SO-1842 Sexton HS Elevator Replacement Addendum 1.pdf
PDF 657 KB Posted
- Attached to
- SO-1842 Sexton HS Elevator Replacement
- Solicitation number
- RFP-LSD-260000000068-3
- Issued by
- Ingham County, Michigan
About this file
This document is Addendum No. 2 for the Lansing School District's J.W. Sexton High School Elevator Replacement project, issued by Matrix Consulting Engineers on 10/27/2025. The addendum provides clarifications for the ongoing elevator replacement project, including details about the concrete pit floor thickness, elevator entrance door specifications, and hazardous materials. The document indicates that bidders should provide a bid based on a 6" floor thickness and submit a unit cost for each additional 2" of floor, and that a new detail (Detail 2/A1.2) will be added to Sheet A1.2 to apply to all elevator entrance doors on all floors.
The addendum includes a sign-in sheet from a pre-bid conference, suggesting that potential contractors have already met to discuss project details. An AHERA book is available at the school for review, which likely contains information about asbestos-related materials. The project appears to involve significant modifications to the existing elevator infrastructure, including new hollow metal elevator door entrance frames, temporary door opening enlargement, and surface treatments like a new 1/4" Corian solid surface. The document is part of the bidding process and provides critical technical clarifications to ensure accurate and comprehensive bid submissions.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1601 E. CÉSAR E. CHÁVEZ AVENUE, LANSING, MI 48906
PHONE: (517) 487-2511
FAX: (517) 487-2544
ADDENDUM NO. 2
Lansing School District
J.W. Sexton High School Elevator Replacement
Date:10/27/2025 Job Number: 24448.01
OWNER: ENGINEER:
Lansing School District Matrix Consulting Engineers 519 W Kalamazoo St 544 Cherbourg Dr Lansing, MI 48933 Lansing, MI 48906
This Addendum is issued for the purpose of modifying and/or clarifying the original Contract Documents and shall take precedence over them.
All work included herein shall be in accordance with the original drawings and specifications except as specifically noted herein. All incidental items required to provide the following modifications shall be included even though not specifically described.
This addendum is being sent to all bidders receiving plans and specifications. Receipt of this Addendum shall be noted on the Proposal Form in the appropriate location.
Pre-Bid Conference
1. Sign-In Sheet
a. See attached sign-in sheet from the Pre-Bid Conference.
Clarifications
1. Concrete Pit Floor Thickness
a. Floor Thickness is unknown. Provide bid based on 6” floor.
b. Provide unit cost for each additional 2” of floor.
2. Door Width
a. Add Detail 2/A1.2 to Sheet A1.2. Detail to apply to all elevator entrance doors on all floors.
3. Hazardous Materials
a. A copy of the AHERA book is available at the school for review.