Service Specifications.xlsx

XLSX spreadsheet 23 KB Posted

Attached to
BPA for MTS Brand Materials and Services: Supporting New and Legacy Equipment
Solicitation number
N0016725Q1100
Issued by

About this file

The file is a Service Specifications spreadsheet detailing annual maintenance and service requirements for load frames and hydraulic power units (HPUs) at the Naval Surface Warfare Center Carderock Division (NSWCCD). The document outlines comprehensive maintenance tasks for seven test stations and multiple hydraulic pumps, including routine inspections, LVDT and force calibrations, filter replacements, and fluid analyses for equipment located in Buildings 19 and C-3, with a site number of 505463.

The spreadsheet also includes specific tasking for equipment repairs and upgrades, such as actuator rebuilds, hydraulic seal replacements, servovalve modifications, crosshead lock repairs, grip and controller installations, and provisions for unplanned technical issues. This is part of a 5-year Blanket Purchase Agreement (BPA) for MTS Brand Materials and Services, which will be awarded on a sole-source basis by the Department of the Navy Naval Sea Systems Command, with the solicitation number N0016725Q1100. The tasks primarily involve MTS and Instron test equipment, with services to be performed at the NSWCCD facility.

View the file

Other files

File Type Posted
MTS JA_Redacted.pdf PDF
Combined Synopsis Solicitation N0016725Q1100 MTS.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Table 1

TASKS - ANNUAL MAINTENANCE
LOAD FRAMES
Task #System NameRequired ServiceLocationMTS Site No.
1Test Station #2 MTS +/- 500kipRoutine inspection, LVDT Calibration, Force CalibrationBldg. 19, Rm. B-161505463
2Test Station #3 Instron +/- 200kipRoutine inspection, LVDT Calibration, Force CalibrationBldg. 19, Rm. B-161505463
3Test Station #5 MTS +/- 50kip (Southeast)Routine inspection, LVDT Calibration, Force CalibrationBldg. 19, Rm. B-161505463
4Test Station #6 MTS +/- 55kip (Center Bay)Routine inspection, LVDT Calibration, Force CalibrationBldg. 19, Rm. B-161505463
5Test Station #7 MTS +/- 50kip (Slotted Table)Routine inspection, LVDT Calibration, Force CalibrationBldg. 19, Rm. B-161505463
6Test Station #9 MTS +/- 100kipRoutine inspection, LVDT Calibration, Force CalibrationBldg. 19, Rm. B-161505463
7NEW Load Frames Acquired During BPARoutine inspection, LVDT Calibration, Force CalibrationBldg. 19, Rm. B-161505463
8NEW Load Frames Acquired During BPARoutine inspection, LVDT Calibration, Force CalibrationBldg. 19, Rm. C-3505463
HYDRAULIC PUMPS
Task #System NameRequired ServiceLocationMTS Site No.
331000kip HPU - Vickers Model 567954Routine inspection, Filter replacement, Fluid analysisBldg. 19, Rm. C-228505463
34550kip HPU - MTS Model 506.51SRoutine inspection, Filter replacement, Fluid analysisBldg. 19, Rm. C-228505463
35220kip HPU - Instron Model 210Routine inspection, Filter replacement, Fluid analysisBldg. 19, Rm. C-228505463
36100kip HPU - MTS Model 510.10CRoutine inspection, Filter replacement, Fluid analysisBldg. 19, Rm. C-228505463
3755kip HPU - MTS Model 501.01Routine inspection, Filter replacement, fluid analysisBldg. 19, Rm. C-228505463
38NEW HPU Acquired During BPARoutine inspection, Filter replacement, fluid analysisBldg. 19, Rm. C-228505463
39NEW HPU Acquired During BPARoutine inspection, Filter replacement, fluid analysisBldg. 19, Rm. C-3505463
Tasking
Task #System NameSales EntityRequired TaskingLocation
9Test Station #2 MTS +/- 500kip
Actuator RebuildFactory repairMTS Model 209.23, Assembly 377183-01, S/N 125NSWCCD Bldg. 19, Rm. B-161
10Test Station #3 Instron +/- 200kip
Actuator RebuildFactory repairInstron Model A411-136, S/N 413NSWCCD Bldg. 19, Rm. B-161
11Test Station #5 MTS +/- 50kip (Southeast)
Actuator RebuildFactory repairMTS Model 204.71, Assembly 094080-05, S/N 377NSWCCD Bldg. 19, Rm. B-161
12Test Station #6 MTS +/- 55kip (Center Bay)
Actuator RebuildFactory repairMTS Model 244.31, Assembly 367707-01, S/N 135NSWCCD Bldg. 19, Rm. B-161
13Test Station #7 MTS +/- 50kip (Slotted Table)
Actuator RebuildFactory repairMTS Model 244.31, Assembly 368215-74, S/N 252NSWCCD Bldg. 19, Rm. B-161
14Test Station #9 MTS +/- 100kip
Actuator RebuildFactory repairMTS Model 202.41, S/N 383NSWCCD Bldg. 19, Rm. B-161
15Test Station #2 MTS +/- 500kip
Replace Hydraulic SealsService SalesMTS Model 641.39, Assembly 50568201, S/N 0238424NSWCCD Bldg. 19, Rm. B-161
16Test Station #3 Instron +/- 200kip
Replace Hydraulic SealsService SalesMTS Model 647.100, P/N 53-137-202, S/N 10673108NSWCCD Bldg. 19, Rm. B-161
17Test Station #5 MTS +/- 50kip (Southeast)
Replace Hydraulic SealsService SalesMTS Model 647.25, P/N 47080905, S/N 10317331NSWCCD Bldg. 19, Rm. B-161
18Test Station #6 MTS +/- 55kip (Center Bay)
Replace Hydraulic SealsService SalesMTS Model 641.37, Assembly 417904-01, S/N 0106420NSWCCD Bldg. 19, Rm. B-161
19Test Station #9 MTS +/- 100kip
Replace Hydraulic SealsService SalesMTS Model 641.37, S/N 121NSWCCD Bldg. 19, Rm. B-161
20Test Stations #5, #6, and #7
Servovalve Replacement and AdditionService SalesReplacement of existing servovalve and addition of servovalve to allow dual 15gpm operation (with one port shut-off valve for one of the servovalves)NSWCCD Bldg. 19, Rm. B-161
21Test Station #2 MTS +/- 500kip
Repair Hydraulic Crosshead LocksService SalesMTS Model 311.41, Assembly 377186-01, S/N 449NSWCCD Bldg. 19, Rm. B-161
22Test Station #3 Instron +/- 200kip
Repair Hydraulic Crosshead LocksService SalesInstron Model CW 2105, S/N 1335 10NSWCCD Bldg. 19, Rm. B-161
23Test Station #5 MTS +/- 50kip (Southeast)
Repair Hydraulic Crosshead LocksService SalesMTS Model 311.21, S/N 378NSWCCD Bldg. 19, Rm. B-161
24Test Station #6 MTS +/- 55kip (Center Bay)
Repair Hydraulic Crosshead LocksService SalesMTS Model 311.21, Assembly 377905-01, S/N 476NSWCCD Bldg. 19, Rm. B-161
25Test Station #7 MTS +/- 50kip (Slotted Table)
Repair Hydraulic Crosshead LocksService SalesMTS Model 322.41, Assembly 410863-01, S/N 158NSWCCD Bldg. 19, Rm. B-161
26Test Station #9 MTS +/- 100kip
Repair Hydraulic Crosshead LocksService SalesMTS Model 312.41, S/N 177NSWCCD Bldg. 19, Rm. B-161
27Test Station #9 MTS +/- 100kip
Grip InstallationService SalesInstallation of MTS Model 641.37 hydraulic collet grip unit to existing MTS Model 312.41 load frameNSWCCD Bldg. 19, Rm. B-161
28Test Station #9 MTS +/- 100kip
Controller InstallationService SalesComplete installation of frame to include cable hook-up and new station set up with
existing FlexTest station.NSWCCD Bldg. 19, Rm. B-161
29Test Station #6 MTS +/- 55kip (Center Bay)
Controller InstallationService SalesComplete installation of existing MTS Model 311.21 load frame to include cable hook-up and new station setup with NEW FlexTest station and existing MTS Model 501.01 HPUNSWCCD Bldg. 19, Rm. B-161
30Test Station #3 Instron +/- 200kip
Controller InstallationService SalesComplete installation of existing MTS Model 311.21 load frame to include cable hook-up and new station setup with same FlexTest station as task (27) and existing Instron Model 210 HPUNSWCCD Bldg. 19, Rm. B-161
31Test Station #9 MTS +/- 100kip
Return to OperationService SalesResolution of necessary material and services required to return existing MTS Model 311.21 load frame to operation.NSWCCD Bldg. 19, Rm. B-161
32Service Unplanned TaskingService SalesResolution of unforseen/unplanned technical issues with MTS equipment.NSWCCD Bldg. 19, Rm. B-161

File details come from the government source that posted it. Updated .