cost of such from the monthly payment due the contractor. In the event a master key is lost or duplicated, all locks and keys for that system shall be replaced by the government and the total cost deducted from the monthly payment due the contractor.
9.0.3 The contractor shall prohibit the use of keys, issued by the government, by any persons other than the contractor’s employees and the opening of locked areas by contractor employees to permit entrance of persons other than contractor employees engaged in performance of contract work requirements in those areas.
File details come from the government source that posted it. Updated .