Solicitation Amendment - N4215826QE0180001.pdf
PDF 2 MB Posted
- Attached to
- NNSY PURE WATER TANKS 800 GAL
- Solicitation number
- N4215826QE018
About this file
This is a Request for Quote (RFQ) for two 800-gallon stainless steel pure water tanks issued by Norfolk Naval Shipyard under solicitation number N4215826QE0180001. The solicitation is designated for Women-Owned Small Business (WOSB) with a 100% set-aside. The offering period closes on March 31, 2026, at 11:00 AM local time, with delivery required by June 30, 2026, to two locations: Norfolk Naval Shipyard (Building 276, Portsmouth, VA) and Pearl Harbor Naval Shipyard (Bldg 167-1, Pearl Harbor, HI).
The two line items require delivery of identical 800-gallon pure water tanks manufactured in accordance with detailed Statement of Work specifications and certifications. The tanks must be stainless steel Grade 316 horizontally oriented cylindrical vessels with elliptical end caps, designed to ASME Boiler and Pressure Vessel Code Section VIII Division 1 standards. Key technical requirements include: design pressure of 30 psig, vacuum design capacity of 29 inches Hg, normal operating pressure of 20 psig maximum, operating temperature range of -20°F to 120°F, and 60 GPM flowrate capability. The tanks must include integral lift lugs rated for 3:1 yield and 5:1 ultimate load factors, comprehensive piping assemblies (drain/suction, fill, sample, vent, relief valve, nitrogen supply, and pressure monitoring connections), liquid level and temperature monitoring equipment, and a control enclosure with process meters. All materials must be mercury-free and meet stringent cleanliness and detrimental material requirements per MIL-STD-2041 and MIL-STD-767. Vendors must provide extensive certifications including hydrostatic testing at 33 psig, calibrated tank fill validation, sensor and RTD operational verification, and weight documentation. This is a firm fixed-price commercial product acquisition evaluated on technical acceptability, price, and past performance using the Supplier Performance Risk System (SPRS) methodology.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| TECHNICAL CAPABILITIES STATEMENT.pdf | ||
| 52-212-1 Addendum.pdf | ||
| Solicitation Amendment N4215826QE0180001 SF 30.pdf | ||
| STATEMENT OF WORK.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WOMEN-OWNED SMALL
BUSINESS (WOSB)
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES
1. REQUISITION NUMBER PAGE 1 OF
2. CONTRACT NUMBER 3. AWARD/EFFECTIVE
DATE
4. ORDER NUMBER 5. SOLICITATION NUMBER 6. SOLICITATION ISSUE
DATE
7. FOR SOLICITATION
INFORMATION CALL:
a. NAME b. TELEPHONE NUMBER (No collect calls)
8. OFFER DUE DATE/
LOCAL TIME
9. ISSUED BY
13b. RATING
14. METHOD OF SOLICITATION
CODE
15. DELIVER TO 16. ADMINISTERED BY CODE
18a. PAYMENT WILL BE MADE BY CODE17a. CONTRACTOR/
OFFEROR
CODE
FACILITY
CODE
CODE
TELEPHONE NUMBER
17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT SUCH ADDRESS IN
OFFER
18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a UNLESS BLOCK
BELOW IS CHECKED
REQUEST
FOR QUOTE
(RFQ)
INVITATION
FOR BID
(IFB)
REQUEST
FOR
PROPOSAL
(RFP)
SEE ADDENDUM
19.
ITEM NUMBER
20.
SCHEDULE OF SUPPLIES/SERVICES
21.
QUANTITY
22.
UNIT
23.
UNIT PRICE
24.
AMOUNT
(Use Reverse and/or Attach Additional Sheets as Necessary)
25. ACCOUNTING AND APPROPRIATION DATA 26. TOTAL AWARD AMOUNT (For Government Use Only)
28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN
COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH
AND DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND
ON ANY ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS
SPECIFIED
29. AWARD OF CONTRACT: REFERENCE OFFER
DATED . . YOUR OFFER ON SOLICITATION
(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE
SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:
30a. SIGNATURE OF OFFEROR/CONTRACTOR
30b. NAME AND TITLE OF SIGNER (Type or print) 30c. DATE SIGNED
31a. UNITED STATES OF AMERICA (SIGNATURE OF CONTRACTING OFFICER)
31b. NAME OF CONTRACTING OFFICER (Type or print) 31c. DATE SIGNED
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
STANDARD FORM 1449 (REV. 11/2021)
Prescribed by GSA - FAR (48 CFR) 53.212
10. THIS ACQUISITION IS UNRESTRICTED OR
NORTH AMERICAN
INDUSTRY CLASSIFICATION
STANDARD (NAICS):
SIZE STANDARD:
13a. THIS CONTRACT IS A
RATED ORDER UNDER
THE DEFENSE PRIORITIES
AND ALLOCATIONS
SYSTEM - DPAS (15 CFR 700)
SET ASIDE: % FOR:
11. DELIVERY FOR FREE ON
BOARD (FOB) DESTINATION
UNLESS BLOCK IS MARKED
SEE SCHEDULE
12. DISCOUNT TERMS
ARE ARE NOT ATTACHED
ARE ARE NOT ATTACHED
27a. SOLICITATION INCORPORATES BY REFERENCE (FEDERAL ACQUISITION REGULATION) FAR 52.212-1, 52.212-4. FAR 52.212-3
AND 52.212-5 ARE ATTACHED. ADDENDA
27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA
8(A)
ECONOMICALLY
DISADVANTAGED
WOMEN-OWNED SMALL
BUSINESS (EDWOSB)
SERVICE-DISABLED
VETERAN-OWNED
SMALL BUSINESS
(SDVOSB)
HUBZONE SMALL
BUSINESS
SMALL BUSINESS
NOTE: OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30.
Section A - Solicitation/Contract Form
6022ZN01 and 6022ZN02 Pure Water Tanks
N4215826QE0180001
Section B - Supplies or Services & Prices or Costs
Additional Information/Notes
Item Supplies/Service Quantity Unit Unit Price Amount
PURE WATER TANK,
800 GALLON,
MANUFACTURED IN ACCORDANCE WITH ATTACHEMENT
(A) SOW SPECIFICATIONS
CERTIFICATIONS REQUIRED PER ATTACHMENT (B)
NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD unique identification or a DoD recognized unique identification equivalent.
