SJPS+District+Security+Improvements+Drawing+Set+2025-03-10+BIDS.pdf

PDF 4 MB Posted

Attached to
District Security Improvements State and local contract opportunity
Solicitation number
RFP-SJS-250000001718-2
Issued by
Berrien County, Michigan

About this file

This document is a comprehensive security improvements drawing set for Saint Joseph Public Schools (SJPS) located in Saint Joseph, Michigan. The project, identified by the number SJPS2304-0304, involves district-wide security system upgrades across multiple school facilities including Brown Elementary, E.P. Clarke Elementary, Lincoln Elementary, Upton Middle School, and Saint Joseph High School. The drawings detail security demolition plans, new security system layouts, access control configurations, and surveillance camera installations across various school buildings. The project encompasses comprehensive technology improvements including structured cabling, access control hardware, door position sensors, proximity card readers, electric strikes, and IP camera systems.

The technical specifications outline detailed infrastructure modifications involving multiple technology closets (TC-A through TC-I) with Mercury control boards, network switches, and battery backup systems. Camera types include interior and exterior dome, multi-sensor, and fisheye models from Avigilon, strategically placed to provide comprehensive building coverage. Access control components will utilize HID Global iClass proximity readers, ASSA ABLOY door position sensors, and Von Duprin electric hardware. The drawings specify that all existing access control devices will be disconnected from old control boards and reconnected to new Mercury control boards, with re-cabling performed as necessary. The project emphasizes coordination with school administrators for final camera and access control device placements, ensuring optimal security configuration while maintaining existing building infrastructure.

View the file

Other files for this state and local contract opportunity

Other files attached to District Security Improvements, newest first.
File Type Posted
SJPS District Security Improvements.pdf PDF
SJPS+District+Security+Improvements+Specifications+Set+2025-03-10+BIDS.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DISTRICT SECURITY IMPROVEMENTS

SAINT JOSEPH PUBLIC SCHOOLS

SAINT JOSEPH, MI

Project Number: SJPS2304-0304

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

TG01

TI

TL

E

SH

EE

T

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

JACK; SEE LEGEND FOR COLOR

A1-A01

COMPUTER PRINTED SELF-LAMINATED

CABLE WRAP LABEL WITHIN 6 INCHES OF

CABLE END

Cabling Label Detail 6"=1'-0"

ABBREVIATIONS

ABBREVIATION TERMINOLOGY

AC ACCESS CONTROL

AFF ABOVE FINISH FLOOR

ATS AUTOMATIC TRANSFER SWITCH

AV OR A/V AUDIO / VIDEO

BAS BUILDING AUTOMATION SYSTEM

BB BACKERBOARD

CIP CAST IN PLACE

CLG CEILING

CP CONSOLIDATION POINT

EC ELECTRICAL CONTRACTOR

EF ENTRANCE FACILITY

EMT ELECTRICAL METALLIC TUBING

EQ EQUAL

EQUIV EQUIVALENT

ER EQUIPMENT ROOM

EXIST EXISTING

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GRD GROUND

HC HORIZONTAL CROSS-CONNECT

IC INTERMEDIATE CROSS-CONNECT

MC MAIN CROSS-CONNECT

NIC NOT IN CONTRACT

OC ON CENTER

OSP OUTSIDE PLANT

PBB PRIMARY BONDING BUSBAR

PT POKE-THROUGH

RBC RACK BONDING CONDUCTOR

SBB SECONDARY BONDING BUSBAR

SC STRUCTURED CABLING

SCC STRUCTURED CABLING CONTRACTOR

TBB TELECOMMUNICATIONS BONDING BACKBONE

TE TELECOMMUNICATIONS ENCLOSURE

TEBC TELECOMMUNICATIONS EQUIPMENT BONDING CONDUCTOR

TO TELECOMMUNICATIONS OUTLET

TR TELECOMMUNICATIONS ROOM

TYP TYPICAL

UNO UNLESS NOTED OTHERWISE

UPS UNINTERRUPTIBLE POWER SUPPLY

WA WORK AREA

A1-A01

1/8 " M

IN

JACK NUMBER (01 TO 48)

PATCH PANEL ID (A TO Z)

RACK ID (1 OR 2 DIGITS)

CLOSET ID (A TO Z)

AA-A01

1/8 " M

IN

POSITION NUMBER (01 TO 24)

110 BLOCK ID (A TO Z)

BACKBOARD ZONE (A TO Z)

CLOSET ID (A TO Z)

Numbering for 110-Block Term. Drops

NTS

Numbering for Typical Data Drops

NTS

RFI ## #

X# T###

DETAIL NUMBER

SHEET NUMBER WHERE

DETAIL IS LOCATED

ADDENDUM NUMBER BULLETIN NUMBER

RFI OR TSI NUMBER KEYED NOTE NUMBER

RFI OR TSI

DETAIL CALLOUT

NTS

ADDENDUM TAG

NTS

BULLETIN TAG

NTS

RFI OR TSI TAG

NTS

KEYED NOTE TAG

NTS

REVISION CLOUD

NTS

NOTES:

1. USED ON TECHNOLOGY FLOOR PLANS TO

REFERENCE A DETAIL, ELEVATION, OR SYSTEM

OF COMPONENTS ELEVATION ON ANOTHER

SHEET.

NOTES:

1. LOCATED NEXT TO A REVISION CLOUD FOR ANY

REVISIONS AFTER BIDS HAVE BEEN RELEASED,

BEFORE CONTRACT HAS BEEN AWARDED.

NOTES:

1. LOCATED NEXT TO A REVISION CLOUD FOR ANY

REVISIONS AFTER CONTRACT HAS BEEN

AWARDED.

NOTES:

1. DRAWN AROUND REVISION AREA RELATED TO

ANY ADDENDUM OR BULLETIN.

NOTES:

1. REFERENCE TO CORRESPONDING NOTES ON

SAME SHEET THAT HAVE MORE INFORMATION

RELATED TO SYMBOL.

NOTES:

1. RFI (REQUEST FOR INFORMATION) INDICATES A

REVISION AND CORRESPONDING NOTE THAT

DOES NOT AFFECT BUDGET THAT WAS NOT

INITIATED BY TECHNOLOGY CONTRACTOR.

2. TSI (TECHNOLOGY INFORMATION) TAG

INDICATES A REVISION AND CORRESPONDING

NOTE THAT DOES NOT AFFECT BUDGET.

EXISTING TECHNOLOGY

NTS

TECHNOLOGY IDENTIFIER

NOTES:

1. THIN SOLID LINE REPRESENTS EXISTING

TECHNOLOGY TO REMAIN. NO WORK REQUIRED

AT SPECIFIC LOCATION, BUT COULD REQUIRE

EXISTING CABLING AND/OR DEVICES TO BE

MAINTAINED DURING CONSTRUCTION TO

SUPPORT SPECIFIC DEVICE. SEE DRAWINGS

FOR MORE DETAIL.

DEMO TECHNOLOGY

NTS

TECHNOLOGY IDENTIFIER

NOTES:

1. HEAVY DASHED LINE REPRESENTS EXISTING

TECHNOLOGY TO BE REMOVED. COULD

REQUIRE DEMOLITION OF ROUGH-IN, CABLING,

FACEPLATE AND/OR DEVICE. DEVICE MAY NEED

TO BE SALVAGED FOR REINSTALLATION OR

TURNED OVER TO OWNER. SEE DRAWINGS FOR

MORE DETAIL.

NEW TECHNOLOGY

NTS

TECHNOLOGY IDENTIFIER

NOTES:

1. HEAVY SOLID LINE REPRESENTS NEW

TECHNOLOGY. COMPLETE INSTALLATION

OFTEN REQUIRES ROUGH-IN, CABLING,

FACEPLATE AND/OR DEVICE. SEE DRAWINGS

FOR MORE DETAIL.

CM

LR

V

8K

CS

D

H

S

X

F

N

8S

RISER LEGEND

SYMBOL DESCRIPTION

ZONE OR AREA

BY OTHERS OR EXISTING

NEW

OPTIONAL

PLUG INTO 120V RECEPTACLE

CONNECT TO GROUND

WIFI CONNECTION

GENERIC RF CONNECTION

BLUETOOTH CONNCETION

CELLULAR CONNECTION

8P8C (RJ45) NETWORK

KEYED 8P8C (RJ45)

SHIELDED 8P8C (RJ45)

COMPONENT VIDEO

COMPOSITE VIDEO

SVIDEO

HD15 (VGA) VIDEO

DVI VIDEO

HDMI VIDEO

RED & WHITE RCA AUDIO

3.5MM STEREO AUDIO

1/4" STEREO AUDIO

XLR MICROPHONE

COAX TYPE "F"

NEUTRIK NL4MP

USBU

PATCH CORD LEGEND

PURPOSE COLOR LENGTH TOTAL # OF PATCH

CORDS NOTES

SURVEILLANCE CAMERAS VIOLET

15FT FIELD,

1FT

CLOSET

275 EACH LENGTH 1. CAT6

ACCESS CONTROL WHITE

15FT FIELD.

1FT

CLOSET

12 EACH LENGTH 1. CAT6

CABLING AND JACK LEGEND

PURPOSE

PREMISE CABLING JACKS

COLOR RATING MANUFACTURER MODEL TR COLOR WA COLOR MANUFACTURER MODEL SHIELDED

SURVEILLANCE CAMERAS VIOLET

PLENUM GENERAL CABLE GENSPEED 6000

VIOLET VIOLET

PANDUIT

CJ688TGVL CJS688TGVLY

ACCESS CONTROL WHITE WHITE WHITE CJ688TGWH

1. FOR DROPS INSTALLED ABOVE ACCESSIBLE CEILING, PROVIDE MAINTENANCE LOOP

AS INDICATED ON TECHNOLOGY SYMBOL LEGEND. CABLE SHALL BE NEATLY COILED

IN AN "S" LOOP AND SECURED TO BUILDING STRUCTURE AT DROP LOCATION FOR

EASY RELOCATION.

2. LOAD THE LATEST AVAILABLE STABLE FIRMWARE FOR ALL DEVICES WHEN THEY ARE

SUPPLIED FOR THIS PROJECT.

3. IN THE EVENT OF A DISCREPANCY BETWEEN TECHNOLOGY PLANS AND OTHER

DISCIPLINES, CONTRACTOR SHALL SUBMIT AN RFI FOR CLARIFICATION.

