About this file

This document is a Statement of Work (SOW) Appendix B related to a federal contract opportunity for Camera Inspection and Video Cleaning Services for the Tioga Dam and Mansfield Levee System in Pennsylvania.

The U.S. Army Corps of Engineers, Baltimore District intends to issue a Request for Proposal for these services, which include performing camera video inspection and any required cleaning of three separate features at Tioga Dam (8-inch Tile Drain, Left Abutment Drain, and Right Abutment Drain) as well as inspecting utility lines at the Mansfield Levee. The contract is estimated to be a 365-calendar day Firm-Fixed-Price contract under NAICS code 541990. This will be a full and open competitive procurement, evaluated using a Best Value Tradeoff source selection process. The Government anticipates releasing the solicitation on or about August 15, 2024 with a closing date around September 16, 2024, and a pre-proposal conference on or about August 27, 2024.

View the file

Other files

File Type Posted
SOW_APPENDIX-A.pdf PDF
SOW_APPENDIX-D.pdf PDF
SOW .pdf PDF
SOW_APPENDIX-C.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX B

MANSFIELD LEVEE

PLANS, PROFILES, SECTIONS, AND DETAILS

Figure 18: Mansfield Levee Key Plan.

Levee Stations 34+25 to 54+00 Figure 20

Levee Stations 54+00 to 80+00 Figure 21; Figure 22

Levee Stations 80+00 to 96+00 Figure 23

Levee Stations 96+00 to 112+00 Figure 24

Levee Stations 112+00 to 129+00 Figure 25

Levee Stations 129+00 to 146+00 Figure 26

Levee Stations 146+00 to 152+25 Figure 27

Figure 19: Mansfield levee pertinent features.

Figure 20: Plan sheet highlighting inspection features (toe-drain).

MANSFIELD LEVEE TOE-DRAIN

Figure 21: Plan sheet highlighting inspection features (toe-drain, DS-2, PS-2, and PS-3).

MANSFIELD LEVEE TOE-DRAIN,

DRAINAGE STRUCTURES, AND

PUMP STATIONS

Figure 22: Plan sheet highlighting inspection features of DS-2.

MANSFIELD LEVEE TOE-

DRAIN, DRAINAGE

STRUCTURES, AND

PUMP STATIONS

Figure 23: Plan sheet highlighting inspection features (toe-drain).

TOE-DRAIN

Figure 24: Plan sheet highlighting inspection features (toe-drain, DS-1, and PS-1).

MANSFIELD

LEVEE TOE-

DRAIN,

DRAINAGE

STRUCTURE,

PUMP

STATION

Figure 25: Plan sheet highlighting inspection features (toe-drain).

Figure 26: Plan sheet highlighting inspection features (toe-drain).

Figure 27: Plan sheet highlighting inspection features (toe-drain).

Figure 28: Mansfield Levee profile showing toe-drain pipe with manholes (STA 34+25 to STA 62+07).

Figure 29: Mansfield Levee profile showing toe-drain pipe with manholes (STA 69+00 to STA 103+00).

Figure 30: Mansfield Levee profile showing toe-drain pipe with manholes (STA 103+00 to STA 137+00).

Figure 31: Mansfield Levee profile showing toe-drain pipe with manholes (STA 137+00 to STA 146+30).

Figure 32: Drainage Structure No. 1 plan, profile, sections, and details.

DRAINAGE STRUCTURE NO. 1

Figure 33: Drainage Structure No. 2 plan, profile, and sections.

DRAINAGE

STRUCTURE NO. 2

Figure 34: Drainage Structure No. 2 details.

DRAINAGE

STRUCTURE

NO. 2

Figure 35: Pump Station 1 and 2 plan and profile (inspection features).

PUMP STATION

NO. 1 AND NO. 2

Figure 36: Pump Station 3 plan and profile (inspection features).

PUMP STATION NO. 3

Figure 37: Control manhole at pump station 3, outlet structure at pump stations 2 and 3 details.

CONTROL MANHOLE

(PS NO. 3)

File details come from the government source that posted it. Updated .