Pricing Arrangement: Firm Fixed Price
1 Each
PURE WATER TANK
800 GALLON,
MANUFACTURED IN ACCORDANCE WITH ATTACHEMENT
(A) SOW SPECIFICATIONS
CERTIFICATIONS REQUIRED PER ATTACHMENT (B)
NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD unique identification or a DoD recognized unique identification equivalent.
Pricing Arrangement: Firm Fixed Price
1 Each
Section C - Description/Specifications/Statement of Work
Extended Description
Clin 0001 -0002 - Extended Description
PURE WATER TANK, (2)
800 GALLON,
MANUFACTURED IN ACCORDANCE WITH ATTACHEMENT (A) SOW SPECIFICATIONS
CERTIFICATIONS REQUIRED PER ATTACHMENT (B)
CERTIFICATE OF COMPLIANCE REQUIRED
MERCURY FREE CLAUSE INVOKED
STATEMENT OF WORK
SPECIFICATION FOR PROCUREMENT OF 800 GALLON PURE WATER TANK
JML REFERENCE: 6022ZN01-ZN02
1. Provide an eight hundred (800) Gallon Stainless Steel low pressure horizontally oriented :SCOPE cylindrical tank with elliptical end caps. Tank assembly will include tank saddle with integral lift lugs (tank & saddle) and fork lift tubes within the saddle base. Tank assembly shall be outfitted with continuous level & temperature indication, along with service connections detailed within this statement of work (inlet, outlet, vent, sample, nitrogen supply, etc.). Overall tank height and dimensions shall allow placement within a standard width and height Conex box/Sealand container.
2. REFERENCES:
2.1 ASME Boiler and Pressure Vessel Code, Section VIII Division 1
2.2 MIL-STD-2041, Control of Detrimental Materials
2.3 MIL-STD-767, Control of Hardware Cleanliness
2.4 ASME Boiler and Pressure Vessel Code, Section II Part A (Material Specification SA-240)
2.5 ASTM A500, Standard Specification for Cold-formed Welded and Seamless Carbon Steel
Structural Tubing in Rounds and Shapes.
2.6 ASTM A36, Standard Specification for Carbon Structural Steel.
2.7 ASTM A240/A240M, Standard Specification for Chromium and Chromium-Nickel
Stainless Steel Plate, Sheet, and Strip for Pressure Vessels.
2.8 ASTM A276/A276M, Standard Specification for Stainless Stee Bars and Shapes
2.9 ASTM A511/A511M, Standard Specification for Seamless Stainless-Steel Mechanical
Tubing and Hollow Bar.
2.10 MIL-PRF-23236, Coating Systems for Ship Structures
2.11 A-A-59326D, Coupling Halves, Quick-Disconnect, Dam-Locking Type, General
Specification Form.
2.12 ASME B16.5 Pipe Flanges and Flange Fittings
2.13 ASTM A312, Standard Specification for Seamless, Welded, and Heavily Cold Worked
Austenitic Stainless-Steel Pipes
2.14 ASME B16.9 Factory-Made Wrought Buttwelding Fittings
2.15 ANSI N14.6-1993, Special Lifting Devices for Shipping Containers Weighing 10000
Pounds (4500 kg) or More.
2.16 NAVSEA Technical Publication T9074-AS-GIB-010/271, Requirements for nondestructive Testing Methods.
2.17 MIL-STD-2035A, Non-Destructive Testing Acceptance Criteria.
2.18 ASTM A967/A967M, Standard Specification for Chemical Passivation Treatments for
Stainless Steel Parts.
2.19 SAE J514, Hydraulic Tube Fittings
2.20 AWS D1.1, Structural Welding Code - Steel
2.21 AWS D1.2, Structural Welding Code - Aluminum
2.22 AWS D1.6, Structural Welding Code - Stainless Steel
2.23 MIL-STD-22, Welded Joint Design
3. GENERAL REQUIREMENTS:
3.1 Where specifications and/or standards are specified or referenced, the latest revision shall be used unless otherwise specified.
3.2 Tank design, fabrication and testing shall be in accordance with reference 2.1. Tank shall be stamped with the code "U" symbol.
3.3 Formal NNSY approval, via signature, of tank assembly drawings, with material list(s), shall be obtained prior to beginning fabrication.
3.4 All internal and/or fluid contacting surfaces/materials of the tank assembly (tank body, end caps, piping, etc.) and its components (e.g., valves, level/temperature transmitter assembly,etc).
shall meet detrimental material and cleanliness requirements of references 2.2 and 2.3.
3.4.1 Interior tank and piping surfaces (i.e., fluid contacting surfaces) shall be cleaned to remove debris, foreign materials, markings, corrosion, weld spatter, paint, preservatives, oils, greases, lubricates, etc. in accordance with requirements of reference 2.3.
3.4.2 All lubricants for component operation (valve, fittings, etc.) or shop assembly shall meet detrimental material requirements of reference 2.2 or be completely removed per 3.4.1.
3.4.3 All Lubricants used for moving parts within valves/fittings/components shall be formally authorized and agreed to, via signature, between NNSY and the vendor.
3.5 All equipment/components furnished shall NOT contain mercury. In addition, equipment/components furnished shall NOT have come into direct contact with mercury or mercury containing components during fabrication or testing.
3.6 Tank shell/body and elliptical end caps shall be stainless steel, Grade 316 (Reference 2.4 or equivalent).
3.7 Tank assembly saddle, lift lugs, base with forklift tubes and framing for process meter enclosure mounting shall be fabricated from carbon steel (references 2.5, 2.6 or equivalent) or grade 304/316 stainless steel (references 2.7, 2.8, 2.9 or equivalent).
3.8 Coating systems (i.e., paints and primers) used on carbon steel structural/framing components shall be non-hazardous per Resource Conservation and Recovery Act (RCRA) requirements.
3.8.1 ( ) shall approve coating system, via signature, prior to Norfolk Naval Shipyard NNSY coating system use/application. Coating systems per reference 2.10 are approved for use.
3.8.2 Prohibited colors are yellow, magenta, purple, gold, red and orange.
3.9 Markings (e.g., weight, lift points, serial numbers, etc.), when referenced to this paragraph, shall be made using 1-inch-tall letters and highly contrasting color paint (e.g., black frame with white lettering). Label plates/placards made using , or equivalentGravotech Gravoply poly/composite material providing high contrast (e.g., black background with white lettering) may be used for marking on stainless steel structures and components.
3.10 The use of cadmium plated components/fittings is prohibited.
3.11 The use of brass/bronze components or fittings is prohibited. Any use of brass/bronze components or fittings shall be formally authorized and agreed to, via signature, between
NNSY and the vendor.