4. LABEL CABLES ACCORDING TO "CABLING LABEL DETAIL" ON THIS PAGE.

GENERAL NOTES

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

TG02

TE

CH

NO

LO

GY

G

EN

ER

AL

IN

FO

RM

AT

IO

N

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

LIST OF DRAWINGS

NUMBER TITLE

TG01 TITLE SHEET

TG02 TECHNOLOGY GENERAL INFORMATION

T001 BROWN ES SECURITY DEMO PLAN

T002 E.P. CLARKE ES SECURITY DEMO PLAN

T003 LINCOLN ES FIRST FLOOR SECURITY DEMO PLAN

T004 LINCOLN ES SECOND FLOOR SECURITY DEMO PLAN

T005A UPTON MS SECURITY DEMO PLAN - UNIT A

T005B UPTON MS SECURITY DEMO PLAN - UNIT B

T006A SJHS LOWER FLOOR SECURITY DEMO PLAN - UNIT A

T006B SJHS LOWER FLOOR SECURITY DEMO PLAN - UNIT B

T007A SJHS MAIN FLOOR SECURITY DEMO PLAN - UNIT A

T007B SJHS MAIN FLOOR SECURITY DEMO PLAN - UNIT C

T007C SJHS MAIN FLOOR SECURITY DEMO PLAN - UNIT D

T007D SJHS MAIN FLOOR SECURITY DEMO PLAN - UNIT E

T007E SJHS MAIN FLOOR SECURITY DEMO PLAN - UNIT F & G

T101 BROWN ES SECURITY PLAN

T102 E.P. CLARKE ES SECURITY PLAN

T103 LINCOLN ES FIRST FLOOR SECURITY PLAN

T104 LINCOLN ES SECOND FLOOR SECURITY PLAN

T105A UPTON MS SECURITY PLAN - UNIT A

T105B UPTON MS SECURITY PLAN - UNIT B

T106A SJHS LOWER FLOOR SECURITY PLAN - UNIT A

T106B SJHS LOWER FLOOR SECURITY PLAN - UNIT B

T107A SJHS MAIN FLOOR SECURITY PLAN - UNIT A

T107B SJHS MAIN FLOOR SECURITY PLAN - UNIT C

T107C SJHS MAIN FLOOR SECURITY PLAN - UNIT D

T107D SJHS MAIN FLOOR SECURITY PLAN - UNIT E

T107E SJHS MAIN FLOOR SECURITY PLAN - UNIT F & G

T401 SECURITY SYSTEMS GENERAL INFORMATION

T402 ACCESS CONTROL ELEVATIONS & RISERS

T403 ACCESS CONTROL DETAILS & RISERS

T404 ACCESS CONTROL DETAILS & RISERS

T405 SURVEILLANCE CAMERA RISERS

DEMO EXISTING STRUCTURED CABLING BACKBONE AND PREMISE CABLING X

PROVIDE STRUCTURED CABLING ROUGH-INS (BOXES, CONDUITS, RACEWAY, PATHWAY) X

PROVIDE INCIDENTAL STRUCTURED CABLING PATHWAY X

PROVIDE STRUCTURED CABLING BACKBONE CABLING (AND TERMINATION) X

PROVIDE STRUCTURED CABLING PREMISE CABLING (AND TERMINATION) X

PROVIDE STRUCTURED CABLING PATCH CORDS X

PROVIDE STRUCTURED CABLING RACKS X

SUPPLY NETWORK ELECTRONICS X

CONFIGURE NETWORK ELECTRONICS X

INSTALL NETWORK ELECTRONICS X

INSTALL BACKERBOARD IN TC-CA X

CONNECT TECH EQUIPMENT TO GROUNDING BUSBARS X

DEMO EXISTING CAMERAS (RETURN TO OWNER) X

PROVIDE CAMERA PATHWAY (STRUCTURED CABLING BACKBONE PATHWAY) X

PROVIDE PREMISE CABLING & TERMINATION FOR CAMERA EQUIPMENT X

SUPPLY CAMERA SERVER (SOFTWARE, AND HARDWARE IF NOT VIRTUAL) X

PROVIDE IP ADDRESS FOR CAMERA SERVER X

CONFIGURE CAMERA SERVER X

INSTALL CAMERA SERVER (IF NOT VIRTUAL) X

SUPPLY CAMERA PATCH CORDS X

INSTALL CAMERA PATCH CORDS X

SUPPLY EXISTING CAMERAS X

SUPPLY NEW CAMERAS X

PROVIDE IP ADDRESS RANGE FOR CAMERAS X

CONFIGURE CAMERAS X

VERIFY FINAL PLACEMENT OF CAMERAS PRIOR TO INSTALLATION X

INSTALL CAMERAS X

CORE EXTERIOR WALLS FOR EXTERIOR CAMERAS (COORDINATE FINAL LOCATION) X

WORK SCOPE LEGEND

CA

TE

GO

RY DEFINITION OF WORK

ST

RU

CT

. C

AB

LIN

G

AC

CE

SS

C

ON

TR

OL

DO

OR

H

AR

DW

AR

E

DO

OR

CA

ME

RA

OW

NE

R

ST

RU

CT

UR

ED

C

AB

LIN

G

SU

RV

EI

LL

AN

CE

C

AM

ER

AS

FIBER LEGEND

PURPOSE TYPE RATING MANUFACTURER MODEL

OUTSIDE PLANT OUTSIDE PLANT N/A GENERAL CABLE AQ***4M1A-DT

BACKBONE INDOOR ONLY PLENUM - ARMORED CORNING ***E88-33131-A3

BACKBONE INDOOR/OUTDOOR PLENUM GENERAL CABLE AP***1ANU.BK

SUPPLY ACCESS CONTROL SERVER (SOFTWARE, AND HARDWARE IF NOT VIRTUAL) X

PROVIDE IP ADDRESS FOR ACCESS CONTROL SERVER X

CONFIGURE ACCESS CONTROL SERVER X

INSTALL ACCESS CONTROL SERVER (IF NOT VIRTUAL) X

PROVIDE ACCESS CONTROL ROUGH-INS (BOXES, CONDUITS, RACEWAY, PATHWAY) X

PROVIDE ACCESS CONTROL CABLING X

PROVIDE PREMISE CABLING & TERMINATION FOR ACCESS CONTROL EQUIPMENT X

PROVIDE ACCESS CONTROL DEVICES X

PROVIDE ACCESS CONTROL DOOR HARDWARE X

PREPARE DOOR AND FRAME FOR ACCESS CONTROL HARDWARE X

AC

CE

SS

C

ON

TR

OL

44_H1004A94

TC-C

TC-A

CA

BL

E

TO

T C-

A

CA

BL

E

TO

T

C- B

CA

BL

E

TO

T C-

A

CA

BL

E

TO

T

C- B

CABLE

TO TC-C

CABLE

TO TC-B

CABLE TO TC-C

CABLE TO TC-B

TC-B

CLASSROOM

B137

STORAGE

B142

WORK

ROOM

B139

CLASSROOM

B140

SPEECH

B141

CLASSROOM

B144

STORAGE

B143

GIRL'S

B138

SPECIAL NEEDS

A122

CLASSROOM

B149

WORK

ROOM

B151

PRINCIPAL

B108

OFFICE

B110

RECEPTION

B112

SOCIAL

WORKER

B115

WORK

ROOM

B116

CLASSROOM

B117

TEACHER'S

LOUNGE

B122

CLASSROOM

B125

CLASSROOM

B127

STORAGE

B128

STORAGE

B130

CLASSROOM

B132

WORK

ROOM

B133

CLASSROOM

B135

WORK

ROOM

C108

CLASSROOM

C109

SPECIAL ED.

CLASSROOM

C110

OFFICE

A106

MECH.

ROOM

A107

SPEECH

C112

WORK

ROOM

C113

WORK

ROOM

C111

MUSIC ROOM

C114

CLASSROOM

C116

WORK

ROOM

C118

WORK

ROOM

C120

CLASSROOM

C121

CLASSROOM

C122

CAFETERIA

A109

STORAGE

A115

ROOM

A110

LOCKER ROOM

A116

STORAGE

A113

LOCKER ROOM

A111

TLT.

A112

TLT.

A114

BOILER ROOM

A117

JAN.

A120

TLT.

A121

TLT.

A119

STORAGE

B146

STORAGE

B129

STORAGE

B131

STORAGE

B150

STOR.

B113

RECORDS

B111

CLOSET

B109

TLT.

B107

VESTIBULE

B100

HALLWAY

B105

CORRIDOR

B101

ROOM

B121

ROOM

B120

ROOM

B119

ROOM

B118

WORK

ROOM

B123

BOOK

ROOM

B124

CORRIDOR

A100

CORRIDOR

B104

CORRIDOR

B103

CORRIDOR

B102

CORRIDOR

C101

FOYER

C100

BOY'S

C107

STOR.

C106

JANITOR

C105

GIRL'S

C123

WORK

ROOM

C124 UTILITIES

C125

TLT.

C126

JANITOR

C119

STORAGE

C117

CORRIDOR

C102

BOY'S

B134

BOY'S

B148

GIRL'S

B147

MEDIA CENTER

C128

COMPUTER LAB

C135

OFFICE

C134

COMMUNICATIONS

C133

STORAGE

C132

WORK

ROOM

C131CONFERENCE

C130

MULTI-PURPOSE

C129

CORRIDOR

C103

CORRIDOR

A124

VESTIBULE

A125

WAITING

A126

RECEPTION

A127

WORK

ROOM

A129

CLOSET

A130

HALLWAY

A131

RECORDS

A133

TLT.

A134

ELEC.

A135

PRINCIPAL

A138

OFFICE

A136

CONFERENCE

A137

KITCHEN

A123

ELEC. EQUIP.

A105

TLT.

A118

OFFICE/

STORAGE

B145

ART ROOM

A140

WARE WASH

A103

RECEIVING

A104

KILN

B145

EL

DB

EAC3

EA

C3

EA

C3

EAC3

EA

C3

EA

C3

EAC3

EA

C3

EA

C2

EA

C2

EAC2

EAC3

EAC3

CM

CM

CM

CM

CM

CM

CM CM

CM

CM

CMCM

CM

CM

CM

CM

CM

CM

EN

C

EN

C

N

BROWN ES SECURITY DEMO PLAN

1/16" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T001

BR

OW

N

ES

S

EC

UR

IT

Y

DE

MO

P

LA

N

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

DEMO GENERAL NOTES

1. DEMO ALL ABANDONED CABLES BACK TO THEIR SOURCE.

2. DEMO ALL EXISTING CAMERAS AND MOUNTING HARDWARE.

3. REUSE EXISTING CABLING WHERE POSSIBLE. PROVIDE PROPER LENGTH PATCH

CORD TO EXTEND DROP LOCATION WHERE NEEDED.

4. REUSE EXISTING PENETRATIONS, PATHWAY, AND ROUGH-INS WHERE POSSIBLE.

5. DEMOED EQUIPMENT, WHOLE OR IN PART, SHALL BE PRESENTED TO OWNER FOR

FIRST RIGHT OF REFUSAL BEFORE REMOVAL FROM SITE.

6. COORDINATE FINAL CAMERA LOCATION WITH THE OWNER BEFORE INSTALLATION TO

ENSURE OPTIMAL CAMERA VIEWS.

7. DEMO ALL EXISTING ACCESS CONTROL CABINETS AND ASSOCIATED HARDWARE.

PULL BACK CABLING FOR REINSTALLATION IN NEW CABINET.

8. FIELD INSPECT EXISTING DOOR POSITION SENSORS. DEMO DAMAGED AND

NON-FUNCTIONING SENSORS AND THEIR CABLING TO SOURCE. RE-CABLE AND

INSTALL NEW SENSORS.

TC-A

TC-B

CABLE TO TC-B

CABLE TO TC-A

CA

BL

E

TO

T C-

B

CA

BL

E

TO

T

C- A

EAC2

ELDB

MEDIA CENTER

PROJECT LAB

WORK

ROOM

STORAGE

NEWS

STUDIO

OFFICE

COMPUTER LAB

CONF.

STORAGE

CLASSROOM

CLASSROOM

ELEC.

JAN.

RESTROOM

RESTROOM

FOYER

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

101CLASSROOM

100C

CLASSROOM

100B

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

MDF

----OFFICE

COURTYARD

EAC3

EA

C2

EA

C2

EA

C3

EAC3

EAC3

EA

C3

EAC3

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

CMCM

CM

CM

CM

ENC

ENC

N

E.P. CLARKE ES SECURITY DEMO PLAN

3/32" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T002

E.

P.

C

LA

RK

E

ES

S

EC

UR

IT

Y

DE

MO

P

LA

N

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

DEMO GENERAL NOTES

1. DEMO ALL ABANDONED CABLES BACK TO THEIR SOURCE.

2. DEMO ALL EXISTING CAMERAS AND MOUNTING HARDWARE.

3. REUSE EXISTING CABLING WHERE POSSIBLE. PROVIDE PROPER LENGTH PATCH

CORD TO EXTEND DROP LOCATION WHERE NEEDED.

