Sign Shop Window Replacement Project Manual.pdf
PDF 853 KB Posted
- Attached to
- Ames Campus: Sign Shop Windows
- Solicitation number
- 645-RFB-2149-2026
- Issued by
- Story County, Iowa
About this file
Sign Shop Window Replacement Project Manual – Standard Material Specifications
This is a comprehensive project manual containing standard material specifications for the Iowa Department of Transportation's Ames Campus Sign Shop Windows renovation project (RFB Number 645-RFB-2149-2026). The specifications document outlines detailed requirements for cold-formed metal framing, rough carpentry, thermal insulation, fiber-cement siding, joint sealants, hollow metal doors and frames, aluminum windows, door hardware, glazing, gypsum board assemblies, and exterior and interior painting. The project scope includes comprehensive renovation work involving removal of existing wall and window materials and replacement with new wall framing, sheathing, siding, and windows. The solicitation period runs from October 1, 2025, to October 29, 2025, with bid opening scheduled for 1:00 PM CDT. The project is scheduled to commence on December 1, 2025, with an expected completion date of June 30, 2026. Site visits are optional and can be arranged by contacting Kyle Williams with 24-hour advance notice. Bidders must provide detailed documentation on fabricated materials, lead times, and project timelines.
The specifications establish minimum material standards and installation procedures across all construction disciplines, with reference to industry standards including AISI, ASTM, AAMA, BHMA, and ICC guidelines. Material requirements include galvanized cold-formed steel studs, Douglas Fir lumber, fiber-cement siding with 50-year limited transferable warranty, thermally insulated hollow metal doors with polyurethane core, aluminum windows with high-performance powder coatings and field testing requirements, and various accessories meeting corrosion resistance standards. The project requires performance and payment bonds for contracts exceeding $25,000, and bidders must be registered with the Iowa Department of Workforce Development. Evaluation criteria include cost, proposed staffing, time schedule, past work performance, and overall work capacity. Deliveries are designated F.O.B. Destination with the agency maintaining tax-exempt status. While no specific budget range was provided in the specifications, the comprehensive scope and detailed technical requirements indicate a significant capital investment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1341581-event.pdf | ||
| A101_2017 sample.pdf | ||
| Sign Shop Windows - Plans.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
0-Standard Material Specifications - 1219 11-Sep-2025
Page
Cold-Formed Metal Framing 05 4000
SECTION 05 4000
COLD-FORMED METAL FRAMING
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Formed steel stud exterior wall framing.
1.02 REFERENCE STANDARDS
A. AISI S100 - North American Specification for the Design of Cold-Formed Steel Structural Members; 2016, with Supplement (2020).
B. ASCE 7 - Minimum Design Loads and Associated Criteria for Buildings and Other Structures;
Most Recent Edition Cited by Referring Code or Reference Standard.
C. ASTM A153/A153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware; 2023.
D. ASTM A780/A780M - Standard Practice for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized Coatings; 2020.
E. ASTM C1007 - Standard Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories; 2020 (Reapproved 2024).
F. ICC (IBC) - International Building Code; Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements.
G. SSPC-Paint 20 - Zinc-Rich Coating (Type I - Inorganic, and Type II - Organic); 2019.
1.03 SUBMITTALS
A. See Section 01 3000 - Administrative Requirements for submittal procedures.
B. Product Data: Provide data on standard framing members; describe materials and finish, product criteria, limitations.
1.04 QUALITY ASSURANCE
A. Designer Qualifications: Design framing system under direct supervision of a professional structural engineer experienced in designing this work and licensed in the State in which the Project is located.
B. Installer Qualifications: Company specializing in performing the work of this section with minimum three years documented experience and approved by manufacturer.
PART 2 PRODUCTS
2.01 PERFORMANCE REQUIREMENTS
A. Design Requirements: Design cold-formed framing systems, components and connectors to withstand specified design loads in compliance with ICC (IBC), ASCE 7, AISI S100, and AISI S240.
2.02 MATERIALS
A. Steel Sheet: ASTM A1003/A1003M, subject to the ductility limitations indicated in AISI S240.
2.03 STRUCTURAL FRAMING COMPONENTS
A. Wall Studs and Track Sections: AISI S240; c-shaped studs and u-shaped track sections in stud-matching nominal width and compatible height.
1. Structural Grade: As required to meet design criteria.
B. Headers: AISI S240; manufactured, engineered one-member or two-member assemblies, with wide flanges, designed to replace conventional box or nested header framing at openings.
1. Jamb Mounting Clips: Manufacturer's standard.
asmelse Rectangle
Page
Cold-Formed Metal Framing 05 4000
2.04 MISCELLANEOUS CONNECTIONS
A. Self-Drilling, Self-Tapping Screws, Bolts, Nuts and Washers: Hot-dip galvanized per ASTM
A153/A153M.
2.05 ACCESSORIES
A. Galvanizing Repair: Touch up bare steel with zinc-rich paint in compliance with ASTM A780/A780M.
B. Touch-Up Primer for Galvanized Surfaces: SSPC-Paint 20 Type I - Inorganic, complying with VOC limitations of authorities having jurisdiction.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify that substrate surfaces are ready to receive work.
3.02 INSTALLATION - GENERAL
A. Install structural members and connections in compliance with ASTM C1007.
3.03 INSTALLATION OF STUDS
A. Install wall studs plumb and level.
B. Install load-bearing studs full length in one piece. Splicing of studs is not permitted.
C. Provide deflection allowance in stud track, directly below horizontal building framing at non-loadbearing framing.
D. Touch-up field welds and damaged corrosion-protected surfaces zinc-rich paint in compliance with ASTM A780/A780M.
E. Touch-up field welds and damaged corrosion protected surfaces with primer.
3.04 FIELD QUALITY CONTROL
A. See Section 01 4000 - Quality Requirements, for additional requirements.
B. Provide material verification inspections in accordance with requirements of AISI S240.
3.05 TOLERANCES
A. Studs - Vertical Alignment (Plumbness): 1/960 of span or 1/8 inch in 10 ft, in accordance with
ASTM C1007.
END OF SECTION
Page
Rough Carpentry 06 1000
SECTION 06 1000
ROUGH CARPENTRY
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Rough opening framing for doors, windows, and roof openings.