3.12 Teflon tape or any type of thread sealant/locker shall NOT be used on any fluid contacting components (e.g., NPT Joints, etc.) unless formally authorized and agreed to, via signature, between NNSY and the vendor. Loctite 5772 is an authorized thread sealant/locker which may be used on fluid contacting components.
3.13 All Camlock fittings shall be stainless steel and meet requirements of reference 2.11.
Rings and pins on camlock arms shall NOT be cadmium plated.
3.14 All Flanges shall be stainless steel (grade 316), raised face with weld neck ends for connection to piping per reference 2.12.
3.15 All piping assembly end fittings (open end of assembly for connecting temporary equipment/systems) shall be provided with a mechanical cap/blank installed
(i.e., SAE J514 flare cap, blind flange, union blank) as applicable.
3.15.1 All Camlock closure dust caps shall be Dixon Cam and Groove EZ-Link armless dust caps.
Caps shall be installed on all pipe assembly ends containing male Camlock adapters.
3.15.2 All mechanical caps/blanks shall be attached to their respective piping assembly via lanyard (stainless steel braided wire (1/16 - 1/8-inch diameter) and Nico press sleeving).
Flange blanks are not required to be attached via lanyard.
3.16 All piping shall be seamless stainless steel (grade 316) in accordance with reference 2.13.
Minimum pipe schedule allowed is SCH 40.
3.17 All pipe fittings shall be stainless steel (grade 316) butt weld end prep per reference 2.14, unless otherwise specified in this statement of work or authorized by NNSY.
3.18 Valves shall be three-piece stainless steel (grade 316) full port ball valves with butt weld ends. Seats, seals and packing shall be PTFE. All valves shall be Swagelok 60 series or
Bray 7000/8000 series, with locking lever handles, meeting component design pressures.
3.19 TANK ASSEMBLY /OPERATING PRESSURES, FLOWRATES & TEMPERATURE REQUIREMENTS
ARE AS SPECIFIED BELOW:
3.19.1 Design pressure: 30 psig.
3.19.2 Vacuum pressure, design: 29 inches Hg/full vacuum.
3.19.3 Normal operating pressure: 20 psig maximum.
3.19.4 Flowrate via low point suction connections: 60 GPM.
3.19.5 Design temperature is -20 Fahrenheit to 120 Fahrenheit ambient outside air temperature.
Fluid will be at ambient temperature (e.g., typically 50 Fahrenheit or greater with freeze protection).
3.20 Overall tank dimensions shall allow tank to be located within a standard Conex/Sealand container. Dimensions on one end of the tank assembly (height and width) shall allow it to pass through a standard Conex/Sealand container door opening (width - 92 inches, height -89 inches).
3.21 Use of the following during preparation and fabrication of the tank is prohibited.
3.21.1 Oil or other cutting fluids.
3.21.2 Metal removal or finishing tools made of materials which may cross contaminate surfaces or cause surface corrosion staining of stainless-steel surface, when exposed to water or a moist atmosphere.
3.21.3 Power driven tools or wire brushes that tend to smear metal.
3.21.4 Tools or abrasive materials which have previously been used on low alloy steels, aluminum, lead or other low melting point materials.
3.22 All testing requiring liquid supplied to the tank and piping internals shall be performed using deionized water.
3.23 Vendor shall provide NNSY representative(s) the opportunity to perform an inspection of the accessible internal and external surfaces of the tank assembly. NNSY reserves the right to witness fabrication and testing of the tank assembly.
4. TANK ASSEMBLY BASE PLATE, FRAMING & SADDLE:
4.1 Tank assembly, saddle and any support component mounting frames (i.e., process meter enclosure, power box) shall be built on a main assembly base plate/frame.
4.2 Base plate/frame shall be constructed from plate/shaped structural carbon steel (references
2.5, 2.6 or equivalent) of grade 304/316 stainless steel (references 2.7, 2.8, 2.9 or equivalent).
4.3 Base plate/frame/lift lugs shall be coated to prevent corrosion per requirements of paragraph 3.8. This requirement is not applicable to stainless steel plate/frame/lift lug materials.
4.4 Base plate/frame shall be outfitted with forklift tubes which run in both directions (length and width of base) to allow movement of the assembly via forklift from all sides
4.5 Base plate/frame shall be sized to ensure the tank assembly (all components, piping, valves and saddle with tank at 90% fill volume) shall not create a floor/ground loading which exceeds 400 lbs./ft2. Base plate/frame shall be sized to transit through a standard
Conex/Sealand container door opening width of 92 inches on one end.
4.6 All exterior surfaces of base plate, framing and saddle shall be smooth and all sharp edges rounded/chamfered.
5. TANK ASSEMBLY LIFT LUGS/RIGGING ATTACHMENT POINTS & NON-DESTRUCTIVE TEST
DETAILS:
5.1 Tank assembly shall be outfitted with lift lugs/rigging attachment points to allow entire assembly (tank and base plate/frame) to be lifted via an overhead crane.
5.1.1 Lift lugs/rigging attachment points shall be permanently attached to the base plate/frame or the tank saddle support members.
5.1.2 Lift lugs/rigging attachment points shall be oriented to allow use of a single overhead crane attachment point or a spreader beam.
5.2 Integral lift lugs/rigging attachment points shall meet the requirements of reference 2.15.
5.3 Vendor shall provide certification and results of the drop weight test per ASTM E208 or a
Charpy Impact test per ASTM A370. The anticipated minimum service temperature for the tank assembly and integral lift lugs/rigging attachment points is 20 Fahrenheit.
5.4 Lift lugs/rigging attachment points and load-bearing members shall be capable of supporting a load three times the combined weight of the empty tank assembly (3:1 yield), without generating a combined shear stress or maximum tensile stress at any point in the device exceeding the corresponding minimum tensile yield strength of the materials of construction.
5.5 Lift lugs/rigging attachment points and load-bearing members shall also be capable of lifting five times the weight of the empty tank assembly (5:1 ultimate) without exceeding the ultimate tensile strength of the materials of construction.
5.6 Load Testing and Non-Destructive Testing (NDT) of the lift lugs/rigging attachment points.
5.6.1 Vendor shall perform pre and post load test visual inspection of the lift lugs/rigging attachment points; no signs of cracked, broken, worn, distorted, corroded, deteriorated, binding or lose parts are allowed.
