Sources Sought_Block and Stack_DRAFT Attachment_24.04.03 (1).pdf
PDF 518 KB Posted
- Attached to
- DC Courts Recorder of Deeds Modernization
- Solicitation number
- DCSC-24-RFP-223
- Issued by
- District of Columbia Government
About this file
This document appears to be a set of draft architectural drawings and plans for the renovation of the 515 D St NW building in Washington, DC. The plans include detailed floor plans for the basement, first, second, third, and fourth levels, showing the proposed layout and use of the various spaces, including offices, mechanical rooms, restrooms, and storage areas.
The related federal contract opportunity is a special notice from the District of Columbia Courts (the Courts) seeking qualified contractors to provide Design-Build (D-B) services for the Historic Recorder of Deeds (RoD) Building Modernization Project. The Courts is conducting a market survey and is interested in receiving responses from interested contractors by May 10, 2024. No funds are available to fund the preparation of responses, and any information submitted is strictly voluntary, with no obligation for the Courts to award a contract.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| DC Courts_Sources Sought_Recorder of Deeds_20240405-R3.1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
DN
DN
DN
1 2 3 4 5 6 7 8
A
B
C
D
E
AREA LEGEND
BUILDING OPERATIONS
BUILDING
STORAGE
BUILDING
STORAGE
MAIL ROOM
(COLLECTION AND
MAILBOXES)
ELECTRICAL
CLOSET
TELECOM/
SECURITY
CLOSET
WOMEN'S
RESTROOM
(PUBLIC)
MEN'S
RESTROOM
(PUBLIC)
JANITOR'S
CLOSET
EMERGENCY
ELECTRICAL
ROOM
MAIN ELECTRICAL
ROOM
BUILDING
MANAGAMENT
OFFICE
MECHANICAL
PUMP ROOM
BUILDING
ENGINEER
OFFICE AND
LOCKERS
TRASH SUMPTRASH
SECURITY
EQUIPMENT
ROOM
HOUSEKEEPING
RAMP
DOWN
EXISTING
ELECTRICAL AND
TELECOM POS
PROPOSED
NATURAL GAS
POS
3/16" = 1'-0"1/22/24 BASEMENT AREA PLAN
515 D St NW, Washington, DC 20001
MECHANICAL
ROOM (CHILLERS,
CHILLED WATER
PUMPS,
CONDENSER
WATER PUMPS,
AHU)
MECHANICAL
ROOM (CHILLERS,
CHILLED WATER
PUMPS,
CONDENSER
WATER PUMPS,
AHU)
DRAFT
FOR CONCEPT ONLY
DN
1 2 3 4 5 6 7 8
A
B
C
D
E
4873 SF
DGS SUITE
AREA LEGEND
BUILDING OPERATIONS
DGS SUITE
SECURITY OFFICE
VENDING
UNISEX
RESTROOM
(PUBLIC)
UNISEX
RESTROOM
(PUBLIC)
JANITOR'S
CLOSET
ELECTRICAL
CLOSET
TELECOM/
SECURITY
CLOSET
WAITING/
RECEPTION AREA
MAIN ENTRANCE
(ADA COMPLIANT)
EMPLOYEE
ENTRANCE
MECHANICAL
SHAFT
MECHANICAL
SHAFT
3/16" = 1'-0"1/22/24 LEVEL 1 AREA PLAN
515 D St NW, Washington, DC 20001
DGS SUITE
REQUIRED PROVIDED
5000 USF 4837 USFDRAFT
A
B
C
D
E
328 SF
FUTURE TENANT
727 SF
FUTURE TENANT
918 SF
FUTURE TENANT
578 SF
FUTURE TENANT
2319 SF
FUTURE TENANT
339 SF
SHARED LUNCHROOM
(PRIVATE)
512 SF
FUTURE TENANT
AREA LEGEND
BUILDING OPERATIONS
FUTURE TENANT
HISTORICAL
SHARED LUNCHROOM
(PRIVATE)
AVAILABLE SUITE
2551 SF
MECHANICAL
SHAFT
MECHANICAL
SHAFT
ELECTRICAL
CLOSET
TELECOM/
SECURITY
CLOSET
WOMEN'S
RESTROOM
(PUBLIC)
MEN'S
RESTROOM
(PUBLIC)
JANITOR'S
CLOSET
MOTHER'S ROOM
(BUILDING
COMMON)
UNISEX
RESTROOM
(PUBLIC)
3/16" = 1'-0"1/22/24 LEVEL 2 AREA PLAN
515 D St NW, Washington, DC 20001
SHARED LUNCHROOM
FUTURE TENANT
REQUIRED PROVIDED
330 USF 339 USF
2314 USF 2314 USF
512 USF 512 USFFUTURE TENANT
FUTURE TENANT 2551 USF 2551 USF
B
C
D
E
2677 SF
ACCESS TO JUSTICE
320 SF
SHARED LUNCHROOM
(PRIVATE)
3280 SF
CRIME VICTIMS
COMPENSATION
AREA LEGEND
BUILDING OPERATIONS
ACCESS TO JUSTICE
CRIME VICTIMS COMPENSATION
SHARED LUNCHROOM (PRIVATE)
MECHANICAL
SHAFT
MECHANICAL
SHAFT
ELECTRICAL
CLOSET
TELECOM/
SECURITY
CLOSETWOMEN'S
RESTROOM
(PUBLIC)
MEN'S
RESTROOM
(PUBLIC)
JANITOR'S
CLOSET
UNISEX
RESTROOM
(PRIVATE) HOIST ACCESS
ROOM
3/16" = 1'-0"1/22/24 LEVEL 3 AREA PLAN
515 D St NW, Washington, DC 20001
ACCESS TO JUSTICE
CRIME VICTIMS
SHARED LUNCHROOM
REQUIRED PROVIDED
3280 USF 3280 USF
330 USF 320 USF
1890 USF 2677 USF
FUTURE TENANT
FUTURE TENANT
FUTURE TENANT
FUTURE TENANT
B
C
D
E
EMERGENCY
GENERATOR AND
EMERGENCY
ELECTRICAL
ROOM
MECHANICAL
ROOM (BOILERS,
COOLING
TOWERS,
BOILERS, HHW
PUMPS)
ELEC.
CLOSET
ELEVATOR
OVERRUN
ELEVATOR
CONTROLS
CLOSET
ELEVATOR
CONTROLS
CLOSET
MECHANICAL
ROOM (AIR
HANDLING UNIT)
JANITOR'S
CLOSET
MECHANICAL
SHAFT
MECHANICAL
SHAFT
HOIST
DOOR
AREA LEGEND
BUILDING OPERATIONS
UNISEX
RESTROOM
MAIN ELECTRICAL
ROOM
3/16" = 1'-0"2/13/24 LEVEL 4 AREA PLAN
515 D St NW, Washington, DC 20001
| Sheets |
| AR1 - BASEMENT AREA PLAN |
| AR2 - LEVEL 1 AREA PLAN |
| AR3 - LEVEL 2 AREA PLAN |
| AR4 - LEVEL 3 AREA PLAN |
| AR5 - LEVEL 4 AREA PLAN |
File details come from the government source that posted it. Updated .