SMS ITB 02 BLDG G.pdf
PDF 12 MB Posted
- Attached to
- ITB-24-02Building G and D Access Improvements
- Solicitation number
- S-P15005-00010420
- Issued by
- Jackson County, Cheshire CDP, Oregon
About this file
This document is an Invitation to Bid (ITB) issued by the State of Oregon for the ITB-24-02 Building G and D Access Improvements project. The ITB requests bids for construction services to improve accessibility at two buildings located on the State Capitol Mall. The project involves making building entrance and interior upgrades to enhance compliance with the Americans with Disabilities Act (ADA). Bids are due by 2:00 PM on October 16, 2024, and a mandatory pre-bid conference is scheduled for September 25, 2024. The anticipated contract term is 12 months with the possibility of two 12-month renewal periods.
The ITB provides detailed specifications and requirements for the construction work, including item quantities, site access, and project schedules. Pricing is to be submitted using a detailed bid schedule, and the contract will be awarded to the lowest responsive and responsible bidder. The project is funded through the State's capital construction budget, and bidders must meet Oregon's Prevailing Wage requirements. There is no incumbent contractor, and the ITB does not indicate any specific set-aside requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INDICATES DIRECTION & POINT
WHERE SECTION IS TAKEN
INDICATES DRAWING
NUMBER, NAME & SCALE
DRAWING TITLE
COLUMN GRID LINE DESIGNATION
COLUMN GRID SYMBOL
SEE DOOR SCHEDULE
DOOR TAG
SEE FLOOR PLANS
ROOM NAME/NUMBER SYMBOL
REVISION CLOUD
'DELTA' OCCURS AT
EACH CHANGE
REVISION NUMBER
REFER TO INDICATED DRAWING
DETAIL REFERENCE
REFER TO INDICATED DRAWING
ELEVATION REFERENCE
DOOR NUMBER
REVISED AREA
REVISION NUMBER
GRID NUMBER
ROOM NAME
ROOM NUMBER
DRAWING NUMBER
ROOM NAME
150 SF
ROOM AREA
INDICATES PROJECT NORTH
NORTH ARROW
PROJECT NORTH
TRUE NORTH
TRUE
BUILDING SECTION REFERENCE
(WALL SECTIONS UNFILLED ARROW)
KEYNOTE NUMBER
SEE KEYNOTE LISTING
KEYNOTE SYMBOL
X
X/X
XXXXX
XX
X
X
NORTH WALL FINISH
ROOM NUMBER
ROOM ABBREVIATION
EAST WALL FINISH
SOUTH WALL FINISH
FLOOR FINISH & BASE
CEILING FINISH
WEST WALL FINISH
OCCURS ON FINISH PLAN
FINISH PLAN SYMBOL
OCCURS ON EGRESS PLAN
EGRESS EXIT LIGHT
ILLUMINATED ARROW
BRACKET WALL MOUNT
FLUSH WALL MOUNT
ILLUMINATION DIRECTION
A101
SHEET WHERE SHOWN
LEGEND AND SYMBOLS
10A-AFT
SEE BUILDING ASSEMBLIES
WALL TAG
ASSEMBLY NUMBER
MODIFIERS
STUD SIZE
1t
SEE WINDOW SCHEDULE
WINDOW TAG
WINDOW NUMBER
SEE CURTAIN WALL /
STOREFRONT SCHEDULE
CURTAIN WALL / STOREFRONT TAG CURTAIN WALL /
STOREFRONT NUMBER
1i
1t
1' - 0" AFFSEE REFLECTED CEILING PLAN
CEILING TAG CEILING ASSEMBLY
NUMBER
INSTALLATION HEIGHT
PH1 BLDG A A06.11
SIM
1 View Name
1/8" = 1'-0" SHT REF:A1.01
DETAIL DESIGNATION
SHEET WHERE SHOWN
SIMILAR TO REFERENCE
DRAWING DESIGNATION
SHEET WHERE SHOWN
SIMILAR TO REFERENCE
DRAWING NAME
DRAWING SCALE
PH1 BLDG A A06.11
SIM
DRAWING NUMBER
BLDG. G
PROJECT
LOCATION
S C
A L E
S C
A L E
/2
S C
A L E
/4
S C
A L E
/8
S C
A L E
/3
S C
A L E
/8
O
R W
A rc h it e c tu re T h is d o c u m e n t, a n d t h e i d e a s a n d d e s ig n s i n c o rp o ra te d h e re in a s a n i n s tr u m e n t o f p ro fe s s io n a l s e rv ic e s h a ll re m a in t h e p ro p e rt y o f O
R W
A rc h it e c tu re a n d i s n o t to b e r e p ro d u c e d p u b lis h e d o r u s e d i n w h o le o r in p a rt fo r a n y o th e r p ro je c t o r p u rp o s e w it h o u t th e e x p re s s w ri tt e n a u th o ri z a ti o n o f O
R W
A rc h it e c tu re
PROJECT
DATE
No. Description Date
A
C
BCDEFGHJ
ISSUE
/2
/2
:1
:2
P M G00.01
S C
E N
IC
M
ID
D
L E
S C
H O
O L
G B
L D
G A
C C
E S
S
S c e n ic A v e
C e n tr a l P o in t, O
R
2148.02 G BLDG
9/29/2023
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T
T
IT
L E
S H
E E
T
S H
E E
T I N
D E
X
B
IM
:O
R W
A rc h it e c tu re \2
C e n tr a l P o in t S c h o o l D is tr ic t\ P ro je c t F ile s \0
S M
S M
E P
U p g ra d e
W o rk in g
M A
P :3
W
A
B
L O
T :4
PERMIT SET
SCENIC MIDDLE SCHOOL
G BUILDING ACCESS
GENERAL
CONTRACTOR
ELECTRICAL PLUMBING
STRUCTURAL OWNER
CENTRAL POINT SCHOOL DISTRICT
300 ASH STREET
CENTRAL POINT, OR 97502
CONTACT: SPENCER DAVENPORT
CHIEF PROJECTS OFFICER
PHONE: 541-664-1637
FAX:
EMAIL: SPENCER.DAVENPORT@DISTRICT6.ORG
S+B JAMES CONSTRUCTION
8425 AGATE ROAD
WHITE CITY, OR 97503
CONTACT: CRAIG LANGSETH
PROJECT MANAGER
PHONE: 541-826-5668
FAX:
EMAIL: CRAIGLANGSETH@SBJAMES.COM
INTERFACE ENGINEERING, INC.
100 SW MAIN STREET, SUITE 1600
PORTLAND, OR 97204
CONTACT: CLEO NARANJO
ELECTRICAL ENGINEER
PHONE: 503-382-2724
FAX:
EMAIL: CLEON@INTERFACEENG.COM
ZCS ENGINEERING & ARCHITECTURE
127 NW D STREET
GRANTS PASS, OR 97526
CONTACT: STEPHEN CHASE
LEAD DESIGNER
PHONE: 541-479-3865
FAX:
EMAIL: STEPHENC@ZCSEA.COM
INTERFACE ENGINEERING, INC.
100 SW MAIN STREET, SUITE 1600
PORTLAND, OR 97204
CONTACT: CARRIE HAGLER
PLUMBING ENGINEER
PHONE: 503-382-2643
FAX:
EMAIL: CARRIEH@INTERFACEENG.COM
PROJECT VICINITY& LOCATION MAP
TTB TELEPHONE
TERMINAL
BACKBOARD
TYP TYPICAL
UL UNDERWRITERS
LABORATORY
UNO UNLESS NOTED
OTHERWISE
UTIL UTILITY
VCT VINYL COMPOSITION
TILE
VERT VERTICAL
VEST VESTIBULE
VWC VINYL WALL
COVERING
WBG WALL BUMPER GUARD
WC WATER CLOSET
WD WOOD
WDW WINDOW
WF WIDE FLANGE
WP WATER PROOF
WRGB WEATHER RESISTANT
GYPSUM BOARD
PWP PLASTIC WALL PANEL
RB RUBBER BASE
RD ROOF DRAIN
REF REFRIGERATOR
RM ROOM
RO ROUGH OPENING
RSF RESILIENT SHEET
FLOORING
SEP SEPARATION
SF STOREFRONT
SHTG SHEATHING
SIM SIMILAR
SM SHEET METAL
SMS SHEET METAL
SCREWS
SPECS SPECIFICATIONS
SQFT SQUARE FEET
SS STAINLESS STEEL
STL STEEL
STRUCT STRUCTURAL/STRUCT
URE
TFA THROUGH WALL
FLASHING ASSEMBLY
TH THRESHOLD
TO TOP OF
TS TUBE STEEL
MIN MINIMUM
MISC MISCELLANEOUS
MTL METAL
MW MICROWAVE
MWRGWB MOLD & WATER
RESISTANT GYPSUM
WALL BOARD
NIC NOT IN CONTRACT
OC ON CENTER
OCC OCCUPANCY
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED
CONTRACTOR
INSTALLED
OFOI OWNER FURNISHED
OWNER INSTALLED
OPNG OPENING
OVHG OVERHANG
PC PAINT COLOR
PLAM PLASTIC LAMINATED
PSF POUNDS PER SQUARE
FOOT
PT PAINT
PTW PRESSURE TREATED
WOOD
PWD PLYWOOD
FRP FIBER-REINFORCED
PLASTIC
FRZR FREEZER
FTG FOOTING
GA GYPSUM
ASSOCIATION
GALV GALVANIZED
GB GRAB BAR
GC GENERAL
CONTRACTOR
GWB GYPSUM WALL BOARD
HDR HEADER
HDWD HARDWOOD
HGT HEIGHT
HR HOUR
HVAC HEATING/VENTILATING
/AIR CONDITIONING
HW HOT WATER
INSUL INSULATION
INT INTERIOR
JST JOIST
JTS JOINTS
KS KNEE SPACE
MDL MODEL
MECH MECHANICAL
MFR MANUFACTURER
CW CURTAIN WALL
D-B DESIGN BUILD
DF DRINKING FOUNTAIN
DIA DIAMETER
DIMS DIMENSIONS
DP DISABLED PERSON
DW DISHWASHER
EA EACH
EJ EXPANSION JOINT
ELEC ELECTRICAL
EQ EQUAL(Y)
EX EXISTING
EXT EXTERIOR
FD FLOOR DRAIN
FEC FIRE EXTINGUISHER
CABINET
FF FINISHED FLOOR /
FINISHED FACE
FIN FINISH(ED)
FMG FRAMING
FOM FACE OF MASONRY
FOS FACE OF STUD/
STRUCTURE
FR FIRE RESISTANT
FRM FRAMING
ACT ACOUSTIC CEILING
TILE
ADJ ADJACENT
AFF ABOVE FINISHED
FLOOR
AL ALIGN
ASW AREA SEPARATION
WALL
BLD BUILDING
BM BEAM
BOS BOTTOM OF
STRUCTURE
BS BACKSPLASH
CFCI CONTRACTOR
FURNISHED
CONTRACTOR
INSTALLED
CJ CONTROL JOINT
CLG CEILING
CMU CONCRETE MASONRY
UNIT
CONC CONCRETE
CONF CONFERENCE
CPT CARPET
CTSK COUNTERSUNK
ABBREVIATIONS
MECHANICAL
INTERFACE ENGINEERING, INC.
100 SW MAIN STREET, SUITE 1600
PORTLAND, OR 97204
CONTACT: MIKE MOERLINS
ASSOCIATE PRINCIPAL/SENIOR
MECHANICAL ENGINEER
PHONE: 503-382-2643
FAX:
EMAIL: MICHAELM@INTERFACEENG.COM
ARCHITECT
ORW ARCHITECTURE
29 S. GRAPE ST
MEDFORD, OREGON 97501
ARCHITECT OF RECORD
ANDREW OWEN
ANDREW@ORWARCH.COM
CONTACT: DAVE STEVENS
PROJECT MANAGER
PHONE: 541.779.5237 x13
FAX: 541.772.8472
EMAIL: DSTEVENS@ORWARCH.COM
OWNER
REPRESENTATIVE
OTAK
808 SW THIRD AVENUE, SUITE 800
PORTLAND, OR 97204
CONTACT: MICHELLE KEIZER
PROJECT MANAGER
PHONE: 503-706-1449
FAX: 541-618-9156
EMAIL: MICHELLE.KEIZER@OTAK.COM
SHEET INDEX
ARCHITECTURAL - BLDG G
A00.21 BUILDING ASSEMBLIES & DOOR SCHEDULE
A03.01 FLOOR PLAN/RCP/EGRESS DIAGRAM - LEVEL 1
A04.01 ENL. FLOOR PLAN - NEW HALL & ALTERNATE DOOR OPT. 2
A06.01 SCHEDULES - DOORS
A07.01 EXTERIOR ELEVATIONS, BUILDING & WALL SECTIONS
A11.01 INTERIOR FINISH PLAN & INTERIOR ELEVATIONS
1. DO NOT SCALE DRAWINGS, CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING SITE DIMENSIONS. IF DISCREPANCIES ARE FOUND, THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY FOR CLARIFICATION.
2. UNLESS SHOWN OTHERWISE, ALL DAMAGE CAUSED BY NEW WORK TO EXISTING AREAS OF THE SITE, CONSTRUCTION, FINISH CONSTRUCTION, ELECTRICAL OR MECHANICAL SYSTEMS SHALL BE REPAIRED TO
MATCH EXISTING CONDITIONS OR AS FOUND PRIOR TO ANY DAMAGE.
3. ALL WORK SHALL BE IN ACCORDANCE WITH THE FIRE AND LIFE SAFETY CODES.
4. THE CONTRACTOR SHALL THOROUGHLY FAMILIARIZE THEMSELVES WITH THE SCOPE OF THE WORK AND SITE ACCESSIBILITY. THE CONTRACTOR IS REMINDED THAT THE PROJECT DRAWINGS INDICATE THE
CONDITIONS AT THE SITE AS IT EXISTED. DEVIATIONS ENCOUNTERED DURING THE WORK SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING STRUCTURES AT THE WORK AREA FROM WEATHER AND OTHER INCLEMENT CONDITIONS. ANY DAMAGE INCURRED DUE TO THE
FAILURE BY THE CONTRACTOR TO PROPERLY PROTECT SUCH WORK SHALL BE REPAIRED AT CONTRACTOR EXPENSE.
6. THE CONTRACTOR SHALL DISPOSE OF ALL REMOVED AND /OR DEMOLISHED MATERIAL. WASTE & DEBRIS CAUSED BY THE NEW WORK. THIS MATERIAL SHALL BE REMOVED FROM THE PROPERTY AND TAKEN TO A
LEGALLY-OPERATED DISPOSAL SITE.
7. ALL CONSTRUCTION TECHNIQUES, MATERIALS, AND FINISHES SHALL BE AS REQUIRED BY THE APPROPRIATE CODE AUTHORITIES. INSTALLATION SHALL FOLLOW THE MANUFACTURERS PUBLISHED SPECIFICATIONS
AND/OR TRADE STANDARDS IN ADDITION TO MEETING OR EXCEEDING THE DESIGN STANDARDS.
8. ALL WEATHER EXPOSED SURFACES SHALL HAVE A WEATHER RESISTIVE BARRIER TO PROTECT THE INTERIOR WALL COVERING AND THE EXTERIOR OPENINGS SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE
THEM WATERPROOF.
9. ALL DIMENSIONS FROM FACE OF FRAMING UNLESS NOTED OTHERWISE.
GENERAL NOTES
CODES
2022 Oregon Structural Specialty Code (OSSC) 2021 Oregon Energy Efficiency Specialty Code (OEESC) 2023 Oregon Electrical Specialty Code (OESC) 2022 Oregon Mechanical Specialty Code (OMSC) 2023 Oregon Plumbing Specialty Code (OPSC) NFPA 13 Standard for the Installation of Sprinkler Systems NFPA 72 National Fire Alarm and Signaling Code
LOCATION: 1955 SCENIC AVE, CENTRAL POINT, OR 97502
MAP & TAX LOT: 372W03AB-4300
DESIGN CRITERIA FOR CITY OF CENTRAL POINT:
EARTHQUAKE: IN ACCORDANCE WITH OSSC SECTION 1613.
SNOW: IN ACCORDANCE WITH OSSC SECTION 1608.
THE MINIMUM DESIGN ROOF SNOW LOAD IS 25 PSF WHERE
APPLICABLE PER THE 2019 OREGON STRUCTURAL SPECIALTY
CODE.
WIND SPEED: IN ACCORDANCE WITH OSSC SECTION 1609.
RAIN: FIGURE 1611.1, 1.3” PER HOUR (100-YEAR, 1-HOUR
RAINFALL)
PROJECT INFORMATION
BUILDING FOOTPRINT: 12000 (BLDG G)
LEVEL 01 REMODEL AREA: 450
BUILDING TYPE: VB
PROJECT SCOPE
• TO REVISE THE ROOM LAYOUT AND PROVIDE THE INDICATED
EXTERIOR DOOR AND CLASSROOM ACCESS FROM THE SOUTH OF
THE BUILDING.
• BID ADDITIVE ALTERNATE 01: PROVIDE THE INDICATED DEMO AND
NEW CONSTRUCTION FOR AN ACCESS DOOR FROM CLASSROOM TO
THE EXISTING CAFETERIA.
• THERE ARE NO INCREASES TO THE BUILDING AREA AND NO CHANGE
OF OCCUPANCIES.
• NO EXISTING FIRE ASSEMBLIES ARE MODIFIED OR NEW FIRE
ASSEMBLIES ADDED.
GENERAL - BLDG G
G00.01 TITLE SHEET & SHEET INDEX
DETAILS - BLDG G
A00.13 DETAILS - ACCESSIBILITY
A04.21 DETAILS
A06.21 DETAILS - DOORS
A09.11 DETAILS - WALL & CEILING
ELECTRICAL
E00.10 SYMBOL LIST AND GENERAL NOTES - ELECTRICAL
E02.51 FLOOR PLAN - BLDG G - LIGHTING
E03.51 FLOOR PLAN - BLDG G - POWER/SIGNAL
MECHANICAL
M00.10 SYMBOL LIST AND GENERAL NOTES - MECHANICAL
M02.51 FLOOR PLAN - BLDG G - MECHANICAL
M03.10 DETAILS - MECHANICAL
PLUMBING
P00.10 SYMBOL LIST AND GENERAL NOTES - PLUMBING
P02.51 FLOOR PLAN - BLDG G - PLUMBING
STRUCTURAL
S0.1 STRUCTURAL GENERAL NOTES
S2.1 ROOF FRAMING PLAN
S6.1 STRUCTURAL DETAILS
WHEELCHAIR MANEUVERING
MANEUVERING CLEARANCES AT DOORS
MENRESTROOM
GENERAL ROOM IDENTIFICATION RESTROOM RESTROOM
INTERIOR SIGNAGE
LATCH SIDE APPROACH LATCH SIDE APPROACH HINGE SIDE APPROACH
HINGE SIDE APPROACH FRONT APPROACH FRONT APPROACH
RADIOLOGY
DIRECTOR
OFFICE
90 TURNS 180 TURN
Pull Side
Push Side
Push Side
Push Side Pull Side m in
24"min.
X
Y
X m in
Y m in
.Y
54" min.
m in
X
24" min.
X
Y m in
NOTE: y=48" minimum if door has both a latch and closer.
1/32 " HIGH RAISED
CHARACTERS, TYP.
GRADE 2 BRAILLE, TYP
RAISED BORDER, TYP
ROOM NUMBER
1/32" HIGH RAISED
INTERN'L SYMBOLS, TYP
3"
1/2 " R TYP
NOTE: MOUNT ACRYLIC SIGNS W/ DOUBLE SIDED FOAM TAPE
ACRYLIC SIGNS 2
CONTRASTING FIN COLORS
NO SCALE
NOTE: y = 54" minimum if door has closer
NOTE: y=48" min if door has closer NOTE: x = 36" min if y = 60", x = 42" min if y = 54"
18" minimum 24" preferred
NOTE: x = 12" if door has both a closer and latch.
GRAB BARS
1 1/2 " CLEAR1.25"-2" DIA. IF
CIRCULAR
IF NON-CIRCULAR
PERIMETER MUST BE
4"-6.25" AND DIAMETER
MUST NOT EXCEED 2.25"
1.
5" m in m in
/4
1/ 2"
BEVELED FLOORING TRANSITIONS
/4 m a x.
/2 m a x.
CARPET ON FLOOR SURFACES
/4 m a x.
BEVELED FLOORING TRANSITIONS
TURNING CLEAR
5'-0" 2'-6"
4' -0
HANDRAILS
1 1/2 " CLEAR
1.25"-2" DIA.
IF CIRCULAR
IF NON-CIRCULAR
PERIMETER MUST BE
4"-6.25" AND DIAMETER
MUST NOT EXCEED 2.25"
TOP AND SIDES MUST BE
UNOBSTRUCTED. UP TO
20% OF BOTTOM MAY BE
OBSTRUCTED FOR
SUPPORTS.
TOP GRIPPING
SURFACE OF
HANDRAIL SHALL
BE 34" - 38"MAX.
ABOVE WALKING
SURFACE
MOUNTING HEIGHT DIMENSIONS
TELEPHONE
CLOCK
LIGHT SWITCH
7' -8
"60
M A
X
M A
X
M A
X
(TO HIGHEST
OPERABLE PART)
OCCUPANCY SIGN
LATCH SIDE PERFERED
THERMOSTAT
OR OTHER
CONTROL
NO SCALE
GENERAL REACH DIMENSIONS
48"
M
IN
Z
48"
Y
X 30" >10" - 24"
M A
X
M A
X
M A
X
30"
10" MAX
21" MAX
M
IN
M A
X
36" MIN
M
IN
M A
X
NOTE: X SHALL BE < 25";
Z SHALL BE > X, WHEN X < 20",
THEN Y SHALL BE 48" MAX
WHEN X IS 20"-25",
THEN Y SHALL BE 44" MAX.
NO SCALE
UNOBSTRUCTED
FRONT APPROACH
UNOBSTRUCTED
SIDE APPROACH
OBSTRUCTED
FRONT APPROACH
OBSTRUCTED
SIDE APPROACH
HANDICAP
ACCESSIBILITY SHEET
3'-0" 4'-0" 3-'0"
3'-6"
6"
3'-6"
M
IN
/4
/8
/2
/2
P
IC
T O
G R
A M
F
IE
LD
6"
C H
A R
A C
T E
R S
A F
F A
LL
S C
A L E
S C
A L E
/2
S C
A L E
/4
S C
A L E
/8
S C
A L E
/3
S C
A L E
/8
O
R W
A rc h it e c tu re T h is d o c u m e n t, a n d t h e i d e a s a n d d e s ig n s i n c o rp o ra te d h e re in a s a n i n s tr u m e n t o f p ro fe s s io n a l s e rv ic e s h a ll re m a in t h e p ro p e rt y o f O
R W
A rc h it e c tu re a n d i s n o t to b e r e p ro d u c e d p u b lis h e d o r u s e d i n w h o le o r in p a rt fo r a n y o th e r p ro je c t o r p u rp o s e w it h o u t th e e x p re s s w ri tt e n a u th o ri z a ti o n o f O
R W
A rc h it e c tu re
PROJECT
DATE
No. Description Date
A
C
BCDEFGHJ
ISSUE
/2
/2
:5
:5
P M A00.13
S C
E N
IC
M
ID
D
L E
S C
H O
O L
G B
L D
G A
C C
E S
S
S c e n ic A v e
C e n tr a l P o in t, O
R
2148.02 G BLDG
9/29/2023
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T
D E
T A
IL
S
A
C C
E S
S
IB
IL
IT
Y
B
IM
:O
R W
A rc h it e c tu re \2
C e n tr a l P o in t S c h o o l D is tr ic t\ P ro je c t F ile s \0
S M
S M
E P
U p g ra d e
W o rk in g
M A
P :3
2W
T :4
WALL ASSEMBLY - INTERIOR
CEILING ASSEMBLY
• T-BAR GRID SYSTEM
• ACT
C1 ACOUSTICAL CEILING TILE
EXTERIOR
• 5/8" GYPSUM WALL BOARD
• 2x6 WD STUD
• 5/8" GYPSUM WALL BOARD
INTERIOR
10 STUD w/ (2) GWB
E X
T E
R
IO
R
IN
T
E R
IO
R
A
FLUSH - CMU
REF SCHEDULE
WIDTH
R E
F S
C H
E D
U
LE
H E
IG
H
T
HOLLOW METAL
REF SCHEDULE
WIDTH
R E
F S
C H
E D
U
LE
H E
IG
H
T
THE CONTRACTOR SHALL:
A. COORDINATE ALL DEMOLITION/PHASING EFFORTS WITH
THE ARCHITECT AND OWNER'S REPRESENTATIVES. EVERY
EFFORT SHALL BE MADE TO MINIMIZE DISRUPTION OF
OWNER'S OPERATIONS AND TO PROVIDE BUILDING USER'S
SAFETY. EXCESSIVE NOISE OR VIBRATIONS SHALL BE PRE-
APPROVED AND COORDINATED WITH THE OWNER'S
REPRESENTATIVE.
B. DISCONNECT & CAP UTILITIES AS NEEDED PER CURRENT
APPLICABLE CODES.
C. VERIFY ALL EXISTING CONSTRUCTION, DIMENSIONS AND
ELEVATIONS AND NOTIFY THE ARCHITECT OF ANY
DISCREPANCIES.
D. REMOVE EXISTING WALLS, FURRING, DOORS, MILLWORK,
PLUMBING FIXTURES, CEILINGS, SOFFITS, ETC. AS
REQUIRED TO EXECUTE THE DEMOLITION / CONSTRUCTION
WORK DESCRIBED BY THE DRAWINGS.
E. THE OWNER SHALL RESERVE THE RIGHT TO SALVAGE ALL
MATERIALS - CONTRACTOR TO COORDINATE WITH OWNER
PRIOR TO WORK BEING DONE.
F. PROVIDE PROTECTION FOR ALL EXISTING BUILDING
MATERIALS AND EQUIPMENT FROM DAMAGE DUE TO ANY
DEMOLITION OR CONSTRUCTION RELATED INCIDENT
PERFORMED UNDER THIS CONTRACT.
G. REPAIR OR REPLACE ITEMS THAT ARE DAMAGED AS A
RESULT OF DEMOLITION OR CONSTRUCTION TO MATCH
EXISTING FINISH AND/OR CONDITION.
H. EXISTING MATERIALS SHALL NOT BE REUSED UNLESS
NOTED OTHERWISE, OR AS AUTHORIZED BY THE
ARCHITECT.
I. PATCH FLOOR AND CEILING PENETRATIONS RESULTING
FROM REMOVAL, OR REROUTING OF NEW OR EXISTING
PIPING, DUCTWORK, CONDUIT, ETC. FINISH AS REQUIRED
FOR NEW OR EXISTING ADJACENT SURFACES.
J. CAP ALL DISCONNECT MECHANICAL PIPING LINES WITHIN
THE WALL OR FLOOR, PATCH AND FINISH AS REQUIRED TO
MATCH NEW OR EXISTING ADJACENT SURFACES.
K. CONTRACTOR SHALL V.I.F. THAT THE AREA BEHIND THE
EXISTING WALL IS VACANT OF ALL MECHANICAL, PLUMBING,
& ELECTRICAL EQUIPMENT, AND OR STRUCTURAL
COLUMNS BEFORE PROCEEDING WITH WALL DEMOLITION.
PROMPTLY NOTIFY ARCHITECT IF MEP EQUIPMENT OR
STRUCTURAL COLUMNS ARE DISCOVERED.
L. SCHOOL IS TO REMAIN OPERATIONAL DURING REGULAR
SCHOOL HOURS.
M. CONTRACTOR TO PROVIDE ANY TEMPORARY ROADS OR
CROSSINGS AS REQUIRED FOR EXECUTION OF THE
CONTRACT. ALL TEMPORARY CONSTRUCTION SHALL BE
REMOVED AT THE COMPLETION OF THE PROJECT.
N. ALL EXISTING VEGETATION, SHRUBS, AND TREES TO
REMAIN SHALL BE PROTECTED AS REQUIRED TO PREVENT
DAMAGE FROM CONSTRUCTION ACTIVITIES. ANY DAMAGED
LANDSCAPING SHALL BE REPLACED WITH LIKE PRODUCT
AND SIZE AT THE DIRECTION OF THE ARCHITECT/OWNER'S
REPRESENTATIVE.
O. CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING
UTILITIES AND LANDSCAPE IRRIGATION. CARE SHOULD BE
TAKEN TO AVOID DAMAGE TO OR DISTURBANCE OF
EXISTING UTILITIES AND IRRIGATION. ALL EXISTING
UTILIITIES AND ENCLOSURES SHALL BE PROTECTED AND
REMAIN ACCESSIBLE AND SERVICEABLE DURING
CONSTRUCTION.
P. REFER TO ELECTRICAL DRAWINGS FOR OUTLETS AND
MOTION SENSORS.
G BLDG HARDWARE GROUP #01
EXTERIOR DOOR #: 365A
QTY DESCRIPTION CATALOG NUMBER FINISH MFR COMMENT
3 EA HINGE 5BB1HW 4.5 X 4.5 NRP
MATCH
OWNERS
EXISTING
FINISH
IVE
1 EA EXIT DEVICE, CONCEALED 98/9949 SERIES, LOCKABLE SCH
1 EA KEY CORE (VERIFY KEYWAY) SCH
1 EA PULL TRIM 252 W/ KEY SCH
1 EA SURFACE CLOSER 4040 LCN
1 EA KICK PLATE 8400 10" X 2" IVE
1 EA GASKETING 488SBK PSA ZER
1 EA SWEEP 200 NA NGP
1 EA ACCESSIBLE THRESHOLD 713 NGP
DEPTH TO BE FIELD
VERIFIED
G BLDG HARDWARE GROUP #02
BID ALT, INTERIOR DOOR #: 395B
QTY DESCRIPTION CATALOG NUMBER FINISH MFR COMMENT
3 EA HINGE 5BB1HW 4.5 X 4.5 NRP
MATCH
OWNERS
EXISTING
FINISH
IVE
1 EA VESTIBULE LOCK ND60PD RHO SCH
1 EA KEY CORE (VERIFY KEYWAY) SCH
1 EA SURFACE CLOSER 4040 LCN
1 EA KICK PLATE 8400 10" X 2" IVE
1 EA WALL STOP WS406/407CCV IVE
1 EA GASKETING 488SBK PSA ZER
1 EA DOOR BOTTOM 364AA-Z49 ZER
1 EA THRESHOLD 547A ZER
DEPTH TO BE FIELD
VERIFIED
S C
A L E
S C
A L E
/2
S C
A L E
/4
S C
A L E
/8
S C
A L E
/3
S C
A L E
/8
O
R W
A rc h it e c tu re T h is d o c u m e n t, a n d t h e i d e a s a n d d e s ig n s i n c o rp o ra te d h e re in a s a n i n s tr u m e n t o f p ro fe s s io n a l s e rv ic e s h a ll re m a in t h e p ro p e rt y o f O
R W
A rc h it e c tu re a n d i s n o t to b e r e p ro d u c e d p u b lis h e d o r u s e d i n w h o le o r in p a rt fo r a n y o th e r p ro je c t o r p u rp o s e w it h o u t th e e x p re s s w ri tt e n a u th o ri z a ti o n o f O
R W
A rc h it e c tu re
PROJECT
DATE
No. Description Date
A
C
BCDEFGHJ
ISSUE
/2
/2
:5
:5
P M A00.21
S C
E N
IC
M
ID
D
L E
S C
H O
O L
G B
L D
G A
C C
E S
S
S c e n ic A v e
C e n tr a l P o in t, O
R
2148.02 G BLDG
9/29/2023
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T
B U
IL
D
IN
G
A S
S E
M B
L
IE
S
D O
O R
S C
H E
D U
L E
B
IM
:O
R W
A rc h it e c tu re \2
C e n tr a l P o in t S c h o o l D is tr ic t\ P ro je c t F ile s \0
S M
S M
E P
U p g ra d e
W o rk in g
M A
P :3
2W
T :4
WALL & CEILING ASSEMBLY NOTES:
1. STRUCTURAL ASPECT OF ALL WALLS SHALL BE PER STRUCTURAL.
2. THERMAL INSULATION SHALL BE INSTALLED PER DETAILS & SPECIFICATIONS. ALL
EXTERIOR WALLS SHALL RECEIVE THERMAL INSULATION. REF WALL TYPES & FLOOR
PLANS FOR INTERIOR WALL TYPES NOTED TO RECEIVE SOUND INSULATION. SOUND
INSULATION SHALL RUN TO 12" ABOVE HIGHEST ADJACENT CEILING.
3. ALL GYPSUM IS 5/8" THICK TYPE 'X' UNO.
4. WALLS WITHIN 2 FEET OF A MOISTURE PRODUCING ITEM SUCH AS, BUT NOT LIMITED
TO SINKS, CONDENSATE LINES, SHALL HAVE MOLD & WATER RESISTANT (MWR)
GYPSUM BOARD TO A HEIGHT OF 4 FEET MINIMUM. (NOTE 5 OF THIS SECTION
GOVERNS)
5. ALL WALLS AND CEILINGS OF RESTROOMS AND CUSTODIAL CLOSETS SHALL BE FULLY
SHEATHED WITH MWR GYPSUM BOARD.
6. GYPSUM BOARD AT NON-RATED &/OR NON-BEARING WALLS SHALL EXTEND 12"
MINIMUM ABOVE THE HIGHEST ADJACENT CEILING.
7. GYPSUM BOARD AT FIRE RATED WALLS SHALL EXTEND UP TO AND ADJOIN WITH THE
FIRE RATED HORIZONTAL ASSEMBLY AS DETAILED.
8. REFER TO INTERIOR ELEVATIONS & FINISH SCHEDULE FOR ADDITIONAL APPLIED
FINISHES WHERE OCCURS.
9. HEIGHT OF WALL SUBSTRATE OR FINISH IS EITHER FULL HEIGHT TO STRUCTURE
ABOVE, OR PARTIAL HEIGHT TO 12" ABOVE HIGHEST ADJACENT CEILING w/ BRACING
PER DETAILS & SPECS. REF STRUCTURAL DRAWINGS. (NOTE 7 OF THIS SECTION
GOVERNS)
10. UNLESS NOTED OTHERWISE, WALL TAG SHALL APPLY TO ENTIRE LENGTH OF WALL
FACING A PARTICULAR SPACE, UNINTERRUPTED BY DOORS OR WINDOWS, AND
TRACING RECESSES AND OTHER CONVOLUTIONS.
11. REFER TO ROOF PLAN FOR DRAFT-STOP LOCATIONS (WHERE OCCURS).
12. WALL TYPES HAVING A FIRE RATING SHALL WORK IN CONJUNCTION WITH FIRE RATED
FLOOR/ CEILING or ROOF/ CEILING ASSEMBLIES TO CREATE AN UNINTERRUPTED FIRE
RESISTIVE MEMBRANE THROUGHOUT.
13. INSTALL ALL NON-RATED FURRED WALLS or NON-RATED DROPPED CEILINGS AFTER
CONSTRUCTION & INSTALLATION OF GYPSUM BOARD MEMBRANES OF ADJACENT FIRE
RATED HORIZONTAL & VERTICAL ASSEMBLIES.
14. INSTALL TILE BACKER BOARD BEHIND ALL TILE APPLICATIONS. IN FIRE RATED
ASSEMBLIES BACKER BOARD SHALL COMPLY WITH RATED ASSEMBLY REQUIREMENTS
OR BE INSTALLED AS A FACE LAYER OVER RATED ASSEMBLY GYPSUM BOARD.
DOOR SCHEDULE
DOOR
NUMBER
DOOR FRAME
HARDWARE
GROUP
DETAILS
COMMENTSINT/EXT WIDTH HEIGHT TYPE MAT FIN
GLAZING
TYPE
FIRE
RATING TYPE MAT FIN HEAD JAMB SILL
395A EXT 3' - 0" 7' - 0" A HM P 1 HM P 01 3/A12.02 2/A12.02 1/A12.02
395B INT 3' - 0" 7' - 0" A HM P 1 HM P 02 3/A12.02 2/A12.02 1/A12.02
N.T.S.
DOOR SLAB TYPE
N.T.S.
DOOR FRAME TYPE
DOOR SCHEDULE & LEGENDS
GENERAL NOTES:HARDWARE GROUPS:
HARDWARE GENERAL NOTES
1. VERIFY NEW HARDWARE MANUFACTURERS COMPLY WITH OWNERS EXISTING HARDWARE STANDARDS
2. HARDWARE FINISH TO MATCH ADJACENT OPENING HARDWARE COLORS
3. OWNER TO VERIFY LOW VOLTAGE/ACCESS CONTROL ON NEW DOORS.
4. HARDWARE TO BE COORDINATED FOR LOW VOLTAGE BY DISTRICT.
N
N
M
M
12 12
10 10
A04.01
A07.01
A07.01
A07.01
A04.01
395A
395B
CLASSROOM
CLASSROOM
395B
PRACTICE
PRACTICE
PRACTICE
OFFICE
OFFICE
STOR
CLOSET
CLOSET
BAND
STOR
CLOSET
A11.01
A11.011 A11.01 3
STUDENT STORE
4"
0"
A07.01
1,242 SF / 15 NET
83 OCC
E A
T D
: 6 0'
-1 0"
0' M
A X
CG
T
A2600.01
A0240.22
A2242.01
HALL
395A
N
N
M
M
9 9
8 8
12 12
10 10
A07.01
A07.01
A0200.01
A1014.01
A07.01
A2337.01
A1014.01
N
N
M
M
12 12
10 10
A07.01
A0240.01
A0240.03
A0240.04
A0240.09
W A
LL
D
E M
O
A0240.12
A0240.13
2' - 4 1/2"
A0240.14
A0240.15
A0240.16
A0240.17
A0240.18
A0240.18
A0240.21
A0240.20
A0240.13
N
N
M
M
9 9
8 8
12 12
10 10
A0240.05
A0240.06
A0240.07
A0240.08 A0240.11
A0200.01
GRAPHICS LEGEND
TO REMAIN
TO BE DEMOLISHED
NEW WORK
EXIT ACCESS
TRAVEL DISTANCE
25'/75' MAX EXIT TRAVEL
DISTANCE
PROVIDED / MAX
ALLOWED
REQ/ CLR
EGRESS
CLEARANCE
SYMBOL
OCCUPANT LOAD
WIDTH REQUIRED
/ PROVIDED
CORNER GUARDCG
T THERMOSTAT (REF MECH DWGS)
KEY PLAN
S C
A L E
S C
A L E
/2
S C
A L E
/4
S C
A L E
/8
S C
A L E
/3
S C
A L E
/8
TRUE
O
R W
A rc h it e c tu re T h is d o c u m e n t, a n d t h e i d e a s a n d d e s ig n s i n c o rp o ra te d h e re in a s a n i n s tr u m e n t o f p ro fe s s io n a l s e rv ic e s h a ll re m a in t h e p ro p e rt y o f O
R W
A rc h it e c tu re a n d i s n o t to b e r e p ro d u c e d p u b lis h e d o r u s e d i n w h o le o r in p a rt fo r a n y o th e r p ro je c t o r p u rp o s e w it h o u t th e e x p re s s w ri tt e n a u th o ri z a ti o n o f O
R W
A rc h it e c tu re
PROJECT
DATE
No. Description Date
A
C
BCDEFGHJ
ISSUE
/2
/2
:5
:5
P M A03.01
S C
E N
IC
M
ID
D
L E
S C
H O
O L
G B
L D
G A
C C
E S
S
S c e n ic A v e
C e n tr a l P o in t, O
R
2148.02 G BLDG
9/29/2023
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T
F L O
O R
P L A
N /R
C P
/E G
R E
S S
D
IA
G R
A M
L E
V E
L
B
IM
:O
R W
A rc h it e c tu re \2
C e n tr a l P o in t S c h o o l D is tr ic t\ P ro je c t F ile s \0
S M
S M
E P
U p g ra d e
W o rk in g
M A
P :3
2W
T :4
1/8" = 1'-0"
1 FLOOR PLAN - G BLDG.
1/8" = 1'-0"
2 RCP - G BLDG.
1/8" = 1'-0"
3 DEMO FLOOR PLAN - G BLDG.
1/8" = 1'-0"
4 DEMO RCP - G BLDG.
KEYNOTES
# NOTE
A0200.01 LOCATION OF (E) MECH ROOM ABOVE
A0240.01 DEMOLISH (E) WALL TO CREATE CORRIDOR
A0240.03 DEMOLISH (E) DOOR, DOOR FRAME, AND HARDWARE
A0240.04 DEMOLISH (E) CASEWORK & SALVAGE TO OWNER
A0240.05 DEMOLISH (E) ACT, GRID, AND STRAPPING
A0240.06 DEMOLISH (E) LIGHT FIXTURE. REF ELEC DWGS
A0240.07 SALVAGE (E) HVAC DIFFUSER. REF MECH DWGS
A0240.08 DEMOLISH PORTION OF (E) ACT, GRID, AND
STRAPPING TO ACCOMMODATE NEW WALL
A0240.09 RELOCATE (E) ELECTRICAL PANEL. REF ELEC DWGS
A0240.11 PROTECT (E) CEILING TO REMAIN DURING WALL DEMO
CREATING SOFFITS
A0240.12 FIELD VERIFY LOCATIONS OF (E) EQUIPMENT, MEP
PRIOR TO DEMOLITION. NOTIFY ARCH IF CONFLICT
OCCURS
A0240.13 DEMO OPENING TO BE ON BLOCK MODULE
A0240.14 TYP: LINE OF PARTIAL WALL TO REMAIN IN PLACE FOR
RE-USE. FIELD VERIFY BASED ON NEW WALL
REQUIREMENTS
A0240.15 DEMO RESILIENT TILE FLOORING, GLUE AND PREPARE
FOR NEW VCT
A0240.16 DEMO BASE ON EX WALL
A0240.17 HEIGHT OF WALL DEMO LIMITED TO LEVEL REQUIRED
TO INSTALL NEW BEAM TO MATCH EXISTING DOOR
HEIGHT
A0240.18 CUT AND DEMO (E) 4" CONCRETE CURB FOR NEW
DOOR OPENING
A0240.20 DEMO SUPPLY TO HOSE BIBB. REF PLUMBING DWGS
A0240.21 DEMO HOSE BIBB. REF PLUMBING DWGS
A0240.22 PATCH AND REPAIR CMU FROM HOSE BIBB DEMO
A1014.01 NEW EXIT SIGN ABOVE DOOR
A2242.01 NEW HOSE BIBB. INSTALL HEIGHT TO MATCH (E) AND
COMPLY WITH ACCESSIBLE REACH RANGES. REF
PLUMBING DWGS
A2337.01 RECONNECT SALVAGED AIR DISTRIBUTION GRILLE.
REF MECH DWGS
A2600.01 ELECTRICAL PANEL. REF ELEC DWGS
BID ALT 01
12 12
10 10
A07.01
A07.01
1' - 3 3/4"
A04.21
A04.21
A04.21
A11.01
A0240.10
A0240.10
NEW RTF(E) RTF
A
LI
G N
W A
LL
S
F
LU
S H
CLOSET
CLOSET
CLOSET
PRACTICE
PRACTICE
PRACTICE
STOR
CLASSROOM
395B
395A
A07.01
OFFICE
HALL
395A
A04.21
A04.21
Sim
A04.21
Sim
A04.21
Sim
A04.21
Sim
N
N
12 12
A04.21
A11.011
395B
CLASSROOM
395B
A0240.19
GRAPHICS LEGEND
TO REMAIN
TO BE DEMOLISHED
NEW WORK
KEY PLAN
S C
A L E
S C
A L E
/2
S C
A L E
/4
S C
A L E
/8
S C
A L E
/3
S C
A L E
/8
TRUE
O
R W
A rc h it e c tu re T h is d o c u m e n t, a n d t h e i d e a s a n d d e s ig n s i n c o rp o ra te d h e re in a s a n i n s tr u m e n t o f p ro fe s s io n a l s e rv ic e s h a ll re m a in t h e p ro p e rt y o f O
R W
A rc h it e c tu re a n d i s n o t to b e r e p ro d u c e d p u b lis h e d o r u s e d i n w h o le o r in p a rt fo r a n y o th e r p ro je c t o r p u rp o s e w it h o u t th e e x p re s s w ri tt e n a u th o ri z a ti o n o f O
R W
A rc h it e c tu re
PROJECT
DATE
No. Description Date
A
C
BCDEFGHJ
ISSUE
/2
/2
:0
:0
P M A04.01
S C
E N
IC
M
ID
D
L E
S C
H O
O L
G B
L D
G A
C C
E S
S
S c e n ic A v e
C e n tr a l P o in t, O
R
2148.02 G BLDG
9/29/2023
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T
E N
L F
L O
O R
P L
A N
N
E W
H A
L L
A L
T E
R N
A T
E D
O O
R O
P T
B
IM
:O
R W
A rc h it e c tu re \2
C e n tr a l P o in t S c h o o l D is tr ic t\ P ro je c t F ile s \0
S M
S M
E P
U p g ra d e
W o rk in g
M A
P :3
2W
T :4
1/2" = 1'-0"
1 ENLARGED PLAN - HALL
1/2" = 1'-0"
2 ENLARGED PLAN - WEST DOOR (BID ALT 01)
KEYNOTES
# NOTE
A0240.10 TYP: AT WALL DEMO LOCATIONS PATCH AND FLUSH
GWB WALLS TO ADJACENT SURFACES
A0240.19 PATCH (E) TILE FLOORING EDGES AND PROVIDE NEW
THRESHOLD AT EXPOSED CONCRETE THRESHOLD
DOOR, REF
SCHEDULE
(E) CMU TO REMAIN
SUSPENSION WALL
ANGLE
ACT; REF CEILING
ASSEMBLIES
STL FRAME ANCHOR,
REF STRUCT DWGS
HOLLOW METAL
FRAME
2x6 STEEL FRAME, REF STRUCT DWGS
EXTERIOR SEALANT
FILL HSS WITH
FIBERGLASS BATT. FILL
SPACE BEHIND DOOR
FRAME WITH LOW
EXPANDING FOAM
SEALANT
INTERIOR SEALANT
CMU GROUTING, VIF
EXIT SIGN
EXTERIOR INTERIOR
DOOR, REF SCHEDULE
ALUMINUM SADDLE w/
WEATHER SEAL
(E) SLAB TO REMAIN
(E) FINISH FLOOR
TO REMAIN
CMU WALL BEYOND
EXTERIOR INTERIOR
5/8 GYPSUM WALL BOARD;
REF WALL ASSEMBLIES, TYP
2x6 WOOD STUDS; REF WALL
ASSEMBLIES
SUSPENSION WALL
ANGLE, TYP
ACT; REF CEILING
ASSEMBLIES, TYP
2x6 TOP PLATES
(E) WOOD JOISTS TO
REMAIN
(E) PLYWOOD
DECKING TO REMAIN
(E) SLAB TO REMAIN
FINISH FLOOR,
REF FINISH PLAN
PT BOTTOM PLATE
3/8" DIA (S) TITEN AHR,
REF STRUCT DWGS
WALL BASE, REF FINISH
PLAN
5/8 GYPSUM WALL BOARD;
REF WALL ASSEMBLIES, TYP
2x6 WOOD STUDS; REF WALL
ASSEMBLIES
5/8 GYPSUM WALL BOARD;
REF WALL ASSEMBLIES, TYP
2x6 WOOD STUDS; REF WALL
ASSEMBLIES
NEW BEAM SUPPORT
STUDS. REF STRUCT DWGS
PATCH (E) WALL AFTER INSTALL
OF NEW LOAD BEARING STUDS
(E) WALL ASSEMBLY TO REMAIN
(E) WALL
ASSEMBLY TO
REMAIN
(E) CMU TO
REMAIN
DOOR, REF
SCHEDULE
STL FRAME ANCHOR,
REF STRUCT DWGS
HOLLOW METAL
FRAME
2x6 STEEL FRAME, REF STRUCT DWGS
INTERIOR SEALANT
FILL HSS WITH FIBERGLASS
BATT. FILL SPACE BEHIND DOOR
FRAME WITH LOW EXPANDING
FOAM SEALANT
EXTERIOR SEALANT
CMU
GROUTING, VIF
EXTERIOR
INTERIOR
5/8 GYPSUM WALL BOARD;
REF WALL ASSEMBLIES, TYP
2x6 WOOD STUDS; REF WALL
ASSEMBLIES
(E) WALL ASSEMBLY
TO REMAIN
(E) CMU TO
REMAIN
DOOR, REF
SCHEDULE
HOLLOW METAL
FRAME
2x6 STEEL FRAME, REF STRUCT DWGS
CMU
GROUTING, VIF
STL FRAME ANCHOR,
REF STRUCT DWGS
INTERIOR SEALANT
INTERIOR SEALANT
FILL HSS WITH FIBERGLASS
BATT. FILL SPACE BEHIND
DOOR FRAME WITH LOW
EXPANDING FOAM SEALANT
5/8 GYPSUM WALL BOARD;
REF WALL ASSEMBLIES, TYP
2x6 WOOD STUDS; REF WALL
ASSEMBLY
(E) WALL ASSEMBLY
TO REMAIN
STRUCTURAL STUDS,
REF STRUCT DWGS
S C
A L E
S C
A L E
/2
S C
A L E
/4
S C
A L E
/8
S C
A L E
/3
S C
A L E
/8
O
R W
A rc h it e c tu re T h is d o c u m e n t, a n d t h e i d e a s a n d d e s ig n s i n c o rp o ra te d h e re in a s a n i n s tr u m e n t o f p ro fe s s io n a l s e rv ic e s h a ll re m a in t h e p ro p e rt y o f O
R W
A rc h it e c tu re a n d i s n o t to b e r e p ro d u c e d p u b lis h e d o r u s e d i n w h o le o r in p a rt fo r a n y o th e r p ro je c t o r p u rp o s e w it h o u t th e e x p re s s w ri tt e n a u th o ri z a ti o n o f O
R W
A rc h it e c tu re
PROJECT
DATE
No. Description Date
A
C
BCDEFGHJ
ISSUE
/2
/2
:0
:0
P M A04.21
S C
E N
IC
M
ID
D
L E
S C
H O
O L
G B
L D
G A
C C
E S
S
S c e n ic A v e
C e n tr a l P o in t, O
R
2148.02 G BLDG
9/29/2023
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T
D E
T A
IL
S
B
IM
:O
R W
A rc h it e c tu re \2
C e n tr a l P o in t S c h o o l D is tr ic t\ P ro je c t F ile s \0
S M
S M
E P
U p g ra d e
W o rk in g
M A
P :3
W
T :4
3" = 1'-0"
8 SECTION DETAIL - DOOR HEAD @ HALL
3" = 1'-0"
7 SECTION DETAIL - DOOR SILL @ HALL
3" = 1'-0"
4 SECTION DETAIL - INT WALL @ CEILING
3" = 1'-0"
3 SECTION DETAIL - INT WALL @ SLAB
3" = 1'-0"
2 PLAN DETAIL - HALL @ CLOSET 381
3" = 1'-0"
6 PLAN DETAIL - HALL @ EXT DOOR
3" = 1'-0"
1 PLAN DETAIL - HALL @ STOR 384
3" = 1'-0"
5 PLAN DETAIL - WEST DOOR (BID ALT 01)
3" = 1'-0"
9 PLAN DETAIL - SOFFIT
3" = 1'-0"
10 TYPICAL SUSPENDED CEILING NOTES
LEVEL 01
0"
M K
LEVEL 02
9' - 0"
A07.01
395A
NEW ACCESS DOOR
LEVEL 01
0"
LEVEL 02
9' - 0"
121110
A07.01
A07.01
OFFICE
MECH RM
C1
A07.01
OPEN
GWB WRAPPED
SOFFITS
A1026.01
LEVEL 01
0"
LEVEL 02
9' - 0"
A07.01
A07.01
C1 PRACTICE
CLOSET
MECH RM
LEVEL 01
0"
LEVEL 02
9' - 0"
A04.21
A04.21
C1
7' - 6" AFF
395A
LEVEL 01
0"
LEVEL 02
9' - 0"
A04.21
A04.21
CLOSET
C1
7' - 6" AFF
C1
7' - 6" AFF
HALL
395A
5/8 GYPSUM WALL BOARD
BLOCKING, TYP
SUSPENSION WALL
ANGLE
(E) ACT TO REMAIN
(E) 2x6 TOP PLATES TO
REMAIN
(E) WOOD JOISTS TO
REMAIN
4 X 8 BEAM, REF
STRUCT DWGS
EXIT SIGN, REF ELEC
DWGS
(E) GYPSUM WALL
BOARD TO REMAIN
(E) THERMAL INSULATION
TO REMAIN
S C
A L E
S C
A L E
/2
S C
A L E
/4
S C
A L E
/8
S C
A L E
/3
S C
A L E
/8
O
R W
A rc h it e c tu re T h is d o c u m e n t, a n d t h e i d e a s a n d d e s ig n s i n c o rp o ra te d h e re in a s a n i n s tr u m e n t o f p ro fe s s io n a l s e rv ic e s h a ll re m a in t h e p ro p e rt y o f O
R W
A rc h it e c tu re a n d i s n o t to b e r e p ro d u c e d p u b lis h e d o r u s e d i n w h o le o r in p a rt fo r a n y o th e r p ro je c t o r p u rp o s e w it h o u t th e e x p re s s w ri tt e n a u th o ri z a ti o n o f O
R W
A rc h it e c tu re
PROJECT
DATE
No. Description Date
A
C
BCDEFGHJ
ISSUE
/2
/2
:0
:0
P M A07.01
S C
E N
IC
M
ID
D
L E
S C
H O
O L
G B
L D
G A
C C
E S
S
S c e n ic A v e
C e n tr a l P o in t, O
R
2148.02 G BLDG
9/29/2023
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T
E X
T E
R
IO
R E
L E
V A
T
IO
N S
B
U
IL
D
IN
G
W A
L L S
E C
T
IO
N S
B
IM
:O
R W
A rc h it e c tu re \2
C e n tr a l P o in t S c h o o l D is tr ic t\ P ro je c t F ile s \0
S M
S M
E P
U p g ra d e
W o rk in g
M A
P :3
W
T :4
3/16" = 1'-0"
1 ELEVATION - SOUTH
3/16" = 1'-0"
2 BUILDING SECTION - NS - HALL
3/16" = 1'-0"
3 BUILDING SECTION - EW - HALL
3/4" = 1'-0"
4 WALL SECTION - NS - HALL @ EXT
3/4" = 1'-0"
5 WALL SECTION - EW - HALL @ CLOSET 381
3" = 1'-0"
6 SECTION DETAIL - SOFFIT @ CLASSROOM 395B
395A
A1014.01
PATCH WALL GWB AND MATCH
ADJACENT LINE AND FINISH
A1014.01
NEW
ACCESS 7'
395B
(E)
(E)/(E)
CLASS
395B
(E
IP
C
-1
(E)
(E)
ACT-2
(E)/RB-1
STOR
(E
IP
C
-1
IPC-1
IPC-1
ACT-2
(E)/RB-1
CLOS
IP
C
-1
(E
IPC-1
IPC-1
ACT-2
(E)/RB-1
CLOS
IP
C
-1
(E
IPC-1
IPC-1
ACT-2
(E)/RB-1
CLOS
IP
C
-1
(E
IPC-1
IPC-1
ACT-2
RT-1/RB-1
HALL
395A
IP
C
-1
IP
C
-1
IPC-1
IPC-1
A1026.01
MATERIALS LEGEND
ACT-2 ACOUSTICAL CEILING TYPE -2
2X4 LAY-IN ACOUSTICAL CEILING
RB-1 BASE TYPE -1
4" RUBBER BASE
COLOR: DISTRICT STANDARD/MATCH EXISTING
RT-1 RESILIENT FLOOR TYPE -1
MATERIAL NAME: TILE FLOORING
COLOR: DISTRICT STANDARD/MATCH EXISTING
PC-1 PAINT COLOR -1
MANUFACTURER: BOD: SHERWIN WILLIAMS
COLOR: DISTRICT STANDARD/MATCH EXISTING
X
X/X
XXXXX
XX
X
X
NORTH WALL FINISH
ROOM NUMBER
ROOM ABBREVIATION
EAST WALL FINISH
SOUTH WALL FINISH
FLOOR FINISH & BASE
CEILING FINISH
WEST WALL FINISH
S C
A L E
S C
A L E
/2
S C
A L E
/4
S C
A L E
/8
S C
A L E
/3
S C
A L E
/8
TRUE
O
R W
A rc h it e c tu re T h is d o c u m e n t, a n d t h e i d e a s a n d d e s ig n s i n c o rp o ra te d h e re in a s a n i n s tr u m e n t o f p ro fe s s io n a l s e rv ic e s h a ll re m a in t h e p ro p e rt y o f O
R W
A rc h it e c tu re a n d i s n o t to b e r e p ro d u c e d p u b lis h e d o r u s e d i n w h o le o r in p a rt fo r a n y o th e r p ro je c t o r p u rp o s e w it h o u t th e e x p re s s w ri tt e n a u th o ri z a ti o n o f O
R W
A rc h it e c tu re
PROJECT
DATE
No. Description Date
A
C
BCDEFGHJ
ISSUE
/2
/2
:0
:0
P M A11.01
S C
E N
IC
M
ID
D
L E
S C
H O
O L
G B
L D
G A
C C
E S
S
S c e n ic A v e
C e n tr a l P o in t, O
R
2148.02 G BLDG
9/29/2023
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T
IN
T
E R
IO
R
F
IN
IS
H
P L
A N
I
N T
E R
IO
R
E L
E V
A T
IO
N
S
B
IM
:O
R W
A rc h it e c tu re \2
C e n tr a l P o in t S c h o o l D is tr ic t\ P ro je c t F ile s \0
S M
S M
E P
U p g ra d e
W o rk in g
M A
P :3
2W
T :4
1/4" = 1'-0"
2 IE - HALL 395A - SOUTH
1/4" = 1'-0"
3 IE - CLASSROOM EAST AT NEW HALL OPENING
1/4" = 1'-0"
1 IE - CLASSROOM 395B - WEST
3/16" = 1'-0"
4 FINISH PLAN - G BLDG.
ROOM FINISH SCHEDULE
ROOM
NO. ROOM NAME ABBREVIATION
CEILING FLOOR WALLS
COMMENTSFINISH MATERIAL BASE NORTH EAST SOUTH WEST
378 CLOSET CLOS ACT-2 (E) RB-1 IPC-1 IPC-1 IPC-1 (E) COLOR OF FINISH PRODUCTS TO MATCH EXISTING
381 CLOSET CLOS ACT-2 (E) RB-1 IPC-1 IPC-1 IPC-1 (E) "
382 CLOSET CLOS ACT-2 (E) RB-1 IPC-1 IPC-1 IPC-1 (E) "
384 STOR STOR ACT-2 (E) RB-1 IPC-1 (E) IPC-1 IPC-1 "
395A HALL HALL ACT-2 RT-1 RB-1 IPC-1 IPC-1 IPC-1 IPC-1 "
395B CLASSROOM CLASS (E) (E) (E) (E) (E) (E) IPC-1 "
KEYNOTES
# NOTE
A1014.01 NEW EXIT SIGN ABOVE DOOR
A1026.01 FULL HEIGHT CORNER GUARD
PHASE KEY
BLDG. G
S C
A L E
S C
A L E
/2
S C
A L E
/4
S C
A L E
/8
S C
A L E
/3
S C
A L E
/8
TRUE
O
R W
A rc h it e c tu re T h is d o c u m e n t, a n d t h e i d e a s a n d d e s ig n s i n c o rp o ra te d h e re in a s a n i n s tr u m e n t o f p ro fe s s io n a l s e rv ic e s h a ll re m a in t h e p ro p e rt y o f O
R W
A rc h it e c tu re a n d i s n o t to b e r e p ro d u c e d p u b lis h e d o r u s e d i n w h o le o r in p a rt fo r a n y o th e r p ro je c t o r p u rp o s e w it h o u t th e e x p re s s w ri tt e n a u th o ri z a ti o n o f O
R W
A rc h it e c tu re
PROJECT
DATE
No. Description Date
A
C
BCDEFGHJ
ISSUE 100% CD
06-05-2023
100% CD
06-05-2023
EXPIRES: 12/31/24
/1
/2
:3
:4
P M
BLD G
E00.10
S C
E N
IC
M
ID
D
L E
S C
H O
O L
S c e n ic
A v e
C e n tr a l P o in t, O
R
2148.02
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T
S Y
M B
O L
L
IS
T A
N D
G E
N E
R A
L N
O T
E S
E
L E
C T
R
IC
A L
B
IM
:O
R W
A rc h it e c tu re \2
C e n tr a l P o in t S c h o o l D is tr ic t\ P ro je c t F ile s \0
S M
S M
E P
U p g ra d e
W o rk in g
M A
P :3
W
T
:4
P R
O
JE
C T
P R
O
JE
C T
P R
O
JE
C T
P R
O
JE
C T
CC CC
OO OO
NN NN
TT TT
AA AA
CC CC
TT TT
ww ww ww ww ww ww .. .. ii ii nn nn tt tt ee ee rr rr ff ff aa aa cc cc ee ee ee ee nn nn gg gg ii ii nn nn ee ee ee ee rr rr ii ii nn nn gg gg
.. .. cc cc oo oo mm mm
K im
W al l
-0
S
W M ai n S tr e e t, S u it e
P o rt la n d
O
R
T E L
.3
.2
GENERAL ELECTRICAL NOTES
SHEET INDEX
ELECTRICAL SYMBOL LIST
NOTE: This is a standard symbol list and not all items listed may be used.
BLD G E00.10 SYMBOL LIST AND GENERAL NOTES - ELECTRICAL
BLD G E02.51 FLOOR PLANS - BLDG G - LIGHTING
BLD G E03.51 FLOOR PLANS - BLDG G - POWER/SIGNAL
Abbreviations
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
ARF ABOVE RAISED FLOOR
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
AWG AMERICAN WIRE GAUGE
A AMPERES, AMBER
AV AUDIO VISUAL
AHJ AUTHORITY HAVING JURISDICTION
AIC AVAILABLE INTERRUPTING CAPACITY
BAS BUILDING AUTOMATION SYSTEM
CA CABLE
CAT CATEGORY
CLG CEILING
CB CIRCUIT BREAKER
C CONDUIT, CLOSE, CONTROL
CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CFOI CONTRACTOR FURNISHED OWNER INSTALLED
COORD COORDINATE
CU COPPER
dB DECIBEL
(X) DEMOLISH
DTL DETAIL
DIA DIAMETER
DIM DIMENSION
DIV DIVISION
DN DOWN
DWG DRAWING
EA EACH
EMT ELECTRICAL METALLIC TUBING
ENT ELECTRICAL NON-METALLIC TUBING
ESD ELECTROSTATIC DISCHARGE
EL ELEVATION
E EMERGENCY
EF EXHAUST FAN
(E) EXISTING
FMS FACILITY MANAGEMENT SYSTEMS
FF FINISH FLOOR
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FMC FLEXIBLE METAL CONDUIT
FT FOOT, FEET
FBO FURNISHED BY OTHERS
G, GND GROUND
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GFI GROUND FAULT INTERRUPTER
GFP GROUND FAULT PROTECTION
GE GROUNDING EQUALIZER
HH HANDHOLE
HT HEIGHT
HC HORIZONTAL CROSS CONNECT
ID IDENTIFICATION
IN INCH, INCHES
IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS
IMC INTERMEDIATE METAL CONDUIT
IG ISOLATED GROUND
KV KILOVOLT
KVA KILOVOLT AMPERES
KW KILOWATT
LED LIGHT EMITTING DIODE
LNC LIQUID TIGHT FLEXIBLE NONMETALLIC CONDUIT
LFMC LIQUIDTIGHT FLEXIBLE METAL CONDUIT
LV LOW VOLTAGE
MOCP MAXIMUM OVERCURRENT PROTECTION
MHz MEGAHERTZ mA MILLIAMPERES
MIN MINIMUM
MCA MINIMUM CIRCUIT AMPS
MISC MISCELLANEOUS
M MOTOR
MCC MOTOR CONTROL CENTER
MT, MTD MOUNT, MOUNTED
MDU MULTI-DWELLING UNIT
NEC NATIONAL ELECTRIC CODE
NESC NATIONAL ELECTRIC SAFETY CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
N NEUTRAL
(N) NEW
NC NORMALLY CLOSED
NO NORMALLY OPEN
N/A NOT APPLICABLE
N.I.C. NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OSP OUTSIDE PLANT
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI OWNER FURNISHED, OWNER INSTALLED
PNL PANEL
PH PHASE
PVC POLY-VINYL-CHLORIDE
PWR POWER
QTY QUANTITY
REF REFERENCE
(R) RELOCATE
RFI REQUEST FOR INFORMATION
REQD REQUIRED
RMC RIGID METAL CONDUIT
RM ROOM
SHT SHEET
SIM SIMILAR
SPKR SPEAKER
STD STANDARD
SPD SURGE PROTECTION DEVICE
SWBD SWITCHBOARD
TBB TELECOMMUNICATIONS BONDING BACKBONE
TGB TELECOMMUNICATIONS GROUNDING BUS BAR
TTB TELEPHONE TERMINAL BOARD
TBD TO BE DETERMINED
XFMR TRANSFORMER
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR
TP TRANSITION POINT
TYP TYPICAL
UG UNDERGROUND
UL UNDERWRITERS LABORATORIES
UPS UNINTERRUPTIBLE POWER SUPPLY
UON UNLESS OTHERWISE NOTED
VFD VARIABLE FREQUENCY DRIVE
VRFY VERIFY
V VOLTS, VOLTAGE
WP WEATHERPROOF
WG WIRE GUARD
W WIRE, WHITE
W/ WITH
W/O WITHOUT
WAO WORK AREA OUTLET
SUBGRADE VAULT POWER
SUBGRADE VAULT TELEPHONE
SURFACE MOUNT EQUIPMENT ENCLOSURE AS NOTED
TELEPHONE UTILITY POLE
UTILITY TRANSFORMER PAD/VAULT
Paging / Intercom
NOTE: FOR TYPICAL MOUNTING HEIGHTS FOR PAGING/INTERCOM
DEVICES, REFER TO DETAIL 1 ON DRAWING E07.10.
RACEWAY ONLY, INDICATOR LIGHT. PROVIDE DOUBLE BACK BOX
AND SINGLE GANG ADAPTER PLATE WITH 3/4"C AND PULL STRING
TO ACCESSIBLE CEILING SPACE.
RACEWAY ONLY, INTERCOM LOCATION - INCLUDES CALL SWITCH.
PROVIDE DOUBLE BACK BOX AND SINGLE GANG ADAPTER PLATE
WITH 3/4"C AND PULL STRING TO ACCESSIBLE CEILING SPACE.
RACEWAY ONLY, IP CONSOLE. PROVIDE DOUBLE BACK BOX AND
SINGLE GANG ADAPTER PLATE WITH 3/4"C AND PULL STRING TO
ACCESSIBLE CEILING SPACE.
RACEWAY ONLY, LARGE MESSAGE BOARD. PROVIDE DOUBLE BACK
BOX AND SINGLE GANG ADAPTER PLATE WITH 3/4"C AND PULL
STRING TO ACCESSIBLE CEILING SPACE.
RACEWAY ONLY, MESSAGE BOARD. PROVIDE DOUBLE BACK BOX
AND SINGLE GANG ADAPTER PLATE WITH 3/4"C AND PULL STRING
TO ACCESSIBLE CEILING SPACE.
RACEWAY ONLY, PAGING SPEAKER. PROVIDE DOUBLE BACK BOX
AND SINGLE GANG ADAPTER PLATE WITH 3/4"C AND PULL STRING
TO ACCESSIBLE CEILING SPACE.
RACEWAY ONLY, PROGRAM MODULE. PROVIDE DOUBLE BACK BOX
AND SINGLE GANG ADAPTER PLATE WITH 3/4"C AND PULL STRING
TO ACCESSIBLE CEILING SPACE.
RACEWAY, PAGING HORN. PROVIDE DOUBLE BACK BOX AND
SINGLE GANG ADAPTER PLATE WITH 3/4"C AND PULL STRING TO
ACCESSIBLE CEILING SPACE.
Raceways
EXISTING CONDUIT CONCEALED IN WALL OR CEILING SPACE
EXISTING CONDUIT ROUTED BELOW FLOOR / GRADE
OVERHEAD PRIMARY SERVICE
OVERHEAD TELEPHONE SERVICE
UNDERGROUND CABLE TELEVISION SERVICE
UNDERGROUND PRIMARY SERVICE
UNDERGROUND SECONDARY SERVICE
UNDERGROUND TELEPHONE SERVICE
CONDUIT CONCEALED IN WALL OR CEILING SPACE
CONDUIT ROUTED BELOW FLOOR / GRADE
CONDUIT ELLED DOWN
CONDUIT ELLED UP
CONDUIT/WIRING CONTINUATION
CONDUIT/WIRING STUBBED OUT WITH END CAP OR INSULATED
PLASTIC BUSHING
FLEXIBLE CONDUIT
Switches and Receptacles
COMBINATION COMMUNICATIONS OUTLET AND DOUBLE DUPLEX
RECEPTACLE, FLUSH FLOOR
COMBINATION COMMUNICATIONS OUTLET AND DUPLEX
RECEPTACLE, FLUSH FLOOR
DUPLEX RECEPTACLE, FLUSH FLOOR
DOUBLE DUPLEX RECEPTACLE, FLUSH FLOOR
DOUBLE DUPLEX RECEPTACLE. SEE LETTER CODE LIST AT DUPLEX
RECEPTACLE FOR OPTIONS
SINGLE RECEPTACLE, FLUSH FLOOR
SINGLE RECEPTACLE. SEE LETTER CODE LIST AT DUPLEX
RECEPTACLE FOR OPTIONS
EQUIPMENT ELECTRICAL CONNECTION
PENDANT RECEPTACLE WITH CORD GRIPS. VERIFY PENDANT
LENGTH. SEE LETTER CODE LIST AT DUPLEX RECEPTACLE FOR
OPTIONS
MULTIPLE CHANNEL SURFACE METAL RECEPTACLE RACEWAY
WITH LOW VOLTAGE DIVIDERS, LENGTH AND RECEPTACLES AS
INDICATED
SURFACE METAL RECEPTACLE RACEWAY
Connections / Equipment
COMBINATION ADJUSTABLE FREQUENCY DRIVE WITH SAFETY
DISCONNECT SWITCH
COMBINATION MOTOR STARTER/FUSED DISCONNECT SWITCH
CONTACTOR COIL
HEAVY DUTY FUSED DISCONNECT SWITCH
MOTOR CONNECTION
NON-FUSED DISCONNECT SWITCH
RELAY
REMOTE DRIVER FOR LED LUMINAIRES
TRANSFORMER
FIRE SMOKE DAMPER
SMOKE DAMPER
CEILING MOUNTED JUNCTION BOX
FLOOR MOUNTED JUNCTION BOX
WALL-MOUNTED JUNCTION BOX
MAGNETIC DOOR HOLDER
Fire Alarm
FIRE ALARM CONTROL PANEL
NOTIFICATION APPLIANCE CIRCUIT PANEL
FIRE ALARM ANNUNCIATOR PANEL
General
DETAIL NUMBER AND SHEET LOCATION
EQUIPMENT IDENTIFICATION
FOOD SERVICE EQUIPMENT / CALCULATION TAG
KEYED NOTE
POINT OF CONNECTION
SECTION NUMBER AND SHEET LOCATION
DEMOLISH
EXISTING WORK
NEW WORK
Lighting
COMBINATION EXIT SIGN WALL MOUNTED AND DUAL HEAD
EMERGENCY EGRESS LIGHTING WITH BATTERY PACK. ARROW(S)
INDICATES DIRECTION IF SHOWN
RECESSED 2' X 2' LUMINAIRE
RECESSED 2' X 2' LUMINAIRE WITH INTEGRAL EMERGENCY
BATTERY CONNECTED TO UNSWITCHED CIRCUIT
RECESSED 2' X 4' LUMINAIRE
SURFACE OR PENDANT MOUNTED STRIPLIGHT
WALL MOUNTED LUMINAIRE
Miscellaneous
BRANCH CIRCUIT WIRING. ARROW INDICATES HOME RUN TO PANEL
WITH CIRCUITS AS NOTED. WIRE SIZE IS #12 AWG MINIMUM UNLESS
NOTED OTHERWISE. SHORT TICK MARKS INDICATE PHASE
CONDUCTORS. LONG TICK MARKS INDICATE NEUTRAL
CONDUCTORS. A SINGLE CURVED TICK MARK INDICATES
INSULATED GREEN GROUND CONDUCTOR. SECOND CURVED TICK
MARK INDICATES "ISOLATED GROUND" (GREEN INSULATION WITH
YELLOW STRIPE) CONDUCTOR.
BRANCH PANEL
CIRCUIT BREAKER
DRY TYPE TRANSFORMER
FLUSH MOUNT EQUIPMENT ENCLOSURE AS NOTED
FLUSH WALL MOUNTED BRANCH PANEL
GROUND BAR
GROUNDING POINT
MAIN DISTRIBUTION PANEL / SUB DISTRIBUTION PANEL
POWER UTILITY POLE
SUBGRADE VAULT CATV
A. COORDINATE LOCATION AND PROTECTION LEVEL OF FIRE AND/OR SMOKE RATED
WALL, CEILINGS AND FLOORS WITH ARCHITECTURAL DRAWINGS. PROVIDE
FIRESTOPPING, REFER TO ELECTRICAL BASIC REQUIREMENTS, SPECIFICATION 26
0000 SECTION E.1.
B. IN PLENUM RATED SPACES, PROVIDE PLENUM RATED WIRING/CABLING (COATED
WITH FLAME RETARDANT) THAT MEET THE REQUIREMENTS TO BE INSTALLED IN
PLENUMS OR INSTALL WIRING/CABLING IN METALLIC RACEWAYS.
UL/IP DRIVER/
RATING POWER SUPPLY LIGHT SOURCE MFG/CATALOG # NOTES
A1 RECESSED 2X2 LED TROFFER; NOMINAL 2FT WIDE
BY 2FT LONG BY XIN TALL
EXTRUDED ALUMINUM CURVED SMOOTH
ACRYLIC LENS
RECESSED WHITE DAMP INTEGRAL DRIVER,
0-10V DIMMING
2000 NOMINAL LUMENS, 3500K
LED, 82CRI
16 LITHONIA BLT SERIES OR APPROVED
EQUIVALENT
FIELD VERIFY EXISTING LIGHTING COLOR
TEMPERATURE AND MATCH.
A1E SAME AS A1 EXCEPT NOTED PROVIDE 10W EMERGENCY SELF-DIAGNOSTIC
BATTERY BACKUP
B2 SURFACE MOUNTED LED STRIP LIGHT; DIRECT
DISTRIBUTION ONLY; NOMINAL 4 IN WIDE BY 3-7/8
IN TALL BY 50 IN LONG
STEEL WITH DIE-CAST END
PLATES
CRESCENT SHAPE
LINEAR REFRACTOR
SURFACE MOUNTED WHITE UL DAMP INTEGRAL DRIVER 2000 NOMINAL LUMENS, 3500K
LED, 80CRI
13.5 LITHONIA LIGHTING WL4-LED SERIES, OR
APPROVED EQUIVALENT
X1 UNIVERSAL MOUNTED THERMOPLASTIC LED
EMERGENCY EXIT SIGN; NOMINAL 17 IN WIDE BY
4.375 IN DEEP BY 8 IN TALL
CONTRACTOR TO
VERIFY BACKBOX
REQUIREMENT
DURING ROUGH-IN
WHITE DAMP NOMINAL 2
WATTS
ISOLITE OR APPROVED EQUIVALENT PROVIDE SELF-DIAGNOSTICS. FIELD VERIFY
EXISTING EXIT SIGN COLOR AND MATCH
LUMINAIRE SCHEDULE
TYPE DESCRIPTION HOUSING SHIELDING MOUNTING FINISH
INPUT
WATTS
NOTES:
THIS LUMINAIRE SCHEDULE IS NOT COMPLETE WITHOUT A COPY OF THE PROJECT MANUAL CONTAINING THE ELECTRICAL SPECIFICATIONS.
DIMMING CONTROL PROTOCOL (0-10VDC, LINE VOLTAGE, DALI, ETC.) COMPATIBLE WITH LIGHTING CONTROL SYSTEM AS SPECIFIED AND SHOWN ON DRAWINGS.
PROVIDE +/- 12 INCH ADJUSTABILITY IN AIRCRAFT CABLE LENGTH WHERE USED.
COORDINATE ALL CEILING TYPES WITH LUMINAIRE LOCATIONS PRIOR TO ORDERING LUMINAIRES. COORDINATE INSTALLATION WITH REFLECTED CEILING PLAN.
SPECIFIED MANUFACTURERS ARE APPROVED TO SUBMIT BID. INCLUSION DOES NOT RELIEVE MANUFACTURER FROM SUPPLYING PRODUCT AS DESCRIBED.
PROVIDE SUBMITTALS THAT INCLUDE THE LUMINAIRE, LAMP AND DIMMABLE LED DRIVER INFORMATION OF EACH LUMINAIRE, WITH APPLICABLE OPTIONS CLEARLY CHECKED OR HIGHLIGHTED. SUBMITTALS NOT INCLUDING THIS INFORMATION WILL BE RETURNED AS REJECTED BY THE ENGINEER OF RECORD.
REMOTE DRIVERS: UL LISTED FOR THEIR APPLICATION. DRIVERS MARKED AS UL RECOGNIZED COMPONENT BUT NOT UL LISTED ARE SUBJECT TO REMOVAL AND REPLACEMENT AT NO COST TO OWNER.
REFER TO FLOOR PLANS FOR LOCATION, CIRCUITING, AND SWITCH LEG FOR EACH REMOTE DRIVER. LABEL ALL REMOTE DRIVERS TO SHOW LUMINAIRE TYPE IDENTIFICATION AND SOURCE CIRCUIT. PROVIDE WIRING BETWEEN REMOTE DRIVER AND LUMINAIRE AS RECOMMENDED BY MANUFACTURER. DO NOT EXCEED MAXIMUM
DISTANCE RECOMMENDED BY MANUFACTURER BETWEEN DRIVER AND FURTHEST LUMINAIRE.
PROVIDE FUNCTIONAL TESTING OF LIGHTING AND LIGHTING CONTROLS IN ACCORDANCE WITH THE 2021 OREGON ENERGY EFFICIENCY SPECIALY CODE (OEESC) FUNCTIONAL TESTING REQUIREMENTS
SS
SS
SS
OS
L
LN
N
M
M
K
K
12 12
10 10
9 9
8 8
PRACTICE
OFFICE
OFFICE
STOR
STUDENT STORE
BAND
CLASSROOM
CLASSROOM
395A
(E)(E)(E)(E)(E)(E)
(E)(E)(E)(E)(E)(E)
(E)(E)(E)(E)(E)(E)
(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)(E)(E)
(E)(E)(E)(E)(E)(E)
(E)(E)(E)(E)(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)(E)
(E)
(E)
(E)
(E)
(E)(E)
(E)
(E)(E)(E)(E)
(E)(E)
STOR
PRACTICE
PRACTICE
PRACTICE
PRACTICE
PRACTICE
(X)
(X)
(X)
(X)
(E)(X)
1 2
L
LN
N
M
M
K
K
12 12
10 10
9 9
8 8
PRACTICE
OFFICE
OFFICE
STOR
STUDENT STORE
BAND
CLASSROOM
CLASSROOM
395A
(E)(E)(E)(E)(E)(E)
(E)(E)(E)(E)(E)(E)
(E)(E)(E)(E)(E)(E)
(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)(E)(E)
(E)(E)(E)(E)(E)(E)
(E)(E)(E)(E)(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)
(E)(E)(E)(E)(E)
(E)
(E)
(E)
(E)
(E)(E)
(E)
(E)(E)(E)(E)
(E)(E)
STOR
PRACTICE
PRACTICE
CLOSET
CLOSET
CLOSET
HALL
395B
S
S
D
S
'A1'
'A1E'
'A1'
'A1E'
'B2'
'B2'
'B2'
'X'
PHASE KEY
BLDG. G
S C
A L E
S C
A L E
/2
S C
A L E
/4
S C
A L E
/8
S C
A L E
/3
S C
A L E
/8
TRUE
O
R W
A rc h it e c tu re T h is d o c u m e n t, a n d t h e i d e a s a n d d e s ig n s i n c o rp o ra te d h e re in a s a n i n s tr u m e n t o f p ro fe s s io n a l s e rv ic e s h a ll re m a in t h e p ro p e rt y o f O
R W
A rc h it e c tu re a n d i s n o t to b e r e p ro d u c e d p u b lis h e d o r u s e d i n w h o le o r in p a rt fo r a n y o th e r p ro je c t o r p u rp o s e w it h o u t th e e x p re s s w ri tt e n a u th o ri z a ti o n o f O
R W
A rc h it e c tu re
PROJECT
DATE
No. Description Date
A
C
BCDEFGHJ
ISSUE 100% CD
06-05-2023
100% CD
06-05-2023
EXPIRES: 12/31/24
/1
/2
:3
:4
P M
BLD G
E02.51
S C
E N
IC
M
ID
D
L E
S C
H O
O L
S c e n ic
A v e
C e n tr a l P o in t, O
R
2148.02
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T
F L O
O R
P L
A N
S
B L
D G
G
L
IG
H T
IN
G
B
IM
:O
R W
A rc h it e c tu re \2
C e n tr a l P o in t S c h o o l D is tr ic t\ P ro je c t F ile s \0
S M
S M
E P
U p g ra d e
W o rk in g
M A
P :3
W
T
:4
P R
O
JE
C T
P R
O
JE
C T
P R
O
JE
C T
P R
O
JE
C T
CC CC
OO OO
NN NN
TT TT
AA AA
CC CC
TT TT
ww ww ww ww ww ww .. .. ii ii nn nn tt tt ee ee rr rr ff ff aa aa cc cc ee ee ee ee nn nn gg gg ii ii nn nn ee ee ee ee rr rr ii ii nn nn gg gg
.. .. cc cc oo oo mm mm
K im
W al l
-0
S
W M ai n S tr e e t, S u it e
P o rt la n d
O
R
T E L
.3
.2
GENERAL SHEET NOTES
A. IN AREAS WHERE THE CEILING IS AFFECTED BY MECHANICAL /
PLUMBING UPGRADES LIGHT FIXTURES ARE TO BE CAREFULLY
REMOVED AND STORED WHILE CONSTRUCTION IS IN PROGRESS THEN
REINSTALLED. SEE MECHANICAL AND PLUMBING DRAWINGS FOR
AREAS THAT WILL BE AFFECTED.
SHEET KEYNOTES
1. MECHANICAL/PLUMBING WORK IN THIS AREA. SEE GENERAL NOTE A,
U.O.N..
2. EXISTING LUMINARIES TO BE DEMOLISHED. MAINTAIN EXISTING CIRCUIT
FOR CONTINUITY AND FOR EXTENSION/RECONNECTION TO NEW
LUMINAIRES.
3. EXTEND FROM EXISTING CIRCUIT IN SPACE.
4. NEW HALLWAY LIGHTING TO BE AUTOMATICALLY TURN ON TO 100%
UPON OCCUPANCY AND AUTOMATICALLY TURN OFF AFTER 20 MINUTES
OF UNOCCUPANCY. MANUAL ON/OFF AT WALL SWTICHES.
5. CIRCUIT EXIT SIGN TO UNSWITCH CIRCUIT IN SPACE.
0' 4' 8' 16'
1/8" = 1'-0"
1 DEMO FLOOR PLAN - LEVEL 01, BLDG G - LIGHTING
0' 4' 8' 16'
1/8" = 1'-0"
2 FLOOR PLAN - LEVEL 01, BLDG G - LIGHTING
H
H
H
IC
IC
IC
LM
B
L
T
H
H
H
IC
IC
IC
LM
B
L
2022-0158
Ckt. C.B. C.B. Ckt.
No. Description / Location A/Pole Note Ph. Note A/Pole Description / Location No.
1 (E) STORE LOAD 20/1 A 20/1 R EXISTING LOAD 2
3 (E) STORE LOAD R 20/1 C 20/1 R EXISTING LOAD 4
5 EXISTING LOAD R 20/1 A 20/1 EXISTING LOAD 6
7 EXISTING LOAD 20/1 C 20/1 R EXISTING LOAD 8
9 EXISTING LOAD R 20/1 A 20/1 R EXISTING LOAD 10
11 EXISTING LOAD R 20/1 C 20/1 R EXISTING LOAD 12
13 EXISTING LOAD H 20/1 A 15/1 G EXISTING LOAD 14
15 (E) IT RACK G 20/1 C 20/1 H (E) EWH-G-1 16
17 (E) POP CORN MACHINE 30/1 A 20/1 SPARE 18
19 EXISTING LOAD 20/1 C 20/1 SPARE 20
21 EXISTING LOAD 20/1 A 20/1 SPARE 22
23 SPARE 20/1 C 20/1 SPARE 24
Connected Load: Ph. A 0 VA 0 Amps Panel Connected Load: 0.0 KVA 0.0 Amps
Sub-Fed Connected Load: 0.0 KVA 0.0 Amps
Connected Load: Ph. C 0 VA 0 Amps Total Demand Load: 0.0 KVA 0.0 Amps
Notes: Accessories:
1.
2.
3.
4.
5.
(E) Panel 'HHH' 120/240V, 1Ph, 3W.; 100A Bus with 60A Main Circuit Breaker Flush Mounted Panelboard
Load Load
(VA)|Type (VA)|Type
L
LN
N
M
M
K
K
12 12
10 10
9 9
8 8
PRACTICE
OFFICE
OFFICE
STOR
STUDENT STORE
BAND
CLASSROOM
CLASSROOM
395A
(E)
(E)
(E)
PANEL 'H'
PANEL 'HHH'
G
PRACTICE
PRACTICE
STOR
PRACTICE
PRACTICE
PRACTICE
TRANSFORMER 'XH'
(R)
(E) 1
(E)
(X)
(E)
(X)
(X)
3(TYP)
(E)
(X)
L
LN
N
M
M
K
K
12 12
10 10
9 9
8 8
PRACTICE
HALL
395B
OFFICE
OFFICE
STOR
STUDENT STORE
BAND
CLASSROOM
CLASSROOM
395A
(E)
(E)
(E)
(E) 3/4"C.
PANEL 'H2'
PANEL 'H'
G
PRACTICE
PRACTICE
CLOSET
CLOSET
CLOSET
(R)4
5 (N)
(N)
(N)
(N)
(E)
PANEL 'HHH'
(E)
(E)
(E)PANEL
'H'
(E)
PANEL
'HHH'
(E) 10 kVA 480- 240/120V, 1∅,3W
XFMR 'XH'
(E)
BLDG 7
(E)PANEL
'H1'
(E)
(E)PANEL
'HH'
(E) 25 kVA 480- 240/120V, 1∅,3W
XFMR 'XH1'
(E)
BLDG 7
(E)PANEL
'H2'
(E)
(E)
BLDG 7
TO EXISTING SWITCHBOARD 'MDS'
(R)
2 4
PHASE KEY
BLDG. G
S C
A L E
S C
A L E
/2
S C
A L E
/4
S C
A L E
/8
S C
A L E
/3
S C
A L E
/8
TRUE
O
R W
A rc h it e c tu re T h is d o c u m e n t, a n d t h e i d e a s a n d d e s ig n s i n c o rp o ra te d h e re in a s a n i n s tr u m e n t o f p ro fe s s io n a l s e rv ic e s h a ll re m a in t h e p ro p e rt y o f O
R W
A rc h it e c tu re a n d i s n o t to b e r e p ro d u c e d p u b lis h e d o r u s e d i n w h o le o r in p a rt fo r a n y o th e r p ro je c t o r p u rp o s e w it h o u t th e e x p re s s w ri tt e n a u th o ri z a ti o n o f O
R W
A rc h it e c tu re
PROJECT
DATE
No. Description Date
A
C
BCDEFGHJ
ISSUE 100% CD
06-05-2023
100% CD
06-05-2023
EXPIRES: 12/31/24
/1
/2
:3
:4
P M
BLD G
E03.51
S C
E N
IC
M
ID
D
L E
S C
H O
O L
S c e n ic
A v e
C e n tr a l P o in t, O
R
2148.02
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T
F L O
O R
P L
A N
S
B L
D G
G
P O
W E
R /S
IG
N
A L
B
IM
:O
R W
A rc h it e c tu re \2
C e n tr a l P o in t S c h o o l D is tr ic t\ P ro je c t F ile s \0
S M
S M
E P
U p g ra d e
W o rk in g
M A
P :3
W
T
:4
P R
O
JE
C T
P R
O
JE
C T
P R
O
JE
C T
P R
O
JE
C T
CC CC
OO OO
NN NN
TT TT
AA AA
CC CC
TT TT
ww ww ww ww ww ww .. .. ii ii nn nn tt tt ee ee rr rr ff ff aa aa cc cc ee ee ee ee nn nn gg gg ii ii nn nn ee ee ee ee rr rr ii ii nn nn gg gg
.. .. cc cc oo oo mm mm
K im
W al l
-0
S
W M ai n S tr e e t, S u it e
P o rt la n d
O
R
T E L
.3
.2
GENERAL SHEET NOTES
A…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .