This document contains Questions and Answers (Q&As) related to a pre-solicitation for a Mobile Pallet Racking System contract opportunity with the Department of the Army Alaska Army National Guard. The key details are:

The government requires the installation of a new mobile pallet racking system consisting of two 47'1 1/2" x 16'6 7/8" rows with 4 beam levels per bay, for a total of 40 beam levels and 80 pallet positions. The existing pallet racking will be removed and re-installed into one of the mobile carriages. The mobile carriages must be able to hold 16,000 lbs per bay and 160,000 lbs in total. The rails must be able to withstand 10,000 lbs of forklift traffic. The contractor is responsible for all installation, electrical wiring, debris removal, and providing a one-year warranty. A site visit is required to obtain accurate measurements.

View the file

Other files

File Type Posted
MobilePalletRackingSystem_QandAs_2.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

a. Is there a drawing of the exis�ng or proposed layout? No but I can provide a photo of what we currently have.

c. Is there a specific type or style of gra�ng required? Waterfall Wire decking

d. Surface mounted rails are not compa�ble with seismic rated mobile pallet racking carriages. Alaska is a seismic rated area that will require recessed rails to support the an�-�p and other seismic features.

Can the rails the recessed? Yes

e. Are the specs of exis�ng racking known? Sta�onary and mobile aisles require different seismic calcula�ons and frequently require different racking to support the increased dynamic forces. 4K per beam level and 12K per bay.

f. Assuming the exis�ng racking is suitable, the dimensions of exis�ng beams and upright type will be needed to accurately source addi�onal beams that are compa�ble. Is this informa�on available?

Informa�on can be obtained during site visit.

j. What type(s) of electrical power are available? 120 VAC up to 480 VAC, both single phase and 3 phase depending on panel loca�on, but that’s available in the building.

x. Is there a specific �me-to-repair guideline or requirement? 48 hours max preferably

31’.2”

7’.4”

This middle sec�on will need to be put into a mobile carriage and iden�cal racking will need to be sourced with mobile carriage. Both end sec�ons will remain sta�onary.