5.6.2 Vendor shall perform pre and post load test magnetic particle or liquid penetrant (stainless steel materials) inspections of the entire lift lugs/rigging attachment points and attachment welds. Magnetic particle or liquid penetrant inspections shall be performed in accordance with reference 2.16 with acceptance criteria per reference 2.17 (Class 3 or equivalent for welds). Certified report required.
5.6.3 Vendor shall perform a load test of the integral lift lugs/rigging attachment points. Test load shall be performed at 150% (+5/-0%) of the maximum service load. Maximum service load for this application is the weight of the empty tank assembly. Load test shall be held for a minimum of 10 minutes. Certified report required.
5.7 Vendor shall provide a lifting/rigging diagram detailing the preferred configuration (sling lengths, angles, minimum pendent/component capacity, etc.).
6. TANK DETAILS:
6.1 Tank shall be an eight hundred (800) gallon nominal capacity horizontal cylindrical tank with elliptical end caps.
6.2 Tank shell, including elliptical end caps shall be stainless steel (grade 304/316) per reference 2.4, or an equivalent stainless steel plate specification. Minimum acceptable plate thickness for the shell and elliptical end caps is 5/16 inch. Plate with a No. 4 or finer finish, for use on the inside tank surface, shall be used to facilitate obtaining the required interior surface roughness/finish of paragraph 6.3.
6.3 Interior tank surface (including piping and components) shall have a surface roughness/finish of 32 Ra or better. All pits, gouges, scratches, tool marks, weld spatter, etc., shall be fired into the surrounding surface.
6.4 Interior tank weld surface(s) (including piping and components) shall have a roughness/finish of 32 Ra or better. Welds shall be free of undercut and shall not snag and/or tear a cleaning cloth when wiped in any direction.
6.5 A GAR S-22 micro finish comparator surface roughness scale (GAR Electroforming
Division Danbur, CT) or similar comparator shall be usedwww.garelectroforming.com to verify interior tank and weld surface finish.
6.6 Tank shall have a personnel access for tank entry which is a minimum of 18 inches in diameter. Closure seal shall utilize a Buna-N gasket. Use of cork-rubber gaskets is prohibited.
6.7 Interior and exterior of the tank shell and elliptical end caps shall be free of embedded ferrous or aluminum particles resulting from rolling and/or forming. Rollers and/or forming equipment used exclusively on stainless steel should be used to form the tank.
6.7.1 Rollers or other forming machines that have been used on ferrous or aluminum metals may be used to form the tank shell and end caps provided special precautions are taken to ensure a satisfactory barrier is located between the rollers/forming machines and the tank shell or elliptical end cap materials.
6.7.2 The contractor shall submit a written request to NNSY for use of rollers or other forming machines discussed in paragraph 6.7.1 and obtain/receive written approval from NNSY.
Request shall specify why use of the paragraph 6.7.1 equipment is required and provide details of the special precautions which will be in place ensuring contact between the tank shell/elliptical end cap material and the rollers/forming equipment does not occur.
6.8 Tank shell and elliptical end cap base materials and weld areas (prior to and after completion of welding) shall be passivated per reference 2.18, or other equivalent specification. Solutions and passivation process shall maintain compliance with requirements of references 2.2 and 2.3. Certified report required.
7. PIPING ASSEMBLIES AND CONNECTION DETAILS:
7.1 Tank shall contain two (2) drain/suction piping assemblies connected to tank via bottom connections/penetrations and terminate with end caps on the same tank end.
7.1.1 Piping assemblies shall be 1 1/2-inch SCH 40 per paragraph 3.16.
7.1.2 Piping assemblies shall have a 1 1/2-inch full port ball valve, per paragraph 3.18, between tank penetration/connection and end fitting.
7.1.3 Process connection end fitting shall be a 1 1/2 inch male camlock per paragraph 3.13.
Fitting shall be provided with an end cap closure per paragraph 3.15.
7.1.4 Each penetration (inlet to discharge piping assembly inside tank) shall have a vortex break installed.
7.1.5 One piping assembly tank penetration shall be on longitudinal centerline of tank bottom and the other shall be slightly off centerline and parallel with the other assembly (see figure 1). See figure 2 for general piping assembly arrangement.
7.2 Tank shall contain a single piping assembly for obtaining liquid samples, connected to tank via bottom connection/penetration and terminate with end cap at same tank end as paragraph 7.1 piping assemblies (see figure 1). See figure 2 for general piping assembly arrangement.
7.2.1 Piping assembly shall be 3/8-inch SCH 40 per paragraph 3.16.
7.2.2 Piping assembly shall have a 3/8-inch full port ball valve, per paragraph 3.18, between tanks penetration/connection and end fitting.
7.2.3 Process connection end fitting shall be a 3/8-inch 37-degree flare fitting per reference 2.19
(i.e., SSP PN BM6-6J or equivalent). Fitting shall be provided with an end cap closure per paragraph 3.15 (i.e., SSP PN AS6Z-2 or equivalent).
7.2.4 Tank penetration shall be slightly off centerline of tank bottom longitudinal; piping assembly shall also parallel assemblies of paragraph 7.1 (see figure 1). See figure 2 for general piping assembly arrangement.
PLEASE SEE ATTACHED STATEMENT OF WORK TO VIEW:
FIGURE (1): DRAIN/ SUCTION AND SAMPLE LINE ARRANGEMENT, VIEWED FROM TANK END
FIGURE (2): GENERAL PIPING ASSEMBLY ARRANGEMENT FOR DRAIN/ SUCTION AND SAMPLE LINE
DRAIN/SUCTION ASSEMBLIES
7.3 Tank shall contain a single fill line assembly connected to tank via top connection/penetration and terminate with end cap on the same tank end (See figure 3).
See figure 4 for general piping assembly arrangement
7.3.1 Fill assembly shall be located at the tank end opposite the piping assemblies of paragraphs
7.1 and 7.2.
7.3.2 Piping assembly shall be 2-inch SCH 40 per paragraph 3.16.
7.3.3 Piping assembly shall have a 2 inch full port ball valve, per paragraph 3.18, between tank penetration/connection and end fitting.
7.3.4 Process connection end fitting shall be a 2 inch male camlock x buttweld, per paragraph
3.13. Piping assembly shall be supplied with an end cap closure fitting per paragraph 3.15.
7.3.5 Piping assembly shall maintain a constant downward slope from piping assembly camlock connection to tank top penetration.
7.3.6 Piping assembly shall be slightly off centerline and parallel with the piping assembly of paragraph 7.4. See figures 3 and 4 for piping assembly arrangement details.