4. REUSE EXISTING PENETRATIONS, PATHWAY, AND ROUGH-INS WHERE POSSIBLE.

5. DEMOED EQUIPMENT, WHOLE OR IN PART, SHALL BE PRESENTED TO OWNER FOR

FIRST RIGHT OF REFUSAL BEFORE REMOVAL FROM SITE.

6. COORDINATE FINAL CAMERA LOCATION WITH THE OWNER BEFORE INSTALLATION TO

ENSURE OPTIMAL CAMERA VIEWS.

7. DEMO ALL EXISTING ACCESS CONTROL CABINETS AND ASSOCIATED HARDWARE.

PULL BACK CABLING FOR REINSTALLATION IN NEW CABINET.

8. FIELD INSPECT EXISTING DOOR POSITION SENSORS. DEMO DAMAGED AND

ELDB

CLASSROOM 104

A124

WORK

ROOM

A122

CLASSROOM 105

A110

CORRIDOR

A102

HALL

A105

PLAYGROUND

EQUIPMENT

A119

EQUIPMENT

A118

CLASSROOM 102

A117

CLASSROOM 107

A115

GIRLS

A114

CORRIDOR

B106

WORK

ROOM

B136

CLASSROOM 108

B134

CLASSROOM 101

B110

SPECIAL ED.

B111

STAGE

B112

GYMNASIUM

B115

CLASSROOM 109

B132

BOYS

B133

UTILITIES

B126

STORAGE

B125

LOUNGE

B124

ENTRANCE

B103

SERVING

B118

UTILITIES

B122

STORAGE

B121

KITCHEN

B119

PRINCIPAL

B128

HALL

B127

TLT.

B129

SECRETARY

B130 VESTIBULE

B100

CORRIDOR

B102

CORRIDOR

B104

MULTI-PURPOSE

B100

VESTIBULE

A100ELEV. EQUIP.

A125

CORRIDOR

A104

STAIRS

A101

STAIRS

A103

STAIRS

B105

WORK

ROOM

A123

CLASSROOM 103

A121

CLASSROOM 106

A113

WORK

ROOM

A112

WORK

ROOM

A111

RESTROOM

A108

TLT.

A109

JANITOR

A107

VEST.

A106

WORK

ROOM

B135

WORK

ROOM

B108

WORK

ROOM

B109

BOILER

ROOM

B113

P.E. STORAGE

B114

TLT.

B120

ALCOVE

B117

FOYER

B101

CONF.

B100

MEDIA

CENTER

B100

OFFICE

B100

WORK

ROOM

B100

STORAGE

B100

COMMUNICATIONS

B100

COMPUTER LAB

AC

EAC3

EAC3

EAC2

EAC2

EAC2

EAC3

EAC3

EAC3

EAC3

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

EN

C

EN

C

N

LINCOLN ES FIRST FLOOR SECURITY DEMO PLAN

1/16" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T003

LIN

CO

LN

E

S

FI

RS

T

FL

OO

R

SE

CU

RI

TY

D

EM

O

PL

AN

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

DEMO GENERAL NOTES

1. DEMO ALL ABANDONED CABLES BACK TO THEIR SOURCE.

2. DEMO ALL EXISTING CAMERAS AND MOUNTING HARDWARE.

3. REUSE EXISTING CABLING WHERE POSSIBLE. PROVIDE PROPER LENGTH PATCH

CORD TO EXTEND DROP LOCATION WHERE NEEDED.

4. REUSE EXISTING PENETRATIONS, PATHWAY, AND ROUGH-INS WHERE POSSIBLE.

5. DEMOED EQUIPMENT, WHOLE OR IN PART, SHALL BE PRESENTED TO OWNER FOR

FIRST RIGHT OF REFUSAL BEFORE REMOVAL FROM SITE.

6. COORDINATE FINAL CAMERA LOCATION WITH THE OWNER BEFORE INSTALLATION TO

ENSURE OPTIMAL CAMERA VIEWS.

7. DEMO ALL EXISTING ACCESS CONTROL CABINETS AND ASSOCIATED HARDWARE.

PULL BACK CABLING FOR REINSTALLATION IN NEW CABINET.

8. FIELD INSPECT EXISTING DOOR POSITION SENSORS. DEMO DAMAGED AND

5TH GRADE

A206

WORK

ROOM

A208

4TH GRADE

A221

CORRIDOR

A201

WORK

ROOM

A212

5TH GRADE

A213

4TH GRADE

A215

GIRLS'

A216

CORRIDOR

B200

WORK

ROOM

B211

3RD GRADE

B209

3RD GRADE

B204

UPPER

STAGE

B205

BOYS'

B208

ELEVATOR

A204

STORAGE

A205

STAIRS

A200

STAIRS

A203

STAIRS

B201

WORK

ROOM

A207

4TH GRADE

A209

5TH GRADE

A218

WORK

ROOM

A219

WORK

ROOM

A220

RESTROOM

A222

JAN.

A223

MUSIC ROOM

A211

WORK

ROOM

B210

WORK

ROOM

B203

SPEECH

THERAPY

B207

JAN.

A217

CORRIDOR

A202

CM

CM

CM1

N

LINCOLN ES SECOND FLOOR SECURITY DEMO PLAN

1/16" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T004

LIN

CO

LN

E

S

SE

CO

ND

F

LO

OR

S

EC

UR

IT

Y

DE

MO

P

LA

N

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

DEMO GENERAL NOTES

1. DEMO ALL ABANDONED CABLES BACK TO THEIR SOURCE.

2. DEMO ALL EXISTING CAMERAS AND MOUNTING HARDWARE.

3. REUSE EXISTING CABLING WHERE POSSIBLE. PROVIDE PROPER LENGTH PATCH

CORD TO EXTEND DROP LOCATION WHERE NEEDED.

4. REUSE EXISTING PENETRATIONS, PATHWAY, AND ROUGH-INS WHERE POSSIBLE.

5. DEMOED EQUIPMENT, WHOLE OR IN PART, SHALL BE PRESENTED TO OWNER FOR

FIRST RIGHT OF REFUSAL BEFORE REMOVAL FROM SITE.

6. COORDINATE FINAL CAMERA LOCATION WITH THE OWNER BEFORE INSTALLATION TO

ENSURE OPTIMAL CAMERA VIEWS.

7. DEMO ALL EXISTING ACCESS CONTROL CABINETS AND ASSOCIATED HARDWARE.

PULL BACK CABLING FOR REINSTALLATION IN NEW CABINET.

8. FIELD INSPECT EXISTING DOOR POSITION SENSORS. DEMO DAMAGED AND

02 Exist 12

TC-C

TC-A

TC-E

CABLE TO TC-B

CABLE TO TC-A

CABLE TO TC-B

CABLE TO TC-C

CABLE

TO TC-C

CABLE

TO TC-E

CLASSROOM 215

A158

CLASSROOM 217

A157

CLASSROOM 219

A154

CLASSROOM 221

A153

CLASSROOM 223

A150

CLASSROOM 225

A149

SPECIAL ED. 214

A123

SPECIAL ED. 216

A124

CLASSROOM 212

A121

CLASSROOM 213

A120

CLASSROOM 211

A118

CLASSROOM 209

A116

CLASSROOM 203

A110

CLASSROOM 205

A111

CLASSROOM 207

A114

CLASSROOM 210

A130

CLASSROOM 218

A128

OFFICE

A137

CLASSROOM 220

A136

CLASSROOM 204

A144CLASSROOM 226

A146

CLASSROOM 224

A141

CLASSROOM 222

A135

ROOM

A103

CORRIDOR

A111

CORRIDOR

A105

CORRIDOR

A101

VESTIBULE

A100

CORRIDOR

A107

WOMENS

A138

MENS

A134

TLT.

A132

TLT.

A133

ENTRY

A126

ENTRY

A131

ENTRY

A145

STORAGE

A125

STORAGE

A122

STORAGE

A129

STORAGE

A142

CORRIDOR

A104

CORRIDOR

A102

CORRIDOR

A106

STORAGE

A109

STORAGE

A112

STORAGE

A113

STORAGE

A115

STORAGE

A117

STORAGE

A119

STORAGE

A148

STORAGE

A151

STORAGE

A152

STORAGE

A155

STORAGE

A156

STORAGE

A159

STORAGE

A160STORAGE

A161

MEDIA

CENTER

E108

MEDIA

OFFICE

E105

MEDIA

OFFICE

E104

MEDIA

OFFICE

E103

MEDIA

OFFICE

E106

MEDIA

OFFICE

E107

CORRIDOR

E100

TLT.

E101JANITOR

E102

CORRIDOR

B101 CORRIDOR

B100

CORRIDOR

B102

CORRIDOR

B104

CORRIDOR

B103

CORRIDOR

B106

CLASSROOM 405

B142

CLASSROOM 406

B143

KEYBOARD LAB 407

B144

CLASSROOM 311

B146 FOODS 309

B164

CLASSROOM 304

B170

STORAGE 202

B130

CLASSROOM 230

B136

PLANETARIUM

B135

OFFICE

B120

NURSE

B122

CLASSROOM 227

B139

CLASSROOM 229

B140

OFFICE

B141

OFFICE

B138

OFFICE

B147

TLT.

B162

CORRIDOR

B105

COMPUTER

ROOM 313

B148

COMPUTER

ROOM 312

B149

ROOM

B150

ROOM

B163

ROOM 308

B166

ROOM 307

B167

ROOM 306

B168

ROOM 305

B169

OFFICE

B109

OFFICE

B110

OFFICE

B111

OFFICE

B112

OFFICE

B113

OFFICE

B114TLT.

B115

TLT.

B116

TLT.

B117

ROOM

B123

ROOM

B124 ROOM

B121

ROOM

B118

ROOM

B119

ROOM

B132

LOUNGE

B133

ROOM

B134

ROOM

B129

WORK

ROOM

B126

TLT.

B127

TLT.

B128

ROOM

B131

CORRIDOR

D100

MENS

D111

STORAGE

D110

GYM

D112

CLASSROOM 206

A143

SPECIAL ED. 208

A139

EAC1

EA

C1

EAC3

EAC2

EAC2

EAC2

EAC2

EAC3

ELDB

ELDB

EAC1

EAC1

CM CM

CM

CM

CM

CM

CM

CM

CM

CM3

CM1

CM

CM

CM1

CM1 CM1

CM3

CM1

CM

CM

CM

EAC2

EAC3

EN

C

N

UPTON MS SECURITY DEMO PLAN - UNIT A

3/32" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T005A

UP

TO

N

MS

S

EC

UR

IT

Y

DE

MO

P

LA

N

- U

NI

T A

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

DEMO GENERAL NOTES

1. DEMO ALL ABANDONED CABLES BACK TO THEIR SOURCE.

2. DEMO ALL EXISTING CAMERAS AND MOUNTING HARDWARE.

3. REUSE EXISTING CABLING WHERE POSSIBLE. PROVIDE PROPER LENGTH PATCH

CORD TO EXTEND DROP LOCATION WHERE NEEDED.

4. REUSE EXISTING PENETRATIONS, PATHWAY, AND ROUGH-INS WHERE POSSIBLE.

5. DEMOED EQUIPMENT, WHOLE OR IN PART, SHALL BE PRESENTED TO OWNER FOR

FIRST RIGHT OF REFUSAL BEFORE REMOVAL FROM SITE.

6. COORDINATE FINAL CAMERA LOCATION WITH THE OWNER BEFORE INSTALLATION TO

ENSURE OPTIMAL CAMERA VIEWS.