B. Concealed wood blocking, nailers, and supports.
C. Miscellaneous wood nailers, furring, and grounds.
1.02 REFERENCE STANDARDS
A. ANSI A208.1 - American National Standard for Particleboard; 2022.
B. ASTM A153/A153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel
Hardware; 2023.
C. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials;
2024.
D. AWPA U1 - Use Category System: User Specification for Treated Wood; 2025.
E. ICC-ES AC38 - Acceptance Criteria for Water-Resistive Barriers; 2016, with Editorial Revision
(2021).
F. PS 1 - Structural Plywood; 2023.
G. PS 2 - Performance Standard for Wood Structural Panels; 2019.
H. PS 20 - American Softwood Lumber Standard; 2025.
I. SPIB (GR) - Standard Grading Rules; 2021.
J. WWPA G-5 - Western Lumber Grading Rules; 2025.
1.03 SUBMITTALS
A. Product Data: Provide technical data on insulated sheathing and application instructions.
B. Warranty Documentation: Submit manufacturer warranty and ensure that forms have been completed in Owner's name and registered with manufacturer.
1.04 DELIVERY, STORAGE, AND HANDLING
A. General: Cover wood products to protect against moisture. Support stacked products to prevent deformation and to allow air circulation.
PART 2 PRODUCTS
2.01 GENERAL REQUIREMENTS
A. Dimension Lumber: Comply with PS 20 and requirements of specified grading agencies.
1. Species: Douglas Fir-Larch, unless otherwise indicated.
2. If no species is specified, provide species graded by the agency specified; if no grading agency is specified, provide lumber graded by grading agency meeting the specified requirements.
3. Grading Agency: Grading agency whose rules are approved by the Board of Review, American Lumber Standard Committee at www.alsc.org, and who provides grading service for the species and grade specified; provide lumber stamped with grade mark unless otherwise indicated.
4. Lumber of other species or grades is acceptable provided structural and appearance characteristics are equivalent to or better than products specified.
B. Provide sustainably harvested wood; see Section 01 6000 - Product Requirements for requirements.
2.02 DIMENSION LUMBER FOR CONCEALED APPLICATIONS
A. Grading Agency: Southern Pine Inspection Bureau, Inc; SPIB (GR).
Page
Rough Carpentry 06 1000
B. Sizes: Nominal sizes as indicated on drawings, S4S.
C. Moisture Content: S-dry or MC19.
D. Stud Framing (2 by 2 through 2 by 6 ):
1. Grade: No. 2.
E. Miscellaneous Framing, Blocking, Nailers, Grounds, and Furring:
1. Lumber: S4S, No. 2 or Standard Grade.
2. Boards: Standard or No. 3.
2.03 CONSTRUCTION PANELS
A. Wall Sheathing: Plywood, PS 1, Grade C-D, Exposure I.
2.04 ACCESSORIES
A. Metal and Finish of Fasteners:
1. Untreated Wood: Unfinished steel.
B. Fasteners and Anchors:
1. Metal and Finish: Hot-dipped galvanized steel complying with ASTM A153/A153M for high humidity and preservative-treated wood locations, unfinished steel elsewhere.
2. Anchors: Toggle bolt type for anchorage to hollow masonry.
3. Nails, Brads and Staples: ASTM F 1667.
4. Power-Driven Fasteners: NES NER-272.
5. Wood Screws: ASME B18.6.1.
C. Die-Stamped Connectors: Hot dipped galvanized steel, sized to suit framing conditions.
PART 3 EXECUTION
3.01 INSTALLATION - GENERAL
A. Select material sizes to minimize waste.
B. Reuse scrap to the greatest extent possible; clearly separate scrap for use on site as accessory components, including: shims, bracing, and blocking.
3.02 INSTALLATION OF CONSTRUCTION PANELS
A. Wall Sheathing: Secure with long dimension perpendicular to wall studs, with ends over firm bearing and staggered, using nails, screws, or staples.
1. Install plywood wall sheathing in accordance with manufacturer's current ICC-ES evaluation report for specified sheathing product.
3.03 TOLERANCES
A. Framing Members: 1/4 inch from true position, maximum.
B. Variation from Plane, Other than Floors: 1/4 inch in 10 feet maximum, and 1/4 inch in 30 feet maximum.
3.04 CLEANING
A. Do not leave wood, shavings, sawdust, etc. on the ground or buried in fill.
B. Prevent sawdust and wood shavings from entering the storm drainage system.
END OF SECTION
Page
Thermal Insulation 07 2100
SECTION 07 2100
THERMAL INSULATION
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Board insulation at perimeter foundation wall.
B. Batt insulation in exterior wall construction.
C. Batt insulation for filling perimeter window and door shim spaces.
1.02 REFERENCE STANDARDS
A. ASTM C553 - Standard Specification for Mineral Fiber Blanket Thermal Insulation for
Commercial and Industrial Applications; 2024.
B. ASTM C665 - Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light
Frame Construction and Manufactured Housing; 2024.
C. ASTM C1289 - Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal
Insulation Board; 2025.
D. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials;
2024.
E. ASTM E136 - Standard Test Method for Assessing Combustibility of Materials Using a Vertical
Tube Furnace at 750 Degrees C; 2024c.
1.03 SUBMITTALS
A. Product Data: Provide data on product characteristics, performance criteria, and product limitations.
1.04 FIELD CONDITIONS
A. Do not install insulation adhesives when temperature or weather conditions are detrimental to successful installation.
PART 2 PRODUCTS
2.01 APPLICATIONS
A. Insulation on Inside of Framed Walls with Exposed Facer Providing Interior Finish: Rigid cellular polyisocyanurate with exposed facers.
B. Insulation in Metal Framed Walls: Batt insulation with no vapor retarder.
2.02 FOAM BOARD INSULATION MATERIALS
A. Rigid Cellular Polyisocyanurate (ISO) Thermal Insulation Board with Facers Both Sides and Providing Interior Finish System: Complying with ASTM C1289.
1. Compressive Strength: 16 psi, minimum.
2. Thermal Resistance, R-value: Type I, Class 2, at 1-1/2 inch thick; 9.0, minimum, at 75 degrees F.
3. Flame Spread Index (FSI): Class A - 0 to 25, when tested in accordance with ASTM E84.
4. Smoke Developed Index (SDI): 450 or less, when tested in accordance with ASTM E84.
5. Board Size: 48 inch by 96 inch.
6. Board Thickness: 1 inch.
7. Board Edges: Square.
8. Exposed Facer: 4 mil, 0.004 inch embossed white thermoset-coated aluminum.
9. Non-Exposed Facer: 1.25 mil, 0.00125 inch embossed aluminum.
2.03 MINERAL FIBER BLANKET INSULATION MATERIALS
A. Flexible Glass Fiber Blanket Thermal Insulation: Preformed insulation, complying with ASTM
C665; friction fit.
1. Flame Spread Index: 75 or less, when tested in accordance with ASTM E84.
Page
Thermal Insulation 07 2100
2. Smoke Developed Index: 450 or less, when tested in accordance with ASTM E84.
3. Combustibility: Non-combustible, when tested in accordance with ASTM E136, except for facing, if any.
2.04 ACCESSORIES
A. Sill Plate Sealer: Closed-cell foam tape with rubberized adhesive membrane; bridges gap between foundation structure and sill plate or skirt board.
1. Width: 3-1/2 inches.
2. Ultraviolet (UV) and Weathering Resistance: Approved in writing by manufacturer for up to 30 days of weather exposure.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify that substrate, adjacent materials, and insulation materials are dry and that substrates are ready to receive insulation.
B. Verify substrate surfaces are flat, free of honeycomb, fins, irregularities, or materials or substances that may impede adhesive bond.
3.02 BATT INSTALLATION
A. Install insulation and vapor retarder in accordance with manufacturer's instructions.
B. Install in exterior wall and roof spaces without gaps or voids. Do not compress insulation.
C. Trim insulation neatly to fit spaces. Insulate miscellaneous gaps and voids.
D. Fit insulation tightly in cavities and tightly to exterior side of mechanical and electrical services within the plane of the insulation.
END OF SECTION
Page
Fiber-Cement Siding 07 4646
SECTION 07 4646
FIBER-CEMENT SIDING
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Fiber-cement siding.
1.02 RELATED REQUIREMENTS
1.03 REFERENCE STANDARDS
A. ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc- Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process; 2023.
B. ASTM C1186 - Standard Specification for Flat Fiber-Cement Sheets; 2022, with Editorial Revision (2023).
C. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials;
2024.
D. ASTM E136 - Standard Test Method for Assessing Combustibility of Materials Using a Vertical Tube Furnace at 750 Degrees C; 2024c.
1.04 SUBMITTALS
A. Product Data: Submit manufacturer's data sheets on each product to be used, including:
1. Manufacturer's requirements for related materials to be installed by others.
2. Preparation instructions and recommendations.
3. Storage and handling requirements and recommendations.
4. Installation methods, including nail patterns.
B. Manufacturer's qualification statement.
C. Installer's qualification statement.
1.05 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this section, with not less than five years of documented experience.
B. Installer Qualifications: Company specializing in performing work of type specified in this section with not less than three years of experience.
1.06 DELIVERY, STORAGE, AND HANDLING
A. Deliver and store materials in manufacturer's unopened packaging, with labels intact, until ready for installation.
B. Store materials under dry and waterproof cover, well ventilated, and elevated above grade on a flat surface.
C. Protect materials from harmful environmental elements, construction dust, and other potentially detrimental conditions.
1.07 FIELD CONDITIONS
A. Do not install panels when air temperature or relative humidity are outside manufacturer's limits.
PART 2 PRODUCTS
2.01 FIBER-CEMENT SIDING
A. Panel Siding: Vertically oriented panels made of cement and cellulose fiber formed under high pressure with integral surface texture, complying with ASTM C1186, Type A, Grade II; with machined edges, for nail attachment.
1. Length (Height): 96 inches, nominal.
2. Width: 48 inches.
3. Thickness: 5/16 inch, nominal.
Page
Fiber-Cement Siding 07 4646
4. Finish: Factory applied stain.
5. Color: As selected by Architect from manufacturers full range of available colors.
6. Warranty: 50 year limited; transferable.
2.02 ACCESSORIES
A. Support for Cladding and Continuous Insulation: Thermal clips.
1. Thermally-broken clips that provide attachment support for girts, angles, channels, and other cladding support framing.
2. Galvanized Steel Support Clip: 14 gauge, 0.0747 inch, G90/Z275 galvanized support clip complying with ASTM A653/A653M, with integral glass fiber reinforced polyamide thermal isolator pad.
3. Clip Depth: As required for thickness of insulation.
4. Fasteners: As recommended by clip manufacturer.
B. Trim: Same material and texture as siding.
C. Fasteners: Galvanized or corrosion resistant; length as required to penetrate, 1-1/4 inches, minimum.
PART 3 EXECUTION
3.01 EXAMINATION
A. Examine substrate, clean and repair as required to eliminate conditions that would be detrimental to proper installation.
B. Do not begin until unacceptable conditions have been corrected.
C. If substrate preparation is responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
3.02 PREPARATION
A. Protect surrounding areas and adjacent surfaces during execution of this work.
3.03 INSTALLATION
A. Install siding in accordance with manufacturer's instructions and recommendations.
1. Read warranty and comply with terms necessary to maintain warranty coverage.
2. Use trim details as indicated on drawings.
3. Touch up field cut edges before installing.
4. Pre-drill nail holes if necessary to prevent breakage.
B. Joints in Vertical Siding: Install Z-flashing in horizontal joints between successive courses of vertical siding.
C. Do not install siding less than 6 inches from ground surface, or closer than 1 inch to roofs, patios, porches, and other surfaces where water may collect.
D. After installation, seal joints except lap joints of lap siding; seal around penetrations, and paint exposed cut edges.
3.04 CLEANING
A. Clean faced panels in accordance with manufacturer’s maintenance instructions, using cleaning materials and methods acceptable to manufacturer.
3.05 PROTECTION
A. Protect installed products until Date of Substantial Completion.
B. Touch-up, repair or replace damaged products before Date of Substantial Completion.
END OF SECTION
Page
Joint Sealants 07 9200
SECTION 07 9200
JOINT SEALANTS
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Nonsag gunnable joint sealants.
B. Joint backings and accessories.
1.02 REFERENCE STANDARDS
A. ASTM C834 - Standard Specification for Latex Sealants; 2017 (Reapproved 2023).
B. ASTM C919 - Standard Practice for Use of Sealants in Acoustical Applications; 2024.
C. ASTM C1193 - Standard Guide for Use of Joint Sealants; 2025.
D. ASTM C1330 - Standard Specification for Cylindrical Sealant Backing for Use with Cold Liquid-
Applied Sealants; 2023.
E. ASTM D695 - Standard Test Method for Compressive Properties of Rigid Plastics; 2023.
F. SCAQMD 1168 - Adhesive and Sealant Applications; 1989, with Amendment (2022).
1.03 SUBMITTALS
A. Product Data: Submit manufacturer's technical datasheets for each product to be used; include the following:
1. Physical characteristics, including movement capability, VOC content, hardness, cure time, and color availability.
2. List of backing materials approved for use with the specific product.
3. Substrates that product is known to satisfactorily adhere to and with which it is compatible.
4. Substrates the product should not be used on.
5. Substrates for which use of primer is required.
6. Installation instructions, including precautions, limitations, and recommended backing materials and tools.
B. Color Cards for Selection: Where sealant color is not specified, submit manufacturer's color cards showing standard colors available for selection.
C. Executed warranty.
1.04 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing the products specified in this section with minimum three years documented experience.
B. Installer Qualifications: Company specializing in performing the work of this section and with at least three years of documented experience.
1.05 WARRANTY
A. Manufacturer Warranty: Provide 2-year manufacturer warranty for installed sealants and accessories that fail to achieve a watertight seal, exhibit loss of adhesion or cohesion, or do not cure. Complete forms in Owner's name and register with manufacturer.
B. Extended Correction Period: Correct defective work within 2-year period commencing on Date of Substantial Completion.
PART 2 PRODUCTS
2.01 JOINT SEALANT APPLICATIONS
A. Scope:
1. Exterior Joints:
a. Seal the following joints:
1) Joints between doors, windows, and other frames or adjacent construction.
2. Interior Joints:
Page
Joint Sealants 07 9200
a. Seal the following joints:
1) Joints between window frames and adjacent construction.
3. Interior Joints: Do not seal interior joints unless specifically indicated to be sealed. Interior joints to be sealed include, but are not limited to, the following items.
a. Joints between door, window, and other frames and adjacent construction.
b. Other joints indicated below.
B. Type Ext-1 - Exterior Joints: Use non-sag non-staining silicone sealant, unless otherwise indicated.
C. Type Int-1 - Interior Joints: Use non-sag Acrylic emulsion, paintable, latex sealant, unless otherwise indicated.
1. Type Int-1 - Wall and Ceiling Joints in Non-Wet Areas: Acrylic emulsion latex sealant.
2.02 ACCESSORIES
A. Sealant Backing Rod, Closed-Cell Type:
1. Cylindrical flexible sealant backings complying with ASTM C1330 Type C.
2. Size: 25 to 50 percent larger in diameter than joint width.
B. Masking Tape: Self-adhesive, nonabsorbent, nonstaining, removable without adhesive residue, and compatible with surfaces adjacent to joints and sealants.
C. Joint Cleaner: Noncorrosive and nonstaining type, type recommended by sealant manufacturer; compatible with joint forming materials.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify that joints are ready to receive work.
B. Verify that backing materials are compatible with sealants.
C. Verify that backer rods are of the correct size.
3.02 PREPARATION
A. Remove loose materials and foreign matter that could impair adhesion of sealant.
B. Clean joints, and prime as necessary, in accordance with manufacturer's instructions.
C. Perform preparation in accordance with manufacturer's instructions and ASTM C1193.
D. Mask elements and surfaces adjacent to joints from damage and disfigurement due to sealant work; be aware that sealant drips and smears may not be completely removable.
3.03 INSTALLATION
A. Install this work in accordance with sealant manufacturer's requirements for preparation of surfaces and material installation instructions.
B. Provide joint sealant installations complying with ASTM C1193.
C. Measure joint dimensions and size joint backers to achieve width-to-depth ratio, neck dimension, and surface bond area as recommended by manufacturer.
D. Install bond breaker backing tape where backer rod cannot be used.
E. Install sealant free of air pockets, foreign embedded matter, ridges, and sags, and without getting sealant on adjacent surfaces.
F. Do not install sealant when ambient temperature is outside manufacturer's recommended temperature range, or will be outside that range during the entire curing period, unless manufacturer's approval is obtained and instructions are followed.
G. Nonsag Sealants: Tool surface concave, unless otherwise indicated; remove masking tape immediately after tooling sealant surface.
H. Concrete Floor Joint Filler: After full cure, shave joint filler flush with top of concrete slab.
Page
Joint Sealants 07 9200
3.04 FIELD QUALITY CONTROL
A. Remove and replace failed portions of sealants using same materials and procedures as indicated for original installation.
END OF SECTION
Page
Hollow Metal Doors and Frames 08 1113
SECTION 08 1113
HOLLOW METAL DOORS AND FRAMES
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Non-fire-rated hollow metal doors and frames.
1.02 ABBREVIATIONS AND ACRONYMS
A. ANSI: American National Standards Institute.
B. HMMA: Hollow Metal Manufacturers Association.
C. NFPA: National Fire Protection Association.
D. SDI: Steel Door Institute.
E. UL: Underwriters Laboratories.
1.03 REFERENCE STANDARDS
A. ADA Standards - 2010 ADA Standards for Accessible Design; 2010.
B. ANSI/SDI A250.3 - Test Procedure and Acceptance Criteria for Factory Applied Finish Coatings for Steel Doors and Frames; 2025.
C. ANSI/SDI A250.4 - Test Procedure and Acceptance Criteria for Physical Endurance for Steel
Doors, Frames and Frame Anchors; 2024.
D. ANSI/SDI A250.8 - Specifications for Standard Steel Doors and Frames (SDI-100); 2023.
E. ANSI/SDI A250.10 - Test Procedure and Acceptance Criteria for Prime Painted Steel Surfaces for Steel Doors and Frames; 2025.
F. ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-
Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process; 2023.
G. ASTM A1008/A1008M - Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Required Hardness, Solution Hardened, and Bake Hardenable; 2024.
H. ASTM A1011/A1011M - Standard Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength; 2023.
I. BHMA A156.115 - Hardware Preparation in Steel Doors and Frames; 2016.
J. ICC A117.1 - Accessible and Usable Buildings and Facilities; 2017.
K. NAAMM HMMA 830 - Hardware Selection for Hollow Metal Doors and Frames; 2002.
L. NAAMM HMMA 831 - Hardware Locations for Hollow Metal Doors and Frames; 2024.
M. NAAMM HMMA 840 - Guide Specifications for Receipt, Storage and Installation of Hollow Metal
Doors and Frames; 2024.
N. NAAMM HMMA 861 - Guide Specifications for Commercial Hollow Metal Doors and Frames;
2014.
O. SDI 117 - Manufacturing Tolerances for Standard Steel Doors and Frames; 2023.
1.04 SUBMITTALS
A. Product Data: Materials and details of design and construction, hardware locations, reinforcement type and locations, anchorage and fastening methods, and finishes.
B. Shop Drawings: Details of each opening, showing elevations, glazing, frame profiles, and any indicated finish requirements.
C. Color selection chart ( provide 1 original paper copy and 1 PDF copy), showing factory finishes, colors, and surface texture.
Page
Hollow Metal Doors and Frames 08 1113
D. Installation Instructions: Manufacturer's published instructions, including any special installation instructions relating to this project.
1.05 QUALITY ASSURANCE
A. Manufacturer Qualifications: Provide hollow metal doors and frames from SDI Certified manufacturer: https://steeldoor.org/sdi-certified/#sle.
B. Installer Qualifications: Company specializing in performing work of the type specified and with at least three years of documented experience.
C. Maintain at project site copies of reference standards relating to installation of products specified.
1.06 DELIVERY, STORAGE, AND HANDLING
A. Comply with NAAMM HMMA 840 or ANSI/SDI A250.8 (SDI-100) in accordance with specified requirements.
B. Protect with resilient packaging; avoid humidity build-up under coverings; prevent corrosion and adverse effects on factory applied painted finish.
PART 2 PRODUCTS
2.01 PERFORMANCE REQUIREMENTS
A. Requirements for Hollow Metal Doors and Frames:
1. Steel Sheet: Comply with one or more of the following requirements; galvannealed steel complying with ASTM A653/A653M, cold-rolled steel complying with ASTM A1008/A1008M, or hot-rolled pickled and oiled (HRPO) steel complying with ASTM A1011/A1011M, commercial steel (CS) Type B, for each.
2. Accessibility: Comply with ICC A117.1 and ADA Standards.
3. Door Top Closures: Flush end closure channel, with top and door faces aligned.
4. Door Edge Profile: Manufacturers standard for application indicated.
5. Typical Door Face Sheets: Flush.
6. Glazed Lights: Non-removable stops on non-secure side; sizes and configurations as indicated on drawings. Style: Manufacturer's standard.
7. Hardware Preparations, Selections and Locations: Comply with NAAMM HMMA 830 and
NAAMM HMMA 831 or BHMA A156.115 and ANSI/SDI A250.8 (SDI-100) in accordance with specified requirements.
8. Zinc Coating for Typical Interior and/or Exterior Locations: Provide metal components zinc-coated (galvanized) and/or zinc-iron alloy-coated (galvannealed) by the hot-dip process in accordance with ASTM A653/A653M, with manufacturer's standard coating thickness, unless noted otherwise for specific hollow metal doors and frames.
a. Based on SDI Standards: Provide at least A40/ZF120 (galvannealed) when necessary, coating not required for typical interior door applications, and at least A60/ZF180 (galvannealed) for corrosive locations.
B. Combined Requirements: If a particular door and frame unit is indicated to comply with more than one type of requirement, comply with the specified requirements for each type; for instance, an exterior door that is also indicated as being sound-rated must comply with the requirements specified for exterior doors and for sound-rated doors; where two requirements conflict, comply with the most stringent.
2.02 HOLLOW METAL DOORS
A. Type ___ , Exterior Doors: Thermally insulated.
1. Based on SDI Standards: ANSI/SDI A250.8 (SDI-100).
a. Level 1 - Standard-duty.
b. Physical Performance Level C, 250,000 cycles; in accordance with ANSI/SDI A250.4.
c. Model 1 - Full Flush.
d. Door Face Metal Thickness: 20 gauge, 0.032 inch, minimum.
e. Zinc Coating: A60/ZF180 galvannealed coating; ASTM A653/A653M.
Page
Hollow Metal Doors and Frames 08 1113
2. Door Core Material: Polyurethane, 1.8 lbs/cu ft minimum density.
3. Door Thermal Resistance: R-Value of 8.7, minimum, for installed thickness of polyurethane.
4. Door Thickness: 1-3/4 inches, nominal.
5. Weatherstripping: Refer to Section 08 7100.
2.03 HOLLOW METAL FRAMES
A. Comply with standards and/or custom guidelines as indicated for corresponding door in accordance with applicable door frame requirements.
B. Exterior Door Frames: Full profile/continuously welded type.
1. Galvanizing: Components hot-dipped zinc-iron alloy-coated (galvannealed) in accordance with ASTM A653/A653M, with A40/ZF120 coating.
2. Frame Metal Thickness: 16 gage, 0.053 inch, minimum.
3. Frame Finish: Factory finished.
4. Weatherstripping: Separate, see Section 08 7100.
5. Thermal break: NFRC 102, U-Value of 0.36.
2.04 FINISHES
A. Primer: Rust-inhibiting, complying with ANSI/SDI A250.10, door manufacturer's standard.
B. Factory Finish: Complying with ANSI/SDI A250.3, manufacturer's standard coating.
1. Color: As selected by Architect from manufacturer's standard range.
2.05 ACCESSORIES
A. Glazing: As specified in Section 08 8000, factory installed.
B. Silencers: Resilient rubber, fitted into drilled hole; provide three on strike side of single door, three on center mullion of pairs, and two on head of pairs without center mullions.
C. Temporary Frame Spreaders: Provide for factory- or shop-assembled frames.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify existing conditions before starting work.
B. Verify that opening sizes and tolerances are acceptable.
C. Verify that finished walls are in plane to ensure proper door alignment.
3.02 PREPARATION
A. Coat inside of frames to be installed in masonry or to be grouted, with bituminous coating, prior to installation.
3.03 INSTALLATION
A. Install doors and frames in accordance with manufacturer's instructions and related requirements of specified door and frame standards or custom guidelines indicated.
B. Coordinate frame anchor placement with wall construction.
C. Comply with glazing installation requirements of Section 08 8000.
D. Touch up damaged factory finishes.
3.04 TOLERANCES
A. Clearances Between Door and Frame: Comply with related requirements of specified frame standards or custom guidelines indicated in accordance with SDI 117 or NAAMM HMMA 861.
B. Maximum Diagonal Distortion: 1/16 inch measured with straight edge, corner to corner.
3.05 ADJUSTING
A. Adjust for smooth and balanced door movement.
Page
Hollow Metal Doors and Frames 08 1113
B. Adjust sound control doors so that seals are fully engaged when door is closed.
END OF SECTION
Page
Aluminum Windows 08 5113
SECTION 08 5113
ALUMINUM WINDOWS
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Extruded aluminum windows with operating sash.
B. Factory glazing.
C. Operating hardware.
D. Insect screens.
1.02 REFERENCE STANDARDS
A. AAMA/WDMA/CSA 101/I.S.2/A440 - North American Fenestration Standard/Specification for
Windows, Doors, and Skylights; 2022, with Errata (2023).
B. AAMA CW-10 - Care and Handling of Architectural Aluminum from Shop to Site; 2015.
C. AAMA 502 - Voluntary Specification for Field Testing of Newly Installed Fenestration Products;
2021.
D. AAMA 609 & 610 - Cleaning and Maintenance Guide for Architecturally Finished Aluminum;
2025.
E. AAMA 1503 - Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors and Glazed Wall Sections; 2009.
F. AAMA 2603 - Voluntary Specification, Performance Requirements and Test Procedures for
Pigmented Organic Coatings on Aluminum Extrusions and Panels (with Coil Coating Appendix);
2022.
G. AAMA 2604 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels (with Coil Coating Appendix); 2022.
H. ASCE 7 - Minimum Design Loads and Associated Criteria for Buildings and Other Structures;
Most Recent Edition Cited by Referring Code or Reference Standard.
I. ASHRAE Std 90.1 I-P - Energy Standard for Buildings Except Low-Rise Residential Buildings;
Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements.
J. ASTM B209/B209M - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate; 2021a.
K. ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes; 2021.
L. ASTM B221M - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric); 2021.
M. ASTM E283/E283M - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Skylights, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen; 2019.
N. ASTM E331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference; 2000 (Reapproved 2023).
O. ASTM E783 - Standard Test Method for Field Measurement of Air Leakage Through Installed Exterior Windows and Doors; 2002 (Reapproved 2018).
P. ASTM E1105 - Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference; 2015 (Reapproved 2023).
Page
Aluminum Windows 08 5113
Q. ASTM E1996 - Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes; 2023.
R. ASTM E2112 - Standard Practice for Installation of Exterior Windows, Doors and Skylights;
2023.
1.03 SUBMITTALS
A. Product Data: Include component dimensions, information on glass and glazing, internal drainage details, and descriptions of hardware and accessories.
B. Shop Drawings: Indicate opening dimensions, elevations of different types, framed opening tolerances, anchorage locations, and installation requirements.
C. Grade Substantiation: Prior to submitting shop drawings or starting fabrication, submit one of the following showing compliance with specified grade:
1. Evidence of AAMA Certification.
2. Evidence of WDMA Certification.
3. Evidence of CSA Certification.
4. Test report(s) by independent testing agency itemizing compliance and acceptable to authorities having jurisdiction.
D. Test Reports: Prior to submitting shop drawings or starting fabrication, submit test report(s) by independent testing agency showing compliance with performance requirements in excess of those prescribed by specified grade.
E. Field Quality Control Submittals: Report of field testing for water penetration and air leakage.
1.04 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this section with minimum three years of documented experience.
B. Installer Qualifications: Company specializing in performing work of type specified and with at least three years of documented experience.
1.05 DELIVERY, STORAGE, AND HANDLING
A. Comply with requirements of AAMA CW-10.
B. Protect finished surfaces with wrapping paper or strippable coating during installation. Do not use adhesive papers or sprayed coatings that bond to substrate when exposed to sunlight or weather.
1.06 FIELD CONDITIONS
A. Do not install sealants when ambient temperature is less than 40 degrees F.
B. Maintain this minimum temperature during and 24 hours after installation of sealants.
1.07 WARRANTY
A. Correct defective work within a five year period after Date of Substantial Completion.
B. Manufacturer Warranty: Provide 5-year manufacturer warranty against failure of glass seal on insulating glass units, including interpane dusting or misting. Include provision for replacement of failed units. Complete forms in Owner's name and register with manufacturer.
C. Manufacturer Warranty: Provide 20-year manufacturer warranty against excessive degradation of exterior finish. Include provision for replacement of units with excessive fading, chalking, or flaking. Complete forms in Owner's name and register with manufacturer.
PART 2 PRODUCTS
2.01 ALUMINUM WINDOWS
A. Aluminum Windows: Extruded aluminum frame and sash, factory fabricated, factory finished, with operating hardware, related flashings, and anchorage and attachment devices.
1. Frame Depth: 3-1/2 inch.
2. Operable Units: Double weatherstripped.
Page
Aluminum Windows 08 5113
3. Provide factory-glazed units.
4. Fabrication: Joints and corners flush, hairline, and weatherproof, accurately fitted and secured; prepared to receive anchors; fasteners and attachments concealed from view;
reinforced as required for operating hardware and imposed loads.
5. Perimeter Clearance: Minimize space between framing members and adjacent construction while allowing expected movement.
6. Movement: Accommodate movement between window and perimeter framing and deflection of lintel, without damage to components or deterioration of seals.
7. System Internal Drainage: Drain to the exterior by means of a weep drainage network any water entering joints, condensation occurring in glazing channel, and migrating moisture occurring within system.
B. Horizontal Sliding Type:
1. Construction: Thermally broken.
2. Provide screens.
3. Glazing: Double; clear; low-e.
4. Exterior Finish: High performance powder coatings.
5. Interior Finish: High performance powder coatings.
2.02 PERFORMANCE REQUIREMENTS
A. Grade: AAMA/WDMA/CSA 101/I.S.2/A440 requirements for specific window type:
1. Performance Class (PC): LC.
2. Performance Grade (PG): 25, with minimum design pressure (DP) of 25.06 psf.
B. Member Deflection: Limit member deflection to flexure limit of glass in any direction, with full recovery of glazing materials.
C. Wind-Borne-Debris Resistance: Identical full-size glazed assembly without auxiliary protection, tested by independent agency in accordance with ASTM E1996 for Wind Zone 4 - Additional Protection for Large and Small Missile impact and pressure cycling at design wind pressure.
D. Water Leakage: No uncontrolled leakage on interior face when tested in accordance with ASTM E331 at differential pressure of 12.11 psf.
E. Air Leakage: 0.1 cfm/sq ft maximum leakage per unit area of outside window frame dimension when tested at 1.57 psf pressure difference in accordance with ASTM E283/E283M.
F. Condensation Resistance Factor of Frame: 50, measured in accordance with AAMA 1503.
G. Overall Thermal Transmittance (U-value): .46, maximum, including glazing, measured on window sizes required for this project.
2.03 COMPONENTS
A. Frames: 60 inch wide by 50 inch deep profile, of 2.375 inch thick section; thermally broken with interior portion of frame insulated from exterior portion; flush glass stops of snap-on type.
B. Insect Screens: Extruded aluminum frame with mitered and reinforced corners; screen mesh taut and secure to frame; secured to window with adjustable hardware allowing screen removal without use of tools.
1. Hardware: Spring loaded steel pins; four per screen unit.
2. Screen Mesh: Vinyl-coated fiberglass, window manufacturer's standard mesh.
3. Frame Finish: Same as frame and sash.
C. Operable Sash Weatherstripping: Wool pile; permanently resilient, profiled to achieve effective weather seal.
D. Sealant for Setting Sills and Sill Flashing: Non-curing butyl type.
2.04 MATERIALS
A. Extruded Aluminum: ASTM B221 (ASTM B221M), 6063 alloy, T6 temper.
Page
Aluminum Windows 08 5113
2.05 HARDWARE
A. Operator: Lever action handle fitted to projecting sash arms with limit stops.
B. Bottom Rollers: Stainless steel, adjustable.
2.06 FINISHES
A. High Performance Organic Coating: Primer and topcoat coatings system based on super durable polyester resin powder; with minimum dry film thickness (DFT) of 2 to 3.5 mil, 0.0020 to 0.0035 inch over aluminum extrusions and panels; meeting requirements of AAMA 2604.
PART 3 EXECUTION
3.01 PRIME WINDOW INSTALLATION
A. Install windows in accordance with manufacturer's instructions.
B. Install window assembly in accordance with AAMA/WDMA/CSA 101/I.S.2/A440.
C. Install windows in accordance with ASTM E2112.
D. Attach window frame and shims to perimeter opening to accommodate construction tolerances and other irregularities.
E. Align window plumb and level, free of warp or twist. Maintain dimensional tolerances and alignment with adjacent work.
F. Install sill and sill end angles.
G. Provide thermal isolation where components penetrate or disrupt building insulation. Pack fibrous insulation in shim spaces at perimeter of assembly to maintain continuity of thermal barrier.
H. Install operating hardware not pre-installed by manufacturer.
3.02 TOLERANCES
A. Maximum Variation from Level or Plumb: 1/16 inches every 3 ft non-cumulative or 1/8 inches per 10 ft, whichever is less.
3.03 FIELD QUALITY CONTROL
A. See Section 01 4000 - Quality Requirements for independent field testing and inspection requirements, and requirements for monitoring quality of specified product installations.
B. Provide field testing of installed aluminum windows by independent laboratory in accordance with AAMA 502 and AAMA/WDMA/CSA 101/I.S.2/A440 during construction process and before installation of interior finishes.
1. Field test for water penetration in accordance with ASTM E1105 using Procedure B -cyclic static air pressure difference; test pressure shall not be less than 1.9 psf.
2. Field test for air leakage in accordance with ASTM E783 with uniform static air pressure difference of 1.57 psf.
C. Repair or replace fenestration components that have failed designated field testing, and retest to verify performance complies with specified requirements.
3.04 ADJUSTING
A. Adjust hardware for smooth operation and secure weathertight closure.
3.05 CLEANING
A. Remove protective material from factory finished aluminum surfaces.
B. Wash surfaces by method recommended and acceptable to window manufacturer; rinse and wipe surfaces clean.
C. Upon completion of installation, thoroughly clean aluminum surfaces in accordance with AAMA
609 & 610.
END OF SECTION
Page
Door Hardware 08 7100
SECTION 08 7100
DOOR HARDWARE
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Hardware for hollow metal doors.
B. Thresholds.
C. Weatherstripping and gasketing.
1.02 RELATED REQUIREMENTS
A. Section 08 1113 - Hollow Metal Doors and Frames.
1.03 REFERENCE STANDARDS
A. ADA Standards - 2010 ADA Standards for Accessible Design; 2010.
B. BHMA A156.1 - Standard for Butts and Hinges; 2021.
C. BHMA A156.3 - Exit Devices; 2025.
D. BHMA A156.4 - Door Closers and Pivots; 2024.
E. BHMA A156.5 - Cylinders and Input Devices for Locks; 2020.
F. BHMA A156.6 - Standard for Architectural Door Trim; 2021.
G. BHMA A156.7 - Template Hinge Dimensions; 2022.
H. BHMA A156.8 - Door Controls - Overhead Stops and Holders; 2021.
I. BHMA A156.15 - Release Devices - Closer Holder, Electromagnetic and Electromechanical;
2021.
J. BHMA A156.18 - Standard for Materials and Finishes; 2020.
K. BHMA A156.21 - Thresholds; 2025.
L. BHMA A156.22 - Standard for Gasketing; 2021.
M. BHMA A156.31 - Electric Strikes and Frame Mounted Actuators; 2024.
N. BHMA A156.115 - Hardware Preparation in Steel Doors and Frames; 2016.
O. ICC A117.1 - Accessible and Usable Buildings and Facilities; 2017.
P. NFPA 101 - Life Safety Code; Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements.
Q. UL 437 - Standard for Key Locks; Current Edition, Including All Revisions.
1.04 ADMINISTRATIVE REQUIREMENTS
A. Coordinate the manufacture, fabrication, and installation of products that door hardware is installed on.
B. Furnish templates for door and frame preparation to manufacturers and fabricators of products requiring internal reinforcement for door hardware.
1.05 SUBMITTALS
A. Product Data: Manufacturer's catalog literature for each type of hardware, marked to clearly show products to be furnished for this project, and includes construction details, material descriptions, finishes, and dimensions and profiles of individual components.
B. Shop Drawings - Door Hardware Schedule: Submit detailed listing that includes each item of hardware to be installed on each door. Use door numbering scheme as included in Contract Documents.
1. Prepared by or under supervision of Architectural Hardware Consultant (AHC).
2. List groups and suffixes in proper sequence.
3. Provide complete description for each door listed.
Page
Door Hardware 08 7100
4. Provide manufacturer name, product names, and catalog numbers; include functions, types, styles, sizes and finishes of each item.
5. Include account of abbreviations and symbols used in schedule.
C. Maintenance Data: Include data on operating hardware, lubrication requirements, and inspection procedures related to preventative maintenance.
D. Project Record Documents: Record actual locations of concealed equipment, services, and conduit.
E. Maintenance Materials and Tools: Furnish the following for Owner's use in maintenance of project.
1. Lock Cylinders: Ten for each master keyed group.
2. Tools: One set of each special wrench or tool applicable for each different or special hardware component, whether supplied by hardware component manufacturer or not.
1.06 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this section with minimum three years of documented experience.
B. Supplier Qualifications: Company with certified Architectural Hardware Consultant (AHC) to assist in work of this section.
1.07 DELIVERY, STORAGE, AND HANDLING
A. Package hardware items individually; label and identify each package with door opening code to match door hardware schedule.
1.08 WARRANTY
A. Manufacturer's Warranty: Provide warranty against defects in material and workmanship for period indicated. Complete forms in Owner's name and register with manufacturer.
1. Closers: Five years, minimum.
2. Exit Devices: Three years, minimum.
3. Locksets and Cylinders: Three years, minimum.
4. Other Hardware: Two years, minimum.
PART 2 PRODUCTS
2.01 DESIGN AND PERFORMANCE CRITERIA
A. Provide specified door hardware as required to make doors fully functional, compliant with applicable codes, and secure to extent indicated.
B. Provide individual items of single type, of same model, and by same manufacturer.
C. Provide door hardware products that comply with the following requirements:
1. Applicable provisions of federal, state, and local codes.
2. Accessibility: ADA Standards and ICC A117.1.
3. Hardware Preparation for Steel Doors and Steel Frames: BHMA A156.115.
2.02 HINGES
A. Hinges: Comply with BHMA A156.1, Grade 1.
1. Butt Hinges: Comply with BHMA A156.1 and BHMA A156.7 for templated hinges.
a. Provide hinge width required to clear surrounding trim.
2. Provide hinges on every swinging door.
3. Provide five-knuckle full mortise butt hinges unless otherwise indicated.
4. Provide ball-bearing hinges at each door with closer.
5. Provide non-removable pins on exterior outswinging doors.
6. Provide non-removable pins on interior outswinging doors at locations as indicated.
7. Provide power transfer hinges where electrified hardware is mounted in door leaf.
8. Provide following quantity of butt hinges for each door:
a. Doors up to 60 inches High: Two hinges.
Page
Door Hardware 08 7100
b. Doors From 60 inches High up to 90 inches High: Three hinges.
c. Doors 90 inches High up to 120 inches High: Four hinges.
2.03 EXIT DEVICES
A. Manufacturers:
1. Basis of Design: Von Duprin, an Allegion brand;99 Series: www.allegion.com/us/#sle..
B. Exit Devices: Comply with BHMA A156.3, Grade 1.
1. Lever design to match lockset trim.
2. Provide cylinder with cylinder dogging or locking trim.
3. Provide exit devices properly sized for door width and height.
4. Provide strike as recommended by manufacturer for application indicated.
5. Provide UL (DIR) listed exit device assemblies for fire-rated doors and panic device assemblies for non-fire-rated doors
6. .Grooved case.
2.04 ELECTRIC STRIKES
A. Manufacturers:
B. Electric Strikes: Comply with BHMA A156.31, Grade 1.
1. Provide UL (DIR) listed burglary-resistant electric strike; style to suit locks.
2. Provide non-handed 24 VDC electric strike suitable for door frame material and scheduled lock configuration.
2.05 LOCK CYLINDERS
A. Manufacturers:
1. Basis of Design: Best. Provided by Owner.
2.06 CYLINDRICAL LOCKS
A. Manufacturers:
1. Basis of Design: Sargent, 10X Line, "L" rose and "L" lever. Prefix 70 to accept owner cylinder core..
2.07 CLOSERS
A. Manufacturers; Surface Mounted:
1. Basis of Design: LCN 4040.
B. Closers: Comply with BHMA A156.4, Grade 1.
1. Type: Surface mounted to door.
2. Provide door closer on each exterior door.
3. At corridor entry doors, mount closer on room side of door.
4. At outswinging exterior doors, mount closer on interior side of door.
2.08 THRESHOLDS
A. Thresholds: Comply with BHMA A156.21.
1. Provide threshold at interior doors for transition between two different floor types, and at openings from garage spaces to interior spaces at office area., unless otherwise indicated.
2. Provide threshold at each exterior door, unless otherwise indicated.
3. Type: Flat surface.
4. Material: Aluminum.
5. Threshold Surface: Fluted horizontal grooves across full width.
6. Field cut threshold to profile of frame and width of door sill for tight fit.
7. Provide non-corroding fasteners at exterior locations.
2.09 WEATHERSTRIPPING AND GASKETING
A. Weatherstripping and Gasketing: Comply with BHMA A156.22.
1. Head and Jamb Type: Adjustable.
2. Door Sweep Type: Door shoe with drip cap.
Page
Door Hardware 08 7100
3. Material: Aluminum, with neoprene weatherstripping.
4. Provide weatherstripping on each exterior door at head, jambs, and meeting stiles of door pairs, unless otherwise indicated.
5. Provide door bottom sweep on each exterior door, unless otherwise indicated.
2.10 RAIN GUARD
A. Rain Guard: Comply with BHMA A156.22.
1. Head: Adjustable.
2. Material: Aluminum.
B. Provide door rain guard on each exterior door, unless otherwise indicated.
C. Provide applicable gasketing on doors indicated as "Lightproof."
2.11 SILENCERS
A. Silencers: Provide at equal locations on door frame to mute sound of door's impact upon closing.
1. Single Door: Provide three on strike jamb of frame.
2. Material: Rubber, gray color.
2.12 FINISHES
A. Finishes: Provide door hardware of same finish, unless otherwise indicated.
1. Finish: 626; satin chromium plated over nickel, with brass or bronze base material (former US equivalent US26D); BHMA A156.18.
2. Exceptions:
a. Where base…