7.4 Tank shall contain a single piping assembly for discharge receipt from a relief valve.;
connected to tank via top connection/penetration and terminate with end cap at same tank end as the paragraph 7.3 piping assembly (see figure 3). See figure 4 for general piping assembly arrangement.
7.4.1 Piping shall be 1 inch SCH 40 per paragraph 3.16.
7.4.2 Piping assembly shall have a 1 inch full port ball valve, per paragraph 3.18, between tank penetration/connection and end fitting.
7.4.3 Process connection end fitting shall be a 1 inch 37 degree flare fitting per reference 2.19
(i.e., SSP PN BM16-16J or equivalent). Fitting shall be provided with an end cap closure per paragraph 3.15 (i.e., SS PN AS16Z-2 or equivalent).
7.4.4 Piping assembly shall maintain a constant downward slope from piping assembly 37 degree flare connection to tank top penetration.
7.4.5 Piping assembly shall be slightly off centerline and parallel with piping assembly of paragraph 7.3.
PLEASE SEE ATTACHED STATEMENT OF WORK TO VIEW
FIGURE (3) FILL AND RELIEF VALVE DISCHARGE RECEIPT LINES, VEIWING FROM TANK END
FIGURE (4) GENERAL PIPING ASSEMBLY ARRANGEMENT FOR FILL AND RELIEF VALVE
DISCHARGE RECEIPTS LINES.
7.5 Tank shall contain a single piping assembly connected via tank top connection/penetration for a nitrogen supply and installation/connection of a make-up air assembly. See figure 5 for piping assembly arrangement.
7.5.1 Piping for nitrogen supply shall be 1 inch SCH 40, per paragraph 3.16.
7.5.2 Piping for nitrogen supply shall have a 1-inch full port ball valve per paragraph 3.18, between tank penetration/connection and end fitting.
7.5.3 Piping for make-up air assembly shall be 1 inch SCH 40, minimum, per paragraph 3.16.
Piping shall be sized to ensure that negative pressure/vacuum condition is not created during liquid removal from tank at 60 GPM.
7.5.4 Piping assembly end fittings shall be a 150 Class raised face flange per paragraph 3.14.
Tank assembly shall be supplied with a blank flange closure fitting per paragraph 3.15.
Temporary closure gasket for storage/shipping shall be Buna-N.
PLEASE SEE ATTACHED STATEMENT OF WORK TO VIEW
FIGURE (5): NITROGEN SUPPLY AND MAKE UP AIR PIPING ASSEMBLY ARRANGEMENT
7.6 Tank shall contain a single piping assembly connected via tank top connection/penetration for installation/connection of a relief valve assembly. See figure 6 for piping assembly arrangement.
7.6.1 Piping assembly shall be 1 inch SCH 40 per paragraph 3.16.
7.6.2 Piping assembly end fitting shall be a 150 Class raised face flange per paragraph 3.14.
piping assembly shall be supplied with a blank flange closure fitting per paragraph 3.15.
Temporary closure gasket for storage/shipping shall be Buna-N.
PLEASE SEE ATTACHED STATEMENT OF WORK TO VIEW
FIGURE (6): RELIEF VALVE PIPING ASSEMBLY ARRANGEMENT
7.7 Tank shall contain a single piping assembly connected via tank top penetration for venting the tank to atmospheric pressure supporting, filling, draining and pump down operations.
7.7.1 Vent assembly shall be located at the tank end opposite the fill assembly of paragraph 7.3.
7.7.2 Vent assembly shall be 2 inch SCH 40 per paragraph 3.16.
7.7.3 Vent assembly piping end open to atmosphere shall terminate in a downward facing direction (see figure 7).
7.7.4 A stainless steel (Grade 316) 75-micron screen shall be welded to the vent piping end open to atmosphere (alternate methods to secure mesh screen in place may be proposed in contractors drawing submitted for NNSY approval per paragraph 3.3.).
7.7.5 Vent assembly shall have a 2 inch full port ball valve, per paragraph 3.18, between tank penetration/connection and the piping end open to atmosphere.
PLEASE SEE ATTACHED STATEMENT OF WORK TO VIEW
FIGURE (7): TANK VENT PIPING ASSEMBLY ARRANGEMENT
7.8 Tank shall contain a single piping assembly connected via tank top penetration for monitoring tank internal pressure. Piping assembly shall be outfitted with a compound gauge assembly (see figure 8).
7.8.1 Piping assembly shall be 3/8 inch SCH 40 per paragraph 3.16.
7.8.2 Piping assembly shall have a 3/8-inch full port ball valve, per paragraph 3.18 between tanks penetration/connection and the gauge assembly.
7.8.3 Gage assembly shall be a compound type (e.g. capable of indicating vacuum/suction pressure) with a digital pressure display (Ametek/Crystal Engineering XP2I 0-100 psi;
VPN 100PSIXP2I or equivalent).
PLEASE SEE ATTACHED STATEMENT OF WORK TO VIEW
FIGURE (8): TANK VENT PIPING ASSEMBLY ARRANGEMENT
8 MONITORING EQUIPTMENT
8.1 Tank shall be outfitted with a Temposonics/MTS Level Plus (MR Model) or Refine ME
(LPR Model) analog liquid level/volume sensor/transmitter with resistance temperature detector located 16 inches from bottom of sensor assembly. Assembly shall utilize a rigid stainless steel probe with welded flange mounting and a 3/4" NPT conduit/cabling connection. All wetted parts of the sensing element shall be grade 304/316 stainless steel.
8.2 Liquid level float shall be a Temposonics/MTS float (Model 201248-2, or equivalent), constructed from grade 316/304 stainless steel having a magnet located at the top of the float to allow level indication at lowest level possible.
8.3 Tank volume/liquid level process meter shall be a Precision Digital (Model PD6000-6R5 with red display).
8.4 Tank effluent temperature process meter shall be a Precision Digital (Model PD6000-6R0 with red display).
Temperature range for RTD is 20 Fahrenheit - 240 Fahrenheit.
8.5 Process meters shall be contained/mounted within a Hoffman (Model CSD242410W) concept enclosure with a NEMA 4 rating. Enclosure shall have include a concept panel
(Hoffman CP2424) and a concept swing-out panel (CSP2424). Enclosure shall contain the process meters of paragraphs 8.3 and 8.4. Enclosure shall be mounted to the tank assembly via a separate free standing frame integral with the base plate our it can be mounted to the elliptical end cap where the discharge and sample connections are located.
Alternate NEMA 4 rated enclosures are acceptable with NNSY approval of drawing per paragraph 3.3.
8.6 Main power to process meters, liquid level sensor and temperature detector shall be via a disconnect safety switch (120V AC, NEMA 4X enclosure) with associated power cord
(8 ft long) outfitted with a twist lock plug end.
9 WELDING DETAILS:
9.1 Welding (tank shell and end caps, tank piping penetrations and any welded attachments to end caps/shell) shall be in accordance with the requirements of reference 2.1.
9.2 Longitudinal and circumferential welds to assemble the tank shell and circumferential joints between the shell and elliptical end caps shall be full penetration welds, welded from the outside and inside. Welds shall be back gouged to sound metal, and all slag removed prior to welding from second side.
9.3 Weld surfaces on interior of tank shell (including exterior welds on any piping internal to the tank) shall be ground flush and be free of weld spatter, scratches, burrs, rust and slag.
Surface shall not snag or tear a cleaning cloth when wiped in any direction. Edges of welds shall be smoothy blended with base metal.
9.4 Welds (tank shell, end caps and any welded attachments to end caps/shell) shall be liquid penetrant inspected, at a minimum, per requirements of reference 2.1. Certification report required.
9.5 All structural welding shall be in accordance with references 2.20, 2.21 and 2.22 as appropriate.
9.6 All piping/pipe fitting welds shall be full penetration butt weld joints (i.e., use of consumable inserts allowed), per reference 2.23 or equivalent standard/specification.
9.7 All pipe to tank shell welds shall be full penetration welds.
9.8 All burrs and weld spatter shall be removed from all exterior tank and frame welds. All rough edges shall be rounded or removed.
9.9 Vendor shall certify that any/all weld spatter and slag has been removed and that the tank assembly internal and external surfaces a free of weld spatter and slag. No weld spatter or slag shall be present on tank assembly internal or external surfaces.
10 TANK ASSEMBLY TESTING DETAILS:
10.1 Vendor shall hydrostatically pressure test the tank assembly to 33 +2/-0 psig (test boundary shall include all piping assemblies, valves and personnel access/manway). Test pressure shall be held for 30 minutes (no leaks, damage or permanent deformation allowed). Tank assembly shall have completed all non-destructive testing and shall be secured in its saddle with base plate assembly during testing. Certified report required.
10.2 Vendor shall perform a calibrated fill of the tank to 90% fill volume (see paragraph 3.22).
Level data (gallons) shall be recorded for each 1 inch change in level height. Level data shall be provided to NNSY. Certified report required.
10.3 Vendor shall perform level checks of the tank assembly utilizing the analog liquid level/volume sensor/transmitter of paragraph 8.1 to validate accurate operation of the sensor/transmitter and associated process meter of paragraph 8.3. Certified report required.
10.4 Vendor shall perform an operational check/test to validate operation and accuracy of the resistance temperature detector of paragraph 8.1 and its associated process meter of paragraph 8.4. Certified report required.
10.5 After completion of hydrostatic testing and level checks, the tank and piping assembly internals shall be dried by wiping and/or by blowing dry filtered air/nitrogen through internals. Certified report required.
10.6 Weigh entire tank assembly empty and filled to 90% capacity (tank with all piping assemblies attached and secured in its saddle with base plate assembly). Load indicating device shall be calibrated within +/- 2% of the devices full scale. Certified report required.
11 :TANK ASSEMBLY MARKING REQUIREMENT
11.1 Tank assembly shall be marked in two locations on its saddle with base plate/frame.
Marking shall provide the following information as a minimum. Markings shall be made per details of paragraph 3.9.
11.1.1 Purchase Order Number
11.1.2 Tank Serial Number; RDPWT-1, RDPWT-2, etc.
11.2 Process meters shall be labeled using solid label plates (black background with white lettering).
Label plates shall be made from a hard composite material (phenolic, poly, gravoply, etc.).
11.2.1 Liquid level process meter shall have a label plate stating, "Liquid Level (Gallons)".
11.2.2 Temperature process meter shall have a label plate stating, "Temperature (Degrees
Fahrenheit)".
11.3 Tank assembly shall have a label plate attached to shell (one location). Label plate backing shall be constructed from stainless steel/aluminum with black block style lettering. Label plate shall contain the following information.
11.3.1 Design Pressure: 30 psig
11.3.2 Design Temperature: 120 F
11.3.3 Hydro Test Pressure: 33 +2/-0 psig
11.3.4 Hydo Test Date: __-__-____
11.3.5 Full Tank Capacity: _________Gallons
11.3.6 Empty Weight: __________Pounds
11.3.7 Full Weight: ____________Pounds
11.4 Lifting attachment points shall be marked per paragraph 3.9 with the following verbiage, "LIFT POINT".
12 VENDORS SHALL PROVIDE THE FOLLOWING CERTIFICATION OF COMPLIANCE, INSPECTION
/TEST REPORTS AND ADDITIONAL INFORMATION:
12.1 Certification of Compliance.
12.2 Inspection/Test Reports.
12.2.1 Mercury exclusion certification (see paragraph 3.5).
12.2.2 Drop Weight Test (ASTM E208) or a Charpy Impact test (ASTM A370) results/reports for integral lift lugs/rigging attachment points (see paragraph 5.3).
12.2.3 Pre and post load test magnetic particle or liquid penetrant inspection reports (see paragraph 5.6.2).
12.2.4 Lift lug/rigging attachment load test report (see paragraph 5.6.3).
12.2.5 Liquid penetrant inspection reports for tank welds (see paragraph 9.4).
12.2.6 Certify that no weld spatter or slag is present on tank internal/external surfaces (see paragraph 9.9).
12.2.7 Hydrostatic test of tank assembly (see paragraph 10.1).
12.2.8 Calibrated fill of tank to 90% fill volume (see paragraph 10.2).
12.2.9 Tank level check using analog liquid level/volume sensor/transmitter and process meter (see paragraph 10.3).
12.2.10 Operational check of resistance temperature detector and process meter (see paragraph 10.4).
12.2.11 Certify tank internals fully dried after testing (see paragraph 10.5).
12.2.12 Certify weight of entire tank assembly empty and filled to 90% capacity (see paragraph 10.6).
12.2.13 All fluid contacting components/materials meet detrimental material and cleanliness requirements of references 2.2 and 2.3 (see paragraph 3.4).
12.2.14 All lubricants used on fluid contacting components shall meet detrimental material requirements of reference 2.2. Any factory lubricants that do not meet detrimental material requirements of refence 2.2 have been removed, surfaces cleaned per requirements of reference 2.3 and lubricants replaced with one which is compliant with reference 2.2 (see paragraph 3.4).
12.2.15 Certify tank shell and elliptical end cap base materials and weld areas are passivated (see paragraph 6.8).
12.3 Additional information.
12.3.1 Operating and maintenance manual for liquid level sensor/transmitter, resistance temperature detector and process meters.
12.3.2 Rigging diagram for lifting tank assembly using and overhead crane (see paragraph 5.7).
12.3.3 Tank assembly drawing with material list (see paragraph 3.3).
12.3.4 List of lubricants (brand name information) utilized for final assembly (i.e., inside ball valves, etc.) along with associated Safety Data Sheets (SDS) and material specifications.
Requirements Pure Water Tanks
Additional Regulation or Supplemental Clauses Incorporated by Full Text
C-202-H001 ADDITIONAL DEFINITIONS--BASIC (Oct 2018)
(a) Department means the Department of the Navy.
(b) Commander, Naval Sea Systems Command means the Commander of the Naval Sea Systems Command of the Department of the Navy or his duly appointed successor.
(c) References to The Federal Acquisition Regulation (FAR) All references to the FAR in this contract shall be deemed to also reference the appropriate sections of the Defense FAR Supplement (DFARS), unless clearly indicated otherwise.
(d) National Stock Numbers Whenever the term Federal Item Identification Number and its acronym FIIN or the term Federal Stock Number and its acronym FSN appear in the contract, order or their cited specifications and standards, the terms and acronyms shall be interpreted as National Item Identification Number (NIIN) and National Stock Number (NSN) respectively which shall be defined as follows:
(1) . The number assigned to each approved Item Identification under the National Item Identification Number (NIIN) Federal Cataloging Program. It consists of nine numeric characters, the first two of which are the National Codification Bureau (NCB) Code. The remaining positions consist of a seven digit nonsignificant number.
(2) . The National Stock Number (NSN) for an item of supply consists of the applicable National Stock Number (NSN) four-position Federal Supply Class (FSC) plus the applicable nine-position NIIN assigned to the item of supply.
(Endof Text)
C-204-H001 USE OF NAVY SUPPORT CONTRACTORS FOR OFFICIAL CONTRACT FILES (Oct 2018)
(a) NAVSEA may use a file room management support contractor, hereinafter referred to as "the support contractor", to manage its file room, in which all official contract files, including the official file supporting this procurement, are retained. These official files may contain information that is considered a trade secret, proprietary, business sensitive or otherwise protected pursuant to law or regulation, hereinafter referred to as "protected information". File room management services consist of any of the following: secretarial or clerical support; data entry; document reproduction, scanning, imaging, or destruction; operation, management, or maintenance of paper-based or electronic mail rooms, file rooms, or libraries; and supervision in connection with functions listed herein.
(b) The cognizant Contracting Officer will ensure that any NAVSEA contract under which these file room management services are acquired will contain a requirement that:
(1) The support contractor not disclose any information;
(2) Individual employees are to be instructed by the support contractor regarding the sensitivity of the official contract files;
(3) The support contractor performing these services be barred from providing any other supplies and/or services, or competing to do so, to NAVSEA for the period of performance of its contract and for an additional three years thereafter unless otherwise provided by law or regulation; and,
(4) In addition to any other rights the contractor may have, it is a third party beneficiary who has the right of direct action against the support contractor, or any person to whom the support contractor has released or disclosed protected information, for the unauthorized duplication, release, or disclosure of such protected information.
(c) Execution of this contract by the contractor is considered consent to NAVSEA's permitting access to any information, irrespective of restrictive markings or the nature of the information submitted, by its file room management support contractor for the limited purpose of executing its file room support contract responsibilities.
(d) NAVSEA may, without further notice, enter into contracts with other contractors for these services. Contractors should enter into separate non-disclosure agreements with the file room contractor. Contact the Procuring Contracting Officer for contractor specifics. However, any such agreement will not be considered a prerequisite before information submitted is stored in the file room or otherwise encumber the government.
(End of Text)
C-209-H001 FIRST ARTICLE (CONTRACTOR TESTING) (NAVSEA) (APR 2024) (Apr 2024)
(a) The First Article shall conform in every respect to the requirements of this contract. The First Article shall be manufactured with tools, materials, and methods which are the same as the tools, material and methods which will be used to manufacture the production units. All items delivered under the contract shall be manufactured under the same conditions and quality established by the First Article. Any changes to tools, material, or methods after the first article approval shall be documented by the contractor and approved by the Contracting Officer before they are used.
(b) The Contractor shall make a record of all data obtained during such tests in a form similar to the guidance provided in MIL-HDBK-831A dated 25 June 2013.
(c) Pursuant to paragraph (e) of the clause entitled "First Article Approval--Contractor Testing" (FAR 52.209- 3), the First Article shall not be delivered as part of the production quantity.
(End of Text)
C-211-H018 APPROVAL BY THE GOVERNMENT (NAVSEA) (JAN 2019) (Jan 2019)
Approval by the Government as required under this contract and applicable specifications shall not relieve the Contractor of its obligation to comply with the specifications and with all other requirements of the contract, nor shall it impose upon the Government any liability it would not have had in the absence of such approval.
(End of Text)
C-223-H003 EXCLUSION OF MERCURY (NAVSEA) (MAR 2019) (Mar 2019)
(a) Definitions. As used in this text:
Article means a manufactured item other than a fluid or particle: (i) which is formed to a specific shape or design during manufacture; (ii) which has end use function(s) dependent in whole or in part upon its shape or design during end use; and
(iii) which under normal conditions of use does not release more than very small quantities, e.g., minute or trace amounts of a hazardous chemical, and does not pose a physical hazard or health risk to employees.
Boundary of containment means a continuous tight seal (barrier) to prevent the release of functional mercury during normal operation and maintenance. Examples include the exterior of a fluorescent lamp, glass capsule of a mercury switch, and container for mercury reagents. A double boundary of containment consists of two independent seals.
Functional mercury means mercury or mercury compound(s) contained in equipment that is required for the equipment to operate properly, such as that found in mercury switches, fluorescent lamps, flat-panel monitors, thermostats, thermostat probes, small coin type batteries, barometers, and dental amalgams.
Hardware means any article, container, piece of material, individual part, subassembly, assembly, component, or system to which mercury control requirements apply.
