Security Door Project Specs.pdf
PDF 2 MB Posted
- Attached to
- Cheboygan Area High School Security Door Project
- Solicitation number
- RFP CHEB 260000002305 1
- Issued by
- Chippewa County, Cheboygan City, Michigan
About this file
This is a project specification document for the Cheboygan Area High School Security Door Project located at 801 W Lincoln Avenue, Cheboygan, Michigan 49721. The project involves the addition of a new security door in an existing hallway within the Vocational Arts Wing of the high school building. The security doors, measuring 3'-0" x 7'-0", are designed to be cross-corridor doors that tie into the fire alarm and school clock system, remaining unlocked during normal school hours and locked after hours while swinging freely when activated by the fire alarm. The work is governed by the 2021 Michigan Building Code, 2021 Michigan Rehabilitation Code for Existing Buildings, 2023 National Electrical Code, 2021 International Fire Code, and 2017 ANSI A117.1 accessibility standards. The project is classified as Use Group E (Education) with Construction Type II-B fire protection for a partially sprinklered building. The project specifications were issued for owner review on January 9, 2026, and released as a bid/permit set on May 5, 2026.
The door specifications include detailed architectural drawings with composite floor plans, work area floor plans, and enlarged floor plan elevations showing the door and frame configuration. Hardware specifications detail six 4.5" x 4.5" hinges by Ives, two surface vertical rod exit devices with power transfer and supply by Von Duprin, two closers and sweeps by LCN and NGP respectively, four stainless steel kick plates by Ives, and transoms with safety glazing. The 36" x 84" x 1¾" solid core wood door features a stain finish to match existing corridor doors and a 24" x 36" vision lite with safety glazing. A card reader is noted as furnished by others. Project contacts include Three Rivers Design, Inc. (Architect), with Kristin Riddle and Fred Bartlett listed as the responsible parties, and Cheboygan Area Schools represented by Superintendent Spencer Byrd and Stephen Fleming, Transportation, Maintenance & Grounds Manager.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Security Door Project.2.pdf | ||
| Security Door Project Ad.2.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
801 W LINCOLN AVE, CHEBOYGAN, MI 49721
CHEBOYGAN HIGH SCHOOL
2026 SECURITY DOOR PROJECT FOR:
BUILDING CODE DATA
INDEX OF DRAWINGS
SITE LOCATION MAP SITE MAP
CONTACTS
PROJECT IMAGE
REVIEWS
BID
OW
NE
R
RE
VI
EW
(0 1-
-2
6)
BI
D/
PE
RM
IT
S
ET
(0
5-
-2 6)
SAFETY
50%
100%
A1.1 COVER SHEET X X
ARCHITECTURAL
A4.0 COMPOSITE FLOOR PLAN X X
A4.1 WORK AREA FLOOR PLAN X X
A4.2 ENLARGED FLOOR PLAN - DOOR & FRAME ELEVATION X X
DESCRIPTION OF WORK
ADDITION OF A NEW SECURITY DOOR IN AN EXISTING HALLWAY WITHIN THE VOCATIONAL ARTS WING OF THE EXISTING HIGH SCHOOL BUILDING.
CODE COMPLIANCE
BUILDING CODE: 2021 MICHIGAN BUILDING CODE (MBC)
REHABILITATION CODE: 2021 MICHIGAN REHABILITATION CODE FOR EXISTING BUILDING (MRC)
ELECTRICAL CODE: 2023 NATIONAL ELECTRICAL CODE (NEC)
FIRE CODE 2021 INTERNATIONAL FIRE CODE (IFC)
ACCESSIBILITY CODE: 2017 ANSI A117.1-2017 (A117.1)
USE GROUP
E - EDUCATION
CONSTRUCTION TYPE
II-B
FIRE PROTECTION
PARTIALLY SPRINKLERED
WORK AREA - NO FIRE PROTECTION
OCCUPANT LOAD
UNCHANGED BY RENOVATION
NUMBER OF EXITS
UNCHANGED BY RENOVATION
ALLOWABLE TRAVEL DISTANCE
UNCHANGED BY RENOVATION
N N
SEALS
ARCHITECTURAL
E2 6-
C H
EB
O
YG
A
N H
IG
H
S C
H O
O L
S
EC
U R
IT
Y
D O
O R
P R
O
JE
C T
C O P T I NR O R A O
THREERIVERS
3069 Vantage Point Drive, P.O. Box 1467, Midland, MI 48641-1467 Phone: 989.631.9726 Fax: 989.631.7402 Email: info@trccompany.com Web: www.trccompany.com
SCHOOL
CHEBOYGAN AREA SCHOOLS
7461 N. STRAITS HWY., CHEBOYGAN, MI 49721
SPENCER BYRD, SUPERINTENDENT
PHONE: (231) 627-4436
EMAIL: byrds@chebschools.com
STEPHEN FLEMING, TRANSPORTATION, MAINTENANCE & GROUNDS MANAGER
PHONE: (231) 627-4422
EMAIL: flemings@chebschools.com
ARCHITECT
THREE RIVERS DESIGN, INC.
KRISTIN RIDDLE, ARCHITECT - PHONE: 989.631.9726
FRED BARTLETT - DESIGN PM: 989.631.9726 x1108
EMAIL: fbartlett@trccompany.com
GYMNASIUM
BOILER ROOM
CAFETERIA
KITCHEN
COURTYARD
AUDITORIUM
LIBRARY
COURTYARD
ADMINISTRATION
CLASSROOMS
CLASSROOMS
CLASSROOMS
CLASSROOMSCLASSROOMS
CLASSROOMS
CLASSROOMS
CHORALART & DRAFTING
DINING ROOM
TEACHING
KITCHEN
AUTO SHOP
WOOD SHOP
MACHINE SHOP
SHEET NUMBER
SHEET TITLE
ISSUED
CH
EB
OY
GA
N
HI
GH
S
CH
OO
L
SE
CU
RI
TY
D
OO
R
PR
OJ
EC
T
W L
IN
CO
LN
A
VE
, C
HE
BO
YG
AN
, M I 4
ABCDE
ABCDE
DRAWN BY: FPB
CHECKED BY: KRR
SHEET INFORMATION
PROJECT NUMBER
E26-371
COPYRIGHT © 2026 ALL RIGHTS RESERVED
A4.0
COMPOSITE FLOOR PLAN
01-09-26 OWNER REVEIW
05-05-26 BID/PERMIT SET
SCALE:
N
HIGH SCHOOL
COMPOSITE FLOOR PLAN
1" = 20'-0"
WORK AREA
VOCATIONAL ARTS WING
SHEET NUMBER
SHEET TITLE
ISSUED
CH
EB
OY
GA
N
HI
GH
S
CH
OO
L
SE
CU
RI
TY
D
OO
R
PR
OJ
EC
T
W L
IN
CO
LN
A
VE
, C
HE
BO
YG
AN
, M I 4
ABCDE
ABCDE
DRAWN BY: FPB
CHECKED BY: KRR
SHEET INFORMATION
PROJECT NUMBER
E26-371
COPYRIGHT © 2026 ALL RIGHTS RESERVED
A4.1
WORK AREA FLOOR PLAN
01-09-26 OWNER REVIEW
05-05-26 BID/PERMIT SET
STORAGE
EXISTING RAMP
DN
TEACHING
KITCHEN
COOLER
OFFICE
TOILET
DISH WASH
MECH. RM.
DINING ROOM /
CLASSROOM
CORRIDOR
TOILET
AUTO SHOP
CLASSROOM
TOOL CRIB
OFFICE
WOOD SHOP
MACHINE SHOP
OFFICE
ELECT. RM.
GRINDING
PLANNING ROOM
STORAGE
OFFICE
MECH. RM.
CORRIDOR
CORRIDOR
FINISHING
LOBBY
GYMNASIUM & LOCKER ROOMS
OFFICE
OFFICE
OFFICE /
LIBRARY
PRACTICE
UNIFORMS
CHORAL
CLASSROOM
J.C.
ENSEMBLE
PRACTICE
PRACTICE
PRACTICE
PRATICE
ART & DRAFTING
CLASSROOM
SEE ENLARGED PLAN
SHEET A4.2
NEW CROSS-CORRIDOR
SECURITY DOORS
SCALE:
NWORK AREA FLOOR PLAN (VOCATIONAL EDUCATION WING)
1/8" = 1'-0"
1387SF / 50 = 28 OCCUPANTS 3360SF / 50 = 68 OCCUPANTS
3460SF / 50 = 70 OCCUPANTS
EXIT
EXIT
EXIT EXIT
EXIT
EXIT CAPACITY:
36" DOOR/.2 = 180 OCCUPANTS
(SERVING 166 OCCUPANTS)
7'-0" 5"
6' -8
5'-0"
RAMP LANDING
8' -7
6'-8"
7' -0
2"
1' -3
2"
4"2'-11" 2"
2'-11"4"
3'-0" 3'-0"
6" 3'
-0
6" 2'-0" 6"
4"4"
SHEET NUMBER
SHEET TITLE
ISSUED
CH
EB
OY
GA
N
HI
GH
S
CH
OO
L
SE
CU
RI
TY
D
OO
R
PR
OJ
EC
T
W L
IN
CO
LN
A
VE
, C
HE
BO
YG
AN
, M I 4
ABCDE
ABCDE
DRAWN BY: FPB
CHECKED BY: KRR
SHEET INFORMATION
PROJECT NUMBER
E26-371
COPYRIGHT © 2026 ALL RIGHTS RESERVED
A4.2
ENLARGED FLOOR PLAN
01-09-26 OWNER REVIEW
05-05-26 BID/PERMIT SET
EXISTING RAMP
DN
DINING ROOM /
CLASSROOM
AUTO SHOP
CLASSROOM
- WOOD SHOP
CORRIDOR
CORRIDOR
CHORAL
CLASSROOM
ENSEMBLE
PRACTICE
ART & DRAFTING
CLASSROOM
EXISTING CABINET UNIT HEATER
NEW 3'-0"x7'-0" CROSS-CORRIDOR SECURITY DOORS
- TIED TO FIRE ALARM & SCHOOL CLOCK SYSTEM.
DOORS TO REMAIN UNLOCKED DURING NORMAL
SCHOOL HOURS, LOCKED AFTER HOURS; DOORS TO
SWING FREELY WHEN ACTIVATED BY FIRE ALARM.
SCALE:
NENLARGED FLOOR PLAN
1/4" = 1'-0"
10" KICK PLATES - EACH SIDE
4" H.M. FRAME
JAMBS(PAINT)
24"x36" VISION LITE w/ SAFETY GLAZING
36"x84"x1 3/4" SOLID CORE WOOD
DOOR (STAIN FINISH TO MATCH
EXISTING CORRIDOR DOORS)
SCALE:
DOOR & FRAME ELEVATION
3/8" = 1'-0"
A4.2
EXISTING CORRIDOR VIEW EXISTING CABINET UNIT HEATER EXISTING CORRIDOR DOOR (MATCH)
TRANSOMS w/
SAFETY GLAZING
DOOR HARDWARE
6 – HINGES, 5BB1 4.5” X 4.5” X NRP X 652, BY IVES.
1 – SURFACE VERTICAL ROD EXIT DEVICE, 9827NL-F X 36” X 990NL-R/V X 626, BY VONDUPRIN.
1 – SURFACE VERTICAL ROD EXIT DEVICE, QEL 9827NL-F X 36” X 990NL-R/V X 626, BY VONDUPRIN.
1 – POWER TRANSFER, EPT10 X 689, BY VONDUPRIN.
1 – POWER SUPPLY, PS902 X 900-2RS, BY VONDUPRIN.
2 – CLOSERS, 4040XP X SCUSH X 689, BY LCN.
2 – SWEEPS, 601A X 36” X 689, BY NGP.
4 - KICK PLATES, 10" X 34", STAINLESS STEEL, BY IVES.
**CARD READER BY OTHERS
File details come from the government source that posted it. Updated .