7. DEMO ALL EXISTING ACCESS CONTROL CABINETS AND ASSOCIATED HARDWARE.

PULL BACK CABLING FOR REINSTALLATION IN NEW CABINET.

8. FIELD INSPECT EXISTING DOOR POSITION SENSORS. DEMO DAMAGED AND

TC-E

TC-D

CABLE TO TC-D

CABLE TO TC-A

CA

BL

E

TO

T C-

E

CA

BL

E

TO

T

C- A

CABLE TO TC-D

CABLE TO TC-A

VESTIBULE

A100

A107A106

CORRIDOR

C102

CORR.

C101

VEST.

C100

PASSAGE

C103

STORAGE

C105

STORAGE

C106

CAFETERIA

C106

AUDITORIUM

C107

ROOM

C108

ROOM

C110

ROOM

C111

ROOM

C112

CHOIR 100

C113

BAND 101

C123

ROOM

C124

ROOM

C114 ROOM

C115

ROOM

C116

ROOM

C118ROOM

C119ROOM

C120

HALLWAY

C121

ROOM

C122

ROOM

C126

ROOM 108

C127

ROOM

C128

ORCHESTRA 102

C129

OFFICE 107

C130

INSTRUMENT

STORAGE

C131

ROOM

C132

TLT.

C133

TLT.

C134

CORRIDOR

B101 CORRIDOR

B100

CORRIDOR

B102

CORRIDOR

B104

CORRIDOR

B103

CORRIDOR

B107

CORRIDOR

B106

CLASSROOM 311

B146 FOODS 309

B164

CLASSROOM 304

B170

SCIENCE LAB 303

B171

CLASSROOM 310

B161

WOODS 315

B155

CUSTODIAL

B172

STORAGE 202

B130

CLASSROOM 230

B136

PLANETARIUM

B135

OFFICE

B120

NURSE

B122

CLASSROOM 227

B139

CLASSROOM 229

B140

OFFICE

B141

OFFICE

B138

OFFICE

B147

MENS

B159

WOMENS

B160

TLT.

B162

COMPUTER

ROOM 313

B148

COMPUTER

ROOM 312

B149

ROOM

B150

ROOM

B151

ROOM

B152

ROOM

B163

METALS 314

B158

IND. GRAPHICS

B157

ROOM

B156

ROOM

B154

ROOM 308

B166

ROOM 307

B167

ROOM 306

B168

ROOM 305

B169

ROOM

B173

OFFICE

B109

OFFICE

B110

OFFICE

B111

OFFICE

B112

OFFICE

B113

OFFICE

B114

TLT.

B115

TLT.

B116

TLT.

B117

ROOM

B123

ROOM

B124

ROOM

B121

ROOM

B118

ROOM

B119

ROOM

B132

LOUNGE

B133

ROOM

B134

ROOM

B129

WORK

ROOM

B126

TLT.

B127

TLT.

B128

ROOM

B131

CUSTODIAL

B174

CORRIDOR

D100

CORRIDOR

D101

CORRIDOR

D103

CORRIDOR

D105

CORRIDOR

D106

WOMENS

D109

MENS

D111

STORAGE

D110

GYM

D112

STAIRS

D116

STAIRS

D130

GIRLS

LOCKER

ROOM

D128

BOYS

LOCKER

ROOM

D118

OFFICE

D129

OFFICE

D119

ROOM

D117

ROOM

D131

ROOM

D127

ROOM

D121

TLT.

D120

TLT.

D126

GIRLS TLT.

D125

BOYS TLT.

D122

ROOM

D114

ROOM

D113

KITCHEN 110

D134

TLT.

D139

ROOM

D135

ROOM

D137

ROOM

D138

ROOM

D140

ROOM

D136

GYM

D165

GYM

D164

ROOM

D133

TLT.

D146

TLT.

D145

ROOM

D144

ROOM

D141

ROOM

D147

STAIRS

D143

ROOM

D150

ROOM

D151

ROOM

D158

ROOM

D159

ROOM

D156

ROOM

D153

ROOM

D154

ROOM

D155

GIRLS

D152

BOYS

D157

BOYS

D160

GIRLS

D149

ROOM

D161

STAIRS

D162

CORRIDOR

D104

CORRIDOR

D102

CORRIDOR

D107

ROOM

D142

B ENSEMBLE

ROOM

EAC2

EAC2

EAC2

ELDB

ELDB

EA

C3

EAC3

EAC3

EAC1

EAC1

AC3

EAC1

EAC1EAC3

EA

C1

EA

C1

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

CM

EAC2

EAC3

EA

C1

EA

C1

EA

C1

EN

C

N

UPTON MS SECURITY DEMO PLAN - UNIT B

1/16" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T005B

UP

TO

N

MS

S

EC

UR

IT

Y

DE

MO

P

LA

N

- U

NI

T B

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

DEMO GENERAL NOTES

1. DEMO ALL ABANDONED CABLES BACK TO THEIR SOURCE.

2. DEMO ALL EXISTING CAMERAS AND MOUNTING HARDWARE.

3. REUSE EXISTING CABLING WHERE POSSIBLE. PROVIDE PROPER LENGTH PATCH

CORD TO EXTEND DROP LOCATION WHERE NEEDED.

4. REUSE EXISTING PENETRATIONS, PATHWAY, AND ROUGH-INS WHERE POSSIBLE.

5. DEMOED EQUIPMENT, WHOLE OR IN PART, SHALL BE PRESENTED TO OWNER FOR

FIRST RIGHT OF REFUSAL BEFORE REMOVAL FROM SITE.

6. COORDINATE FINAL CAMERA LOCATION WITH THE OWNER BEFORE INSTALLATION TO

ENSURE OPTIMAL CAMERA VIEWS.

7. DEMO ALL EXISTING ACCESS CONTROL CABINETS AND ASSOCIATED HARDWARE.

PULL BACK CABLING FOR REINSTALLATION IN NEW CABINET.

8. FIELD INSPECT EXISTING DOOR POSITION SENSORS. DEMO DAMAGED AND

CA

BL

E

TO

T C-

D

CA

BL

E

TO

T

C- A

CA

BL

E

TO

T C-

D

CA

BL

E

TO

T

C- C

CA

BL

E

TO

T C-

E

CA

BL

E

TO

T

C- D

CA

BL

E

TO

T C-

D

CA

BL

E

TO

T

C- F

CA

BL

E

TO

T C-

A

CA

BL

E

TO

T

C- B

CA

BL

E

TO

T C-

B

CA

BL

E

TO

T

C- C

TC-B

TC-C

TC-A

TC-D

TC-E

STAIR

#1 LOWER

C107

CORRIDOR

C158

RECEIVING

C157

ALCOVE

C105

CORRIDOR

C154

PASSAGE

C153

CORRIDOR

C104

PASSAGE

C155

REFRIG. &

BULK STORAGE

C128

CORRIDOR

C156

STUDENT

CONCESSIONS

C124

STAFF

DINING

C122

VENDING

C126

ELEV.

EQUIP.

C125

BUSINESS LAB/

CLASSROOM

C123

STAFF

LOUNGE

C120

STUDENT

COMMONS

C119

LECTURE

CLASSROOM

C118

MEETING

ROOM

C114

MEETING

ROOM

C115

HALL

C111

OFFICE

C133

LECTURE

CLASSROOM

C132

WEST

CORRIDOR

C102

LECTURE

CLASSROOM

C135

OFFICE/

WORKROOM

C110

CONFERENCE

ROOM

C141JAN.

C140

WEST

STAIRS

C109

SERVER

ROOM

C136

ELECTRICAL

C138

PASSAGE

C178

OFFICE #1

TECH. DIR.

C174

CONF.

ROOM

C171

MECHANICAL/

ELECTRICAL

C177

TOILET

C175

HALLWAY

C181

DIRECTOR

BUILDING &

GROUNDS

C183

WOMENS'

C164

MENS'

C163

CUSTODIAL

C167

GIRLS'

C166

BOYS'

C165

STAIR

#2 LOWER

C108

VISUAL

ARTS STUDIO

B125

KILN

B124

REFERENCE

MAT'LS

B123

CERAMICS

B122

WORKROOM

B133

STAFF

TOILET

B132

STORAGE

B131

GRAPHICS LAB

B130

CAD LAB

B134

OFFICE

B137

STORAGE

B136

TOILET

B127

TOILET

B128

STORAGE

B142

OFFICE

B141

FAB LAB

B135

WOOD

SHOP

B140

STORAGE

B143

BOILER

ROOM

B145

LECTURE

CLASSROOM

B147

STORAGE

B146

LECTURE

CLASSROOM

B161

WEST

CORRIDOR

B101

SOUTHWEST

VESTIBULE

B104

SOUTH

CORRIDOR

B103

CORRIDOR

B105

BIOLOGY

LAB

B150

VESTIBULE

B151

STAFF

TOILET

B153

CORRIDOR

B152

BIOLOGY

LAB

B154

CHEM/ BIO

STORAGE

B110

SHARED

CHEM/ BIO

WORKROOM

B109

CHEMISTRY

LAB

B107

CHEMISTRY

LAB

B108

PHYSICS

LAB

B119

EAST

CORRIDOR

B102

PHYS.

STOR.

B120

SHARED

PHYS.

WORKRM

B121 PHYSICS

LAB

B118

FOOD

LAB

B170

ELEC.

PASSAGE

C139

NORTH

CORRIDOR

C103

NORTH

CORRIDOR

C101

MATH

E118

STAIR

#2 LOWER

E100

CORRIDOR

E101

CORRIDOR

E102

STAIR

#1 LOWER

E103

MATH

E116

MATH

E110

SPECIAL

EDUCATION

E108

OFFICE

(SP. ED.)

E105

OFFICE

(SP. ED.)

E107

SHARED

CONF.

ROOM

E109

OFFICE

(MATH)

E111

OFFICE

(MATH)

E112

MATH

E113

STORAGE

(MATH)

E114

OFFICE

(MATH)

E115

OFFICE

(MATH)

E117

BOY'S

RESTROOM

E120CUSTODIAL

E121

GIRL'S

RESTROOM

E122

WORKROOM/

OFFICES

E124

SPECIAL

EDUCATION

E106

MATH

E127

MATH

E125

MATH

E128

MATH

E130

STORAGE

E133

LECTURE

CLASSROOM

B160

LECTURE

CLASSROOM

B165

LECTURE

CLASSROOM

B166

CORRIDOR

E104

FACS

C130

WORK ROOM

C173

OPEN

BREAK

AREA

C190

TECH.

FOYER

C191

DRY GOODS

STORAGE

C152

KITCHEN

C151

SERVING

C148

WARE

WASH

C194

T-COM

EQUIP.

C184

WOMENS'

C129

CUSTODIAL

C131

MENS'

C134

OFFICE

B126

MECH.

ROOM

C116

KITCHEN

LOCKERS

C196

OFFICE

C195

STAFF

TOILET

C197

CUSTODIAL

C193

FOOD SRVC.

STOR.

C113

TECH.

CLOSET

C112

MAINT.

OFFICE

C170

FOOD

LAB

C179

CONF.

ROOM

E123

TECH.

CLOSET E

E119

TECH.

CLOSET D

C180

STAIR #3

C267

STAIR #4

C266

STORAGE

B148

GAS

METER

B149

PIPE TUNNEL

COURTYARD

HIGH SCHOOL TABLE/

CHAIR STORAGE

SECURE TECH.

STORAGE

HIGH SCHOOL

BOOK STORAGE

MAINT. SHOP &

CUSTODIAL

CUSTODIAL PAPER

& FILTER STORAGE

EQUIPMENT

GENERAL HIGH

SCHOOL STORAGE

LONGER TERM

DIST. RECORDS

& FILE STORAGE

EAC3

EA

C3

EA

C3

EA

C3

EA

C3

EA

C3EA

C3

EA

C3EAC3

EAC3

CM

CM

CM

CM

CM

CMCMCMCM

CM

CM

CM

CM

CM

CM

CM

CM

CM CM

CM

CM

CM

CM CM

CM

CM CM

CM

CM

CM

CM

CM

CM

ENC

EN

C

N

SJHS LOWER FLOOR SECURITY DEMO PLAN - UNIT A

1/16" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T006A

SJ

HS

LO

W

ER

F

LO

OR

S

EC

UR

IT

Y

DE

MO

P

LA

N

- U

NI

T A

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

DEMO GENERAL NOTES

1. DEMO ALL ABANDONED CABLES BACK TO THEIR SOURCE.

2. DEMO ALL EXISTING CAMERAS AND MOUNTING HARDWARE.

3. REUSE EXISTING CABLING WHERE POSSIBLE. PROVIDE PROPER LENGTH PATCH

CORD TO EXTEND DROP LOCATION WHERE NEEDED.

4. REUSE EXISTING PENETRATIONS, PATHWAY, AND ROUGH-INS WHERE POSSIBLE.

5. DEMOED EQUIPMENT, WHOLE OR IN PART, SHALL BE PRESENTED TO OWNER FOR

FIRST RIGHT OF REFUSAL BEFORE REMOVAL FROM SITE.

6. COORDINATE FINAL CAMERA LOCATION WITH THE OWNER BEFORE INSTALLATION TO

ENSURE OPTIMAL CAMERA VIEWS.

7. DEMO ALL EXISTING ACCESS CONTROL CABINETS AND ASSOCIATED HARDWARE.

PULL BACK CABLING FOR REINSTALLATION IN NEW CABINET.

8. FIELD INSPECT EXISTING DOOR POSITION SENSORS. DEMO DAMAGED AND

GAS

METER

B149

CM

N

SJHS LOWER FLOOR SECURITY DEMO PLAN - UNIT B

1/8" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T006B

SJ

HS

LO

W

ER

F

LO

OR

S

EC

UR

IT

Y

DE

MO

P

LA

N

- U

NI

T B

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

DEMO GENERAL NOTES

1. DEMO ALL ABANDONED CABLES BACK TO THEIR SOURCE.

2. DEMO ALL EXISTING CAMERAS AND MOUNTING HARDWARE.

3. REUSE EXISTING CABLING WHERE POSSIBLE. PROVIDE PROPER LENGTH PATCH

CORD TO EXTEND DROP LOCATION WHERE NEEDED.

4. REUSE EXISTING PENETRATIONS, PATHWAY, AND ROUGH-INS WHERE POSSIBLE.

5. DEMOED EQUIPMENT, WHOLE OR IN PART, SHALL BE PRESENTED TO OWNER FOR

FIRST RIGHT OF REFUSAL BEFORE REMOVAL FROM SITE.

6. COORDINATE FINAL CAMERA LOCATION WITH THE OWNER BEFORE INSTALLATION TO

ENSURE OPTIMAL CAMERA VIEWS.

7. DEMO ALL EXISTING ACCESS CONTROL CABINETS AND ASSOCIATED HARDWARE.

PULL BACK CABLING FOR REINSTALLATION IN NEW CABINET.

8. FIELD INSPECT EXISTING DOOR POSITION SENSORS. DEMO DAMAGED AND

CABLE

TO TC-A

CABLE TO TC-A

CABLE TO TC-I

CABLE

TO TC-I

CA

BL

E

TO

T C-

D

CA

BL

E

TO

T

C- A

CABLE TO TC-D

CABLE TO TC-F

VESTIBULE

D215

CORRIDOR

A242

STAIR

D216

FOREIGN

LANGUAGE

FOREIGN

LANGUAGE

VESTIBULE

D214

VESTIBULE

A246

P.A.C.

LOBBY

A243 TICKET

COUNTER

D221

P.A.C.

ENTRY

A245

PRINCIPAL

A222 GUIDANCE

COUNSELOR

A209

GUIDANCE

COUNSELOR

A210

CAREER

CENTER

A208

RECORDS

A211

SOCIAL

WORK

A207

CORRIDOR

A205

GUIDANCE

COUNSELOR

A212

CONFERENCE

ROOM

A213

HALL

A214

SECRETARY

A215

WAITING

A216

CTE

DIRECTOR

A221

HALL

A217

BREAK

ROOM

A219

HALL

A223

WORKROOM

A220

HIGH SCHOOL

RECEPTION

A226

ASSISTANT

PRINCIPAL

A224

WAITING

A225

LOBBY

A203

CORRIDOR

A204

ATHLETIC

DIRECTOR

A232

ATTEND.

RECEPTION

A228I.S.S.

A234

HALL

A230

COTS

A237

CORRIDOR

A200

HEALTH

CLINIC

A238

STAIR

A201

CONFERENCE

A233

STUDENT

TOILET

A236

DEAN OF

STUDENTS

A235

WAITING

A227

A.D.

RECEPTION

A229

OFFICES

A240

STAIR #4

(UPPER)

C266

ALCOVE

D222

ALCOVE

D220

PASSAGE

D229

STORAGE

D219

EA

C1

EA

C1

EA

C3

EA

C1

EA

C1

EA

C3

EA

C1

EA

C1

EA

C1

EA

C3

EAC3

CM

CM

CM

CM

CM

N

SJHS MAIN FLOOR SECURITY DEMO PLAN - UNIT A

1/8" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T007A

SJ

HS

M

AI

N

FL

OO

R

SE

CU

RI

TY

D

EM

O

PL

AN

UN

IT

A

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

C A

D

E

F

G

DEMO GENERAL NOTES

1. DEMO ALL ABANDONED CABLES BACK TO THEIR SOURCE.

2. DEMO ALL EXISTING CAMERAS AND MOUNTING HARDWARE.

3. REUSE EXISTING CABLING WHERE POSSIBLE. PROVIDE PROPER LENGTH PATCH

CORD TO EXTEND DROP LOCATION WHERE NEEDED.

4. REUSE EXISTING PENETRATIONS, PATHWAY, AND ROUGH-INS WHERE POSSIBLE.

5. DEMOED EQUIPMENT, WHOLE OR IN PART, SHALL BE PRESENTED TO OWNER FOR

FIRST RIGHT OF REFUSAL BEFORE REMOVAL FROM SITE.

6. COORDINATE FINAL CAMERA LOCATION WITH THE OWNER BEFORE INSTALLATION TO

ENSURE OPTIMAL CAMERA VIEWS.

7. DEMO ALL EXISTING ACCESS CONTROL CABINETS AND ASSOCIATED HARDWARE.

PULL BACK CABLING FOR REINSTALLATION IN NEW CABINET.

8. FIELD INSPECT EXISTING DOOR POSITION SENSORS. DEMO DAMAGED AND

CABLE TO TC-D

CABLE TO TC-E

CABLE

TO TC-D

CABLE

TO TC-A

EAC3

LARGE

GROUP

STUDIO

C229

LAB

C226

WORKROOM/

STORAGE

C222

STAIR

#1 UPPER

C202

NEWSPAPER

C219

YEARBOOK

C220

SOCIAL

STUDIES

C254CORRIDOR

C209

SOCIAL

STUDIES

C261

SOCIAL

STUDIES

C251

CONTROL

ROOM

C264

TV STUDIO

C262

SOCIAL

STUDIES

C250

CONF.

ROOM

C244PUBLICATION/

PRODUCTION

CENTER

C242

CORRIDOR

C207

SOCIAL

STUDIES

C247

BOYS'

C243SMALL

GROUP

STUDIO

C241

HALL

C245

CORRIDOR

C208

STAIR

#2 UPPER

C206

STAIR #3

(UPPER)

C267

ENGLISH

C228

CORRIDOR

C200

ENGLISH

C231

ENGLISH

C215

ENGLISH

C216

LEARNING

COMMONS

C204

MEDIA

CENTER

C230

CONF.

ROOM

C234

MEDIUM

GROUP

STUDIO

C233

SMALL

GROUP

STUDIO

C236

SMALL

GROUP

C225

OFFICE

C221

CORRIDOR

C201 GIRL'S

C237

STAIR #4

C266

OFFICES

C258

SOCIAL

STUDIES

C259

SOCIAL

STUDIES

C255

SOCIAL

STUDIES

C260

ENGLISH

C224

ENGLISH

C227

ENGLISH

C211

ENGLISH

C212

STAIR #4

(UPPER)

C266

CORRIDOR

C213

HALL

C203

CORRIDOR

C214

CM CM

CM CM

N

SJHS MAIN FLOOR SECURITY DEMO PLAN - UNIT C

1/8" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T007B

SJ

HS

M

AI

N

FL

OO

R

SE

CU

RI

TY

D

EM

O

PL

AN

UN

IT

C

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

C A

D

E

F

G

DEMO GENERAL NOTES

1. DEMO ALL ABANDONED CABLES BACK TO THEIR SOURCE.

2. DEMO ALL EXISTING CAMERAS AND MOUNTING HARDWARE.

3. REUSE EXISTING CABLING WHERE POSSIBLE. PROVIDE PROPER LENGTH PATCH

CORD TO EXTEND DROP LOCATION WHERE NEEDED.

4. REUSE EXISTING PENETRATIONS, PATHWAY, AND ROUGH-INS WHERE POSSIBLE.

5. DEMOED EQUIPMENT, WHOLE OR IN PART, SHALL BE PRESENTED TO OWNER FOR

FIRST RIGHT OF REFUSAL BEFORE REMOVAL FROM SITE.

6. COORDINATE FINAL CAMERA LOCATION WITH THE OWNER BEFORE INSTALLATION TO

ENSURE OPTIMAL CAMERA VIEWS.

7. DEMO ALL EXISTING ACCESS CONTROL CABINETS AND ASSOCIATED HARDWARE.

PULL BACK CABLING FOR REINSTALLATION IN NEW CABINET.

8. FIELD INSPECT EXISTING DOOR POSITION SENSORS. DEMO DAMAGED AND

CABLE TO TC-F

TC-F

VESTIBULE

D215

CORRIDOR

A242

STAIR

D216

GIRLS'

D225

TOILET

D228

WOMENS'

D226

WORKROOM

E230

OFFICE

(FOREIGN

LANGUAGE)

E207

FOREIGN

LANGUAGE

E208

OFFICE

JAN.

CLOSET

E206

STAIR

#2 UPPER

E200

CONF.

ROOM

E229

CORRIDOR

D201

BOYS'

D223

HALL

D235

MENS'

D224

TOILET

D227

DRESSING

D232

HALL

D234

STAIRS

D233

DRESSING

D231

GREEN

ROOM

D236

VESTIBULE

D214

VESTIBULE

A246

TICKET

COUNTER

D221

P.A.C.

ENTRY

A245

AUDITORIUM

D218

CORRIDOR

D213

STAGE

D237

STAIRS

D217

SCENE

SHOP

D296

STAFF

TOILET

D297

HALL

D292

UNIFORM

STORAGE

D249ALCOVE

D248

CORRIDOR

D204B

STORAGE

D266

#1 VOCAL

PRACTICE

D268

SMALL

PRACTICE

D262

MEDIUM

PRACTICE

D254

ENSEMBLE

PRACTICE

D247CORRIDOR

D203

UNISEX

TOILET

D246

SMALL

PRACTICE

D245

SMALL

PRACTICE

D253

STORAGE

D244

STAIR

D211

STORAGE

D239

TECH.

CLOSET F

D238

SMALL

PRACTICE

D243

HALL

D209

#3 VOCAL

PRACTICE

D265

VOCAL

D271

#2 VOCAL

PRACTICE

D267

CORRIDOR

D206

SMALL

PRACTICE

D256

CORRIDOR

D208

SMALL

PRACTICE

D264

SMALL

PRACTICE

D263

PRACTICE

D258

PRACTICE

D257

STAFF

TOILET

D291

INSTRUMENT

STORAGE

D260

VESTIBULE

D294

INSTRUMENT

STORAGE

D274

WOMENS'

D277

JAN.

CLOSET

D290

HALL

D280

WORKROOM

D275

HALL

D282

MENS'

D281

OFFICES

D283

BAND

ROOM

D242

CORRIDOR

D212

STORAGE

D240

STORAGE

D241

ORCHESTRA

REHEARSAL

D295

INSTRUMENT

STORAGE

D276

CORRIDOR

D204A

STAIRS

D235

ALCOVE

D207

ALCOVE

D222

ALCOVE

D220

PASSAGE

D229

STAGE

RIGHT

D298

STORAGE

D219

EA

C1

EA

C1

EA

C1

EA

C3

EA

C3

CM

CM

CM

ENC

N

SJHS MAIN FLOOR SECURITY DEMO PLAN - UNIT D

1/8" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T007C

SJ

HS

M

AI

N

FL

OO

R

SE

CU

RI

TY

D

EM

O

PL

AN

UN

IT

D

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

C A

D

E

F

G

DEMO GENERAL NOTES

1. DEMO ALL ABANDONED CABLES BACK TO THEIR SOURCE.

2. DEMO ALL EXISTING CAMERAS AND MOUNTING HARDWARE.

3. REUSE EXISTING CABLING WHERE POSSIBLE. PROVIDE PROPER LENGTH PATCH

CORD TO EXTEND DROP LOCATION WHERE NEEDED.

4. REUSE EXISTING PENETRATIONS, PATHWAY, AND ROUGH-INS WHERE POSSIBLE.

5. DEMOED EQUIPMENT, WHOLE OR IN PART, SHALL BE PRESENTED TO OWNER FOR

FIRST RIGHT OF REFUSAL BEFORE REMOVAL FROM SITE.

6. COORDINATE FINAL CAMERA LOCATION WITH THE OWNER BEFORE INSTALLATION TO

ENSURE OPTIMAL CAMERA VIEWS.

7. DEMO ALL EXISTING ACCESS CONTROL CABINETS AND ASSOCIATED HARDWARE.

PULL BACK CABLING FOR REINSTALLATION IN NEW CABINET.

8. FIELD INSPECT EXISTING DOOR POSITION SENSORS. DEMO DAMAGED AND

CABLE TO TC-D

CABLE TO TC-E

CORRIDOR

E204

STAIR

#1 UPPER

E203

SPECIAL

EDUCATION

E220

OFFICE

(SP. ED.)

E219

SPECIAL

EDUCATION

E218 CORRIDOR

E202

OFFICE

(SP. ED.)

E217

CONF.

ROOM

E216

COMPUTER

LAB

E222

OFFICE

(FOREIGN

LANGUAGE)

E213

OFFICE

(FOREIGN

LANGUAGE)

E214

FOREIGN

LANGUAGE

E215

STORAGE

(FOREIGN

LANGUAGE)

E211

FOREIGN

LANGUAGE

E212

COMPUTER

LAB

E224

LANGUAGE

LAB

E225

WORKROOM

E230

OFFICE

(FOREIGN

LANGUAGE)

E207

FOREIGN

LANGUAGE

E208

OFFICE

(FOREIGN

LANGUAGE)

E210

FOREIGN

LANGUAGE

E209

CORRIDOR

E201

JAN.

CLOSET

E206

STAIR

#2 UPPER

E200

CONF.

ROOM

E229

CORRIDOR

D201

GUIDANCE

COUNSELOR

A209

GUIDANCE

COUNSELOR

A210

CAREER

CENTER

A208

RECORDS

A211

SOCIAL

WORK

A207

CORRIDOR

A205

EA

C3

CM

N

SJHS MAIN FLOOR SECURITY DEMO PLAN - UNIT E

1/8" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T007D

SJ

HS

M

AI

N

FL

OO

R

SE

CU

RI

TY

D

EM

O

PL

AN

UN

IT

E

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

C A

D

E

F

G

DEMO GENERAL NOTES

1. DEMO ALL ABANDONED CABLES BACK TO THEIR SOURCE.

2. DEMO ALL EXISTING CAMERAS AND MOUNTING HARDWARE.

3. REUSE EXISTING CABLING WHERE POSSIBLE. PROVIDE PROPER LENGTH PATCH

CORD TO EXTEND DROP LOCATION WHERE NEEDED.

4. REUSE EXISTING PENETRATIONS, PATHWAY, AND ROUGH-INS WHERE POSSIBLE.

5. DEMOED EQUIPMENT, WHOLE OR IN PART, SHALL BE PRESENTED TO OWNER FOR

FIRST RIGHT OF REFUSAL BEFORE REMOVAL FROM SITE.

6. COORDINATE FINAL CAMERA LOCATION WITH THE OWNER BEFORE INSTALLATION TO

ENSURE OPTIMAL CAMERA VIEWS.

7. DEMO ALL EXISTING ACCESS CONTROL CABINETS AND ASSOCIATED HARDWARE.

PULL BACK CABLING FOR REINSTALLATION IN NEW CABINET.

8. FIELD INSPECT EXISTING DOOR POSITION SENSORS. DEMO DAMAGED AND

CABLE TO TC-A

CABLE TO TC-I

CABLE

TO TC-I

CABLE TO TC-G

CABLE TO TC-I

CABLE TO TC-G

CABLE TO TC-I

TC-I

TC-G

ATHLETIC

DIRECTOR

A232COTS

HEALTH

CLINIC

CONFERENCE

A233 A.D.

EA

C3

EA

C3

EAC3

EAC3

EAC3

EAC3

EAC3

CM

CM

CM

CM

CM

CM

CM

CM

CM

EA

C3

EAC1

EAC1

EAC1

EN

C

EN

C

N

SJHS MAIN FLOOR SECURITY DEMO PLAN - UNIT F & G

1/16" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T007E

SJ

HS

M

AI

N

FL

OO

R

SE

CU

RI

TY

D

EM

O

PL

AN

UN

IT

F

G

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

C A

D

E

F

G

DEMO GENERAL NOTES

1. DEMO ALL ABANDONED CABLES BACK TO THEIR SOURCE.

2. DEMO ALL EXISTING CAMERAS AND MOUNTING HARDWARE.

3. REUSE EXISTING CABLING WHERE POSSIBLE. PROVIDE PROPER LENGTH PATCH

CORD TO EXTEND DROP LOCATION WHERE NEEDED.

4. REUSE EXISTING PENETRATIONS, PATHWAY, AND ROUGH-INS WHERE POSSIBLE.

5. DEMOED EQUIPMENT, WHOLE OR IN PART, SHALL BE PRESENTED TO OWNER FOR

FIRST RIGHT OF REFUSAL BEFORE REMOVAL FROM SITE.

6. COORDINATE FINAL CAMERA LOCATION WITH THE OWNER BEFORE INSTALLATION TO

ENSURE OPTIMAL CAMERA VIEWS.

7. DEMO ALL EXISTING ACCESS CONTROL CABINETS AND ASSOCIATED HARDWARE.

PULL BACK CABLING FOR REINSTALLATION IN NEW CABINET.

8. FIELD INSPECT EXISTING DOOR POSITION SENSORS. DEMO DAMAGED AND

44_H1004A94

TC-C

TC-A

CA

BL

E

TO

T C-

A

CA

BL

E

TO

T

C- B

CA

BL

E

TO

T C-

A

CA

BL

E

TO

T

C- B

CABLE

TO TC-C

CABLE

TO TC-B

CABLE TO TC-C

CABLE TO TC-B

TC-B

CM6 CM6

CM2

CM

CM4

CM1

CM3

CM5

CM2

CM4

CM3CM9 CM7

CM5

CM3

CM6

CM6

CM6CM4

CM3

CM9 CM6

CM6

CM1

CM

CM

CM1

CM1

CLASSROOM

B137

STORAGE

B142

WORK

ROOM

B139

CLASSROOM

B140

SPEECH

B141

CLASSROOM

B144

STORAGE

B143

GIRL'S

B138

SPECIAL NEEDS

A122

CLASSROOM

B149

WORK

ROOM

B151

PRINCIPAL

B108

OFFICE

B110

RECEPTION

B112

SOCIAL

WORKER

B115

WORK

ROOM

B116

CLASSROOM

B117

TEACHER'S

LOUNGE

B122

CLASSROOM

B125

CLASSROOM

B127

STORAGE

B128

STORAGE

B130

CLASSROOM

B132

WORK

ROOM

B133

CLASSROOM

B135

WORK

ROOM

C108

CLASSROOM

C109

SPECIAL ED.

CLASSROOM

C110

OFFICE

A106

MECH.

ROOM

A107

SPEECH

C112

WORK

ROOM

C113

WORK

ROOM

C111

MUSIC ROOM

C114

CLASSROOM

C116

WORK

ROOM

C118

WORK

ROOM

C120

CLASSROOM

C121

CLASSROOM

C122

CAFETERIA

A109

STORAGE

A115

ROOM

A110

LOCKER ROOM

A116

STORAGE

A113

LOCKER ROOM

A111

TLT.

A112

TLT.

A114

BOILER ROOM

A117

JAN.

A120

TLT.

A121

TLT.

A119

STORAGE

B146

STORAGE

B129

STORAGE

B131

STORAGE

B150

STOR.

B113

RECORDS

B111

CLOSET

B109

TLT.

B107

VESTIBULE

B100

HALLWAY

B105

CORRIDOR

B101

ROOM

B121

ROOM

B120

ROOM

B119

ROOM

B118

WORK

ROOM

B123

BOOK

ROOM

B124

CORRIDOR

A100

CORRIDOR

B104

CORRIDOR

B103

CORRIDOR

B102

CORRIDOR

C101

FOYER

C100

BOY'S

C107

STOR.

C106

JANITOR

C105

GIRL'S

C123

WORK

ROOM

C124 UTILITIES

C125

TLT.

C126

JANITOR

C119

STORAGE

C117

CORRIDOR

C102

BOY'S

B134

BOY'S

B148

GIRL'S

B147

MEDIA CENTER

C128

COMPUTER LAB

C135

OFFICE

C134

COMMUNICATIONS

C133

STORAGE

C132

WORK

ROOM

C131CONFERENCE

C130

MULTI-PURPOSE

C129

CORRIDOR

C103

CORRIDOR

A124

VESTIBULE

A125

WAITING

A126

RECEPTION

A127

WORK

ROOM

A129

CLOSET

A130

HALLWAY

A131

RECORDS

A133

TLT.

A134

ELEC.

A135

PRINCIPAL

A138

OFFICE

A136

CONFERENCE

A137

KITCHEN

A123

ELEC. EQUIP.

A105

TLT.

A118

OFFICE/

STORAGE

B145

ART ROOM

A140

WARE WASH

A103

RECEIVING

A104

KILN

B145

EL

DB

CM

AC1

T402

EAC3

EA

C3

EA

C3

EAC3

EA

C3

EA

C3

EAC3

EA

C3

EA

C2

EA

C2

EAC2

EAC3

AC

T402

AC3

T402

AC3

T402

AC

T402

EAC3

T402

AC

AC

T402

AC

T402

AC3

T402

AC3

T402

AC

T402

AC

T402

CM9

CM9

EN

C

N

BROWN ES SECURITY PLAN

1/16" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T101

BR

OW

N

ES

S

EC

UR

IT

Y

PL

AN

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

CAMERAS TO BE INSTALLED IN BASEMENT AREAS WITH FOOT TRAFFIC. SHOWN

FOR QUANTIFYING PURPOSES. COORDINATE FINAL LOCATION WITH OWNER.

MOUNT ON SECOND FLOOR EXTERIOR. USE ROUGH-IN FROM DEMOLISHED

CAMERA LOCATION.

MOUNT CAMERA TO UNDER-SIDE OF CATWALK.

EXISTING MAGNETIC LOCKS. CONNECT TO EXISTING DOOR RELEASE BUTTON.

NEW CAMERA TO BE PROCURED AND INSTALLED BY CONTRACTOR.

RE-CABLE DOOR POSITION SENSOR FROM TECH ROOM TO DOOR.

DOOR HAS EXISTING MAG LOCKS. INSTALL NEW MULLION MOUNTED PROXIMITY

READER TO ACTIVATE DOOR.

DOOR TO BE REPLACED BY OWNER. COORDINATE FINAL ACCESS CONTROL

INSTALL WITH OWNER.

INSTALL ONE PROXIMITY READER ON THE OUTSIDE AND INSIDE OF DOOR.

INSTALL BACKERBOARD NEXT TO EXISTING RACK. MAINTAIN PROPER

CLEARANCES.

KEYED NOTES

GENERAL NOTES

1. REUSE EXISTING PENETRATIONS AND ROUGH-INS WHERE POSSIBLE.

2. DISCONNECT ALL EXISTING ACCESS CONTROL DEVICES FROM EXISTING CONTROL

BOARDS AND RECONNECT TO CORRESPONDING PORTS ON NEW CONTROL BOARDS.

RE-CABLE WHERE NEEDED.

3. WHEN RE-CABLING, CABLE TO NEAREST TECH ROOM WITH AN ACCESS CONTROL

ENCLOSURE WITHIN DEVICE'S CABLING ZONE.

4. ALL CAMERAS, THEIR ASSOCIATED MOUNTING HARDWARE, AND LICENSES ARE

PROCURED BY OWNER UNLESS OTHERWISE NOTED. CAMERA LOCATIONS SHOWN AS

BY OWNER REQUIRE LABOR OF INSTALL AND CONFIGURATION ONLY.

5. NEW CAMERA PROCUREMENTS SHALL INCLUDE NECESSARY MOUNTING HARDWARE

AND LICENSES.

6. INSTALL NEW ENCLOSURES ON BACKERBOARDS WITHIN THE FOOTPRINT OF OLD

ENCLOSURES WHERE POSSIBLE. FOLLOW APPLICABLE CLEARANCES AND BEST

PRACTICES.

CABLE TO TC-B

CABLE TO TC-A

CA

BL

E

TO

T C-

B

CA

BL

E

TO

T

C- A

CM1

CM1

CM5

CM5

CM3

CM5

CM9

CM6

CM

CM

CM6

CM4

CM6

CM

CM6 CM6

CM2

CM9

CM3

CM

CM4

CM1 CM5

CM1

CM1

ELDB

MEDIA CENTER

PROJECT LAB

WORK

ROOM

STORAGE

NEWS

STUDIO

OFFICE

COMPUTER LAB

CONF.

STORAGE

CLASSROOM

CLASSROOM

ELEC.

JAN.

RESTROOM

RESTROOM

FOYER

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

101CLASSROOM

100C

CLASSROOM

100B

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

MDF

----OFFICE

COURTYARD

AC1

AC3

EAC3

AC3

T402

EA

C2

EA

C2 AC

AC3

EA

C3

EAC3

EAC3

EA

C3

EAC3

AC3

T402

AC1

T402

AC1

T402

T402

AC1

T402

AC3

T402

AC3

T402

CM9

CM9

AC1

T402

AC1

T402

AC3

T402

ENC

T402

N

E.P. CLARKE ES SECURITY PLAN

3/32" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T102

E.

P.

C

LA

RK

E

ES

S

EC

UR

IT

Y

PL

AN

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

CAMERAS TO BE INSTALLED IN BASEMENT AREAS WITH FOOT TRAFFIC. SHOWN

FOR QUANTIFYING PURPOSES. COORDINATE FINAL LOCATION WITH OWNER.

MOUNT ON SECOND FLOOR EXTERIOR. USE ROUGH-IN FROM DEMOLISHED

CAMERA LOCATION.

MOUNT CAMERA TO UNDER-SIDE OF CATWALK.

EXISTING MAGNETIC LOCKS. CONNECT TO EXISTING DOOR RELEASE BUTTON.

NEW CAMERA TO BE PROCURED AND INSTALLED BY CONTRACTOR.

RE-CABLE DOOR POSITION SENSOR FROM TECH ROOM TO DOOR.

DOOR HAS EXISTING MAG LOCKS. INSTALL NEW MULLION MOUNTED PROXIMITY

READER TO ACTIVATE DOOR.

DOOR TO BE REPLACED BY OWNER. COORDINATE FINAL ACCESS CONTROL

INSTALL WITH OWNER.

INSTALL ONE PROXIMITY READER ON THE OUTSIDE AND INSIDE OF DOOR.

INSTALL BACKERBOARD NEXT TO EXISTING RACK. MAINTAIN PROPER

CLEARANCES.

KEYED NOTES

GENERAL NOTES

1. REUSE EXISTING PENETRATIONS AND ROUGH-INS WHERE POSSIBLE.

2. DISCONNECT ALL EXISTING ACCESS CONTROL DEVICES FROM EXISTING CONTROL

BOARDS AND RECONNECT TO CORRESPONDING PORTS ON NEW CONTROL BOARDS.

RE-CABLE WHERE NEEDED.

3. WHEN RE-CABLING, CABLE TO NEAREST TECH ROOM WITH AN ACCESS CONTROL

ENCLOSURE WITHIN DEVICE'S CABLING ZONE.

4. ALL CAMERAS, THEIR ASSOCIATED MOUNTING HARDWARE, AND LICENSES ARE

PROCURED BY OWNER UNLESS OTHERWISE NOTED. CAMERA LOCATIONS SHOWN AS

BY OWNER REQUIRE LABOR OF INSTALL AND CONFIGURATION ONLY.

5. NEW CAMERA PROCUREMENTS SHALL INCLUDE NECESSARY MOUNTING HARDWARE

AND LICENSES.

6. INSTALL NEW ENCLOSURES ON BACKERBOARDS WITHIN THE FOOTPRINT OF OLD

ENCLOSURES WHERE POSSIBLE. FOLLOW APPLICABLE CLEARANCES AND BEST

PRACTICES.

CM2

CM

CM2

CM4

CM9

CM3

CM5

CM6

CM6

CM

CM6

CM6CM6

CM9CM5

CM2

CM6

CM3

CM1

CM1

CM1

CM1

CM

ELDB

CLASSROOM 104

A124

WORK

ROOM

A122

CLASSROOM 105

A110

CORRIDOR

A102

HALL

A105

PLAYGROUND

EQUIPMENT

A119

EQUIPMENT

A118

CLASSROOM 102

A117

CLASSROOM 107

A115

GIRLS

A114

CORRIDOR

B106

WORK

ROOM

B136

CLASSROOM 108

B134

CLASSROOM 101

B110

SPECIAL ED.

B111

STAGE

B112

GYMNASIUM

B115

CLASSROOM 109

B132

BOYS

B133

UTILITIES

B126

STORAGE

B125

LOUNGE

B124

ENTRANCE

B103

SERVING

B118

UTILITIES

B122

STORAGE

B121

KITCHEN

B119

PRINCIPAL

B128

HALL

B127

TLT.

B129

SECRETARY

B130 VESTIBULE

B100

CORRIDOR

B102

CORRIDOR

B104

MULTI-PURPOSE

B100

VESTIBULE

A100ELEV. EQUIP.

A125

CORRIDOR

A104

STAIRS

A101

STAIRS

A103

STAIRS

B105

WORK

ROOM

A123

CLASSROOM 103

A121

CLASSROOM 106

A113

WORK

ROOM

A112

WORK

ROOM

A111

RESTROOM

A108

TLT.

A109

JANITOR

A107

VEST.

A106

WORK

ROOM

B135

WORK

ROOM

B108

WORK

ROOM

B109

BOILER

ROOM

B113

P.E. STORAGE

B114

TLT.

B120

ALCOVE

B117

FOYER

B101

CONF.

B100

MEDIA

CENTER

B100

OFFICE

B100

WORK

ROOM

B100

STORAGE

B100

COMMUNICATIONS

B100

COMPUTER LAB

AC3

AC

AC1

CM2

EAC3

EAC3

EAC2

EAC2

EAC2

EAC3

EAC3

EAC3

AC

T402

EAC3

T402

AC

T402

AC3

T402

AC

T402

AC

T402

AC

T402

T402

AC1

T402

AC3

T402

AC3

T402

CM3

EN

C

N

LINCOLN ES FIRST FLOOR SECURITY PLAN

1/16" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T103

LIN

CO

LN

E

S

FI

RS

T

FL

OO

R

SE

CU

RI

TY

P

LA

N

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

CAMERAS TO BE INSTALLED IN BASEMENT AREAS WITH FOOT TRAFFIC. SHOWN

FOR QUANTIFYING PURPOSES. COORDINATE FINAL LOCATION WITH OWNER.

MOUNT ON SECOND FLOOR EXTERIOR. USE ROUGH-IN FROM DEMOLISHED

CAMERA LOCATION.

MOUNT CAMERA TO UNDER-SIDE OF CATWALK.

EXISTING MAGNETIC LOCKS. CONNECT TO EXISTING DOOR RELEASE BUTTON.

NEW CAMERA TO BE PROCURED AND INSTALLED BY CONTRACTOR.

RE-CABLE DOOR POSITION SENSOR FROM TECH ROOM TO DOOR.

DOOR HAS EXISTING MAG LOCKS. INSTALL NEW MULLION MOUNTED PROXIMITY

READER TO ACTIVATE DOOR.

DOOR TO BE REPLACED BY OWNER. COORDINATE FINAL ACCESS CONTROL

INSTALL WITH OWNER.

INSTALL ONE PROXIMITY READER ON THE OUTSIDE AND INSIDE OF DOOR.

INSTALL BACKERBOARD NEXT TO EXISTING RACK. MAINTAIN PROPER

CLEARANCES.

KEYED NOTES

GENERAL NOTES

1. REUSE EXISTING PENETRATIONS AND ROUGH-INS WHERE POSSIBLE.

2. DISCONNECT ALL EXISTING ACCESS CONTROL DEVICES FROM EXISTING CONTROL

BOARDS AND RECONNECT TO CORRESPONDING PORTS ON NEW CONTROL BOARDS.

RE-CABLE WHERE NEEDED.

3. WHEN RE-CABLING, CABLE TO NEAREST TECH ROOM WITH AN ACCESS CONTROL

ENCLOSURE WITHIN DEVICE'S CABLING ZONE.

4. ALL CAMERAS, THEIR ASSOCIATED MOUNTING HARDWARE, AND LICENSES ARE

PROCURED BY OWNER UNLESS OTHERWISE NOTED. CAMERA LOCATIONS SHOWN AS

BY OWNER REQUIRE LABOR OF INSTALL AND CONFIGURATION ONLY.

5. NEW CAMERA PROCUREMENTS SHALL INCLUDE NECESSARY MOUNTING HARDWARE

AND LICENSES.

6. INSTALL NEW ENCLOSURES ON BACKERBOARDS WITHIN THE FOOTPRINT OF OLD

ENCLOSURES WHERE POSSIBLE. FOLLOW APPLICABLE CLEARANCES AND BEST

PRACTICES.

CM3

CM3

CM1

CM5

5TH GRADE

A206

WORK

ROOM

A208

4TH GRADE

A221

CORRIDOR

A201

WORK

ROOM

A212

5TH GRADE

A213

4TH GRADE

A215

GIRLS'

A216

CORRIDOR

B200

WORK

ROOM

B211

3RD GRADE

B209

3RD GRADE

B204

UPPER

STAGE

B205

BOYS'

B208

ELEVATOR

A204

STORAGE

A205

STAIRS

A200

STAIRS

A203

STAIRS

B201

WORK

ROOM

A207

4TH GRADE

A209

5TH GRADE

A218

WORK

ROOM

A219

WORK

ROOM

A220

RESTROOM

A222

JAN.

A223

MUSIC ROOM

A211

WORK

ROOM

B210

WORK

ROOM

B203

SPEECH

THERAPY

B207

JAN.

A217

CORRIDOR

A202

CM1

N

LINCOLN ES SECOND FLOOR SECURITY PLAN

1/16" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T104

LIN

CO

LN

E

S

SE

CO

ND

F

LO

OR

S

EC

UR

IT

Y

PL

AN

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

CAMERAS TO BE INSTALLED IN BASEMENT AREAS WITH FOOT TRAFFIC. SHOWN

FOR QUANTIFYING PURPOSES. COORDINATE FINAL LOCATION WITH OWNER.

MOUNT ON SECOND FLOOR EXTERIOR. USE ROUGH-IN FROM DEMOLISHED

CAMERA LOCATION.

MOUNT CAMERA TO UNDER-SIDE OF CATWALK.

EXISTING MAGNETIC LOCKS. CONNECT TO EXISTING DOOR RELEASE BUTTON.

NEW CAMERA TO BE PROCURED AND INSTALLED BY CONTRACTOR.

RE-CABLE DOOR POSITION SENSOR FROM TECH ROOM TO DOOR.

DOOR HAS EXISTING MAG LOCKS. INSTALL NEW MULLION MOUNTED PROXIMITY

READER TO ACTIVATE DOOR.

DOOR TO BE REPLACED BY OWNER. COORDINATE FINAL ACCESS CONTROL

INSTALL WITH OWNER.

INSTALL ONE PROXIMITY READER ON THE OUTSIDE AND INSIDE OF DOOR.

INSTALL BACKERBOARD NEXT TO EXISTING RACK. MAINTAIN PROPER

CLEARANCES.

KEYED NOTES

GENERAL NOTES

1. REUSE EXISTING PENETRATIONS AND ROUGH-INS WHERE POSSIBLE.

2. DISCONNECT ALL EXISTING ACCESS CONTROL DEVICES FROM EXISTING CONTROL

BOARDS AND RECONNECT TO CORRESPONDING PORTS ON NEW CONTROL BOARDS.

RE-CABLE WHERE NEEDED.

3. WHEN RE-CABLING, CABLE TO NEAREST TECH ROOM WITH AN ACCESS CONTROL

ENCLOSURE WITHIN DEVICE'S CABLING ZONE.

4. ALL CAMERAS, THEIR ASSOCIATED MOUNTING HARDWARE, AND LICENSES ARE

PROCURED BY OWNER UNLESS OTHERWISE NOTED. CAMERA LOCATIONS SHOWN AS

BY OWNER REQUIRE LABOR OF INSTALL AND CONFIGURATION ONLY.

5. NEW CAMERA PROCUREMENTS SHALL INCLUDE NECESSARY MOUNTING HARDWARE

AND LICENSES.

6. INSTALL NEW ENCLOSURES ON BACKERBOARDS WITHIN THE FOOTPRINT OF OLD

ENCLOSURES WHERE POSSIBLE. FOLLOW APPLICABLE CLEARANCES AND BEST

PRACTICES.

02 Exist 12

CM9

CM5

TC-B

TC-C

TC-A

TC-E

CABLE TO TC-B

CABLE TO TC-A

CABLE TO TC-B

CABLE TO TC-C

CABLE

TO TC-C

CABLE

TO TC-E

CM

CM3

CM3

CM3

CM3CM3

CM

CM2

CM

CM6

CM1 CM9 CM7

CM9CM5

CM1

CM3

CM2

CM3

CM3

CM1

CM

CM4

CLASSROOM 215

A158

CLASSROOM 217

A157

CLASSROOM 219

A154

CLASSROOM 221

A153

CLASSROOM 223

A150

CLASSROOM 225

A149

SPECIAL ED. 214

A123

SPECIAL ED. 216

A124

CLASSROOM 212

A121

CLASSROOM 213

A120

CLASSROOM 211

A118

CLASSROOM 209

A116

CLASSROOM 203

A110

CLASSROOM 205

A111

CLASSROOM 207

A114

CLASSROOM 210

A130

CLASSROOM 218

A128

OFFICE

A137

CLASSROOM 220

A136

CLASSROOM 204

A144CLASSROOM 226

A146

CLASSROOM 224

A141

CLASSROOM 222

A135

ROOM

A103

CORRIDOR

A111

CORRIDOR

A105

CORRIDOR

A101

VESTIBULE

A100

CORRIDOR

A107

WOMENS

A138

MENS

A134

TLT.

A132

TLT.

A133

ENTRY

A126

ENTRY

A131

ENTRY

A145

STORAGE

A125

STORAGE

A122

STORAGE

A129

STORAGE

A142

CORRIDOR

A104

CORRIDOR

A102

CORRIDOR

A106

STORAGE

A109

STORAGE

A112

STORAGE

A113

STORAGE

A115

STORAGE

A117

STORAGE

A119

STORAGE

A148

STORAGE

A151

STORAGE

A152

STORAGE

A155

STORAGE

A156

STORAGE

A159

STORAGE

A160STORAGE

A161

MEDIA

CENTER

E108

MEDIA

OFFICE

E105

MEDIA

OFFICE

E104

MEDIA

OFFICE

E103

MEDIA

OFFICE

E106

MEDIA

OFFICE

E107

CORRIDOR

E100

TLT.

E101JANITOR

E102

CORRIDOR

B101 CORRIDOR

B100

CORRIDOR

B102

CORRIDOR

B104

CORRIDOR

B103

CORRIDOR

B106

CLASSROOM 405

B142

CLASSROOM 406

B143

KEYBOARD LAB 407

B144

CLASSROOM 311

B146 FOODS 309

B164

CLASSROOM 304

B170

STORAGE 202

B130

CLASSROOM 230

B136

PLANETARIUM

B135

OFFICE

B120

NURSE

B122

CLASSROOM 227

B139

CLASSROOM 229

B140

OFFICE

B141

OFFICE

B138

OFFICE

B147

TLT.

B162

CORRIDOR

B105

COMPUTER

ROOM 313

B148

COMPUTER

ROOM 312

B149

ROOM

B150

ROOM

B163

ROOM 308

B166

ROOM 307

B167

ROOM 306

B168

ROOM 305

B169

OFFICE

B109

OFFICE

B110

OFFICE

B111

OFFICE

B112

OFFICE

B113

OFFICE

B114TLT.

B115

TLT.

B116

TLT.

B117

ROOM

B123

ROOM

B124 ROOM

B121

ROOM

B118

ROOM

B119

ROOM

B132

LOUNGE

B133

ROOM

B134

ROOM

B129

WORK

ROOM

B126

TLT.

B127

TLT.

B128

ROOM

B131

CORRIDOR

D100

MENS

D111

STORAGE

D110

GYM

D112

CLASSROOM 206

A143

SPECIAL ED. 208

A139

AC3

T402

EAC1

EA

C1

EAC3

EAC2

EAC2

EAC2

EAC2

EAC3

ELDB

ELDB

AC1

T402

AC3

T402

AC3

T402

AC3

T402

AC1

T402

AC3

T402

EAC1

EAC1

AC

T402

EAC2

AC

T402

EAC3

AC

T402

CM3

EN

C

EN

C

N

UPTON MS SECURITY PLAN - UNIT A

3/32" = 1'-0"

SHEET NO.

ISSUE / DATE

DRAWN BY

PROJECT NO.

© 2023 AETD, ALL RIGHTS RESERVED.

N

EW

PO

RT

R

OA

D, S

UI

TE

#2

, P

OR

TA

GE

, M I 4

· 2

-2

-2

4 · A

ET

EC

H.

DE

SI

GN

2025-03-10 BIDS

CDB

T105A

UP

TO

N

MS

S

EC

UR

IT

Y

PL

AN

UN

IT

A

SJPS2304-0304

SA

IN

T

JO

SE

PH

, M I

DI

ST

RI

CT

S

EC

UR

IT

Y

IM

PR

OV

EM

EN

TS

SA

IN

T

JO

SE

PH

P

UB

LIC

S

CH

OO

LS

CAMERAS TO BE INSTALLED IN BASEMENT AREAS WITH FOOT TRAFFIC. SHOWN

FOR QUANTIFYING PURPOSES. COORDINATE FINAL LOCATION WITH OWNER.

MOUNT ON SECOND FLOOR EXTERIOR. USE ROUGH-IN FROM DEMOLISHED

CAMERA LOCATION.

MOUNT CAMERA TO UNDER-SIDE OF CATWALK.

EXISTING MAGNETIC LOCKS. CONNECT TO EXISTING DOOR RELEASE BUTTON.

NEW CAMERA TO BE PROCURED AND INSTALLED BY CONTRACTOR.

RE-CABLE DOOR POSITION SENSOR FROM TECH ROOM TO DOOR.

DOOR HAS EXISTING MAG LOCKS. INSTALL NEW MULLION MOUNTED PROXIMITY

READER TO ACTIVATE DOOR.

DOOR TO BE REPLACED BY OWNER. COORDINATE FINAL ACCESS CONTROL

INSTALL WITH OWNER.

INSTALL ONE PROXIMITY READER ON THE OUTSIDE AND INSIDE OF DOOR.

INSTALL BACKERBOARD NEXT TO EXISTING RACK. MAINTAIN PROPER

CLEARANCES.

KEYED NOTES

GENERAL NOTES

1. REUSE EXISTING PENETRATIONS AND ROUGH-INS WHERE POSSIBLE.

2. DISCONNECT ALL EXISTING ACCESS CONTROL DEVICES FROM EXISTING CONTROL

BOARDS AND RECONNECT TO CORRESPONDING PORTS ON NEW CONTROL BOARDS.

RE-CABLE WHERE NEEDED.

3. WHEN RE-CABLING, CABLE TO NEAREST TECH ROOM WITH AN ACCESS CONTROL

ENCLOSURE WITHIN DEVICE'S CABLING ZONE.

4. ALL CAMERAS, THEIR ASSOCIATED MOUNTING HARDWARE, AND LICENSES ARE

PROCURED BY OWNER UNLESS OTHERWISE NOTED. CAMERA LOCATIONS SHOWN AS

BY OWNER REQUIRE LABOR OF INSTALL AND CONFIGURATION ONLY.

5. NEW CAMERA PROCUREMENTS SHALL INCLUDE NECESSARY MOUNTING HARDWARE

AND LICENSES.

6. INSTALL NEW ENCLOSURES ON BACKERBOARDS WITHIN THE FOOTPRINT OF OLD

ENCLOSURES WHERE POSSIBLE. FOLLOW APPLICABLE CLEARANCES AND BEST

PRACTICES.

CM9

CM5

TC-A

TC-E

TC-D

CABLE TO TC-D

CABLE TO TC-A

CA

BL

E

TO

T C-

E

CA

BL

E

TO

T

C- A

CABLE TO TC-D

CABLE…