Mercury-free means hardware that does not contain functional mercury and is not contaminated by mercury or mercury compounds.
Portable means items that are frequently transported during normal operation. Desk lamps, shop lights, and hand-held instruments are considered portable, while bulbs in stationary light fixtures are not. In general, items that require transport only during maintenance, installation, and removal of the items are not considered portable.
(b) The Contractor, and all subcontractors and vendors, shall ensure that mercury or mercury containing compounds are not intentionally added to, or come in direct contact with, hardware or supplies furnished under this contract.
(1) The Contractor shall ensure that mercury and mercury compounds are not taken onboard naval vessels by Contractor, subcontractor, or vendor personnel except for functional mercury used in batteries, dental amalgams, fluorescent lamps, flat-panel monitors, required instruments, sensors or controls, weapon systems, and chemical analysis reagents specified by the Naval Sea Systems Command (NAVSEA).
(2) Portable fluorescent lamps and portable instruments containing elemental mercury must be shock-proof in accordance with MIL-DTL-901E entitled Requirements for Shock Tests, H.I. (High Impact) Shipboard Machinery, Equipment, and Systems and have mercury enclosed by a double boundary of containment. Some devices with liquid crystal display (LCD) screens utilize a fluorescent bulb backlight to illuminate the LCD screen. No additional restrictions or controls apply to devices with LCD screens; however, the Contractor shall remove the LCD screen and seal it in plastic following any evidence that the backlight failed.
(3) For Submarines, any use of mercury containing items must be approved as required by the Nuclear Powered Submarine Atmosphere Control Manual (S9510-AB-ATM-010/U) Volume 1.
(4) The Contractor shall ensure that mercury and mercury compounds do not contact hardware surfaces in systems covered by NAVSEA Manual NAVSEA 0989-064-3000 entitled Cleanliness Requirements for Nuclear Propulsion Plant Maintenance and Construction, submarine air systems, level I systems per NAVSEA Publication 0948-LP-045-7010, NAVSEA Material Control Standard, or the submarine safety program (SUBSAFE) surfaces during maintenance or repair.
Such hardware is designated as mercury-free. The Contractor shall ensure that all other hardware that could be structurally degraded by contamination with elemental mercury or reactive mercury compounds is separated from it by sufficient distance, or boundaries of containment that effectively prevents contact in all but the most extreme circumstances.
(5) The Contractor shall check any hardware surfaces in the above systems which are known or suspected to have come in contact with mercury or mercury compounds for evidence of structural degradation and external mercury contamination.
The existence of external mercury contamination can be determined following MIL-STD-2041D entitled Control of Detrimental Materials.
(6) The presence of mercury in a product may be determined by checking product labeling on material safety data sheets or safety data sheets. Chemical analysis is not required.
(7) The Contractor shall dispose of any mercury and mercury compounds in accordance with OPNAV Manual (OPNAV M- 5090.1) entitled Environmental Readiness Program Manual of 10 January 2014.
(8) If the use of mercury or mercury compounds cannot be avoided, a risk assessment and waiver request, if required, must be performed and submitted per the NAVSEA Hazardous Material Avoidance Process (T9070-AL-DPC-020/077-2). For systems covered by the NAVSEA Manual NAVSEA 0989-064-3000 entitled Cleanliness Requirements for Nuclear Propulsion Plant Maintenance and Construction, submit the risk assessment and waiver request, if required to Nuclear Propulsion (NAVSEA 08).
(c) In all cases where mercury or a mercury compound has contacted hardware surfaces required to be mercury-free the Contractor shall immediately provide a report to the NAVSEA Dry Environmental Systems and Hazardous Materials (NAVSEA 05P5) via the cognizant contract administration safety office. Reports concerning systems covered by NAVSEA Manual 0989- 064-3000 must include NAVSEA Nuclear Propulsion Directorate (SEA 08) in the distribution. Reports must be in letter form and include the date and details of the contact, the surfaces contacted, the recovery actions taken, and the status of the affected surfaces.
(End of Text)
Section D - Packaging and Marking
Additional Regulation or Supplemental Clauses Incorporated by Full Text
D-247-H002 PACKAGING OF SUPPLIES—BASIC (NAVSEA) (DEC 2020) (Dec 2020)
Item(s) The supplies furnished hereunder shall be packaged in accordance with ASTM-D-3951-18, Standard Practice for Commercial Packing.0001
(End of Text)
Section E - Inspection and Acceptance
FAR Clauses Incorporated by Reference
Number Title Effective Date
Alternate/ Deviation
Variation Effective Date
52.246-1 Contractor Inspection Requirements. Apr 1984
Overall Contract Inspection/Acceptance Locations
Inspection and Acceptance Location
Both Destination Instructions: Please contact Receiving Officer for delivery information.
DoDAAC: N42158 CountryCode: USA
NORFOLK NAVAL SHIPYARD GF
1 NORFOLK NAVAL SHIPYARD, BUILDING 276
PORTSMOUTH, VA 23709-1001
UNITED STATES
David Love, Technical Engineer - Receiving Officer Email: david.m.love5.civ@us.navy.mil Telephone: 757-396-3061
Inspection and Acceptance Location
Both Destination Instructions: Please contact the Receiving Officer, and or Alternate Receiving Officer JARRAD TAYLOR (808-473-8000 EXT. 4878) if you have any questions or concerns pertaining to delivery.
DoDAAC: N32253 CountryCode: USA
PEARL HARBOR NAVAL SHIPYARD IMF
667 SAFEGUARD STREET, BLDG 167-1 RECV 808-473-8000X4961
PEARL HARBOR, HI 96860-5033
UNITED STATES
Shordon Lopes, Technical Engineer - Receiving Officer Email: shordon.k.lopes.civ@us.navy.mil Telephone: 808-754-9134
Section F - Deliveries or Performance
REQUIREMENTS FOR ACCESS TO NNSY
Commander, Navy Installations Command (CNIC), has established the Defense Biometric Identification System, (DBIDS), a standardized process for granting unescorted access privileges to vendors, contractors, suppliers and service providers not otherwise entitled to the issuance of a Common Access Card (CAC) who seek access to and can provide justification to enter Navy installations and facilities. Participation in the DBIDS is not mandatory, and if the Contractor chooses to not participate, the Contractor's personnel will have to obtain daily passes, be subject to daily mandatory vehicle inspection and will have limited access to the installation. The Government will not be responsible for any cost or lost time associated with obtaining daily passes or added vehicle inspections incurred by non-participants in the DBIDS.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .