This document includes a presolicitation notice and statement of work for architectural and engineering design services. The Veterans Health Administration seeks a firm-fixed price design contract from a Service-Disabled Veteran-Owned Small Business for complete construction documents including drawings, specifications, reports and construction period services. The scope includes infrastructure upgrades to information technology systems, networking, electrical, HVAC, and security systems at the VA Manchester Medical Center. Responses are due by July 29, 2022. Firms will be evaluated on their specialized experience in similar network and infrastructure projects, professional qualifications of staff, capacity to complete the design within 420 calendar days of award, past performance, and knowledge of the project locality. The selection process will include evaluating submissions against these primary criteria, discussions with the top firms, and negotiations with the highest rated firm. The award is for a 100% SDVOSB set-aside contract valued between $20-50 million.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Tab1-EUO-Room TR-DC-Assessment

IT INFRASTRUCTURE SURVEY
OITFMS for Column H OIT/FMSOITOIT/FMSOIT/FMSOITOITOIT
VA DISTRICT (1-5)VA IT TERRITORY (T1-T5)VHA VISN NumberVHA Station NumberOfficial Station NameSITE-Specific Station Site (Such as Division, CBOC, etc.)BUILDING Number & floorTR (Closet) or Data Center (DC) ROOM NUMBERROOM TYPEAREAS SERVEDROOM AREA TYPE CATEGORYUTP CABLE TYPE
(enter whole # to represent %)EVALUATION UTP CABLE TYPE-ROOMPATCH PANEL (Enter Whole Numbers)Patch Panel TypeEVALUATION PATCH PANELS-ROOMEVALUATION-PATCH CABLESFIBER-Enter Whole Numbers or Pick CategoryROOM FIBER EVALUATIONSatellite Site-LAN-Enter Whole Numbers or Pick Category Note: Satellite Sites are defined as sites "non VAMC" sites, such as CBOC's, Contract Clinics, Leased Space, Vet CentersSatellite-WAN
(enter circuit and outlet quantity in whole numbers)-VHAMissing DataNormal Power 208V 1ɸ (enter circuit and outlet quantity in whole numbers)-VHANormal Power 208V 3ɸ
(enter circuit and outlet quantity in whole numbers)-VHAEmergency Power 120V 1ɸ
(enter circuit and outlet quantity in whole numbers)-VHAMissing DataEmergency Power 208V 1ɸ
(enter circuit and outlet quantity in whole numbers)-VHAEmergency Power 208V 3ɸ
(enter circuit and outlet quantity in whole numbers)-VHAElectrical Bonding Bussbar Installed Yes/NoAre Outlets Adequate or Inadequate for Go-Live Readiness?Are Circuits Adequate or Inadequate for Go-Live Readiness?How Many UPS's Are Present?UPS (VHA)EVALUATION-UPSRoom HVACRoom HumidityCabinet/Rack ServerTR Closet or Data Center Dimensions (VHA), Measure to 2 decimal placesRoom ConditionEVALUATION-Room Condition ImpactSpace Issue CommentsEVALUATION SPACE DIMENSIONSCOMMENTS
Patient Care (Direct)Indirect and Non-Patient CareCat 3Cat 5Cat 5eCat 6Cat 6ATotal (Calculated)Is the Cable in the Room Cat 5e or Greater? If so, Cabling is considered Adequate for Go-Live Readiness. If not, Cabling is Inadequate.WALL Mount Total # of PortsRACK/FRAME Mount Total # of PortsIn Cabinet Mount Total # of PortsTOTAL # of Ports (Calculated)66-block Punch Down110-block Punch DownModular (RJ-45)Are the Patch Panels Adequate or Inadequate for Go-Live Readiness?Estimated UTP Cable Count
Whole Number EstimateDo patch cables in the closet meet or exceed the category ratings for their fixed cabling channels? YES-ADEQUATE/NO-INADEQUATE If NO, mismatched patch panels will require OIT remediation.Single-Mode StrandsSingle-Mode Fiber Run LengthSingle Mode Fiber Run Termination PointMulti-Mode StrandsMulti-Mode Fiber Run LengthMulti- Mode Fiber Run Termination PointIs the in the Room Fiber Adequate or Inadequate Go-Live Readiness?Single-Mode StrandsSingle-Mode Fiber Run LengthSingle Mode Fiber Run Termination PointMulti-Mode StrandsMulti-Mode Fiber Run LengthMulti- Mode Fiber Run Termination PointNumber of CircuitsAre there at least two diverse WAN circuits upstream from each CBOC? Yes/NoCircuit 1-BandwidthCircuit 1- TypeCircuit 1-CIR-Committed Information RateDemarcation (Bldg, Room)Describe Circuit 1 Path and ProviderCircuit 2-BandwidthCircuit 2- TypeCircuit 2-CIR-Committed Information RateDemarcation (Bldg, Room)Describe Circuit 2 Path and ProviderAre Satellite WAN Circuits Adequate/ Inadequate for Go-Live Readiness?15 Amp
Note: Data Center Rooms also include rooms with any servers that have non-OIT maintenance on the server.Clinic(s)/ Out-Patient ServicesDiagnostic (Imaging, Labs etc.)Procedure/Treatment (Surgery, ED, Endo, Chemo, etc.)InpatientPharmacyResidential (Dom, CLC, TR, Hoptel, etc.)Specific Area Listing (Free Text)Care Support (SPS,Transcription, etc.)Administrative/Office (Dir, Finance, FM, etc.)Specific Area Listing (Free Text)Clinical, Non-Clinical, or Mixed Clinical/Non-ClinicalWhole Number Count of Patch Panel TypeWhole Number Count of Patch Panel TypeWhole Number Count of Patch Panel TypeAre all Patch Panels Cat 5e or Greater? Yes/NoCat3Cat5Cat5eCat 6Cat6AIn useInstalledFiber TypePerformance 10 GbE (Building to Building)OS-Distance to Termination Point (Measured Length in feet)OS- Termination Point
(Building / Room)In useInstalledFiber Type OM1 (Orange)Fiber Type (OM2) OrangeFiber Type (OM3) AquaFiber Type (OM4) AquaPerformance 40 GbE (Intra-Building)OM-Distance to Termination Point (Measured Length in feet)OM- Termination Point
(Building / Room)In useInstalledFiber TypePerformance 10 GbE (Building to Building)OS-Distance to Termination Point (Measured Length in feet)OS- Termination Point
(Building / Room)In useInstalledFiber TypeOM-Distance to Termination Point (Measured Length in feet)OM- Termination Point
(Building / Room)In use CircuitsTotal Installed CirucuitsNumber of Outlets In UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets In UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets In UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets in UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets in UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets in UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets in UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets in UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets in Use

* Does the room comply with the Telecommunications Infrastructure Standard?Adequate is defined as physical space exists to accommodate installation of commercially acquired racks, network switches, and patch panels.

An example of a "makeshift" installation would be where wall mounted patch panels are being used due to no rack space available. Or, "homemade" racks are being used to mount equipment due to size constraints.

Enter Either TR for Telecom Room (Closet) or DC for Data CenterYES/NOYES/NOYES/NOYES/NOYES/NOYES/NOYES/NOYES/NOEnter Clinical, Non-Clinical, or Mixed (Clinical and Non-Clinical)Mark Adequate or InadequateMark Adequate or InadequateWhole #Whole #OS1, OS2Select Either
OS1 – 10G up to 10Km OS2 – 100G up to 200KmWhole #Whole #Strand Count, Whole #Strand Count, Whole #Strand Count, Whole #Strand Count, Whole #Select One Below

OM1 – 1Gb up to 300M OM2 – 1Gb up to 600M OM3 – 40-100Gb up to 100M

OM4 – 100Gb up to 150MMark Adequate or InadequateWhole #Whole #OS1, OS2Select Either
OS1 – 10G up to 10Km OS2 – 100G up to 200KmWhole #Whole #OM1, OM2, OM3, OM4Whole #Mark Adequate or Inadequate
5T1VA Puget Sound(example)Seattle Division(example)1101TRMixed51550300100%Adequate288Inadequate1443144286YES412OS11/ B7010
1T11608ManchesterMedical Center1 - BasementE28TRNNNNYNPharmacyNYPharmacy AdminClinical0000100100%Adequate02400240005NY00000n/a00000n/a8
1T11608ManchesterMedical Center15 - BasementD04ADCYNYNNNPT/OT, Prosthetics, TBI, Cardiology, PainYNTelehealth, Care in the CommunityClinical0010000100%Inadeqaute144480062412010NN00000n/a00000n/a10
1T11608ManchesterMedical Center1-First floorW154BTRNNNNNNN/ANNAdmin, PACS, Fire alarm, CamerasNon-Clinical2507500100%Inadeqaute8400084028834NN00000n/a00000n/a4
1T11608ManchesterMedical Center1-First floorW154DTRYYNNNNPhlembotomy, NFSNYPolice, Volunteer, DOV, Travel, BenefitsClinical0010000100%Inadeqaute3840038412020NN00000n/a00000n/a6
1T11608ManchesterMedical Center1-First floor (MH)SW101TRYNNNNNMental Health, Primary CareNYMH and PC Admin supportMixed0010000100%Inadeqaute058805881708NY00000n/a00000n/a12
1T11608ManchesterMedical Center1E-First floor (CSB)SE145TRYNYNNNUrgent Care and Mental HealthNYUC and MH Admin supportMixed0000100100%Adequate05675765762010NN00000n/a00000n/a4
1T11608ManchesterMedical Center15 - First floorD104ATRYNNNNYCLC and Recreation TherapyYNNurse call and Wonder guardMixed0010000100%Inadeqaute144480062412010NN00000n/a00000n/a10
1T11608ManchesterMedical Center18 - First floor145TRYNNNNNPrimary CareNYPC Admin supportClinical0010000100%Inadeqaute300003000022NN00000n/a00000n/a10
1T11608ManchesterMedical Center1-Second floorW256ATRYYNNNNDental and Laboratory servicesYYSPS, Chapel and LogisticsMixed0010000100%Adequate4800048016024NN00000n/a00000n/a6
1T11608ManchesterMedical Center15 - Second floorD252TRYNNNNNSACNYSAC Admin supportMixed0010000100%Adequate24700247120103NN00000n/a00000n/a8
1T11608ManchesterMedical Center1-Third floorN359ATRYNNNNNOptometry and AudiologyNYOccupational Health and Call CenterMixed409600100%Inadeqaute6080060824026NN00000n/a00000n/a10
1T11608ManchesterMedical Center1-Forth floorN457ATRYNYNNNOR and PACUYNOR and PACU pre/post op examsClinical4006000100%Inadeqaute4080040816727NN00000n/a00000n/a6
1T11608ManchesterMedical Center1-Fifth floorW560ATRYNNNNNMental HealthNYMental Health Admin supportClinical509500100%Inadeqaute1392001392122430NN00000n/a00000n/a8
1T11608ManchesterMedical Center1-Sixth floorW645ATRYNNNNNWomens Health, Patient SafetyNYDirectors Office, QM, EducationMixed0010000100%Adequate360003603024NN00000n/a00000n/a6
1T11608ManchesterMedical Center3S16TRNNNNNNBuilding to be demolishedNYIRM/OIT0%00000n/a
1T11608ManchesterMedical Center4E17TRNNNNNNBuilding to be demolishedNYHR0%00000n/a
1T11608ManchesterMedical Center615TRNNNNNNNO PATIENT CARENYFMS, Safety, GEMS, EMNon-Clinical0010000100%Inadeqaute00000n/a00000n/a4
ManchesterSomersworth CBOCGround levelTRYYNNNNPrimary care, MH, NutritionNNN/AClinical0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%5307000000112
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%

DropDown Values

Space UseUPSHVACSPACEDISTRICTTERRITORY
ADMINInstalled - AdequateInstalled - AdequateYESAdequate - Room for expansion1T1
CLINICALInstalled - InadequateInstalled - IndequateNOAdequate - No room for expansion2T2
OtherNot InstalledNot InstalledInadequate - makeshift installations3T3
ExcludeMissing dataMissing data4T4
5T5

Tab2-DC Room Data Collection

OITFMSOITOITOIT/FMSOITFMS (with OIT as needed)FMSOITOIT
VA DISTRICT (1-5)VA IT TERRITORY (T1-T5)VHA VISN NumberVHA Station NumberOfficial Station NameSITE-Specific Station Site (Such as Division, CBOC, etc.)BUILDING NumberCloset ROOM NUMBERROOM TYPE is Data CenterData Center Assessment Team
Site LayoutRacksSPACE EVALUATIONENVIRONMENTALENVIRONMENTALCOOLING EVALUATIONEVALUATION COMMENTSCable DistributionCABLING AND DISTRIBUTION EVALUATIONWAN
GENERAL NOTES: FOR MEASUREMENTS, USE 2 DECIMAL PLACES. FOR COUNTS, WHOLE NUMBERSARCHITECTUREARCHITECTUREARCHITECTUREARCHITECTUREMECHANICALMECHANICAL-SYSTEM 1 SECTIONMECHANICAL-SYSTEM 2 SECTIONMECHANICAL-SYSTEM 3 SECTIONMECHANICAL-TOTAL ROOM COOLING CAPACITYENVIRONMENTAL/MECHANICALENVIRONMENTAL/MECHANICALTELECOMMUNICATIONSTELECOMMUNICATIONSTELECOMMUNICATIONS
Date Of Survey (MM/DD/YYYY)Survey Team -List First and Last NamesSite Plan Yes or NoFloor Plan Yes or NoFrom TR/Closet Tab: Rm. Length (ft)From TR/Closet Tab: Rm. Width (ft)Number of 2-Post RacksNumber of 4 Post RacksNumber of CabinetsTotal Number of Racks (all types) and CabinetsMeasure (ft/in)/Check Access Path Clearance for moving cabinets/rack in and out of doors. Any issue with installing 84.6" high by 30"wide cabinets on pallet? Yes/NoDoes site have a raised floor Yes/NoRaised Floor Height (ft)Do you have enough space and access clearance (Adequate/Inadequate) to deploy 4 additional cabinets?Description of Cooling Distribution System Description Categories: Fully Ducted , Hot-Cold Aisle, No Air ContainmentNumber of UnitsUnit Redundancy: Select from None (N), Redundant (N+1), Parallel Redundant (2N), OtherSystem 1 MakeSystem 1 ModelSystem 1 Age (from Manufacturer Datecode which gives Mfr Date or Install Date)System 1-Total Room Available Cooling Capacity (kW) Note: From TR/Closet Tab, Convert "Tons to kW" .System 2 MakeSystem 2 ModelSystem 2 Age (from Manufacturer Datecode which gives Mfr Date or Install Date)System 2-Total Room Available Cooling Capacity (kW) Note: From TR/Closet Tab, Convert "Tons to kW" .System 3 MakeSystem 3 ModelSystem 3 Age (from Manufacturer Datecode which gives Mfr Date or Install Date)System 3-Total Room Available Cooling Capacity (kW) Note: From TR/Closet Tab, Convert "Tons to kW" .Total Room Available Cooling Capacity (kW) Note: after considering Redundancy.Total Critical Load on Cooling System (UPS Output Load) (kW)Available Cooling Capacity (kW) = (Total Available Cooling)-(Total Critical Load on Cooling System)Cooling System Sufficient to support additional workload (Adequate/Inadequate)Cooling Comments (Enter Data for additional cooling systems here)Telecommunications cable trays (Yes/No)Structured cabling system used (Yes/No)Dedicated Redundant Horizontal Distribution Area for the Main Computer Room (Yes/No)Dedicated Redundant Main Distribution Area (Yes/No)Is Cabling and Distribution Adequate/Inadequate for Data Center?Number of CircuitsAre there at least two diverse WAN circuits upstream from each VAMC? Yes/No
5T1VA Puget Sound(example)Seattle Division(example)1101DC